• Title/Summary/Keyword: $CO_2$ Removal

Search Result 1,175, Processing Time 0.03 seconds

Study on Adsorption of Carbon Dioxide in Cabin Using Chamber (챔버를 이용한 객실 이산화탄소 흡착 연구)

  • Cho, Young-Min;Lee, Ji-Yun;Choi, Jin-Shik;Kwon, Soon-Bark;Park, Duck-Shin;Kim, Hee-Man
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1309-1314
    • /
    • 2011
  • People spend approximately 80 ~ 90 % of their time in various kinds of indoor spaces. And, in metropolitan area, most people spend more than 1 hour in public transportation everyday. For this reason, people's interest in the indoor air quality is drastically increasing. Among various indoor air pollutants, $CO_2$ is one of the most severe environmental concerns. Ventilation is commonly used to keep low $CO_2$ concentration in the passenger cabin. However, ventilation may worse the indoor air quality problem in case of subway because the tunnel is seriously polluted by particulate matters. In this study, an alternative way to remove $CO_2$ was suggested. The adsorption of $CO_2$ by $CO_2$ adsorbent was studied. Zeolite modified with base was prepared, and $CO_2$ removal performance was tested in $4m^3$ and $24m^3$ environmental chambers. It was found that $CO_2$ adsorbent could effectively remove $CO_2$ in the chambers.

  • PDF

Lipid Production by a $CO_2$-Tolerant Green Microalga, Chlorella sp. MRA-1

  • Zheng, Yanlin;Yuan, Cheng;Liu, Junhan;Hu, Guangrong;Li, Fuli
    • Journal of Microbiology and Biotechnology
    • /
    • v.24 no.5
    • /
    • pp.683-689
    • /
    • 2014
  • Since $CO_2$ concentrations in industrial flue gases are usually 10%-20%, one of the prerequisites for efficient $CO_2$ removal by algae is the level of tolerance of microalgal species to exposure to high concentrations of $CO_2$. A newly isolated microalgal strain, Chlorella sp. MRA-1, could retain growth with high concentrations of $CO_2$ up to 15%. The highest lipid productivity for Chlorella sp. MRA-1 was 0.118 g/l/day with a 5% $CO_2$ concentration. Octadecenoic acid and hexadecanoic acid, the main components of biodiesel, accounted for 70% of the total fatty acids. A lipid content of 52% of dry cell weight was achieved with limited amounts of nitrogen. Chlorella sp. MRA-1 seems to be an ideal candidate for biodiesel production when cultured with high concentrations of $CO_2$.

Evaluation for adsorption of low concentration of indoor $CO_2$ adsorption using zeolite and alkali metal (제올라이트 및 알칼리금속을 이용한 실내용 저농도 $CO_2$ 흡착제의 성능 평가)

  • Lim, Yun-Hui;Lee, Ju-Yeol;Cha, Yu-Joung;Park, Byung-Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.494-503
    • /
    • 2013
  • In this study, $CO_2$ adsorbent was produced for minimizing energy loss due to ventilation within the building. For improved selectivity about low concentration of $CO_2$ in multiple-use facilities, the ball type adsorbent was modified from a commercial zeolite, alumina, alkali metals and activated carbon with mixing LiOH, binder, and $H_2O$. We measured specific surface area, pore characteristic, and crystal structure of the modified adsorbent. Effects of alkalization on the absorptive properties of the adsorbents were investigated. Continuous column tests (2,000 ppm) and batch chamber tests ($4m^3$, 5,000ppm) showed that the modified adsorbent indicated about the selectivity of $CO_2$ more than 9.7% (0.613 mmol/g) compared with ordinary adsorbents and $CO_2$ removal efficiency of 88.8% within l hour, respectively. It was estimated that the modified adsorbent was applicable to indoor environments.

Evaluation of Propylenecarbonate/water Physical Absorbents and its Application in Membrane Contactors for CO2/CH4 Separation (CO2/CH4 분리를 위한 프로필렌카보네이트/물 흡수제 특성 평가 및 막접촉기의 적용)

