• Title/Summary/Keyword: $COD_T$

Search Result 854, Processing Time 0.029 seconds

Studies on the Biological Treatment of Dye Waste Water and Degration of Polyvinyl Alcohol (염색공장 폐수중 PVA 분해세균의 분리 및 생물학적 처리효과)

  • 강선태;서승교;권오억
    • Journal of Environmental Health Sciences
    • /
    • v.16 no.1
    • /
    • pp.21-28
    • /
    • 1990
  • As a research for treatment of waste water by biological method, we investigated general characteristics of waste water and isolated some useful bacteria which effectively treated waste water. Compositions of waste water were analyzed to give COD 2060 ppm, PVA 560 ppm, T-N 50 ppm, T-P 3.3 ppm and PH 12. Also, we inverstigated optimum nutrients requirement and growth conditions by mixed culture as well as the effect of coagulants. The COD removal rate reached maximum state for 48 hrs culture at pH 7.0 and 30$^{\circ}$C. Alum as the coagulated was the most effective. The COD removal rate was also increased by supplementing 10 ppm phosphorous sources as additional nutrients. The COD of waste water was reduced to 10% of its initial value by the continuous culture. As a result of overall experiments the COD of effluents became about 100 ppm and final pH 7.

  • PDF

The Single- and Two-Phase Anaerobic Digestion of Food Waste Effluent (단상 및 이상혐기소화공정을 이용한 음폐수의 바이오에너지화)

  • HwangBo, Jun-Kwon;Seo, Jae-Gun;Yoon, Heui-Chul;Park, Hyeon-Gun;Lee, Bo-Won
    • Land and Housing Review
    • /
    • v.2 no.1
    • /
    • pp.87-92
    • /
    • 2011
  • The anaerobic digestion of food waste effluent through single- and two-phase process was estimated and compared in this study. The treatment efficiencies for total solid(TS), volatile solid(VS), tCOD(total COD) and sCOD(soluble COD) were invariably higher in the single-phase process, which was accounted for by the fact that the treatment efficiency of organic wastes usually showed an inverse relationship with organic loading rate in the anaerobic digestion. In fact, the organic loading rate was lower for single-phase process. The concentration of tCOD were significantly lower in two-phase process but much more biogas was produced, compared to single-phase anaerobic digestion process, which might be explained partly by the relatively higher stability of two-phase process resulting from the separation of acid phase from methane phase.

Parameter Estimation of the Aerated Wetland for the Performance of the Polluted Stream Treatment (오염하천 정화를 위한 호기성 인공습지의 운영인자 평가)

  • Kim, Dul-Sun;Lee, Dong-Keun
    • Clean Technology
    • /
    • v.25 no.4
    • /
    • pp.302-310
    • /
    • 2019
  • A constructed wetland with the aerobic tank and anaerobic/anoxic tank connected in series was employed in order to treat highly polluted stream water. The aerobic tank was maintained aerobic with a continuous supply of air through the natural air draft system. Five pilot plants having different residence times were employed together to obtain parameters for the best performances of the wetland. BOD and COD removals at the aerobic tank followed the first order kinetics. COD removal rate constants were slightly lower than BOD. The temperature dependence of COD (θ = 1.0079) and BOD (θ = 1.0083) was almost the same, but the temperature dependence (θN) of T-N removal was 1.0189. The SS removal rate was as high as 98% and the removal efficiency showed a tendency to increase with increasing hydraulic loading rate (Q/A). The main mechanism of BOD and COD removal at the anaerobic/anoxic tank was entirely different from that of the aerobic tank. BOD and COD were supplied as the carbon source for biological denitrification. T-P was believed to be removed though the cation exchange between orthophosphate and gravels within the anaerobic and anoxic tanks. The wetland could successfully be operated without being blocked by the filtered solid which subsequently decomposed at an extremely fast rate.

A study on the effect of the water purification by Lythrum anceps, Pistia straiotes, Oenanthe javanica, and Phragmites japonica (부처꽃, 물상추, 미나리, 달뿌리풀의 수질정화효과에 관한 연구)

  • Cho, Hae-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.2
    • /
    • pp.380-384
    • /
    • 2007
  • The COD removal capacity of aquatic plants, when foamed glasses were not used, showed 56% for Pistia straiotes, 48% for Phragmites japonica and 41% for Oenanthe javanica, but no significant COD removal was observed for Lythrum anceps. When the foamed glasses were used as support materials, the COD removal efficiency increased for all aquatic plants used in this study showing 69% fur Pistia straiotes, 68% for Pharagmites japonica 62% for Oenanthe javanica, respectively. The T-N removal efficiency of aquatic plants when foamed glasses were used as support materials showed 91% for Lythrum anceps and 93% for Phragmites japonica. Similar removal efficiency was observed as 94% for all aquatic plants planted as a group used in this study. The T-P removal efficiency of aquatic plants when foamed glasses were not used showed 35% for Lythrum anceps, 8% for Phragmites japonica, however, that, when foamed glasses were used, ranged 78% for Lythrum anceps, 43% for Phragmites japonica, showing that the foamed glasses increase the T-P removal efficiency of aquatic plants used in this study.

