• Title/Summary/Keyword: $CO_2$ generator

Search Result 215, Processing Time 0.032 seconds

Nonlinear Stochastic Stability for Steam Generator Water Level Control System (증기발생기 수위제어의 확률론적 안정성)

  • Park, You-Cho;Chung, Chang-Hyun;Oh, Je-Kyun
    • Nuclear Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.155-164
    • /
    • 1995
  • The steam generator water level control system is studied as a class of randomly sampled nonlinear control systems. The sampling interval and the loop amplification factor are considered as random variables in order to take the operator behavior in account. Stochastic stability using Lyapunov method is used without determining such Lyapunov function. The derived stability criterion is verified with time-domain simulation using the data of CANDU type nuclear power plant, Wolsung 1.

  • PDF

Concentration and Seasonal Variation of Gaseous Nitrous Acid in Seoul Air (서울대기중 아질산기체의 계절별 농도변화)

  • 이용근;김종욱;이동수;백선영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.1
    • /
    • pp.24-31
    • /
    • 1994
  • Hourly variation of gaseous nitrous acid( HNO$_2$) concentration in Seoul air was monitored from Jan. 11 to SeP. 12, Nitrous acid concentration was determined by DS/IC over nine months of observation, HNO$_2$ range from 0.04 ppb to 5.5 ppb. Gor-tex tube as gaseous HNO$_2$generator in this study is thought to be more convenient and reproducible device than previous generator. As a result of NaOH instead of Na$_2$ CO$_3$/NaHCO$_3$ solution as the IC eluent, we could obtain more stable baseline. The concentration of the NaOH eluent was 15 mM . The limit of detection(3$\sigma$) of the liquid- Phase and gas phase nitrous acid of this method are 1.1ng/$m\ell$ , 0.04 n $\ell$ / $\ell$, respectively. The precisions evaluated by 10 replicate analysis of standard solution and standard gas generated are $\pm$1.59, $\pm$2. 89% RSD, respectively. Due to the lack of standard material for air, direct assessment of the accuracy was not possible. This study was applied to the analysis of Seoul ambient air and their results are reported herein.

  • PDF

Analysis of Research for the Actual State and Management of Automated Horticultural Facilities (경북지역 현대화 원예시설의 관리실태 조사분석)

  • 정현교;이기명;박규식
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.174-186
    • /
    • 1996
  • This study was carried out in order to understand the plan, design, constructing and actual condition of management of modernized horticultural facilities in Kyungpook Province which had been constructed from 1992 to 1995 funded by Government support. The aim of this study is to provide reference data for success of the forth project. It was performed by making up a question about driving of project and management condition of equipment after constructing. The results obtained from this study are as follows: 1. 73.5% of facilities horticulture farmhouse recognized that the prospect of greenhouse is bright, but 92.5% of the farmhouse also recognised that they need technical consultation on protected horticulture farming. Therefore, technical educations would must be enhanced about foundation of greenhouse and cultivation technique. 2. The holding times of explanatory meetings, cause of understanding to farmhouse, were one or two times in greenhouse construction, and 62.5% of the farmhouse expressed the insufficiency at the explanation and educational data. For this reason, it was judged that the construction contract had been delayed more than 5 months in 49.3% of the farmhouse after the decision of project budget. 3. In constructing after a contract, the rates of construction delay is 53.4% and defect occurrence is 41.1%. The biggest reasons of construction delay was insufficiency of worker and materials supply. Each percentage is 29.1%. And the reason of defect occurrence is badness of machinery equipment(62.9% ). 4. In management of greenhouse, a pipe-constructed plastic film greenhouse changes plastic film every one and three years because of sticking dust on plastic film. It was needed to about in cleaning technique of coverings. Because that used 3-5 years only half of the expected life span. 5. The order of broken rating in the subsidiary equipment is like this lollop ventilator (42.8%), a general control system(33.3%) especially, in the case of a general control system, the rate of all family can control is 52.7%. so, it is time to develop easy control equipment which every one could use as soon as possible. 6. When choose heat generator as decide capacity, the most priority is the mount of heat generator the percent is 45.5% heat generator and as decide model, the private purchase's percent is 77.3%. It is higher than a public bidding heat generator the percent is 22.7% heat generator when it compare with a public bidding. In the case of $CO_2$ generator, using rate is only 19.0%. The using rate is very low, so it needs education how to use depends on the way of the subsidiary equipment. 7. In the case of seedlings, it is asked to use factory-processed seedling effectively. because it's difficult to get security of labors(58.8%), hoped crops (55.9%) access same crops(29.4%) much more and changing of crops depends on market situation. that is the main reason the lack of knowhow.

