• Title/Summary/Keyword: $COD_s$

Search Result 699, Processing Time 0.024 seconds

Feeding Habits of the Pacific Cod Gadus macrocephalus in Southeast Sea of Korea (한국 남동부해역 대구 Gadus macrocephalus의 식성)

  • Lee, Jeong-Hoon;Kim, Jung Nyun;Park, Junsu;Park, Tamina;Nam, Ki Mun
    • Korean Journal of Ichthyology
    • /
    • v.27 no.2
    • /
    • pp.142-148
    • /
    • 2015
  • The feeding habits of the Pacific cod Gadus macrocephalus were studied using 620 specimens collected by bottom trawl and pound net in the Southeast sea of Korea, from February 2012 to June 2013. Of 620 specimens, 192 contained food and 428 were empty. The total length (TL) of individuals used in this study ranged from 20.4 to 95.2 cm. Pacific cod mainly consumed Pisces, Macrura, and Cephalopoda. Its diet also included small quantities of Anomura, Brachyura, Mysidacea, Isopoda and Amphipoda. The proportion of Pisces in prey items increased with increasing Pacific cod length, but seasonal difference was not observed. The proportion of Macrura and Cephalopoda decreased with growth, and seasonal differences were apparent. Macrura were taken there mainly from autumn to winter, whereas Cephalopoda were consumed from spring to summer.

Analysis of Nonpoint Sources Runoff Characteristic for the Vineyard Areas (포도밭에 대한 비점오염원 유출특성 해석)

  • Yoon, Young-Sam;Lee, Sang-Hyeup;Yu, Jay-Jung;Lee, Jae-Kwan
    • Journal of Environmental Science International
    • /
    • v.20 no.3
    • /
    • pp.361-372
    • /
    • 2011
  • This study analyzed the characteristics of stormwater runoff by rainfall type in orchard areas for two years. Effluents were monitored to calculate the EMCs and runoff loads of each pollutant. The runoff characteristics for nonpoint sources from vineyards were also inspected based on independent variables that affect runoff such as rainfall and rainfall intensity. The average runoff loads of each pollutant from vineyard_A and vineyard_B were found as follows: BOD 39.13 mg/$m^2$, COD 112.13 mg/$m^2$, TOC 54.98 mg/$m^2$, SS 1,681.8 mg/$m^2$, TN 18.29 mg/$m^2$, and TP 4.06 mg/$m^2$, which indicates that the COD's runoff load was especially high. The average EMCs from vineyard_A and vineyard_B, which represents the quality of rainfall effluent, were also analyzed: BOD 3.5 mg/L, COD 11.5 mg/L, TOC 5.2 mg/L, SS 211.7 mg/L, TN 1.774 mg/L, and TP 0.324 mg/L. This suggested that the COD, as an indicator of organic pollutants, is high in terms of EMCs as well. As rainfall increased, the EMCs of BOD, COD, TOC and SS kept turning upward. At a point, however, the high rainfall brought about dilution effects and began to push down the EMCs. Higher rainfall intensities led to the increase in the EMCs that displays the convergence of rainfall. Low rainfall intensities also raised pollutant concentrations, although the concentrations themselves were slightly different among pollutants.

Fracture Behavior of Pre-cracked AISI 4130 Specimens by Means of Acoustic Emission and Ultrasonic C-scan Measurements (음향방출과 초음파 C-scan을 이용한 AISI 4130 균열재의 파괴거동 연구)

  • Ong, J.W.;Moon, S.I.;Jeong, H.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.3
    • /
    • pp.7-13
    • /
    • 1993
  • Fracture behavior of pre-cracked compact tension specimens made of AISI 4130 steel was investigated using acoustic emission (AE) and ultrasonic C-scan measurements. While each specimen was loaded up to a certain level, various acoustic emission parameters were recorded together with the crack opening displacement (COD). An elastic-plastic finite element analysis was performed to calculate COD and the damage (plastic) zone size ahead of crack tip. Ultrasonic C-scans, in a pulse-echo, immersion mode, were done for mapping the damage zone size. The agreement between the finite element results and the measured COD was satisfactory. Based on AE results, the test specimens were found to show ductile behavior. The slope of the total ringdown counts vs. COD curve was useful to determine the crack initiation. The preliminary C-scan images showed evidence of changes in the amplitude of ultrasonic signal in the damaged region, and the shape and size of the damage zone matched qualitatively with the finite element results. A further work on the damage zone sizing was also pointed out.

