• 제목/요약/키워드: $CO_2$ generator

검색결과 215건 처리시간 0.026초

Derivation of External Exposure Characteristics of Industrial Radiography Based on Empirical Evidence

  • Cho, Junik;Kim, Euidam;Kwon, Tae-Eun;Chung, Yoonsun
    • Journal of Radiation Protection and Research
    • /
    • 제47권2호
    • /
    • pp.93-98
    • /
    • 2022
  • Background: This study aims to derive the characteristics of each work type for industrial radiography based on empirical evidence through expert advice and a survey of radiation workers of various types of industrial radiography. Materials and Methods: According to a Korean report, work types of industrial radiography are classified into indoor tests, underground pipe tests, tests in a shielded room (radiographic testing [RT] room test), outdoor field tests, and outdoor large structure tests. For each work type, exposure geometry and radiation sources were mainly identified through the expert advice and workers' survey as reliable empirical evidence. Results and Discussion: The expert advice and survey results were consistent as the proportion of the work types were high in the order of RT room test, outdoor large structure test, underground pipe test, outdoor field test, and indoor test. The outdoor large structure test is the highest exposure risk work type in the industrial radiography. In most types of industrial radiography, radiation workers generally used 192Ir as the main source. In the results of the survey, the portion of sources was high in the order of 192Ir, X-ray generator, 60Co, and 75Se. As the exposure geometry, the antero-posterior geometry is dominant, and the rotational and isotropic geometry should be also considered with the work type. Conclusion: In this study, through expert advice and a survey, the external exposure characteristics for each work type of industrial radiography workers were derived. This information will be used in the reconstruction of organ dose for health effects assessment of Korean radiation workers.

Microcomputer를 이용(利用)한 Data Acquisition System에 관(關)한 연구(硏究) (A Microcomputer-Based Data Acquisition System)

  • 김기대;김상래
    • Journal of Biosystems Engineering
    • /
    • 제7권2호
    • /
    • pp.18-29
    • /
    • 1983
  • 효율적(效率的)인 농업기계(農業機械)의 실내(室內) 및 실외실험(室外實驗)을 위(爲)하여 Microcomputer에 의(依)한 Data 측정(測定)을 위(爲)해 A/D 변환기(變煥器)를 Interface 시키고, 이를 기록보관(記錄保管)하기 위해 Computer memory인 2716용(用) EPROM programmer와 Microprinter를 interface시켰고, 실험(實驗) 후(後)Data를 다시 HP computer로 전송(傳送)하기 위(爲)한 RS232C 장치(裝置) 등(等)의 Hardware를 구성(構成)하고, 이들의 작동(作動)을 위(爲)한 Microprogram을 개발(開發)하여 Data acquisition system으로 활용(活用)할 수 있는 방안(方案)을 연구(硏究)한 본(本) 연구(硏究)의 주요(主要) 결과(結果)를 요약(要約)하면 다음과 같다. 1. 사용(使用) channel수(數), 측정시간(測定時間) 간격(間隔) 및 측정(測定) data수(數)를 자유(自由)로 조정할 수 있는 측정용(測定用) microprogram을 개발(開發)하였으며 최소(最小) 측정시간(測定時間) 간격(間隔)은 $58.8{\mu}s$이었다. 2. A/D 변환기(變煥器)의 Calibration을 위(爲)해 Function generator에서 삼각파(三角波), 구형파(矩形波), sin파등(波等)을 발생(發生)시켜 Oscillograph에서 확인(確認)하고 이를 계측(計測)하여 보관(保管)한 후(後) HP Computer에 전송(傳送)하여 plotting한 결과(結果) 정확(正確)한 파형(波形)을 얻을 수 있었다. 3. Data 기록(紀錄)을 위(爲)한 EPROM programmer는 잘 동작(動作)하였으며 기록(紀錄) 및 원래(原來)의 Data와 비교(比較)하는 데 총 소요시간(所要時間)은 75초 정도였고, 취급이 용이(容易)할 뿐 아니라 지워서 재사용(再使用)할 수 있어 경제적(經濟的)이었다. 4. Data의 기록(記錄)을 위(爲)한 Microprinter는 그 2kB Decimal로 변환(變換)시켜 Print하는 시간(時間)이 15분(分) 정도이었으며 계측(計測)과 동시(同時)에 기록(記錄)시키는 완속측정용(緩速測定用)으로 적당하였다. 5. 본(本) system과 HP3000 컴퓨터 간(間)의 Data 전송(傳送) 장치(裝置)를 사용(使用)하면 2k byte의 Data를 HP3000 computer로 전송(傳送)하는데 1~2분(分)정도 소요(所要)되었고, 작동(作動)은 만족스러웠다. 6. 사용(使用) 전원(電源)은 DC/DC 변환기(變煥器)를 사용(使用)하여 입력전원(入力電源)이 7~25V로 단일화(單一化)하였으며, 그 상용전류(常用電流)는 1.8A정도로 tractor의 battery를 사용(使用)할 경우도 시동시(始動時)에 전압강하(電壓降下)에 의(依)한 컴퓨터의 오동작(誤動作)이 일어나지 않았으며 야외실험(野外實驗)에서의 적응성(適應性)이 우수하였다. 이상(以上)의 결과(結果)를 종합할 때 본(本) system은 실내(室內) 및 실외(室外) 실험(實驗)을 위(爲)한 Data auquistition system으로 활용(活用)할 수 있으며 경제적면(經濟的面)이나 정말 고속 측정(側定) 면(面)에서 우수한 성능(性能)을 갖춘 것으로 인정(認定)된다.