  • PDF

Performance evaluation and Applicable Possibility of $H_2O_2$ Gas Generator using Dual Catalyst System (이원 촉매를 이용한 과산화수소 가스발생기 성능평가 및 응용 가능성)

  • Rang Seong-Min;An Sung-Yong;Lim Ha-Young;Kwon Se-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.347-350
    • /
    • 2006
  • The rocket grade hydrogen peroxide has been widely used as a monopropellant in propulsion systems. In the present paper, we described an experimental study of a catalytic reactor that employs two stage catalyst beds to enhance the low temperature performance of the reactor. $K_2MnO_4$ was chosen as the catalyst for the initial stage of the reactor bed for its superior behavior in the low temperature regime. LSC was used for the catalyst of the second stage of the reactor. The gas generator with combined catalyst beds was built and tested to exhibit high decomposition efficiency over 90% and successful cold-start characteristics.

  • PDF

Plan to Develop the Radioactive Waste Certification Program (방사성폐기물인증프로그램 개발 방안)

  • Chung Hee-Jun;Lee Jae-Min;Whang Joo-Ho;Kim Heon;Jeong Yi-Yeong
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.205-210
    • /
    • 2005
  • The proposed regulation for low and intermediate level radioactive waste disposal facility, scheduled to be revised, recommends that the waste generator should verify the radioactive waste conforms to the disposal requirements before disposing of it. According to the regulation, the radionuclide concentration of the radioactive waste, and its physical and chemical characteristics and safety must be confirmed prior to the disposal of low and intermediate level radioactive wastes, and the waste generator is required to deliver this information to the disposal facility operator. In addition, the disposal facility operator must assess the safety of the disposal site to establish the SWAC (Site Specific Waste Acceptance Criteria) in consideration of the characteristics of the site, whereas the waste generator must comply with the criteria in managing, disposing of and delivering low and intermediate level radioactive wastes. To abide by the afore-mentioned regulation and criteria, the waste generator must verify that the radioactive wastes to be disposed of are suitable for disposal before they are transported to the disposal facility, and to this end a radioactive waste certification program must be developed. This study conducted an in-depth analysis of the radioactive waste certification programs enforced in countries advanced in atomic energy to develop a draft of a certification program applicable to local power plants, and the program is currently applied as pilot to Uljin Power Plants No. 1 & 2 to prove its applicability. This study is going to analyze the results of the pilot application with a view to developing a radioactive waste certification program suitable to local conditions.

  • PDF

Analysis of activated colloidal crud in advanced and modular reactor under pump coastdown with kinetic corrosion

  • Khurram Mehboob;Yahya A. Al-Zahrani
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4571-4584
    • /
    • 2022
  • The analysis of rapid flow transients in Reactor Coolant Pumps (RCP) is essential for a reactor safety study. An accurate and precise analysis of the RCP coastdown is necessary for the reactor design. The coastdown of RCP affects the coolant temperature and the colloidal crud in the primary coolant. A realistic and kinetic model has been used to investigate the behavior of activated colloidal crud in the primary coolant and steam generator that solves the pump speed analytically. The analytic solution of the non-dimensional flow rate has been determined by the energy ratio β. The kinetic energy of the coolant fluid and the kinetic energy stored in the rotating parts of a pump are two essential parameters in the form of β. Under normal operation, the pump's speed and moment of inertia are constant. However, in a coastdown situation, kinetic damping in the interval has been implemented. A dynamic model ACCP-SMART has been developed for System Integrated Modular and Advanced Reactor (SMART) to investigate the corrosion due to activated colloidal crud. The Fickian diffusion model has been implemented as the reference corrosion model for the constituent component of the primary loop of the SMART reactor. The activated colloidal crud activity in the primary coolant and steam generator of the SMART reactor has been studied for different equilibrium corrosion rates, linear increase in corrosion rate, and dynamic RCP coastdown situation energy ratio b. The coolant specific activity of SMART reactor equilibrium corrosion (4.0 mg s-1) has been found 9.63×10-3 µCi cm-3, 3.53×10-3 µC cm-3, 2.39×10-2 µC cm-3, 8.10×10-3 µC cm-3, 6.77× 10-3 µC cm-3, 4.95×10-4 µC cm-3, 1.19×10-3 µC cm-3, and 7.87×10-4 µC cm-3 for 24Na, 54Mn, 56Mn, 59Fe, 58Co, 60Co, 99Mo, and 51Cr which are 14.95%, 5.48%, 37.08%, 12.57%, 10.51%, 0.77%, 18.50%, and 0.12% respectively. For linear and exponential coastdown with a constant corrosion rate, the total coolant and steam generator activity approaches a higher saturation value than the normal values. The coolant and steam generator activity changes considerably with kinetic corrosion rate, equilibrium corrosion, growth of corrosion rate (ΔC/Δt), and RCP coastdown situations. The effect of the RCP coastdown on the specific activity of the steam generators is smeared by linearly rising corrosion rates, equilibrium corrosion, and rapid coasting down of the RCP. However, the time taken to reach the saturation activity is also influenced by the slope of corrosion rate, coastdown situation, equilibrium corrosion rate, and energy ratio β.

