• Title/Summary/Keyword: $CO_2$ concentration distribution

Search Result 314, Processing Time 0.026 seconds

Analysis of Comfortable Environment in the Classroom with Humidification and Ventilation in Winter (겨울철 가습 및 환기에 따른 교실내 쾌적환경 분석)

  • Sheng, Nai-Li;Cheong, Seong-Ir;Lee, Jae-Keun;Park, Jong-Hoon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1213-1219
    • /
    • 2008
  • This experimental study was to analyze thermal comfort and indoor air quality(IAQ) with ventilation and humidification in the classroom when system air conditioner was operated. The thermal comfort was estimated by the PMV index and the concentration of $CO_2$ and total suspended particle(TSP) were measured and compared with ventilation and humidification. As a result, the class room temperature distribution was $2{\sim}5^{\circ}C$ low during operating ventilation system and humidification. At 60% RH, PMV values of measuring points were ranged from +0.5 to -0.5 indicating optimal the range of thermal comfort. The average concentration of $CO_2$ gas and TSP were reduced 645 ppm, 0.17 mg/$m^3$ respectively, during operating the ventilation system. From the results, to maintain comfortable environment in the heated classroom, the ventilation and humidification were needed in winter season.

  • PDF

Characteristics of Air Pollution at Kimhae (김해지방의 대기오염 특성)

  • 박종길;김종필;김지형
    • Journal of Environmental Science International
    • /
    • v.8 no.1
    • /
    • pp.33-43
    • /
    • 1999
  • This paper aims to describe the characteristics of air pollution using air pollutants concentration and meteorological data observed at Kimhae from December 1996 to November, 1997. The results are as follows : The concentration distribution of sulfur dioxide($SO_2$), carbon monoxide(CO), particulate matter(PM-10), and nitrogen dioxide($NO_2$) is high during the late fall and winter and low during the summer, but ozone concentration is low during the winter season and high during summer season except Jangma period and these distributions appear to be closely connected with insolation and the number of clear day. Diurnal variation of concentrations for sulfur dioxide, particulate matter, and carbon monoxide are high during the rush hours and nighttime and low during the daytime and these variations are distinct toward the winter season. And diurnal variation of nitrogen dioxide concentration has also same pattern and these patterns are closely related to the increasing traffic volume at rush hours. Diurnal variation of ozone concentration is generally increase for daytime and decrease for the late afternoon and are closely related to the insolation and photochemical reaction. The 24 hour average concentrations of air pollutant observed at Kimhae represented a positive correlation and a negative correlation for $O_3$ and also a negative correlation for the meteorological elements such as wind speed and cloud cover.

  • PDF

CFD Analysis on the Effect of the Nozzle Arrays and Spray Types in the Hydrogen Peroxide Mixing Quencher to Improve the Mixing Efficiency (과산화수소 혼합냉각기 내의 노즐배치 및 가스분사 방식 변화에 따른 혼합율 개선에 대한 전산해석적 연구)

  • Koo, Seongmo;Chang, Hyuksang
    • Clean Technology
    • /
    • v.23 no.1
    • /
    • pp.42-53
    • /
    • 2017
  • Numerical analysis was done to evaluate the fluid distribution inside of the mixing quencher to increase the reaction efficiency of the aqueous hydrogen peroxide solution in the scrubbing column which is used for simultaneous desulfurization and denitrification. Effective injection of the aqueous hydrogen peroxide ($H_2O_2$) solution in the mixing quencher has major effects for improving the reaction efficiency in the scrubbing column by enhancing the mixing of the aqueous $H_2O_2$ solution with the exhaust gas. The current study is to optimize the array of nozzles and the spray angles of the aqueous $H_2O_2$ solution in the mixing quencher by using the computational method. Main concerns of the analysis are how to enhance the uniformity of the $H_2O_2$ concentration distribution in the internal flow. Numerical analysis was done to check the distribution of the internal flow in the mixing quencher in terms of RMS values of the $H_2O_2$ concentration at the end of quencher. The concentration distribution of $H_2O_2$ at the end of is evaluated with respect to the different array of the nozzle pipes and the nozzle tip angles, and we also analyzed the turbulence formation and fluid mixing in the zone. The effect of the spray angle was evaluated with respect to the mixing efficiency in different flow directions. The optimized mixing quencher had the nozzle array at location of 0.3 m from the inlet duct surface and the spray angle is $15^{\circ}$ with the co-current flow. The RMS value of the $H_2O_2$ concentration at the end of the mixing quencher was 12.4%.

