• Title/Summary/Keyword: $CO_2$농도

Search Result 3,995, Processing Time 0.034 seconds

Ecophysiology of Photosynthesis 3: Photosynthetic responses to elevated atmospheric $CO_2$ concentration and temperature (광합성의 생리생태 (3) - $CO_2$ 농도와 온도 상승에 대한 광합성 반응 -)

  • 김판기;이은주
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.3 no.4
    • /
    • pp.238-243
    • /
    • 2001
  • 대기중의 $CO_2$ 농도 상승은 지구온난화의 주원인이 되고 있는데, 1960년대 전반에 320$\mu$㏖ㆍ㏖$^{-1}$ 이하 였던 $CO_2$농도가 화석연료의 사용량 증가, 삼림 벌채 등의 영향으로 근년에는 360 $\mu$㏖ㆍ㏖$^{-1}$ 이상으로 상승하였다(Bagastow et al., 1985). 이러한 추세로 대기중의 $CO_2$ 농도가 증가한다면 21세기 말에는 $CO_2$ 농도가 현재의 약 2배로 상승되고, 2~6$^{\circ}C$의 기온 상승이 예측되어 (Burroughs, 2001) 지구차원의 환경문제로 대두되고 있다.(중략)

  • PDF

Preliminary Report of Observed Urban - Rural Gradient of Carbon Dioxide Concentration across Seoul, Suwon, and Icheon in South Korea (도시 - 전원간 이산화탄소(CO2) 농도구배 예비관측 결과)

  • Chung, U-Ran;Lee, Kyu-Jong;Lee, Byun-Woo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.4
    • /
    • pp.268-276
    • /
    • 2007
  • Urban atmosphere may play as a harbinger for the future climate change with respect to temperature and $CO_2$ concentration. The Seoul metropolitan area is unique in rapid urbanization and industrialization during the last several decades, providing a natural $CO_2$ dome with increased temperature. This study was carried out to evaluate the feasibility of using the urban-rural environmental gradient in replacement of the IPCC mid-term scenario (after 30-50 years). For this, we measured atmospheric $CO_2$ concentration and air temperature at three sites with different degree of urbanization (Seoul, Suwon, and Icheon). Results from 11-month measurement can be summarized as follows: (1) The annual mean $CO_2$ concentration across 3 sites was in the order of Seoul (439 ppm) > Suwon (419 ppm) > Icheon (416 ppm), showing a substantial urban-rural environmental gradient. (2) The diurnal fluctuation in $CO_2$ concentration was greater in summer than in winter, showing the effect of photosynthesis on local $CO_2$ concentration. (3) The daily maximum $CO_2$ concentration was observed at 0500 LST in spring and summer, 0800 LST in autumn, and 0900 LST in winter, showing the sunrise-time dependence. (4) The observed hourly maximum $CO_2$ concentration averaged for the whole period was 446 ppm in Seoul at 0700 LST, while the minimum was 407 ppm in Suwon at 1500 LST. (5) Compared with the background atmospheric concentration of $CO_2$ in Anmyeon-do (377.4 ppm annual mean), $CO_2$ concentration of the study sites was higher by 14% in Seoul, by 10% in Suwon, and by 9% in Icheon. The observed $CO_2$ concentration in Seoul reached already 98% of the 2030-2040 projection (450 ppm) and 80% of the 2040-2050 projection (550 ppm) under the IPCC BAU scenario, showing a feasibility of using the $CO_2$ dome of Seoul as a natural experimental setting for the mid-term climate change impact assessment.

Low Concentration CO2 Absorption Performance of Aqueous Alkanolamine Solutions (알카놀아민 수용액을 이용한 저농도 CO2 흡수 특성)

  • Park, IL-Gun;Hong, Min-Sun;Kim, Beom-Seok;Kim, Heung-Lea
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.3
    • /
    • pp.185-191
    • /
    • 2014
  • In this paper, absorption and reaction characteristics of low $CO_2$ and alkanolamines were investigated. As MEA concentrations increase 1, 2 and 3 wt%, $CO_2$ loadings decrease 0.34 mol-$CO_2/mol$-absorbent, 0.32 mol-$CO_2/mol$-absorbent and 0.3 mol-$CO_2/mol$-absorbent, respectively. Also, $CO_2$ loadings decrease from 0.32 mol-$CO_2/mol$-absorbent, 0.30 mol-$CO_2/mol$-absorbent and 0.28 mol-$CO_2/mol$-absorbent as AMP concentrations increase 1, 2 and 3 wt%. Experimental results with blending solutions show that $CO_2$ loading was the highest, 0.52 mol-$CO_2/mol$-absorbent, when 0.5 wt% MEA and 0.5 wt% AMP were blended.

