• Title/Summary/Keyword: $CO_2$ generator

Search Result 215, Processing Time 0.032 seconds

Study on optimization of liquid carbonation pilot plant (system) using sludge water of ready-mixed concrete (레미콘회수수를 이용한 액상탄산화 Pilot plant(System) 최적화에 관한 연구)

  • Kim, Jae Gang;Shin, Jae Ran;Kim, Hae Gi;Kang, Ho Jong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.239-246
    • /
    • 2016
  • In this study, recycling sludge water of Ready-mixed concrete, and was carried out to optimize the system for recycling of the $CO_2$. The most important process in the liquid phase using a carbonation reaction can be recovered ready-mixed concrete is a process for the $Ca^{2+}$ release. $Ca^{2+}$ concentration of the experiment relative to the pH being lowered by the acidic substance during elution was performed. $CO_2$ was trapped in the MEA solution using a generator flue gas. In ready-mixed concrete can be synthesized $CaCO_3$ up to 11kg/1ton. The resulting $CaCO_3$ analysis results show that it is possible to use paper industry.

Spread Spectrum Clock Generator with Multi Modulation Rate Using DLL (Delay Locked Loop) (DLL을 이용한 다중 변조 비율 확산대역클록 발생기)

  • Shin, Dae-Jung;Yu, Byeong-Jae;Kim, Tae-Jin;Cho, Hyun-Mook
    • Journal of IKEEE
    • /
    • v.15 no.1
    • /
    • pp.23-28
    • /
    • 2011
  • This paper describes design and implementation of a spread spectrum clock generator(SSCG). The proposed architecture generates the spread spectrum clock controlling a input voltage signal for VCDL(Voltage Controlled Delay Line). Spread charge pump is controlled by the SSC modulation logic block provides a control signal to VCDL through LPF in DLL. By using this architecture, chip area and power consumption can be reduced because it is not necessary additional circuit to control modulation rate. This circuit has been designed and fabricated using the UMC 0.25um CMOS technology. The chip occupies an area of 290${\times}$120um^2.

A Stable Operation Strategy in Micro-grid Systems without Diesel Generators

  • Choi, Sung-Sik;Kang, Min-Kwan;Lee, Hu-Dong;Nam, Yang-Hyun;Rho, Dae-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.114-123
    • /
    • 2018
  • Recently, as one of the countermeasures to reduce carbon dioxide($CO_2$) for global warming problems, operation methods in micro-grid systems replacing diesel generator with renewable energy sources including wind power(WP) and photovoltaic(PV) system have been studied and presented in energetic manners. However, it is reported that some operation problems in micro-grid systems without diesel generator for carbon-free island are being occurred when large scaled WP systems are at start-up. To overcome these problems, this paper proposes an operation strategy in micro-grid systems by adapting control devices such as CVCF(constant voltage constant frequency) ESS(energy storage system) for constant frequency and voltage regulation, load control ESS for balancing demand and supply and SVC(static-var compensator) for reactive power compensation. From the simulation results based on the various operation scenarios, it is confirmed that the proposed operation strategy in micro-grid systems without diesel generators is a useful tool to perform a stable operation in micro-grid systems without diesel generator and also make a contribution to reduce carbon dioxide in micro-grid systems.

A Study on the Variation of Anion Exchange Membrane of Hydrogen Generator of Alkaline Electrolysis (알칼리 수전해 수소제조의 이온 교환막 변화 분석)

  • Byun, Chang-Sub;Lim, Soo-Gon;Kim, Su-Kon;Shin, Hoon-Kyu
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.7
    • /
    • pp.563-566
    • /
    • 2013
  • We investigated the variation of anion exchange membrane of hydrogen generator of alkaline electrolysis. We detected the variation of elements and change of anion exchange membrane using EDS and FE-SEM. We detected two different sites of membrane because of different structure of membrane. $Sp_1$ shows that the distribution ratio of C, O, Al is 98% very higher than $Sp_2$ of 78%. Especially, the main elements of STS316 which is P, S, Fe, Ni were more detected at $Sp_2$ than $Sp_1$. We think that this result depends on the structure of membrane. This also affect the resistance, lifetime of membrane and decrease the efficiency of hydrogen production. We hope that this article is a foundation of developing of hydrogen production technology.

The Best Generation Mix considering CO2 Air Pollution Constraint ($CO_2$ 배출량제약을 고려한 최적전원구성)

  • Lee, Sang-Sik;Tran, TrungTinh;Kwon, Jung-Ji;Choi, Jae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.149-151
    • /
    • 2005
  • A new approach considering CO2 air pollution constraints in the long-term generation mix is proposed under uncertain circumstances. A characteristic feature of the presented approach in this paper is what effects give the air pollution constraints in long term best generation mix. Best generation mix problem is formulated by linear programming with fuel and construction cost minimization with load growth, reliability (reserve margin rate) and air pollutionconstraints. The proposed method accommodates the operation of pumped-storage generator. It was assumed in this study that the construction planning of the hydro power plants is given separately from the other generation plans. The effectiveness of the proposed approach is demonstrated by applying to the best generation mix problem of KEPCO-system, which contains nuclear, coal, LNG, oil and pumped-storage hydro plant multi-years.