Computational Prediction of Speed Performance for a Ship with Vortex Generators (와류생성기를 부착한 선박의 속도성능에 대한 수치적 추정)

  • Choi, Jung-Eun;Kim, Jung-Hun;Lee, Sang-Bong;Lee, Hong-Gi
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.46 no.2
    • /
    • pp.136-147
    • /
    • 2009
  • The computational prediction method of speed performance for a ship with vortex generators is proposed. The Reynolds averaged Navier-Stokes equation has been solved together with the application of Reynolds stress turbulence model. The computations are carried out under identical conditions of the experimental method, i.e., towing and self-propulsion calculations without and with vortex generators. The speed performance in full scale is obtained through analyzing the computational results in model scale according to the revised model-ship performance analysis method of ITTC'78 with considering the vortex generators into account. The characteristics of resistance, self-propulsion and wake characteristics on the propeller plane are investigated. The proposed computational prediction clearly shows the effect of vortex generators and can be applicable to the design tool for vortex generators.

Recent Trend to the Forging Technology of Power Plant Components and Status of Forging Company (발전용 소재 단조기술 및 국내 단조업계 동향)

  • Kim, J.T.;Chang, H.S.;Kim, D.K.;Kim, Y.D.;Kim, D.Y.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.05a
    • /
    • pp.38-41
    • /
    • 2007
  • The increase of $CO_2$ emission by increasing of fossil fuel usage has been understood a major cause of global warming. The supply of electric energy is heavily dependent on the massive thermal power and nuclear power plant before developing the renewable energy to supply the electric energy stably at a low price. The large and sound forged components of pressure vessel, turbine and generator are widely used in power plant such as wind power, hydroelectric power generation, nuclear power and thermal power plant. This paper is discussed the trend of manufacturing technology for pressure vessel and turbine to satisfy the required condition of utility company. It is also introduced a strategy of forging industry to cope with carbon tax.

  • PDF

Development of a Highly Efficient Boiler System Using a Diesel Engine

  • Lee, D.-H;Lee, D.-Y;Jo, M.-C;Cho, H.-N;Kim, Y.-S
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.367-375
    • /
    • 2004
  • We have developed a highly efficient boiler system using the 2,600cc Diesel engine. In this system, the co-generation concept is utilized in that the electric power is produced by the generator connected to the engine, and waste heat is recovered from both the exhaust gases and the engine itself by the shell-and-tube heat exchangers. The heat exchanger connected to the engine outlet is specially designed such that it not only recovers waste heat effectively from the exhaust gases, but significantly reduces an engine noise. It is found that the total efficiency(thermal efficiency plus electric power generation efficiency) of this system reaches maximum 96.3% which is about 15% higher than the typical Diesel engine boiler system currently being used worldwide.

An Experimental Study of Ventilation Effectiveness in Mechanical Ventilation systems using a Tracer Gas Method

  • Lee, Jae keun;Kang, Tae-Wook;Lee, Kam-Gyu;Cho, Min-Chul;Shin, Jin-Hyuk;Kim, Seong-Chan;Koo, Jeong-Hwan;Lee, Jong ho
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.11
    • /
    • pp.1286-1295
    • /
    • 2000
  • The ventilation effectiveness is evaluated as a function of air exchange rate and supply / extract locations in a simplified model chamber using a tracer gas technique of CO$_2$ gas injected into a supply duct. Ventilation systems consist of supply and extract fans, a CO$_2$gas generator, a CO$_2$gas analyzer and a test chamber. The ventilation effectiveness is evaluated using a step-down method based on ASTM Standard E741-83. The room mean age of the model chamber is decreased with increasing air exchange rate fanged from 6to 10 air changes per hour. The ventilation effectiveness of the mechanical inlet/natural extract system is better than that of the mechanical extract system.

  • PDF