• 제목/요약/키워드: $COD_{cr}$

검색결과 332건 처리시간 0.022초

가정하수를 cosubstrate로서 사용한 하수-염색폐수-공장폐수의 합병 고도처리 pilot plant 연구 (Pilot Study on the Advanced Treatment of Combined Wastewater with Sewage as a Cosubstrate)

  • 김미경;서상준;류덕희;정동일
    • 한국물환경학회지
    • /
    • 제25권2호
    • /
    • pp.227-234
    • /
    • 2009
  • In this research, a retrofitting process, which consists of a pretreatment system (coagulation) for dye wastewater combined with a biological nutrient system (MLE process using media), for a sewage treatment plant that has to treat dye wastewater efficiently with domestic wastewater were developed and a pilot plant was operated for verifying adoptability and performance of the developed advanced process for dye wastewater. From the results of the pilot plant operation, BOD 52.9%, $COD_{Cr}$ 55.9%, and color 71.3% were removed in pretreatment of coagulation process and the biodegradability of dye wastewater was improved to $0.32{\sim}0.59BOD/COD_{Cr}$ of the coagulated wastewater from $0.29{\sim}0.43BOD/COD_{Cr}$ of the raw dye wastewater. The final effluent concentrations were BOD of 8 mg/L, $COD_{Cr}$ of 43 mg/L, $COD_{Mn}$ of 18 mg/L, T-N of 8 mg/L, and T-P of 1.3 mg/L, respectively. Color was removed from 1655 to 468 unit by coagulation and then to 123 unit by MLE process. The HPLC analysis of aromatic amines in wastewater showed that decolorization was achieved by cometabolism while aromatic amines were produced by cleavage of azo bonds under anaerobic conditions and these products were removed in an aerobic tank subsequently. Nitrification rates of attached and suspended microorganisms were evaluated comparatively and the acclimating conditions of bacteria on media were validated by the scanning electron microscope.

강우 시 도시 하천으로의 비점오염원 유출특성 (The runoff characteristics of non-point source to urban stream during rainfall)

  • 박운지;김동욱;안종화;이찬기
    • 산업기술연구
    • /
    • 제27권B호
    • /
    • pp.83-89
    • /
    • 2007
  • We studied runoff characteristics of combined sewer overflows in a city while it was raining. The event mean concentration (EMC) of biochemical oxygen demand (BOD), chemical oxygen demand ($COD_{Cr}$), suspended solids (SS), total nitrogen (TN), and total phosphorus (TP) in one of the combined sewer sites in Chuncheon was 63.5-211.6 mg/L, 114.9-523.8 mg/L, 70.3-436.4 mg/L, 6.4-33.0 mg/L, and 1.09-6.81 mg/L, respectively. In another combined sewer, the EMC of BOD, COD, SS, TN, and TP was 42.1-131.4 mg/L, 107.7-256.5 mg/L, 33.7-221.1 mg/L, 7.9-26.4 mg/L, and 1.16-3.91 mg/L, respectively. The ratio of the cumulative pollutant mass and the cumulative discharged volume determined using all parameters (BOD, $COD_{Cr}$, SS, TN, and TP) was over 1.0, which shows the first flush effect. Relationships between flow and loadings of BOD, $COD_{Cr}$, SS, TN, and TP were 0.90, 0.89, 0.88, 0.89, 0.92, respectively. Although the size of two areas was almost same, pollutant concentration and loading were different because of the amount of rainfall, rainfall intensity and basin area.