  • PDF

Development of Power Conditioner Unit for 2MW Doubly-Fed Induction-type Wind Generator (2MW급 이중여자 유도형 풍력발전기용 Power Conditioner Unit 개발)

  • Jeong, Byoung-Chang;Kim, Hee-Jung;Chung, Yong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1236-1237
    • /
    • 2007
  • 본 논문에서는 이중여자 유도형 풍력발전기를 제어하기 위한 Power Conditioner Unit을 개발하였다. Power Conditioner Unit은 크게 전력변환을 담당하는 컨버터와 제어기로 구성된다. 컨버터는 2대를 back-to-back 구조로 연결하여 전력을 양방향으로 제어한다. 제어기는 계통의 전압 상태, 발전기의 회전속도와 발전량, 그리고 계통 운영자의 요구에 따라서 발전기의 발전량과 발전 시스템의 출력 역률 또는 계통전압을 제어한다.

  • PDF

A Spread Spectrum Clock Generator for SATA II with Rounded Hershey-Kiss Modulation Profile

  • Moon, Yong-Hwan;Lim, Wan-Sik;Kim, Tae-Ho;Kang, Jin-Ku
    • Journal of IKEEE
    • /
    • v.15 no.2
    • /
    • pp.129-133
    • /
    • 2011
  • A spread spectrum clock generation is an efficient way to reduce electro-magnetic interference (EMI) radiation in modern mixed signal chip systems. The proposed circuit generates the spread spectrum clock by directly injecting the modulation voltage into the voltage-controlled oscillator (VCO) current source for SATA II. The resulting 33KHz modulation profile has a Hersey-Kiss shape with a rounded peak. The chip has been fabricated using $0.18{\mu}m$ CMOS process and test results show that the proposed circuit achieves 0.509% (5090ppm) down spreading at 1.5GHz and peak power reduction of 10dB. The active chip area is 0.36mm ${\times}$ 0.49mm and the chip consumes 30mW power at 1.5GHz.

$CO_2$ Emission Calculation of D Thermal Power Plant using Performance Test Results (성능시험 결과를 이용한 D발전소의 $CO_2$ 대기배출량 계산)

  • Moon, Hong-Gyu;Lee, Sang-Joong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.341-344
    • /
    • 2007
  • Kyoto Protocol against global warming came into effect in Feb 2005. Korea is expected to be put under obligation to decrease the $CO_2$ emission from 2013. Because the electric power plants burning fossil fuel occupy 25% of national $CO_2$ emission, calculating the amount is very important. This paper presents ; - a brief procedure of performance test of D thermal power plant - calculation and comparison of $CO_2$ emission of D power plant w.r.t the generator output for LNG and residual oil using the a, b, c coefficients obtained by the performance test - and a brief description on currently used chemical method for calculation of $CO_2$ emission

  • PDF

Risk Assessment of Compressor Room for Next Generation LNG Carriers (차세대 LNG선 컴프레서룸의 위험성 해석)

  • Moon, Ki-Ho;Song, Seok-Lyong;Jeong, Sam-Heon;Ha, Jong-Phil
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2008.09a
    • /
    • pp.76-83
    • /
    • 2008
  • New and more efficient propulsion systems are required for LNG carriers. One of the proposed systems is a combination of a gas turbine with a heat recovery steam generator. This system constitutes a novel approach, which needs to be analyzed by system analysis and risk assessment to compensate for the lack of field experience. Of specific concern is the high pressure fuel supply system. This paper describes the dispersion and fire analysis performed to identify for safety and design improvement of proposed system.

  • PDF

Development of a 300W Generator for Lightweight Wind Turbine

  • Lee, Hee-Kune;Lee, Hee-Joon;Kim, Sun-Hyung
    • The Journal of Korean Institute of Information Technology
    • /
    • v.15 no.12
    • /
    • pp.181-188
    • /
    • 2017
  • As a population of leisure activities grows and diversifies, there is a great demand for portable and environment-friendly power generation systems. A small wind power generation system is emerging as a suitable power generation equipment to meet these needs. The most important thing when developing a small portable wind turbine is to reduce the weight of the generator and increase the efficiency. The existing 300W wind turbine generator weighs about 10kg, which is heavy to carry. Therefore, a new generator weighing less than 4kg to make it easy to carry with high efficiency has been developed. In addition, considering complicated characteristics of wind volume and topography of Korea, a small wind turbine that can be used in urban and rural areas individually was constructed. Through basic designing and optimization, the lightweight and efficient generator was manufactured. It is a 300W wind turbine designed and fabricated with reduced weight as a prototype. The average output voltage of the generator was 24.7V at 900rpm no-load test. On a load test with the average line voltage 36.8V and the average phase current 2.62A, when the mechanical input was 339.84W, an average voltage output of the generator was measured as 289.5W with efficiency of 85.18%. The generator weight was 3.84kg.