• Title/Summary/Keyword: $CO_2$농도

Search Result 3,987, Processing Time 0.035 seconds

Analysis of Spatial and Vertical Variability of Environmental Parameters in a Greenhouse and Comparison of Carbon Dioxide Concentration in Two Different Types of Greenhouses (온실 환경요인의 공간적 및 수직적 특성 분석과 온실 종류에 따른 이산화탄소 농도 비교)

  • Jeong, Young Ae;Jang, Dong Cheol;Kwon, Jin Kyung;Kim, Dae Hyun;Choi, Eun Young
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.221-229
    • /
    • 2022
  • This study was aimed to investigate spatial and vertical characteristics of greenhouse environments according to the location of the environmental sensors, and to investigate the correlations between temperature, light intensity, and carbon dioxide (CO2) concentration according to the type of greenhouse. Temperature, relative humidity (RH), CO2, and light sensors were installed in the four-different vertical positions of the whole canopy as well as ground and roof space at the five spatial locations of the Venlo greenhouse. Also, correlations between temperature, light intensity, and CO2 concentration in Venlo and semi-closed greenhouses were analyzed using the Curve Expert Professional program. The deviations among the spatial locations were larger in the CO2 concentration than other environmental factors in the Venlo greenhouse. The average CO2 concentration ranged from 465 to 761 µmol·mol-1 with the highest value (646 µmol·mol-1) at the Middle End (4ME) close to the main pipe (50Ø) of the liquefied CO2 gas supply and lowest (436 µmol·mol-1) at the Left Middle (5LM). The deviation among the vertical positions was greater in temperature and relative humidity than other environments. The time zone with the largest deviation in average temperature was 2 p.m. with the highest temperature (26.51℃) at the Upper Air (UA) and the lowest temperature (25.62℃) at the Lower Canopy (LC). The time zone with the largest deviation in average RH was 1 p.m. with the highest RH (76.90%) at the LC and the lowest RH (71.74%) at the UA. The highest average CO2 concentration at each hour was Roof Air (RF) and Ground (GD). The coefficient of correlations between temperature, light intensity, and CO2 concentration were 0.07 for semi-closed greenhouse and 0.66 for Venlo greenhouse. All the results indicate that while the CO2 concentration in the greenhouse needs to be analyzed in the spatial locations, temperature and humidity needs to be analyzed in the vertical positions of canopy. The target CO2 fertilization concentration for the semi-closed greenhouse with low ventilation rate should be different from that of general greenhouses.

A Study on the Direct Discharge Test for Verifying Design Concentration and Soaking Time for CO2 Fire Extinguishing System of Total Flooding (전역방출방식 CO2 소화설비의 설계농도 및 유지시간 검증을 위한 직접방사실험에 관한 연구)

  • Lee, Se-Myeoung;Moon, Sung-Woong;Ryu, Sang-Hoon
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.15-23
    • /
    • 2012
  • Indirect Test Method is often used instead of direct test method in test method for extinguishing performance of $CO_2$ extinguishing facility because of high cost, environment problems and difficulties of procedure. But in the danger facilities for a unit of nation, such as a petrochemical plant, a nuclear power plant, or etc. is better to verify the performance of the extinguishment through direct discharge test. In $CO_2$ extinguishing system for total flooding system installed in dangerous facilities in Korea, each protected area in surface fire and deep-seated fire had selected and verified of extinguishing performance of $CO_2$ extinguishing facilities. To get recognized as extinguishing performance, discharged $CO_2$ concentration to protected area should be equivalence with design concentration standards (NFSC and NFPA). The Design Concentration means that $CO_2$ extinguishing agent is considerate of concentration for percentage of allowance (20 %) from extinguishing concentration which available to control of flame. As test result, surface fire and deep seated fire in protected area is obtained $CO_2$ design concentration and maintained design concentration more than 20 minutes as deep-seated fire. Through this study, we introduced direct discharging test method and decision method. And furthermore, especially in the dangerous facilities as a unit of Nation, we suggested necessity about reliability of extinguishing facilities to use direct test method.

Effect of $CO_2$ Concentration in CA Conditions on the Quality of Shiitake Mushroom (Lentinus edodes) during Storage (표고버섯(Lentinus edodes)의 CA 저장 중 탄산가스농도의 효과)

  • Kim, Dong-Man;Baek, Hyung-Hee;Yoon, Hye-Hyun;Kim, Kil-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.461-467
    • /
    • 1989
  • The effect of $CO_2$ concentration on the post-harvest physiology and quality of Shiitake mushroom (Lentinus edodes) were investigated during CA storage. The respiratory rates of the mushroom stored in CA conditions were abruptly increased in proportion to $CO_2$ concentration after 40 days, and then declined, while that of the mushroom in air was continuously decreased throughout storage period. Large amounts of ethanol and acetaldehyde were produced from the 20 days CA stored mushrooms. The least changes in 5'-GMP content and electrophoresis pattern of protein in the mushroom were observed at $CO_2$ concentration of 2% during storage. Based on the changes in quality factors of the mushroom during storage, it could be concluded that $CO_2$ concentration of 2% with fixed $O_2$ concentration of 2% was more effective in extension of the freshness than any other $CO_2$ level in this experiment.