  • PDF

Analysis of COD fraction and change of COD in nitritation reactor using various wastewater (다양한 하수를 대상으로 유기물 성상과 질산화 반응조 내 유기물 변화)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.17 no.4
    • /
    • pp.421-427
    • /
    • 2015
  • In ASM model, organic matters are classified according to their characteristics and general classification into COD and BOD cannot satisfy conditions required by ASM. In this study, it was performed to study classification of organic matters required by ASM on the basis of microorganisms' respiration rate subject to wastewater and sludge treatment. As results of analysis of the organic matter's appearance, it was found that there were some differences in composition of organic matters between wastewaters. It is considered that it is an important characteristic of wastewater that should be understood in treating wastewater in each process. Therefore, it is considered that appearance of organic matters in each wastewater identified by this study will be used as important basic data for operation of municipal wastewater treatment plant. It was identified that SS was an important factor affecting nitrification through organic matter and ammonium nitrogen change analysis according to reaction time in the nitrification. It is considered that the nitrification has close relationship with choice of optimal retention time.

Study of COD Removal Efficiency from Synthetic Wastewater by Photocatalytic Process

  • Rojviroon, Orawan;Rojviroon, Thammasak;Sirivithayapakorn, Sanya
    • Environmental Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.255-259
    • /
    • 2014
  • In this research, we compared the COD removal efficiencies of titanium dioxide ($TiO_2$) thin films coated on the surfaces of borosilicate glass that prepared by three different numbers of coating layer; i) 3 layers ii) 4 layers and iii) 5 layers by sol-gel method. All of the prepared $TiO_2$ thin films consisted of pure anatase crystalline structure with grain sizes in the range 20-250 nm. The calculated optical band gaps of the $TiO_2$ thin films were 3.24. The total apparent surface area per total weight of $TiO_2$ thin films were 4.74, 3.86 and $2.79m^2g^{-1}$ for 3, 4 and 5 layers coating, respectively. The kinetics of the photodegradation reactions of COD under UVA light source were described by the Langmuir-Hinshelwood (L-H) kinetic model. The specific rates of the photodegradation of $TiO_2$ thin films at 3 layers coating was $1.40{\times}10^{-4}min^{-1}mW^{-1}$, while for the 4 layers coating and the 5 layers coating were $1.50{\times}10^{-4}$ and $4.60{\times}10^{-4}min^{-1}mW^{-1}$, respectively. The photocatalytic performance of COD degradation was higher with smaller grain size, higher surface area and narrow optical band gaps. Moreover, the numbers of coating layer on substrate also have great influence for kinetic of COD removal.

Minimization of Excess Activated Sludge in Nonwoven Fabric Filter Bioreactor (부직포 여과막 생물반응조에서의 폐활성슬러지 감량화)

  • Jung, Kyoung-Eun;Bae, Min-Su;Cho, Yun-Kyung;Cho, Kwang-Myeung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.88-96
    • /
    • 2006
  • Among the various methods for minimization of waste activated sludge, maintaining a low F/M ratio in the bioreactor is known to be the most effective reliable one. In this research, various experiments were performed to check the capability of the nonwoven fabric filter bioreactor, which has been proved able to maintain a low F/M ratio by maintaining a high MLSS concentration, for excess sludge minimization. The reactor was intermittently fed with a synthetic wastewater having a COD concentration of approximately 300 mg/L and no SS. Results of the experiments showed that the F/M ratio in the reactor decreased to a minimum value of 0.02 g COD/g MLSS-day as the MLSS concentration increased to a maximum value of 31,010 mg/L. However, the measured endogenous decay coefficients and oxygen uptake rates of the MLSS confirmed that the activity of the MLSS decreased as the MLSS concentration increased. Based on the increase of MLSS in the reactor and the mass balance during the whole experimental period, the average microorganism yield coefficients were computed to be low values of 0.148 and 0.139 g MLSS/g COD, respectively. These results indicate that the nonwoven fabric filter bioreactor employed in this research is effective for minimization of excess sludge production.

A Study on Model Based Optimum Design of Oxidation Ditch in Sewage Treatment (산화구 하수처리공정의 최적설계에 관한 기초연구)

  • Dho, Hyonseung
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.2
    • /
    • pp.25-34
    • /
    • 2019
  • The efficiency of sewage treatment was analyzed by statistical method based on the water quality and operation data of the sewage treatment plant applying the oxidation method. The obtained water quality data were pH, temperature, BOD, SS, T-N, ${NH_4}^+-N$, and T-P of influent and discharge water. Data analysis was performed by correlation analysis, ANOVA analysis, and cluster analysis. As a result of the statistical analysis, the influent flow rate in the sewage treatment plant was the highest in summer. The average inflow flow rate was $3.000m^3/s$. According to Box plot results, COD, and T-P concentrations of effluents were not significantly different from season to season. The Pearson correlation analysis showed strong positive correlation between BOD, COD, T-N, and T-P in influent flow. Seasonal BOD and T-N concentrations were highest in winter and COD and T-P in seasonal influences. BOD showed a strong negative correlation with the water temperature, but showed a positive correlation with other operating factors such as HRT, SRT and C/N. The higher the influent temperature, the lower the BOD concentration. Therefore, retention time was shortened and BOD treatment efficiency was lowered. It was found that T-N had a higher retention time and a higher concentration than DO concentration. On the other hand, T-P did not show a significant correlation with operating factors.