  • PDF

Control Indian meal moth Plodia interpunctella by gas treatment

  • Han, Gyung Deok;Kwon, Hyeok;Jin, Hyun Jung;Kum, Ho Jung;Kim, Bo Hwan;Kim, Wook
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2017년도 9th Asian Crop Science Association conference
    • /
    • pp.45-45
    • /
    • 2017
  • The Indian meal moth, Plodia interpunctella, is one of the most important pests of stored food in the food processing industry worldwide. To control the Indian meal moth, methyl bromide, phosphine, high carbon dioxide, sulfuryl fluoride and plant essential oil fumigation have been considered. However, these treatments have disadvantages. For example, depleting the ozone layer, showing resistance in insect, low control efficacy or need high cost for treatment. Chlorine dioxide ($ClO_2$) is strong disinfectant and insecticide. The gas caused a malfunction in enzymes. The oxidative stress induced by $ClO_2$ gas treatment damaged to a physiological system and all life stages of P. interpunctella. The gaseous $ClO_2$ is a convincing alternative to methyl bromide for controlling P. interpunctella. The gaseous $ClO_2$ was generated by a chlorine dioxide generator (PurgoFarm Co., Ltd., Hwasung, Korea). It generated highly pure $ClO_2$ gas and the gas blown out through a vent into a test chamber. Gas entry to the chamber was automatically controlled and monitored by a PortaSene II gas leak detector (Analytical Technology, Collegeville, PA, USA). The properly prepared eggs, larvae, pupae, and adults of P. interpunctella were used in this experiment. Data were analyzed using SAS 9.4. Percentage data were statistically analyzed after arcsine-root transformation. Analysis of variance was performed using general linear model, and means were separated by the least significant difference test at P < 0.05. Fumigation is an effective management technique for controlling all stages of P. interpunctella. We found that $ClO_2$ gas treatment directly effects on egg, larvae, pupae and adults of P. interpunctella. The gas treatment with proper concentration for over a day achieved 100 % mortality in all stages of P. interpunctella and short time treatment or low concentration gas treatment results showed that the egg hatchability, pupation rate, and adult emergency rate were lowered compare with untreated control. Also, abnormal pupae or adult rate were increased. Gaseous $ClO_2$ treatment induced insecticidal reactive oxygen species (ROS), and it resulted in fatal oxidative stress in P. interpunctella. Taken together, these results showed that exposure proper concentration and time of the gas control all stages of P. interpunctella by inducing fatal oxidative stress. Further studies will be required to apply the gas treatment under real-world condition and to understanding physiological reaction in P. interpunctella caused by oxidative stress.