  • Park, Ahrumi;Kim, Seong-Joong;Lee, Pyung Soo;Nam, Seung Eun;Park, You In
    • Membrane Journal
    • /
    • v.26 no.2
    • /
    • pp.126-134
    • /
    • 2016
  • To produce renewable biomethane from biogas, the properties of physical absorbents such as water, methanol, 1-methyl-2-pyrrolidone (NMP), poly(ethylene glycol) dimethylether (PEGDME), and propylene carbonate (PC) were studied, and PC was applied to membrane contactor systems. Among physical absorbents, PC exhibited a high contact angle of $58.3^{\circ}$ on polypropylene surface, and a PC/water mixture (5 wt%) increased the contact angle to $90^{\circ}$. Furthermore, the PC/water mixture presented higher $CO_2$ absorption capacities (0.148-0.157 mmol/g) than that of water (0.121 mmol/g), demonstrating a good property as an absorbent for membrane contactors. Actual operations in membrane contactors using the PC/water mixture resulted in $CO_2$ removal of 98.0-97.8% with biomethane purities of 98.5-98.3%, presenting a strong potential for biogas treatment. However, the PC/water mixture yielded moderate improved in $CO_2$ removal and methane recovery, as compared with water in the membrane contactor operation. This is originated from insufficient desorption processes to reuse absorbent and low $CO_2$ flux of the PC/water absorbent. Thus, it is requiring optimizations of membrane contactor technology including development of absorbent and improvement of operation process.

Electrolyte Addition for Enhanced Wastewater Treatment by Electrolysis using Cu Electrode

  • Kim, Woo-Yeol;Yun, Chan-Young;Son, Dong-Jin;Chang, Duk;Kim, Dae-Gun;Hong, Ki-Ho
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.35-42
    • /
    • 2017
  • In this study, the effect of electrolyte addition on the removal of organics and nutrients in electrochemical wastewater using a copper electrode, and the characteristics of the by-product of electrolysis were investigated. The removal of organics increased significantly as shorter reaction times upon the addition of chloride ion, and most of the electrolysis reaction was completed within 20 min. The reaction rate gradually increased in proportion to the $Cl^-$/COD ratio, whereas the highest removed mass of organic matter per mass of added electrolyte was observed at a $Cl^-$/COD ratio of 1. After the addition of electrolyte, significant removal of ammoniacal nitrogen was observed as a result of the enhanced generation of oxidizers such as hypochlorite. Excellent phosphorus removal was also achieved in a very short reaction time (within 2 min) by electro-coagulation. As the electrolysis progressed, the amount of by-product increased gradually, whereas a decrease of sludge volume index was observed after the addition of electrolyte. This indicated that the settling performance of the by-products was better, and their removal would be easily achieved.

Application of nickel hexacyanoferrate and manganese dioxide-polyacrylonitrile (NM-PAN) for the removal of Co2+, Sr2+ and Cs+ from radioactive wastewater

  • Md Abdullah Al Masud;Won Sik Shin
    • Membrane and Water Treatment
    • /
    • v.15 no.2
    • /
    • pp.67-78
    • /
    • 2024
  • In this study, a nickel hexacyanoferrate and manganese dioxide-polyacrylonitrile (NM-PAN) composite was synthesized and used for the sorptive removal of Co2+, Sr2+, and Cs+ Cs+ in radioactive laundry wastewater. Single- and multi-solute competitive sorptions onto NM-PAN were investigated. The Freundlich (Fr), Langmuir (Lang), Kargi-Ozmıhci (K-O), Koble-Corrigan (K-C), and Langmuir-Freundlich (Lang-Fr) models satisfactorily predicted all the single sorption data. The sorption isotherms were nonlinearly favorable (Freundlich coefficient, NF = 0.385-0.426). Cs+ has the highest maximum sorption capacity (qmL = 0.855 mmol g-1) for NM-PAN compared to Co2+ and Sr2+, wherein the primary mechanism was the physical process (mainly ion-exchange). The competition between the metal ions in the binary and ternary systems reduced the respective sorption capacities. Binary and ternary sorption models, such as the ideal adsorbed solution theory (IAST) model coupled with single sorption models of IAST-Fr, IAST-K-O, IAST-K-C and IAST-Lang-Fr, were fitted to the experimental data; among these, the IAST-Freundlich model showed the most satisfactory prediction for the binary and ternary systems. The presence of cationic surfactants highly affected the sorption on NM-PAN due to the increase in distribution coefficients (Kd) of Co2+ and Cs+.

Effect of Media on the Biological Removal of Hydrogen Sulfide (생물학적 황화수소 제거에 미치는 담체의 영향에 관한 연구)

  • Jang, Hyun Sup;Lee, Tae Haeng;Kim, Chun Lee;Cho, Yong Beom;Oh, Min Hwan;Lee, Eun Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.2
    • /
    • pp.73-80
    • /
    • 2009
  • Biofilters use porous solid media to support microorganisms and allow access to the contaminants in the airflow. The characteristics of media used in biofilters vary greatly, and therefore it is important to select the appropriate media in order to obtain a large enough surface attachment area and uniform pore. This study was performed to compare hydrogen sulfide ($H_2S$) removal efficiencies of three biofilter media; coconut fiber, ceramic, and polyurethane. The biofilter packed with coconut fiber showed stable removal activity when inlet loading was changeable, and was restored rapidly when the moisture content decreased. However, the coconut fiber suffered from low durability. To cope with this problem a media of fibrinous polypropylene was developed to strengthen the durability of the coconut fiber. Biofilter column experiments using the fibrinous polypropylene media demonstrated over 99% of removal efficiencies at pH as low as 3 and 6 seconds of EBRT (empty bed gas residence time). Due to its superior physical characteristics, it is expected that the $H_2S$ treatment performance will increase when the new fibrinous polypropylne media is applied in commercial biofilter systems.

