• 제목/요약/키워드: $CO_2$ Transport

검색결과 736건 처리시간 0.024초

Nanoscale microstructure and magnetic transport in AlN/Co/AlN/Co... discontinuous multilayers

  • Yang, C.J.;Zhang, M.;Zhang, Z.D.;Han, J.S.
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2003년도 하계학술연구발표회 및 한.일 공동심포지엄
    • /
    • pp.21-21
    • /
    • 2003
  • Microstructure and magnetic transport phenomina in rf sputtered AlN/Co type ten-layered discontinuous films of nanoscaled [AlN (3 nm)/Co (t nm)]...$\sub$10/ with t$\sub$Co/=1.0∼2.0 nm have been investigated. The microstructure and tunneling magnetic resistance of the samples are strongly dependent on the thickness of Co layer. Negative tunneling magneto-resistance due to the spin-dependent transport has been observed along the current-in-plane configuration in the samples having the Co layers below 1.6 nm thick. When the thickness of Co layer was less than 1,2 nm, randomly oriented granular Co particles were completely isolated and embedded in amorphous AlN matrix, and the films showed the superparamagnetic behavior with a high MR value of Δ$\rho$/$\rho$$\sub$0/=1.8 %. As t$\sub$Co/ increases, a transition from the regime of co-existence of superparamagnetic and ferromagnetic behaviors to ferromagnetic behavior was observed. Tunneling barrier called "decay length for tunneling" for the films having the thickness of Co layer from 1.4 to 1.6 nm was measured to be ranged from 0.004 to 0.021 ${\AA}$$\^$-1/.

  • PDF

RORO선을 이용한 수출입컨테이너화물의 연안운송에 의한 온실가스 배출량 삭감에 관한 연구 (Study on the reduction of green house effect gas emission by RORO ship coastal transport of import-export container cargo)

  • 김상현;고창두
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제6권3호
    • /
    • pp.16-25
    • /
    • 2003
  • 본 논문에서는 RORO선을 이용한 연안운송에 따른 CO₂가스 배출량과 NOx가스 배출량의 삭감 효과에 대하여 고찰한다. 먼저 국내 CO₂가스 배출량과 수출입 컨테이너화물의 물동량에 대하여 고찰한다. 다음에 RORO선의 특성, CO₂가스 배출량 기준과 NOx가스 배출량 기준에 대하여 고찰한다. 또한 경인지역과 부산항 사이의 수출입 컨테이너 화물의 운송에 있어서 도로운송을 연안운송으로 전환한 경우의 CO₂가스 배출량과 NOx가스 배출량 삭감 효과에 대하여 계산한다. 마지막으로 RORO선의 적재율과 연안운송 분담율 변화에 따른 CO₂가스 배출량과 NOx가스 배출량 변화에 대하여 조사한다. 본 논문의 결과를 통하여 수출입컨테이너 화물의 운송을 도로운송으로부터 RORO선을 이용한 연안운송으로 전환하는 것이 CO₂가스 배출량 삭감에는 효과적이나 NOx가스 배출량 삭감에는 큰 효과가 없는 것을 확인하였다.

  • PDF

3차원 지하수 유동과 반응성용질이동 모델을 활용한 우라늄 흡착 및 이동에 관한 개념 모델링 (Conceptual Modeling on the Adsorption and Transport of Uranium Using 3-D Groundwater Flow and Reactive Transport Models)

  • 최병영;고용권;윤성택;김건영
    • 자원환경지질
    • /
    • 제41권6호
    • /
    • pp.719-729
    • /
    • 2008
  • 본 연구에서는 지구화학 모델을 활용하여 지하수 환경에서의 우라늄의 존재 형태, 흡착 및 이동 특성을 모사해 보았다. 흡착에 의한 우라늄의 지연 이동을 효과적으로 모사하기 위하여 3차원 지하수 유동 모델과 반응성 용질 이동 모델을 활용하였다. 모사 결과, $pCO_2=10^{-3.6}$조건에서 대부분의 우라늄 흡착(최대 99.5%)은 pH 5.5와 띠에서 발생하였다. $pCO_2$$10^{-2.5}$인 경우 우라늄이 대부분 흡착되는 pH범위는 6에서 7사이로 매우 좁았으며, 반면 $pCO_2=10^{-4.5}$인 경우에는 흡착되는 pH가 범위가 상대적으로 넓어 pH 5.5에서 8.5사이에서 대부분 흡착되었다. 음이온 화합물을 고려한 경우에는 pH 6 이하에서는 불소착물의 형성에 의해 우라늄 흡착이 감소하였다. 본 연구를 통하여, 우라늄 이동이 pH, $pCO_2$ 및 음이온의 종류와 농도 등 지하수의 지화학적 조건에 의해 상당히 영향을 받음을 알 수 있었다. 향후 여러 부지 조사 및 평가와 관련하여 우라늄 및 기타 유해성 화합물의 환경 영향을 예측하는데 있어 지구화학 모델이 중요한 도구로 활용되어야 할 것이다.