  • PDF

Water Quality Correlation Analysis between Sewage Treated Water and the Adjacent Downstream Water in Nakdong River Basin (낙동강유역의 하수처리장 방류수와 인접 하류하천의 수질상관관계 분석)

  • Cho, Hyun Kyung;Kim, Sang Min
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.2
    • /
    • pp.202-209
    • /
    • 2018
  • The purpose of this study was to analyze the correlation between the effluent of a sewage treatment plant (STP) and the adjacent stream located downstream of the STP in Nakdong River. Flow and water quality data, such as BOD, COD, SS, T-N, and T-P data, for 12 STPs and adjacent downstream monitoring stations in the main stream and tributaries of Nakdong River were collected from 2012 to 2015. As a result of correlation analysis between river flow and water quality at the river water quality measurement point, COD, SS, and T-P were correlated positively with the river flow rate at 6, 8, and 6 points, respectively. As a result of analyzing the water quality of sewage treatment plant effluents and downstream streams, BOD and COD were correlated at 2 and 3 points, respectively. T-N showed a positive correlation at 9 points, and 7 of them had a strong positive correlation, indicating that sewage treatment effluent had a large effect on downstream streams. In this study, we found that the correlation between the river flow rate and the water quality factors (COD, SS, TP) was high at river water measurement points, and the sewage treatment plant effluent was correlated with the T-N value of adjacent streams.

Water Quality Correlation Analysis between Sewage Treated Water and the Adjacent Downstream Water in Nakdong River Basin (낙동강유역의 하수처리장 방류수와 인접 하류하천의 수질상관관계 분석)

  • Cho, Hyun Kyung;Kim, Sang Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.493-493
    • /
    • 2018
  • The purpose of this study was to analyze the correlation between the effluent of the sewage treatment plant (STP) and the adjacent stream located downstream of the STP in Nakdong River. The flow and water quality such as BOD, COD, SS, T-N, and T-P data for 12 STPs and adjacent downstream monitoring stations in the main stream and tributaries of Nakdong River were collected from 2012 to 2015. As a result of correlation analysis between river flow and water quality at the river water quality measurement point, COD, SS and T-P were correlated positively with river flow rate at 6, 8, and 6 points, respectively. As a result of analyzing the water quality of sewage treatment plant effluent and downstream stream, BOD and COD were correlated at 2 and 3 points, respectively. T-N showed a positive correlation at 9 points, and 7 of them had a strong positive correlation, indicating that sewage treatment effluent had a large effect on downstream streams. In this study, we found that the correlation between river flow rate and water quality factors (COD, SS, TP) was high for river water measurement points, and the sewage treatment plant effluent was correlated with the T-N value of adjacent streams.

  • PDF

Performance Evaluation of Anaerobic Bioreactors in Treating Swine Wastewater (양돈폐수 처리를 위한 혐기성 생물반응기의 성능 비교)

  • Kim, Jong-Soo;Lee, Gook-Hee;Sa, Tongmin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.11
    • /
    • pp.2047-2058
    • /
    • 2000
  • The effects of operating parameters on performance of upflow anaerobic sludge blanket(UASB). anaerobic filter(AF), and two-stage anaerobic sludge bed filter (ASBF) bioreactors in treating swine wastewater were evaluated by operating the lab-scale bioreactors upto hydraulic retention time(HRT) of 1 day and organic loading rate (OLR) of $5.1kg-COD/m^3{\cdot}d$ for 200 days. Swine wastewaters of which characteristics were affected by types of hog raising and seasons contained high concentrations of COD, SS, and ammonia. Inoculation of the bioreactors with waste sludge from anaerobic treatment facility of local municipal wastewater treatment plant was effective in developing biomass in the bioreactors. Acclimation period of the bioreactors with swine wastewaters required approximately 40 days, but that for AF and two-stage ASBF, which were filled with media, was faster than VASB. The bioreactors showed high and stable COD removal efficiency of 77~91% at influent T-N concentrations of 370~800mg/L but low and unstable COD removal efficiency of 24~94% at influent T-N concentrations of 760~1,310mg/L. It is essential to remove ammonia prior to anaerobic treatment since the concentrations of ammonia in swine wastewaters showed toxic effects to methanogenic bacteria. The bioreactors were effective in treating swine wastewaters with COD removal efficiency of 78.9~81.5% and biogas generation rate of $0.39{\sim}0.59m^3/kg-COD_r$ at OLR of $1.1{\sim}2.2kg-COD/m^3{\cdot}d$: however, an increase of OLR by reducing HRT and increasing influent COD caused decrease of COD removal efficiency. The extent of decrease in COD removal efficiency was higher in UASB than AF and two-stage ASBF. AF and two-stage ASBF anaerobic bioreactors were effective in treating varing characteristics of swine wastewaters since they showed high and stable COD removal efficiency at high OLR due to effective retention of biomass by media and staging.