Effects of Diffusibility of Bubbling Tablet Herbicide Formulations for Paddy Rice (수도용 발포성정제 제초제의 확산성에 미치는 영향)

  • Kim, Man-Ho;Ryang, Kwang-Rok;Lee, Chang-Hyeuk;Shim, Jae-Weon;Kim, Kyung-Hyun;Yoon, Cheol-Su;You, Yong-Man;Pyon, Jong-Yeong
    • The Korean Journal of Pesticide Science
    • /
    • v.9 no.4
    • /
    • pp.401-410
    • /
    • 2005
  • A series of studies involving formulation processes, bubbling activity test, diffusibility test and biological efficacy test was undertaken to develop Jumbo herbicide formulations in paddy rice field. Gas evolution speed from the tablets prepared by different organic acids was in the order of oxalic acid, malonic acid, citric acid, and tartaric acid. The total volume of evolved gas from the tablet and diffusibility of the active ingredient in the submerged water were increased with increase of water temperature; the volume from 1 g of tablet at 10, 15, 25 and $30^{\circ}C$ for 5 minutes after immersion into water was 20, 25, 28, 45, 57 mL, respectively. The concentration of halosulfuron-methyl and pyriminobac-methyl in submerged water at 5, 15, 20 and $30^{\circ}C$ at the 2.4 m distance from the applied spot of the tablet was 20, 48, 85, and 97% of the concentration of treated spot, respectively. The evolved gas volume from the tablets was not affected by pH of submerged water. The concentration of halosulfuron-methyl in different sizes of submerged water within 24 hours after treatment of the tablet was maintained 0.16 ppm, which is ideal concentration at standard dosage regardless of the submerged water area. The concentration of pyriminobac-methyl was also uniformly dispersed in the water within 24 hours after applying it into the submerged water. The wind velocity of 5 m $sec^{-1}$ on concentration distribution of halosulfuron-methyl and pyriminobac-methyl in the submerged water 24 hours after treatment was not influenced; an equal concentration in the up the wind and down the wind from the applied spot was maintained. Spot treatments of one tablet formulations(5 g) including 4 times higher dosage at 4 different spots resulted in even concentration distribution of active ingredient in the water 24 hours after applying it into the submerged water.

A Quantitative Analysis of Air Purification Effectiveness on Urban Forest Considering the Spatial Distribution of Pollutant Concentration (오염농도의 공간적 분포를 고려한 도시림의 대기정화기능 계량화)

  • Choi, Chul-Hyun;Lee, Woo-Sung;Jung, Sung-Gwan
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.15 no.2
    • /
    • pp.71-85
    • /
    • 2012
  • The purpose of this study is to estimate air purification effectiveness considering the improvement of its methods related atmospheric environment. The air purification effectiveness is estimated in Daegu, one out of Korean Metropolitan cities because air pollution is getting serious in a heavily urbanized area. The absorption of pollutants is calculated by considering spatial heterogeneity that was not considered previous studies and the spatial resolution of air dispersion modeling is also improved by kriging method. According to the type and distribution of urban forest, total 26 kinds of plant communities were distributed with Pinus densiflora community, Pinus densiflora-Quercus mongolica community, Pinus densiflora-Quercus acutissima community and other kinds of communities in the study area. In the results of estimating the $CO_2$ absorption amount for identification of the air purification effectiveness on urban forest, the annual absorption amount was total 108,155t/yr. Also, the annual absorption amounts of $NO_2$ and $SO_2$ were total 183.5 ton and 410.2 ton respectively. The findings from this study can confirm the differences of pollutant absorption by concentration that could not identify if spatial distribution of pollutant concentration had not been considered.

An Experimental Study on the Drop Distribution and the Combustion Characteristics with different Bluff-body Geometries (보염기 형상에 따른 연료액적분포와 연소특성에 관한 실험적 연구)

  • Hwang, S.H.;Kim, D.J.
    • Journal of ILASS-Korea
    • /
    • v.9 no.2
    • /
    • pp.1-8
    • /
    • 2004
  • This work was performed to investigate the distribution of the fuel droplet size around the bluff-body and the combustion characteristics. The geometry of the bluff-body influenced the spray shape and the combustion characteristics. Diameters of the bluff-body in this experiment are 6, 8, and 10 mm and the impingement $angles({\theta})\;are\;30^{\circ},\;60^{\circ},\;and\;90^{\circ}$. The measurement points were at the distances of 20 and 30 mm axially from the nozzle. The SMD and Rosin-Rammler distribution was acquired by image processing technique (PMAS), and the mean temperatures were measured by thermocouple. The results obtained are as follows; In the condition of ${\theta}=60^{\circ}$, the values of SMD are not greatly varied compared to the other conditions. As the impingement angle of bluff-body was increased, the high temperature region was wider along radial direction. When the air-fuel ratio was increased, the CO concentration was decreased.