The Study on Structural Change and Improvement of Electrochemical Properties by Co-precipitation Condition of Li[Ni0.8Co0.15Al0.05]O2 Electrode (Li[Ni0.8Co0.15Al0.05]O2 전극의 공침 조건을 통한 구조적 변화와 전기적 특성의 향상 고찰)

  • Im, Jung-Bin;Son, Jong-Tae
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.2
    • /
    • pp.98-103
    • /
    • 2011
  • [ $Li[Ni_{0.8}Co_{0.15}Al_{0.05}]O_2$ ]cathode material for lithium secondary battery is obtained using co-precipitation method. To determine the optimal metal solution concentration value, the CSTR coprecipitation was carried out at various concentration values(1-2 mol/L). The surface morphology of coated samples was characterization by SEM(scanning electron microscope) and XRD (X-Ray Diffraction)analyses. Impedance analysis and cyclic voltammogram presented that internal resistance of the cell was dependent upon the concentration of metal solution. such data is very helpful in determining the optimal content of metal solution concentration to enhancing electrochemical property by adjusting powder size distribution and crystal structure.

Analysis of the Characteristics and High Concentrations of Carbon Dioxide Measured at the Gosan Site in Jeju, Korea in 2007 (2007년 제주 고산의 이산화탄소 농도 현황 및 고농도 사례 분석)

  • Kim, Seung-Yeon;Lee, Jae-Bum;Yu, Jeong-Ah;Hong, Yu-Deog;Song, Chang-Geun
    • Journal of Climate Change Research
    • /
    • v.2 no.1
    • /
    • pp.1-14
    • /
    • 2011
  • In order to identify the current state of the $CO_2$ concentrations at the Gosan site in Jeju, the data from the Gosan station was compared with the ones from domestic and foreign sites registered in the World Data Centre for Greenhouse Gases(WDCGG). As a result, the $CO_2$ concentrations in the Asian region including Gosan site were higher than in the other continents, which can be explained that the $CO_2$ emissions in the Asian region have been rapidly increasing due to the recent economic growth. In comparison with ther Asian-Pacific sites (i.e., Ryori, Waliguan, and Mauna Loa), Gosan site showed the highest $CO_2$ concentrations because this site can be easily affected by China emissions. With the trajectory analysis and the ratios of air pollutants, we found that the high concentrations of Gosan site in January were mainly caused by the long-range transport from China, while in August the high concentration in the night time by the stagnation and the active plant respiration. Also, in May and November it occurred as the polluted air from China was transported with migratory cyclone.

Study on the Desulfurization Characteristic of Limestone Depending on the Operating Parameters of In-Furnace Desulfurization for Oxy-Fuel Combustion Using Drop Tube Furnace (순산소연소 조건에서 Drop tube furnace를 이용한 운전변수에 따른 석회석의 탈황특성 연구)

  • Choi, Wook;Jo, Hang-Dae;Choi, Won-Kil;Park, Yeong-Sung;Keel, Sang-In;Lee, Hyung-Keun
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.857-864
    • /
    • 2011
  • Oxy-fuel combustion with many advantages such as high combustion efficiency, low flue gas flow rate and low NOx emission has emerged as a promising CCS technology for coal combustion facilities. In this study, the effects of the direct sulfation reaction on $SO_2$ removal efficiency were evaluated in a drop tube furnace under typical oxy-fuel combustion conditions represented by high concentrations of $CO_2$ and $SO_2$ formed by gas recirculation to control furnace combustion temperature. The effects of the operating parameters including the reaction temperature, $CO_2$ concentration, $SO_2$ concentration, Ca/S ratio and humidity on $SO_2$ removal efficiency were investigated experimentally. $SO_2$ removal efficiency increased with reaction temperature up to 1,200 due to promoted calcination of limestone reagent particles. And $SO_2$ removal efficiency increased with $SO_2$ concentrations and the humidity of the bulk gas. The increase of $SO_2$ removal efficiency with $CO_2$ concentrations showed that $SO_2$ removal by limestone was mainly done by the direct sulfation reaction under oxy-fuel combustion conditions. From the impact assessment of operation parameters, it was shown that these parameters have an effects on the desulfurization reaction by the order of the Ca/S ratio > residence time > $O_2$ concentration > reaction temperature > $SO_2$ concentration > $CO_2$ concentration > water vapor. The semi-empirical model equation for to evaluate the effect of the operating parameters on the performance of in-furnace desulfurization for oxy-fuel combustion was established.