  • PDF

Buffering effects of shock loads in sequencing batch reactor (SBR에서 충격부하에 따른 완충효과)

  • Ji, Dae-Hyun;Lee, Kwang-Ho;Lee, Jae-Kune
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.5
    • /
    • pp.581-587
    • /
    • 2008
  • In this study, we investigated the buffering effect with different COD, $NH_4{^+}-N$ and TP shock loads on the performance of lab-scale Sequencing Batch Reactor(SBR) using synthetic wastewater. This study was operated under the following conditions : HRT, 12 hrs : MLSS, 2,000 mg/L : F/M ratio, $0.2kgCOD/kgMLSS{\cdot}d$ : SRT, 20days, and was increased by a factor, COD : ranging from 200-2000 mg/L, $NH_4{^+}-N$ : ranging from 30-300 mg/L, T-P : ranging from 5-50 mg/L in the reactor. As results, COD removal rate at different shock loads was decreased until 42.1%(stable state : 95%) and concentration with effluent was higher than 695 mg/L(at Run 6). In case of $NH_4{^+}-N$ removal rate was decreased until 35.8% from 97.0% and also T-P removal rate was decreased until 5.0%. Effluent concentrations of COD, $NH_4{^+}-N$ and T-P were rapidly increased according to shock loads and needed 3, 4 and 6 additional cycle times for recovering the stable condition.

Effect of Solidified/Stabilized Sewage Sludge using Neutral Solidifying Chemical Agent and Alkaline Agent as Landfill Cover on Decomposition of Organic Matter in Lysimeter (중성계 및 알칼리성 고화재를 이용한 고화하수슬러지의 복토재가 모형매립조 내 유기물 분해에 미치는 영향)

  • Kim, Hye-Jin;Park, Jin-Kyu;Song, Sang-Hoon;Lee, Nam-Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.8
    • /
    • pp.768-774
    • /
    • 2008
  • To evaluate the effect of the solidified/stabilized sewage sludge on landfill sites, lysimeter tests were conducted. Lysimeters (LR1, LR2, and LR3) were filled with the material(Compost : Fodder : Sand = 10 : 10 : 80) and covered with different types of the cover soils, the G solidified sludge produced from the neutral solidifying chemical agent(LR1), the A solidified sludge produced from the alkali solidifying chemical agent(LR2), and the weathered granite soil(LR3). Those lysimeters were kept at the temperature controlled room with 30 $\pm$ 2$^{\circ}C$ for about 450 days. As the results, it was appeared LR2 > LR1 > LR3 that total gas production rate(L), gas production rate(L/VS(kg)) and cumulative gas(CO$_2$ + CH$_4$) production. There were not significant differences at decrease of the COD$_{Cr}$ in the leachate from LR1 and LR3. Thus, it had been shown that the use of the G solidified sludge as cover soil did not affect the COD$_{Cr}$ in the leachate. The COD$_{Cr}$ from LR2 had been increased since around 250 days because solidified/stabilized sewage sludge became re-slurry. T-N and T-P from LR3 also were higher than LR1 and LR2. Also were, the use of the solidified/stabilized sewage sludge as a cover soil, therefore, did not affect the T-N and T-Pconcentrations in the leachate.

Comparison of Water Quality Before and After Four Major River Project for Water Monitoring Stations Located Near 8 Weirs in Nakdong River (낙동강 8개 보 인근 수질측정 지점의 4대강 사업 전·후 수질 변동성 분석)

  • Cho, Hyun Kyung;Lim, Hyo Jin;Kim, Sang Min
    • Journal of agriculture & life science
    • /
    • v.52 no.6
    • /
    • pp.89-101
    • /
    • 2018
  • The purpose of this study was to evaluate the variation of water quality in the Nakdong River by the Four major river projects. For this purpose, the nearest upstream water quality monitoring stations were selected and water quality data such as BOD, COD, SS, TN, TP, and TOC were collected for the before Four major river project(from January 2003 to November 2008), during the project(from September 2008 to April 2012) and after the project(from May 2012 to September 2017). As a result, the concentration of DO, BOD, COD, TN, and TOC after the project tend to be higher than the before project period. On the other hand, the SS and T-P values decreased after the project. Spatial analysis of BOD, COD, and TOC, which have large changes in water quality factor, by water quality grade, showed a tendency that water quality grade after the project was worse than before the project.