• Title/Summary/Keyword: $CO_2$레이저

Search Result 591, Processing Time 0.088 seconds

Linearly Polarized 1-kW 20/400-㎛ Yb-doped Fiber Laser with 10-GHz Linewidth (선편광된 10 GHz 선폭의 1 kW급 20/400-㎛ 이터븀 첨가 광섬유 레이저)

  • Jung, Yeji;Jung, Minwan;Lee, Kangin;Kim, Taewoo;Kim, Jae-Ihn;Lee, Yongsoo;Cho, Joonyong
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.3
    • /
    • pp.120-125
    • /
    • 2021
  • We have developed a linearly polarized high-power Yb-doped fiber laser in the master oscillator power amplifier (MOPA) scheme for efficient spectral beam combining. We modulated the phase of the seed laser by pseudo-random binary sequence (PRBS), with the bit length optimized to suppress stimulated Brillouin scattering (SBS), and subsequently amplified seed power in a 3-stage amplifier system. We have constructed by coiling the polarization-maintaining (PM) Yb-doped fiber, with core and cladding diameters of 20 ㎛ and 400 ㎛ respectively, to a diameter of 9-12 cm for suppression of the mode instability (MI). Finally, we obtained an output power of 1.004 kW with a slope efficiency of 83.7% in the main amplification stage. The beam quality factor M2 and the polarization extinction ratio (PER) were measured to be 1.12 and 21.5 dB respectively. Furthermore, the peak-intensity difference between the Rayleigh signal and SBS signal was observed to be 2.36 dB in the backward spectra, indicating that SBS is successfully suppressed. In addition, it can be expected that the MI does not occur because not only there is no decrease in slope efficiency, but also the beam quality for each amplified output is maintained.

Multi-wavelength Dental Laser Development by Design Optimization of Optics, Cooling and Power systems (광학계, 냉각계, 전력계의 최적화에 의한 다파장 치과용 레이저 개발)

  • 윤길원;김홍식;전병문;이성근;이왕진
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.130-131
    • /
    • 2003
  • 수술용으로 쓰이는 치과용 레이저로는 Nd:YAG, $CO_2$, Er:YAG 레이저들이 있다. 치료 부위에 따라 두 가지 응용으로 나눌 수 있다. 잇몸의 절개 등은 주로 $CO_2$나 Nd:YAG 레이저를 이용하여 정밀하게 그리고 출혈을 최소로 하는 레이저의 장점을 살리면서 시술하고 있다. $CO_2$레이저의 경우 강한 열적 손상작용 때문에 출력 조사 시간을 짧게 하여 사용하며, 열적 손상력이 낮은 Nd:YAG 레이저는 화이버를 접촉식으로 하여 화이버의 작은 면적의 높은 광밀도를 이용하여 시술하고 있다. (중략)

  • PDF

Laser doppler velocimeter using the self-mixing effect of a $CO_2$ laser (산란광의 되먹임을 이용한 $CO_2$ 레이저 도플러 속도 측정)

  • 최종운;김용평;김윤명
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.157-161
    • /
    • 1996
  • A simple laser Doppler velocimeter(LDV) using a $CO_2$ laser with its self-mixing effect has been developed. We measured the laser power which was modulated by Doppler frequency, when monochromatic laser light was focused to a moving target. The Doppler-shifted frequency was controlled by changing rotating speed of the turntable or the cosine of the angle between the direction of the laser beam and that of the rotating velocity.

  • PDF

Design and evalution of pulsed $CO_2$ laser system using high repetition ratio and high precision (고반복율 및 고정밀방식을 이용한 펄스형 $CO_2$ Laser 시스템 설계 및 평가)

  • 김흥수;김휘영
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.8
    • /
    • pp.1055-1062
    • /
    • 2001
  • Study, it is the purpose to develope a cheap and compact pulsed $CO_2$ laser with pulse repetition rate range of 1 KHz. We used a IGBT switched power supply as a power supply, which is cheap and simple comparing to others. PIC one-chip microprocessor was used for precise control of a laser power supply on the control part. And the laser cavity was fabricated as an axial and water cooled type. The laser performance characteristics as various parameters, such as pulse repetition rate, gas pressure, and gas mixture rate have been investigated. The experiment was done under the condition of total pressure of $CO_2$$N_2$:He = 1:3:10, 1:1.5:5, 1:9:15 from 6 Torr to 15 Torr and pulse repetition rate from 100 Hz to 900 Hz. As a result, the maximum average outpu was about 20.5 W at the total pressure of 15 Torr, the gas mixture $CO_2$$N_2$:He = 1:9:15 and the pulse repetition rate of 700 Hz.

  • PDF

A Study on the pulsed $CO_2$ laser by the switching control of leakage transformer primary (누설변압기 1차측의 스위칭 제어에 의한 펄스형$ CO_2$ 레이저에 관한 연구)

  • 정현주;이동훈;김도완;이유수;김중만;김희제
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.100-101
    • /
    • 2000
  • 최근에 100Hz 이하의 펄스 반복율을 가지는 20 W급 출력의 의료용 및 마킹용 펄스 $CO_2$레이저의 수요가 증가함에 따라 유지와 보수의 편리성은 물론 사용자의 편의성을 충족시키기 위한 레이저 전원장치의 소형화, 출력 제어의 용이성 및 저가격화 등에 대한 요구가 증대되고 있다. 기존의 펄스형 $CO_2$레이저의 전원장치는 원하는 펄스 반복율에 맞도록 스위칭 소자를 "on"-"off"하여 콘덴서에 충전된 에너지를 고압 펄스 트랜스를 통해서 레이저 방전관에 인가하는 방식이다. 즉 DC를 스위칭 과정을 통해 펄스 에너지로 변환시킨 후 방전관에 그 펄스에너지를 공급하는 형태이다$^{(1)}$ . (중략)

  • PDF

Optical fiber polishing technique using a CO2 laser (CO2 레이저를 이용한 초정밀 광섬유 연마 레이저 기술)

  • Choi, Hun-Kook;Sohn, Ik-Bu;Noh, Young-Chul;Jung, Deok;Lee, Man-Seop;Lee, Seo-Young;Lee, Hyung-Jong
    • Laser Solutions
    • /
    • v.16 no.2
    • /
    • pp.12-15
    • /
    • 2013
  • In this paper, we controlled the edge angle of fiber by using $CO_2$ laser. In order to control the angle, tilting angle of fiber on stage and the number of scan repetition are adjusted, and laser power is fixed at 30 W in the experiment. In the polishing result, the edge angle of fiber can be changed from $4^{\circ}$ to $8^{\circ}$, as changing the tilting angle and the number of scan repetition. This $CO_2$ laser polishing can fabricate ball lenses with various curvatures and a sharp probe as well as the edge angled fiber.

  • PDF