A Study of the Characteristics of Flow and the Distribution of $CO_2$ Agent Concentration According to the Number of $CO_2$ Agent Nozzle ($CO_2$소화제 노즐수에 따른 유동특성 및 소화제농도분포에 대한 연구)

  • Park Chan-Su
    • Fire Science and Engineering
    • /
    • v.19 no.2 s.58
    • /
    • pp.37-44
    • /
    • 2005
  • We have conducted a numerical simulation under three-dimensional unsteady conditions in order to analyze the characteristics of flow and the distribution of $CO_2$ agent concentration according to the number of $CO_2$ agent nozzle. The engine room of a ship was selected as a protection space, and flow fields and $CO_2$ concentration fields were measured. In case of increasing the number of $CO_2$ nozzle from 2 nozzles to 4 nozzles, the distribution of CO2 concentration showed low, and in case of increasing the number of $CO_2$ nozzle to above 6 nozzles, the recirculating flow affected to all region was generated. In case of increasing the number of $CO_2$ agent nozzle to above 4 nozzles, the iso-concentration line below 0.36 expanded or contracted slightly. Therefor, the proper number and the arrangement of $CO_2$ agent nozzle are considered when $CO_2$ fire fighting system is designed.

Soil Air CO2 Concentrations in a Spruce-Fir Forest, Maine, USA

  • Son, Yow Han;Fernandez, Ivan J.;Kim, Zin-Suh
    • Journal of Korean Society of Forest Science
    • /
    • v.81 no.2
    • /
    • pp.177-182
    • /
    • 1992
  • Soil air $CO_2$ concentrations were measured in two soil depths (O and B horizon) by (1) the use of the Draeger direct reading chromatographic tubes and (2) syringe gas collections with gas chromatographic detection in a Spodosol supporting low elevation, commercial spruce-fir forest, Maine, USA, Mean soil air $CO_2$ concentrations(%) during the growing season of 1991 ranged from 0.11 in the O horizon by the Draeger method to 0.29 in the B horizon by the gas chromatographic method. Soil air $CO_2$ concentrations by the Draeger method were lower than those obtained using the gas chromatographic method for both soil horizons. However, data from the two methods were significantly(p<0.01) correlated and paralleled each other relative to temporal patterns. Positive and highly significant correlations existed between soil air $CO_2$ concentrations and soil temperature, although correlation coefficients only ranged from 0.13 to 0.32, depending on the method and horizon chosen.

  • PDF

The Characteristics of $CO_2 $ Extinguishant Transfer According to the Nozzle Conditions of a Fixed Eire System (고정식 소화장치 노즐조건에 따른 $CO_2 $전달특성)

  • 박찬수;최주석;전철균
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.41-48
    • /
    • 2004
  • We have conducted a numerical simulation under three-dimensional unsteady conditions in order to analyze the characteristics of $CO_2 $;, extinguishant transfer by varying the location of the injection nozzle, which affects the effect of a $CO_2 $;, fire fighting system used in the form of fixed systems for the marine engine room. Flow fields and $CO_2 $;, concentration fields were measured according to the location of the injection nozzle. In the case of arranging the injection nozzle on the center of the ceiling, the low-normal concentration distribution was developed along the $CO_2 $;, jet due to the downward flow created by impinging ceiling jets in the symmetric plane. The concentration line reaches its peak due to the mass transfer of $CO_2 $;, at the comer.

Effects of Different Carbon Dioxide and Oxygen Concentration on the Quality of Oriental Melon during CA Storage (참외 CA저장시 $CO_2$$O_2$농도에 따른 품질 변화)

  • 이숙희;김창배;서영진;김찬용;윤재탁
    • Food Science and Preservation
    • /
    • v.6 no.4
    • /
    • pp.386-391
    • /
    • 1999
  • Oriental melon was stored in controlled atmospheres(5, 10 or 15% CO$_2$in combination with 3 or 10% O$_2$) and air as control, and was analyzed half monthly during a 45-day storage for various quality Parameters. Oriental melon which stored in CA condition was lower in weight loss and decay rate than that stored in air. There was no significant difference in firmness by CO$_2$or O$_2$concentration during a month of storage. Fruits stored in 10% CO$_2$+3% O$_2$showed higher level of soluble solids, Vitamin C content and L value than other condition. And also comparatively lower endogenous ethanol accumulation and better state of quality was observed in that condition.

  • PDF