  • PDF

Effect of Air Velocity on Combustion Characteristics in Small-Scale Burner

  • Laryea, Gabriel Nii;No, Soo-Young
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2005
  • This paper presents the combustion characteristics of hydrocarbon fuel from a conventional pressure-swirl nozzle of a small-scale burner. The nozzle has orifice diameters of 0.256 mm and liquid flow rates ranging from 50 to 64 mL/min were selected for the experiments. The furnace temperature distribution along the axial distance, the gas emission such as CO, $CO_2$, NOx, $SO_2$, flue gas temperature, and combustion efficiency were studied. The local furnace and flue gas temperatures decreased with an increase in air velocity. At injection pressures of 1.1 and 1.3 MPa the maximum furnace temperatures occurred closer to the burner exit, at an axial distance of 242 mm from the diffuser tip. The CO and $CO_2$concentrations decreased with an increase in air velocity, but they increased with an increase in injection pressure. The effect of air velocity on NOx was not clearly seen at low injection pressures, but at injection pressure of 1.3 MPa it decreased with an increase in air velocity. The effect of air velocity on $SO_2$ concentration level is not well understood. The combustion efficiency decreased with an increase in air velocity but it increased with an increase in injection pressure. It is recommended that injection pressure less than 0.9 MPa with air velocity not above 8.0 m/s would be suitable for this burner.

  • PDF

Effect of Air Velocity on Combustion Characteristics Scale Burner

  • Laryea, Gabriel Nii;No, Soo-Young
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • v.10 no.1
    • /
    • pp.76-82
    • /
    • 2005
  • This paper presents the combustion characteristics of hydrocarbon fuel from a conventional pressureswirl nozzle of a small-scale burner. The nozzle has orifice diameters of 0.256 mm and liquid flow rates raging from 50 to 64 mL/min were selected for the experiments. The furnace temperature distribution along the axial distance, the gas emission such as CO, $CO_2,\;NOx,\;S0_2,$ flue gas temperature, and combustion efficiency were studied. The local furnace and flue gas temperatures decreased with an increase in air velocity. At injection pressures of 1.1 and 1.3 MPa the maximum furnace temperatures occurred closer to the burner exit, at an axial distance of 242 mm from the diffuser tip. The CO and $CO_2$ concentrations decreased with an increase in air velocity, but they increased with an increase in injection pressure. The effect of air velocity on NOx was not clearly seen at low injection pressures, but at injection pressure of 1.3 MPa it decreased with an increase in air velocity. The effect of air velocity $SO_2$ concentration level is not well understood. The combustion efficiency decreased with an increase in air velocity but it increased with an increase in injection pressure. It is recommended that injection pressure less than 0.9 MPa with air velocity not above 8.0 m/s would be suitable for this burner.

  • PDF

An experimental Study of the Effect of MTBE contents on Exhaust Emissions and Fuel Economy of MPI and GDi Vehicles (MTBE 함량 변화가 MPI 및 GDi 차량의 배출가스 및 연비에 미치는 영향에 대한 실험적 연구)

  • Song, Hoyoung;Lee, Minho;Kim, Kiho;Lim, Taeyoon;Kim, Hongjip
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.159-169
    • /
    • 2016
  • In this study, the effects of MTBE contents as oxygenates in gasoline on exhaust emissions and fuel economy in MPI and GDi vehicles have been investigated. Various oxygen contents have been selected such as 0, 1.0, 2.3 and 2.7 wt%. FTP-75 and HWFET modes as fuel economy test methods which are widely used in Republic of Korea and US were applied to investigate exhaust emissions from the test vehicles. Emissions of CO, NMHC and NOx did not show significant correlation with oxygen contents in gasoline fuels, although having slight difference with these contents. In addition, CO2 emissions were not significantly changed with respect to oxygen content. But in case of warm-up and FTP-75 and HWFET modes including high speed regimes, CO2 emissions showed inverse correlation with oxygen contents. Particulate number concentration was inversely proportional to the oxygen contents, having the minimum value at the condition of 2.3 wt%. In case of fuel economy through carbon balance method, the highest value has been obtained at 2.3 wt% and there was positive correlation with oxygen contents and fuel economy.

A Study on the Chemical Powdering Process of Polypropylene Resin for Anti-slip Floor Paint (미끄럼 방지 바닥 도료용 폴리프로필렌 수지의 화학적 분쇄에 관한 연구)

  • Kim, D.I.;Chung, H.Y.;Hwang, S.H.;Cho, I.S.;Youn, K.J.;Cho, B.S.;Kim, K.K.;Yun, K.J.
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.78-83
    • /
    • 2012
  • In this study, some experimental results of the peroxide-degradation process of polypropylene(PP) in a co-rotating twin-screw extruder to produce controlled rheology polypropylene(CRPP) are presented. The peroxide was dicumyl peroxide(DCP) and the concentration of DCP was in the range 0-0.3 wt%. It was found that the rheological properties of PP change significantly during reactive extrusion. Melt flow index(MFI) increased with DCP concentration. Intrinsic viscosity decreases with increasing DCP concentration. From dynamic rheological data, number average molecular weight(Mn), weight average molecular weight(Mn) and molecular weight distribution(MWD) were calculated. Results indicated that Mw decreases and MWD becomes narrower with increasing peroxide concentration. Especially, particle size distribution of CRPP decreases with increasing DCP concentration by chemical powdering process, and anti-slip floor paint, CRPP(DCP 0.2 wt%) powder by 10phr was friction coefficient 2.15 ${\mu}$, abrasion resistance 511.18%.