  • PDF

분리막과 증발기를 이용한 매립지 침출수 처리에 관한 연구 (Lab test) (A Study on the Treatment of Landfill Leachate using Membrane and Evaporator (Lab Test))

  • 강신경;박영규
    • 대한환경공학회지
    • /
    • 제22권12호
    • /
    • pp.2125-2134
    • /
    • 2000
  • 본 연구는 매립지에서 발생되는 침출수를 배출허용기준 이내로 처리함은 물론 경제적인 처리 공정을 개발하기 위한 것이다. 이를 위해 현장 pilot test 이전에 최적 공정 선정과 장치 설계인자를 도출하기 위해 실험실에서 기초실험을 수행하였다. 본 연구에서 개발하고자하는 처리공정은 역삼투시스템을 이용하는 공정인데 전처리로서 침지형분리막 생물반응기를 이용하였으며, 역삼투시스템에서 발생되는 농축수는 매립가스를 열원으로 하는 직화식 증발기를 이용하여 처리하는 공정이다. 실험결과 침지형분리막 생물반응기에서 SS, $BOD_5$, $COD_{cr}$, $NH_4{^+}-N$은 각각 99.0%, 43.0%, 12.9%, 48.5%, 18.7%의 제거효율을 보였다. 역삼투시스템온 $BOD_5$, $COD_{cr}$, $NH_4{^+}-N$, T-N을 각각 97.5%, 97.6%, 79.7%, 85.4% 제거할 수 있었다. 증발기는 $COD_{cr}$, $NH_4{^+}-N$, T-N을 각각 90.5%, 50.6%, 63.3% 제거할 수 있었으나 배출허용기준 이내로 처리하기는 어려운 것으로 나타나 응축수는 역삼투시스템 전단으로 보내서 전처리수와 함께 처리되어야할 것으로 나타났다.

  • PDF

기원별 용존 유기물의 분광특성 및 COD 산화율 비교 (Comparison of Spectroscopic Characteristics and Chemical Oxygen Demand Efficiencies for Dissolved Organic Matters from Diverse Sources)

  • 정가영;박민혜;허진;이승윤;신재기
    • 한국물환경학회지
    • /
    • 제25권4호
    • /
    • pp.589-596
    • /
    • 2009
  • The spectroscopic characteristics and chemical oxygen demand (COD) oxidation efficiencies were investigated for dissolved organic matters (DOM) from diverse sources, which may indirectly affect the concentrations and the quality of DOM found in watersheds. The DOM investigated for this study showed a wide range of the percent distributions of refractory organic matter (R-OM) from 8 to 100%. Relatively high R-OM distributions were observed for the DOM with the source of head water, sediments, paddy soils, field soils, and treated sewage whereas the DOM from livestock waste, reed, weeds, algae, and attached algae exhibited lower R-OM percent distributions. The percent distribution of R-OM had positive correlations with specific UV absorbance (SUVA) and humidification indices (HIX) of DOM. The investigated DOM was classified into four different source groups (i.e., biota, vegetables, soils, sediments) by comparing the synchronous fluorescence spectra. The DOM group from biota source was characterized by a prominent presence of protein-like fluorescence (PLF) whereas fulvic-like fluorescence (FLF) was additionally observed for vegetable-source DOM. FLF became significant for the DOM from both soils and sediments although no PLF was found for soil-derived DOM. A range of COD oxidation efficiency was observed for the various DOM, ranging from 36 to 94% and from 65 to 125% for $COD_{Mn}$ and $COD_{Cr}$, respectively. The results indicate that $COD_{Cr}$ reflects the higher OM concentration than $COD_{Mn}$. However, 95% confidence intervals of the COD oxidation efficiencies were similar for the two types of COD, suggesting that $COD_{Cr}$ may not be the superior OM index to $COD_{Mn}$ in terms of the variability of the oxidation efficiency. No significant correlations were obtained between COD oxidation efficiencies and the spectroscopic characteristics of DOM for this study.