  • PDF

발전 설비용 CrMo강의 탄화물 구조와 조성 변화에 미치는 열화 및 크리프 손상의 영향 (The Effects of Thermal Degradation and Creep Damage on the Microstructure and Composition of the Carbides in the CrMo Steels for Power Plant)

  • 주연준;홍경태;이현웅;신동혁;김제원
    • 한국재료학회지
    • /
    • 제9권10호
    • /
    • pp.1018-1024
    • /
    • 1999
  • Sn-3.5Ag 무연합금을 Cu 및 Alloy42 리드프레임에 납땜접합 (solder joint)하고 미세조직, 젖음성, 전단강도, 시효효과를 측정하여 비교하였다. Cu의 경우, 땜납의 Sn기지상안에 Ag(sub)3Sn과 Cu(sub)6Sn(sub)5상이, 그리고 땜납/리드프레임의 경계면에서는 1∼2㎛ 두께의 Cu(sub)6Sn(sub)5상이 형성되었다. Alloy42의 경우, 기지상내에 있는 낮은 밀도의 Ag(sub)3Sn상만이, 그리고 계면에는 0.5∼1.5㎛ 두께의 FeSn(sub)2이 형성되었다. 한편, Cu에 비해 Alloy42 리드프레임에서 퍼짐면적은 크고 접촉각은 작아 더 우수한 젖음성을 나타내었으나, 전단강도는 35%, 연신율은 75%로 낮았다. 180℃에서 1주일간 시효처리 후, Cu 리드프레임에는 계면에 η-Cu(sub)6Sn(sub)5 층외에 ξ-Cu(sub)3Sn층이 성장하였고, Alloy42 리드프레임에는 기지상내에 Ag(sub)3Sn이 구형으로 조대하게 성장하였고, 계면에는 FeSn(sub)2층만이 약 1.5㎛로 성장하였다.

  • PDF

X선촬영실 내에서의 공간산란선량 변동에 관한 연구 (A Study on the Behavior of the Free Space Scatter dose in X-ray Diagnostic Room)

  • 오현주;김성수;김영일;임한영;김흥태;이후민;김학성;이상석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제17권2호
    • /
    • pp.21-27
    • /
    • 1994
  • In this pauper, when the X-ray exposure condition is 70, 90, 110 kV, 10 mAs, FFD 180 cm, FSO $10{\times}10$, $35{\times}35\;cm$, toward the $36{\times}36{\times}15\;cm$ acryl phantom, the free space scatter dose rate at the 15th points in X-ray diagnostic room was measured by electrometer and 1800 co ionization chamber. Therefore, the free space scatter dose distribution profile was drown, and then, the free space scatter dose contribution percentage was Investigated. The obtained results are summarized as following. 1. The X-ray tube leakage dose rate of the experiment generator at the 1 m from focus was measured maximum 85 mR/hr, minimum 20 mR/hr, therefore, this values was appeared below the KS rules, 2. The free space scatter dose become to larger at the primary X-ray beam around area, and lower at the back ward X-ray tube. The maximum values were 3,812 mR/hr at the front Lt 1 m $45^{\circ}$ point, minimum 117 mR/hr at the back ward 1 m $180^{\circ}C$ point. 3. As the more tube voltage and field size increase, the more free space scatter dose contribution percentage become to increase, as to 90 kV from 70 kV, increase to 12 %, to 110 kV from 90 kV, increase to 18 %, and then, become to 11 % at the $10{\times}10\;cm$ and 87 % at the $35{\times}35\;cm$. 4. The 89 % of the total producted scatter ray occured from acryl phantom, at the X-ray tube housing 6 %, at the front side back wall 5 %. 5. The free space scatter dose contribution percentage at the one point build up 80 % from the phanton direction, 14 % from the X-ray tube and collimator direction, 2.2 % from the front wall, 1.8 % from the side wall, 1.7 % the back wall.

  • PDF

유류오염토양 처리를 위한 마이크로나노버블 토양세척에 관한 연구 (A Study on the Treatment of Oil Contaminated Soils with Micro-nano Bubbles Soil Washing System)