  • PDF

Effect of carbon dioxide of root zone on emergence and early growth of transplanted ginseng (근권(根圈)의 CO2 농도(濃度)가 묘삼(苗蔘)의 출아(出芽) 및 초기생육(初期生育)에 미치는 영향(影響))

  • Park, Hoon;Lee, Myong-Gu
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.22 no.2
    • /
    • pp.127-130
    • /
    • 1989
  • Ginseng seedlings were transplanted in the perlite and grown with various $CO_2$ concentration for 14 days. The days for full emergence was decreased by 3 days at 6 to 8% $CO_2$ but increased above 13%. Stem length showed significant negative linear correlation with $CO_2$ concentration at 14 days but little difference at 64 days. Relative growth (%) to seedling at 64 days tended to increased till 8% $CO_2$ and decrease thereafter without significance. Seedlings showed 65% emergence with short stem (60%) under 22% $CO_2$ for 64 days. Seedlings were all sleeping under 35% $CO_2$ for 64 days. Above results indicates that $CO_2$ may be useful for growth control or post harvest storage of ginseng.

  • PDF

Response of Rice Growth under $CO_2$ Enrichment ($CO_2$ 농도 증가에 따른 벼의 생육 반응)

  • Kim Young-Guk;Shin Jin-Chul;Choi Min-Gyu;Koo Bon-Cheul;Kim Seok-Dong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.3
    • /
    • pp.179-185
    • /
    • 2005
  • The effects of $CO_2$ enrichment on growth of rice (Oryza sativa L.) were examined. The plants were grown in growth chambers with a 12-h photoperiod and a day/night temperature of $28/21^{\circ}C$ of the seedling stage and $30/23^{\circ}C$ after the panicle initiation stage. The plants were exposed to two elevated $CO_2$ of 500, 700 ppm and ambient levels (350 ppm). At early growth stage of three varieties (IIpumbyeo, Chucheongbyeo, Hwaseongbyeo), the elevated $CO_2$ increased plant height, tiller, leaf area and dry weight. The photosynthetic rate was decreased at 24 days after treatment (DAT) compared to 11 DAT. The elevated $CO_2$ increased plant height and dry weight at panicle initiation stage (PIS) and heading stage (HS) of three varieties (IIpumbyeo, Chucheongbyeo, Hwaseongbyeo). The photosynthetic rate, stomatal conductance, evapotranspiration rate were decreased at the long days of treatment than that of short days. At entire stages, the elevated $CO_2$ increased the water use efficiency of rice plant because evapotranspiration rate was lowered at the elevated $CO_2$ than ambient levels.

Measuring CO Concentration in a Flame with Broadband CARS (광대역 CARS를 이용한 불꽃 내부의 CO 농도 측정)

  • 한재원
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.2
    • /
    • pp.212-219
    • /
    • 1993
  • To reduce the mode noise induced from a multimode dye laser, a modeless laser generating amplified spontaneous emission was used as Stokes beam of the broadband CARS. A new technique for measuring species concentration from the modulation dip of nonresonant background of broadband CARS spectrum was proposed. The modulation dip was numerically calculated and fitted as a function of the concentration of the minor species and temperature of gas sample. We applied this technique in measuring CO concentration in a static cell and also the profile of CO concentration in a CHdair premixed flame of a counterflow burner.

  • PDF

A Study on Extinguishing Concentration of K2CO3-Zeolite Composites (K2CO3가 흡착된 합성제올라이트 구조체의 소화농도에 관한 연구)

  • Kim, Seung-Il;Shin, Chang-Sub
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.42-47
    • /
    • 2012
  • In the study, fire extinguishing concentration of $K_2CO_3$-Zeolite composite was measured. Zeolite composite is a porous adsorbent which has small particle size, low density and anti-catalytic effect. Scanning Electron Microscopy, X-Ray diffraction and thermal analysis were also conducted to investigate the structural properties of composite. The result showed that despite of weight ratio, the extinguishing concentration of the composite was lower than pure $K_2CO_3$. The extinguishing concentration of $K_2CO_3$-Zeolite composite which has weight ratio of 7 : 3 was 5.72 times lower than that of pure $K_2CO_3$ and 1.1 times lower than that of ABC powder. The SEM and XRD patterns showed that $K_2CO_3$ was adsorbed on the Zeolite properly, and through the thermal analysis, it was founded that the composite is more effective extinguishing agent than pure $K_2CO_3$.