Acute Toxicity on Daphnia Magna for Electric Cable Factory Wastewater (물벼룩에 의한 전선공장폐수의 급성독성가)

  • Chae, Su-Gwon;Kim, Nam-Cheon;Kim, Geon-Heung
    • Water for future
    • /
    • v.25 no.2
    • /
    • pp.61-66
    • /
    • 1992
  • This study was to determine the static acute toxicity on Daphnia magna for the Electric cable Factory Wastewater. Activated sludge process was used to treat the wastewater with three different F/M ratios, 0.36, 0.2, 0.1 mg COD/day.mg MLSS. The results of laboratory bioassay with Daphnia magna were as follows. 1)24hr, 48hr-LC$ of the influent were 17.33% and 11.73%. 2)24hr-LC $ of effluents treated with F/M ratio 0.36,0.26 and 0.1mg COD/day.mg MLSS were 26.69% 32.70% and 38.36% respectively, 48-LC$ of these effluents were 14.48% 27.88% and 31.58% respectively. 3)According to various F/M ratios, the ratios of dffluent 48hr-LC$ to filtrated 48hr-LC$ were 1.58, 1.83 and 1.47respectively 4)Activated sludge process effluents treated with activated carbon had little toxicity on Daphnia magna.

  • PDF

Growth of Yeasts in Alcohol Distiller′s Waste of Dried Sweet Potato for Single-cell Protein Production and BOD Reduction (절간고구마원료 주정폐액을 이용한 단세포단백질의 생산 및 폐액의 BOD제거)

  • 이형춘;구영조;민병용;이홍근
    • Microbiology and Biotechnology Letters
    • /
    • v.10 no.2
    • /
    • pp.95-100
    • /
    • 1982
  • Torulopsis candida FRI YA-15, a selected yeast, was cultivated in alcohol distiller's waste-filtrate of dried sweet potato for microbial protein production and BOD reduction. The General composition of waste-filterate was BOD$_{5}$ 15700 ppm, COD 36800 ppm, reducing sugar 3300 ppm, total nitrogen 910 ppm, total solids 51800 ppm and ash 390 ppm. The pH of waste was 3.85. The yield to the medium of T. candida cultivated in shake-flask at $25^{\circ}C$ for 48 hrs was 3.38g/$\ell$ and effectiveness in reducing BOD$_{5}$ and COD of waste was 38.9% and 31.8%, respectively. In batch cultivation using 3 $\ell$-jar fermenter, maximum yield to the medium reached 3.2g/$\ell$after 28 hrs cultivation under the condition of temperature 35$^{\circ}C$, initial pH 4.0, aeration rate 2vvm, agitation speed 100rpm. Dry yeast was composed of crude protein 47.98% and ash 5.23%.

  • PDF

Long Term Monitoring of Storm Surface Runoff from Urban Pavement Road in Korea

  • Lee, C.S.;Seo, G.T.;Lee, J.H.;Yoon, Y.S.;You, J.J.;Sin, C.K.
    • Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.184-191
    • /
    • 2008
  • Long term monitoring was conducted to investigate a surface runoff of pollution from urban highway. The monitoring data was collected for 18 rainfall events and was used to correlate pollution load to various parameters, such as rainfall intensity, antecedent dry days and total discharge flow. Runoff coefficient and seasonal variation were also evaluated. The mean runoff coefficient of the highway was 0.823(range; $0.4687{\sim}0.9884$), and wash-off ratio for $COD_{Mn}$ and SS loads was 72.6% and 64.3%, respectively. For the initial rainfall event, the runoff EMC of $COD_{Mn}$ was high in summer and the EMC of SS was high in autumn season. However the seasonal variation of T-N and T-P was not significant. The discharged $COD_{Mn}$-EMC was $147.6\;mg/L{\sim}9.0\;mg/L$ on the generated $COD_{Mn}$-EMC of $98.8\;mg/L{\sim}8.9\;mg/L$. While the generated EMC of SS was in $285.7\;mg/L{\sim}20.0\;mg/L$ and its discharged EMC was in $190.4\;mg/L{\sim}8.0\;mg/L$. EMC of pollutants was not directly related to the first flush rainfall intensity and the antecedent dry days. But the correlation was relatively high between EMC and cumulative runoff flow volume. The trend of EMC was reduced with the cumulative runoff flow volume.