  • 최호은;정진희;한영립;김대용;정병길;최영익
    • 한국환경과학회지
    • /
    • 제20권10호
    • /
    • pp.1329-1336
    • /
    • 2011
  • The objectives of this study are to examine the processing of oils contamination soil by means of using a micronano-bubble soil washing system, to investigate the various factors such as washing periods, the amount of micro-nano bubbles generated depending on the quantity of acid injection and quantity of air injection, to examine the features involved in the elimination of total petroleum hydrocarbons (TPHs) contained in the soil, and thus to evaluate the possibility of practical application on the field for the economic feasibility. The oils contaminated soil used in this study was collected from the 0~15 cm surface layer of an automobile junkyard located in U City. The collected soil was air-dried for 24 hours, and then the large particles and other substances contained in the soil were eliminated and filtered through sieve No.10 (2 mm) to secure consistency in the samples. The TPH concentration of the contaminated soil was found to be 4,914~5,998 mg/kg. The micronano-bubble soil washing system consists of the reactor, the flow equalization tank, the micronano- bubble generator, the pump and the strainer, and was manufactured with stainless material for withstanding acidic phase. When the injected air flow rate was fixed at 2 L/min, for each hydrogen peroxide concentrations (5, 10, 15%) the removal percents for TPH within the contaminated soil with retention times of 30 minutes were respectively identified as 4,931 mg/kg (18.9%), 4,678 mg/kg (18.9%) and, 4,513 mg/kg (17.7%). And when the injected air flow rate was fixed at 2 L/min, for each hydrogen peroxide concentrations (5, 10, 15%) the removal percents for TPH within the contaminated soil with retention times of 120 minutes were respectively identified as4,256 mg/kg (22.3%), 4,621 mg/kg (19.7%) and 4,268 mg/kg (25.9%).

120MW급 열병합 복합발전시스템의 열역학적 효율 특성 (The thermodynamic efficiency characteristics of combined cogeneration system of 120MW)

  • 최명진;김홍주;김병헌
    • 한국산학기술학회논문지
    • /
    • 제18권6호
    • /
    • pp.29-36
    • /
    • 2017
  • 본 논문은 열병합 복합발전이란 하나의 프로세스에서 전기 또는 기계 동력과 열에너지의 두 형태를 생산하는 것이다. 가스터빈 열병합 발전 시스템의 각 구성부의 성능을 변수로 전체 시스템의 연료 소모와 각 구성부의 열과 전기의 성능을 표현하여야 한다. 전체시스템은 상부 시스템인 가스터빈 2대와 하부시스템인 열회수 증기발생기(HRSG) 2대, 증기터빈 1대, 지역난방열교환기 2대로 구성되어 있다. 가스터빈 열병합 복합발전시스템에서 가동시간 기준 10,000시간 후 성능시험을 각종 시험장치 설치 및 ASME PTC 46에 준한 성능시험으로 실시하였고, 발전소 전체의 종합출력과 효율에 대한 성능을 분석하였다. 이러한 성능시험 실시자료를 기초로 시험성능을 비교하여 성능변화 값을 확인하였다. 이 논문에서 가스터빈, 열회수 증기발생기, 증기터빈의 열역학적 시스템 해석을 통하여 이론적 결과 값을 산출하였다. 비교 대상은 전체 시스템의 생산열량과 대기로 배출되는 열량을 이론값과 실험값을 비교하였고, 전기출력 및 열 출력에 대한 효율을 이론값과 실제 값을 비교하였다. 가스터빈 열병합 복합발전소 성능 특성에 대한 시험결과를 열역학적 효율 특성과 비교하였으며, 0.3%의 오차를 보였다.

무창 비육돈사에서 습식공기정화기의 여름철 공기정화효율 분석 (An Air Cleaning Efficiencies of Wet Air Cleaner in the Windowless Swine Fattening Stall in Summer)

  • 오인환;이종현;이경훈;이정훈;이동섭;어성만;이미림
    • 한국축산시설환경학회지
    • /
    • 제12권3호
    • /
    • pp.133-140
    • /
    • 2006
  • The climate of stall significantly influences on animal production ability. High concentration of ammonia gas, $CO_2$ and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and farmer health, and production ability. Therefore, it is necessary to keep clean the inside air of stall to increase the productivity. An air cleaner of wet type, consisting of a fan, a motor, rotating discs, a dust collector, a water bowl, an ozone generator etc, has been developed to clean the stall air. The work principle is that the inside air is sucked through the fan, and the rotating discs make water into fineness spray and blow into the stall. The rest water flows down to the dust collector. In the present study, we measured the dust, ammonia gas, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with On-mode and Off-mode of wet air cleaners. The dust measure was divided into 3 categories, TSP, $PM_{10}$, and $PM_{2.5}$. In summer, the TSP in on-mode were maximum $0.259mg/m^3$ and minimum $0.128mg/m^3$, and the average was $0.195mg/m^3$. These are comparable to the data from Off-mode stall that maximum $0.308mg/m^3$, minimum $0.139mg/m^3$, and average $0.277mg/m^3$. However, $PM_{10}$ and $PM_{2.5}$ showed any significant differences between the tests. The concentrations of ammonia gas in Off-mode stall were maximum 13.8 ppm and minimum 5.9 ppm, and the average was 8.47 ppm. However in On-mode stall the ammonia gas concentrations were maximum 10.5 ppm and minimum 5.5 ppm, and the average was 7.63 ppm. The concentration of ammonia gas in On-mode was 10% in average lower than off-mode stall. Odor was measured by olfactometer. In the Off-mode stall, the odor unit were maximum 420 $Ou/m^3$ and minimum $300\;OU/m^3$, and the average was $367\;OU/m^3$, but in the On-mode stall the odor unit were maximum $330\;OU/m^3$ and minimum $210\;OU/m^3$, and the average was $253\;OU/m^3$. Odor removal efficiency was about 31% in On-mode stall.