A Study on the PM10 and CO2 Concentrations at Public Places (일부 실내공간에서 PM10과 CO2의 농도 특성에 관한 연구)

  • Jung, Joon-sig;Park, Duckshin;Kim, Jong bum;Song, Hyea-suk;Park, Hyung-kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4335-4347
    • /
    • 2015
  • The objective of this study was to investigate $PM_{10}$ and $CO_2$ concentrations in the classrooms of 286 elementary schools in Suwon, Ansan, and Hwaseong in the province of Gyeonggi between August 2008 and December 2012. By gaining an understanding of the environmental factors that influence these concentrations, this study also aimed to establish a management plan for indoor air quality in schools, which substantially affects the health of elementary students. When the schools were classified by region, no statistically significant difference in $PM_{10}$ concentration was observed. However, $PM_{10}$ concentration was relatively high in industrial areas and low in rural areas. No difference in $CO_2$ concentration was observed among the surveyed cities. Analysis of annual $PM_{10}$ concentration showed that the highest values for Suwon and Hwaseong occurred in 2008 and 2009, respectively (p<0.01). In the case of Ansan, the highest concentration occurred during 2009, but the difference was not significant compared to the other years. Analysis of the annual $CO_2$ concentration of each city shows no significant difference among the cities (p-value=0.366,0.730,0.210). According to a time series analysis of $PM_{10}$ and $CO_2$ by season, from autumn 2008 to winter 2012, $PM_{10}$ concentration was high during 2009, then it gradually decreased until 2012, and started to increase again. While no difference in annual $CO_2$ concentration was observed, the concentration had a tendency to be higher in spring and winter than in summer. By analyzing the relationship between $PM_{10}$ and $CO_2$ and the environmental factors (years of construction, average students of classroom, temperature, and humidity), it showed a significant negative correlation was found between $CO_2$ and the environmental temperature and humidity, at -0.329 and -0.188, respectively (p<0.01).

Effects of Elevated CO2 Concentration on Leaf Phenology of Quercus acutissima (이산화탄소 농도 증가가 상수리나무 잎의 계절현상에 미치는 영향)

  • Seo, Dong-Jin;Oh, Chang-Young;Han, Sim-Hee;Lee, Jae-Cheon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.16 no.3
    • /
    • pp.213-218
    • /
    • 2014
  • Effects of elevated $CO_2$ on leaf phenology of Quercus acutissima were examined using open-top chambers, which had ambient and elevated $CO_2$ concentrations (ambient ${\times}1.4$, ambient ${\times}1.8$). To analyze the effect of chamber, non-treatment block was established near outside of the chambers. In 2013, budburst, leaf unfolding, coloring, and shedding were surveyed, and spring phenology was surveyed in 2014. Thermal sum (base temperature $+5^{\circ}C$) of each phenological event occurred was recorded. In addition, bud samples were collected and analyzed for carbohydrate contents in March 2014. Elevated $CO_2$ concentration advanced budburst and leaf unfolding, and delayed shedding in 2013. However, in 2014, the temperature of the spring season was high, and there was no significant effect of elevated $CO_2$ concentration on spring phenology. Carbohydrates content, such as starch, total non-structural carbohydrate and total soluble sugar, were significantly increased in response to elevated $CO_2$ concentration. It has been proposed that elevated $CO_2$ concentration could extend the growing season of temperate species with increased possibility of frost damage due to early bud opening and leaf unfolding. However, our analysis showed that the increased carbohydrate concentration in bud under elevated $CO_2$ would reduce the possibility of early spring frost damage by acting as cryoprotectant.

Comparative Study of Char Burn-Out and NOx Emissions in O2/N2 and O2/CO2 environments (순산소 분위기에서 촤 연소 및 질소산화물 배기특성 비교)

  • Lee, Chun-Sung;Kim, Seong-Gon;Lee, Byoung-Hwa;Chang, Young-June;Jeon, Chung-Hwan;Song, Ju-Hun
    • Journal of Energy Engineering
    • /
    • v.20 no.3
    • /
    • pp.191-199
    • /
    • 2011
  • The char burn-out and NOx emissions from sub-bituminous coal were investigated in drop tube furnace under $O_2/N_2$ and $O_2/CO_2$ environments with different $O_2$ concentrations of 12, 21 and 31%. Results show that the char burn-out rate is faster as $O_2$ concentration increases higher and char burn-out rate under $O_2/CO_2$ decreases due to the lower oxygen diffusion into coal surface through the $CO_2$ rich boundary layer. NO concentration increases with increasing $O_2$ concentration, but declines at $O_2$ concentration of 31%. Meanwhile, NO emission indexes decreases monotonically with increasing $O_2$ concentration, which indicates that more NO reduction occurs with higher $O_2$ concentration probably due to greater HCN formation. For all conditions of $O_2$ concentration, the NO concentration under $O_2/N_2$ maintains higher than those of $O_2/CO_2$ due to presence of thermal NO.