Swelling Indexes and Relevant Removal of Cd and Pb of the Na-bentonite activated with Na2CO3 and NaHCO3 (Na2CO3와 NaHCO3로 활성화한 Na-벤토나이트의 팽창특성과 Cd와 Pb의 상대적 등온흡착곡선)

  • Chung, Doug-Young;Yang, Jae E.;Oh, Taek-G.;Lee, Kyo-S.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.40 no.1
    • /
    • pp.64-70
    • /
    • 2007
  • In this experiment we transformed the Ca-bentonite into Na-bentonite with two inorganic Na-chemicals under different temperatures. These two Na-chemicals were selected among five different Na-chemicals which carries Na as cation. The swelling capacity of the Na chemical-treated bentonite was increased with increasing Na concentration, while the maximum concentration of Na solution decreased with increasing temperature. $Na_2CO_3$ was most effective in exchanging Ca ions and resulting in the highest swelling index among the Na-chemicals. The swelling index was significantly increased with increasing temperature to $100^{\circ}C$. But the equilibration time reversely affected the swelling index due to a rapid increase in evaporation of water. Within same amount of Na treatment SI slightly decreased not only with increasing contacting time but also with increasing temperature. The adsorption for the transformed Na-bentonite was increased with increasing equilibrium concentrations of Pb and Cd ions for all the activated Na-B and indigenous Ca-B and Na-B while the adsorbability of $Pb^{2+}$ onto each Na-B sample is more than that of $Cd^{2+}$. And the maximum adsorption capacity sequence of Na-B samples for Pb and Cd has been found to be 5 % $Na_2CO_3.$ - 5 % $NaHCO_3$ > 3 % $NaHCO_3$ > 3 % $Na_2CO_3$ > 1 % $NaHCO_3$ > 1 % $Na_2CO_3$ > indigenous Na-B > indigenous Ca-B, showing that there are contradictory results about the relationship of cation adsorption to CEC.

Slaughterhouse wastewater treatment in a bamboo ring anaerobic fixed-bed reactor

  • Tritt, Wolfgang P.;Kang, Ho
    • Environmental Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.70-75
    • /
    • 2018
  • A pilot scale anaerobic fixed-bed with a reactor volume of $2.8m^3$ was built to treat slaughterhouse wastewater. Bamboo rings were chosen as support media mainly because of their cheaper price in underdeveloped countries. Even with their lower porosity and specific surface, the reactor performance showed a maximum 95% COD removal efficiency at an organic loading rate (OLR) of $1kg\;COD/m^3-d$ with its corresponding hydraulic retention time (HRT) of 7.5 d. At a higher OLR of $4.0kg\;COD/m^3-d$, the COD removal efficiency of 75% was achieved with an HRT of 2 d. No big difference in COD removal efficiencies was found between the reactors operated in both upflow and downflow modes. Their operational behavior and effluent characteristics were similar. The effluent COD/TKN ratio of 6.67 at an OLR of $4.0kg\;COD/m^3-d$ was only marginal acceptable range for a subsequent biological denitrification process. Otherwise carbon supplementation is required at a lower OLR.

A Study on the Extraction and Purification of Glutathione from Yeast

  • Kim, Seong-Ung;Yang, Choong-Ik;Min, Shin-Hong;Rhee, Sang-Hi;Kim, Yong-Bae
    • Journal of Pharmaceutical Investigation
    • /
    • v.8 no.2
    • /
    • pp.1-10
    • /
    • 1978
  • During the course of studies on the production of glutathione from yeast, process development and optimization was carried out. The optimal pH for the extraction of glutathione was found to be 2.5 to 4.0 and the maximum yield for glutathione was obtained when the extraction temperature was 25 to $45^{\circ}C$. The cuprous salt of glutathione was recovered maximally at the range of 2 to 4g of cuprous oxide per 10 Kg of compressed yeast. Further purification was needed for the removal of impurities from glutathione. Cation exchange resin, anion exchange resin and Sephadex G-25 were employed for this purpose. 13 to 15 g of glutathione was obtained from 10 Kg of compressed yeast and the purity was above 99.3%.

  • PDF