  • PDF

자동차 배기가스 유량 및 온도 변화에 따른 열전발전용 열교환기 발열량 특성에 관한 연구 (Thermal Caracteristics of the Automobile Exhaust gas based Heat exchanger with various Exhaust gas Temperature and Mass flow rate)

  • 김대완;기한 에카나야케;이무연
    • 한국산학기술학회논문지
    • /
    • 제19권2호
    • /
    • pp.15-20
    • /
    • 2018
  • 본 논문은 자동차 열전발전용 열교환기에서 배기가스의 유량과 온도 변화에 따른 발열량 특성을 수치적으로 연구하였다. 자동차 열전발전용 열교환기는 내부에 핀을 설치하여 자동차 배기가스에서 나오는 열에너지를 열전소자로 최대 값을 전달할 수 있도록 하였으며, 상용 프로그램인 CAD를 이용하여 설계하였다. 그리고 배기가스의 유량과 온도 변화에 따른 열교환기 발열량 특성을 분석하기 위하여 상용 프로그램인 ANSYS CFX v17.0을 이용하여 배기가스 유량은 0.01, 0.02, 0.03 kg/s로 변화시키고, 배기가스 온도는 400, 450, 500, 550, $600^{\circ}C$로 변화시켜 수치해석 하였다. 결론적으로 열교환기의 입구 측과 출구 측 배기가스 압력 차는 배기가스의 유량에 따라 결정된다. 배기가스 유량이 증가하면 열교환기 입구 측과 출구 측 압력차는 증가하지만, 열교환기 입구 측과 출구 측 배기가스 압력차는 배기가스 온도에 따라 변하지 않는다. 따라서 열교환기 표면 온도를 최대 값으로 얻기 위해서는 배기가스 유량은 낮추고, 배기가스 온도는 높여야 한다는 결론을 도출하였다.

교정용 단일에너지 형광 X-선장의 제작 (Establishment of the Monoenergetic Fluorescent X-ray Radiation Fields)

  • 김장렬;김봉환;장시영;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제23권1호
    • /
    • pp.33-47
    • /
    • 1998
  • 한국원자력연구소 교정시설에 설치되어 있는 MG325 X-선 발생장치와 ISO-4037에서 제시하고 있는 라디에이티 및 필터 8종을 조합하여 8.6 keV 부터 75 keV 까지의 단일에너지 형광 X-선을 제작하였다. 1차 X-선에 의하여 라디에이터에서 발생된 형광 X-선중 $K_{\beta}$를 필터를 사용하여 제거한 후 단지 $K_{\alpha}$만의 형광 X-선 스펙트럼을 고순도 평판형 반도체검출기와 휴대용 다중파고분석기로 분석하였으며 35 cc 전리함을 이용하여 이때의 선량률 (air kerma rates)를 측정하여 계산결과와 비교하였다. 또한 방사선장의 균일도분포를 전리함과 사진현상을 통하여 결정하였으며 산란 X-선의 영향도 측정하여 실제 적용가능성을 검토하였다. 실험결과 순도가 90 % 이상되는 8.6 keV부터 75 keV까지의 단일에너지 형광 X-선을 얻었으며 라디에이터 중심으로부터 43 cm 위치에서의 선량률은 1.91 mGy/h (라디에이터 : Au, 필터 : W)로부터 54.2mGy(라디에이터 : Mo, 필터 : Zr) 까지였다. 선량률 측정지점에서 방사선장의 유효면적은 12 cm ${\times}$ 12 cm로 계측기의 교정이나 개인선량계의 조사에 전혀 문제가 없음을 확인하였고 산란방사선의 영향도 3% 이하였다.

  • PDF