KN-12 운반용기를 이용한 고리 사용후핵연료 소내수송.저장 (On-Site Transport and Storage of Spent Nuclear Fuel at Kori NPP by KN-12 Transport Cask)

  • 정성환;백창열;최병일;양계형;이대기
    • 방사성폐기물학회지
    • /
    • 제4권1호
    • /
    • pp.51-58
    • /
    • 2006
  • 고리 원전 사용후핵연료 저장조의 저장용량을 확보하기 위하여 2002년부터 사용후핵연료 운반용기를 이용하여 400다발 이상의 PWR 사용후핵연료 집합체를 원전부지 내에 수송, 저장하였다. 이를 위하여 KN-12 운반용기, 관련장비 및 수송차량으로 구성되는 수송시스템을 구성하였다. KN-12 운반용기는 국내 원자력법 및 IAEA의 수송규정에 따라 설계, 제작되고, 정부로부터 인허가를 획득하였으며, 취급장비 역시 관련규정에 따라 구비하였다. 수송 저장작업은 2 대의 운반용기를 동시에 투입하여 수행하였으며, 모든 작업공정에 대하여 엄격한 품질관리 및 방사선 안전관리를 수행하여 수송 안전성을 확보하고 신뢰도를 제고하였다.

  • PDF

철도물류활성화를 위한 DMT 수송시스템 개발에 관한 연구 (A Study on DMT Transport System for Rail Logistics)

  • 김종만;이용상
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1691-1707
    • /
    • 2009
  • These days, environment has became more and more important global issues including Climate Change Convention which 40 developed countries have to decrease CO2 emission by 5.2% compared with 1990 emission. Rail transport in Korea are becoming more important as a solution for environment and energy owing to high energy consumption country. Rail transport is environment-friendly mode compared with truck mode (energy consumption 14.2 times, CO2 emission 13.4 times), but it has door-to-door problem and "DMT transport system for rail logistics" can be a solution for this problem and this system can lead to environment-friendly transport mode by rail. This study will review the background of worldwide and Korean DMT system, customers' needs, and analyze transport cost with other transport mode. Through theses kinds of review and analysis, this study will propose DMT terminal, DMT rolling stock, and DMT operation system.

  • PDF

Gas Separation Membranes Containing $Re_6Se_8(MeCN)_6^{2+}$ Cluster-Supported Cobalt-Porphyrin Complexes

  • Park Su Mi;Won Jongok;Lee Myung-Jin;Kang Yong Soo;Kim Se-Hye;Kim Youngmee;Kim Sung-Jin
    • Macromolecular Research
    • /
    • 제12권6호
    • /
    • pp.598-603
    • /
    • 2004
  • Cellulose nitrate (CN) composite membranes, containing cobalt porphyrin (CoP) complexes self-assembled within nanometer-sized rhenium clusters (ReCoP), have been prepared and their oxygen and nitrogen gas perme­abilities were analyzed. The solubility of ReCoP and the characteristics of the corresponding composite membranes were analyzed using a Cahn microbalance, FT-IR spectroscopy, wide-angle X-ray scattering, and differential scanning calorimetry. The nitrogen permeability through the CN composite membranes decreased upon addition of ReCoP and CoP, which implies that the presence of these oxygen carrier complexes affects the structure of the polymer matrix. The oxygen permeability through the composite membranes containing small quantities of ReCoP decreased, but it increased upon increasing the concentration. The oxygen gas transport was affected by the matrix at low ReCoP concentrations, but higher concentrations of ReCoP increased the oxygen permeability as a result of its reversible and specific interactions with oxygen, effectively realizing ReCoP carrier-mediated oxygen transport.

상용 첨착활성탄의 일산화탄소 흡착성능 및 촉매산화반응 연구 (Investigation on CO Adsorption and Catalytic Oxidation of Commercial Impregnated Activated Carbons)

  • 고상원;김대한;김영독;박덕신;정우태;이덕희;이재영;권순박
    • 공업화학
    • /
    • 제24권5호
    • /
    • pp.513-517
    • /
    • 2013
  • 본 연구에서는 화재나 화생방전 시 비상대피에 사용되는 상용 방독면의 흡착소재인 첨착활성탄의 특성을 분석하고 일산화탄소(CO)의 흡착성능 및 산화반응을 조사하고자 하였다. 대표 제품 4개를 선정하여 BET/BJH 측정을 통해 각 활성탄소의 비표면적, 기공부피 및 기공크기를 비교분석하고 SEM/EDS와 XPS를 이용한 표면 성분분석을 수행하여 일산화탄소 제거 효율간의 관계를 연구하였다. 불순물 제거를 위한 전처리(heat-treatment) 후 망간(Mn)과 구리(Cu)가 주 금속으로 첨착되어 있는 화재용 시료에서는 업체에 관계없이 반응 초기에 일산화탄소의 흡착을 보였고 이후 활성 탄소 내에 첨착된 금속 촉매에 의해 최대 99%의 이산화탄소($CO_2$) 변환율로 높은 촉매활성을 보이며 산화반응이 진행되었다. 망간(Mn)을 함유하지 않은 화생방용 시료의 경우 이산화탄소로의 변환율은 최대 60%로서 화재용 시료에 비해 떨어짐을 관찰하였다. 화재용 시료의 전처리 유무에 따른 일산화탄소 반응성 조사에서는 전처리 후 기공 내 불순물 제거 효과로 상온에서 이산화탄소의 검출시간이 약 30 min간 지연되어 일산화탄소와 이산화탄소에 대해 모두 더 높은 제거율을 보임을 확인하였다.

서울 일부 지역 교통수단의 실내 공기질 평가 (Assesment of Indoor Air Quality within Public Transport Vehicles operating in specified locations throughout Seoul)

  • 손종렬;최달웅;최정숙;우완기
    • 환경위생공학
    • /
    • 제21권1호
    • /
    • pp.12-20
    • /
    • 2006
  • This paper was conducted concerning the degree of indoor air quality in public transport vehicles such as taxicabs, buses and subway trains, as sampled through the active participation of drivers and passengers in Seoul between 13th August 2005 and 2nd November 2005. The results were summarized as follows: 1. Among the measured substances especially respirable particulate matters ($PM_{10}$), total bacteria counts (TBC) and carbon dioxide ($CO_2$) exceeded the standard level of $150{\mu}g/m^3,\;800CFU/m^3$ and 1000ppm. 2. The concentration of carbon dioxide ($CO_2$) in taxi recorded 2491ppm, which is more than the standard amount of 1000ppm. This level was comparatively higher than all other public transportation methods. Total bacteria counts (TBC) in bus and subway recorded $1082CFU/m^3\;and\;1856CFU/m^3$, respectively. 3. The drivers who regularly work long hours showed the higher concern about contamination of the air inside the public transport vehicles and they considered it to be worse than the air outside. In contrast, the general public showed less concern about the air quality inside the public transport vehicles. However, they too acknowledged that the quality of the air inside the public transport vehicles was poor. In regards to the degree of indoor air quality in the public transport vehicles, a counterplan must be implemented urgently to effectively combat the excessive levels of $PM_{10}$, microorganism and $CO_2$. We need to gather more conclusive evidence pertaining to other possible contaminants and influencing factors.

Indoor air quality evaluation in intercity buses in real time traffic

  • Kazim O. Demirarslan;Serden, Basak
    • Advances in environmental research
    • /
    • 제11권1호
    • /
    • pp.17-30
    • /
    • 2022
  • Road transport allows all forms of land conditions to be met at less cost. Because of this function, despite numerous disadvantages, it becomes the most frequently used method of transport, especially in underdeveloped or developing countries. One of the most significant factors used in evaluating the atmosphere's air quality is the amount of CO2, increasing people's density in indoor spaces. The amount of CO2 indoors is, therefore, vital to determine. In this study, CO2 and temperature measurements made on nine different bus journey was made in Turkey. The minimum and maximum values were recorded as 555 ppm and 3000 ppm CO2, respectively, in the measurements. On all journeys, the average concentration is 1088.72 ppm. The minimum and maximum values were measured as 17.4℃ and 32.7℃ in the temperature measurements, and the average of all trips was calculated to be 25.76℃. In this study conducted before the Covid-19 pandemic, it was determined that the amount of CO2 increased with the density and insufficient ventilation in the buses. The risk of infection increases in places with high human density and low clean air. For situations such as pandemics, CO2 measurement is a rapid indicator of determining human density.