여과한 하수와 하수원액의 VFAs 측정과 미생물 호흡률 측정법을 이용한 하수의 유기물 분액 방법에 관한 연구 (A Study of Organic Matter Fraction Method of the Wastewater by using Respirometry and Measurements of VFAs on the Filtered Wastewater and the Non-Filtered Wastewater)

  • 강성욱;조욱상
    • 유기물자원화
    • /
    • 제17권1호
    • /
    • pp.58-72
    • /
    • 2009
  • 본 연구에서는 하수 내에 존재하는 유기물과 미생물량 분액을 위해 미생물 호흡률 측정기(Respirometer)를 구동하여 미생물에 의한 산소 섭취율(OUR : Oxygen Uptake Rate)을 측정하고, CG-FID 혹은 LC를 활용하여 VFAs(Volatile Fatty Acids)를 측정하였다. 유기물은 IAWQ (International Association of Water Quality)의 ASM(Activated Sludge Model)에서 명시된 유기물 분류법에 따라 분액 하였으며, ASM 중에서도 ASM No.2d를 기초하여 분액을 수행하였다. 하지만 슬러지를 첨가하지 않은 하수 원액의 미생물 호흡률 측정과 더불어 기존의 방법과는 다르게 여과한 하수의 미생물 호흡률 측정과 VFAs 측정을 수행하여 하수에 포함된 유기물량을 추정하였다. 이는 기존의 하수 원액을 이용한 미생물 호흡률 측정 방법에 있어 천천히 생분해되는 용존성 유기물질(S_S)에 의한 산소섭취율과 천천히 생분해되는 입자성 유기물질(X_S)에 의한 산소섭취율이 동일 그래프 안에 형성되어 정확하게 구분되지 못하는 단점과 슬러지 세척으로 인한 실험의 오차를 보완하고자 하였다. 또한 용존성 난분해 COD(S_I)을 측정하는 기준이 명확하지 않는 문제점이 발생하여 미생물 호흡률 측정 과정에서 그래프의 변화를 보고 정확한 용존성 난분해 COD(S_I)의 측정 시간을 선택할 수 있는 방법을 제시하였다. 여과한 하수를 대상으로 미생물 호흡률 측정과 VFAs 측정을 통하여 추정한 유기물 분액 결과 용존성 난분해 COD인 S_I는 $12.2g/m^3$로 Total $COD_{Cr}$ 기준으로 6.9%, 발효 부산물인 S_A는 $24.76g/m^3$로 Total $COD_{Cr}$ 기준으로 14.1%, 발효 가능한 유기물질인 S_F는 $58.54g/m^3$로 Total $COD_{Cr}$ 기준으로 33.2%, 천천히 생분해되는 입자성 유기물질인 X_S는 $61.1g/m^3$로 Total $COD_{Cr}$ 기준으로 34.7%, 입자성 난분해 COD인 X_I는 $10.2g/m^3$로 Total $COD_{Cr}$ 기준으로 5.8%로 추정되었다. 종속영양 미생물량인 X_H는 $9.3g/m^3$로 Total $COD_{Cr}$ 기준으로 5.3%로 추정되었다.

제올라이트 칼럼에 의한 인공생활하수의 COD 및 BOD 제거에 관한 연구 (COD and BOD Removal of Artificial Municipal Wastewater by a Column filled with Zeolite)

  • 서정윤
    • 한국습지학회지
    • /
    • 제3권1호
    • /
    • pp.75-89
    • /
    • 2001
  • Constructed wetlands were typically cost less to build and operate, and require less energy than standard mechanical treatment technology but they have similar performance to centralized wastewater treatment plants. Therefore, they were constructed especially many in rural areas, where are small villages but not industries. Accordingly, plantless column tests were performed to investigate the possibility on using zeolite as a filter medium of constructed wetland for the wastewater treatment. $COD_{cr}$ removal efficiency was 94.63% at hydraulic load $314L/m^2{\cdot}d$ and filtering hight 100cm filled with a zeolite mixture. This zeolite mixture consisted of 1 : 1 by volume of a zeolite in the diameter range of 0.5 to 1mm to a zeolite in the diameter range of 1 to 3mm. According, hydraulic load $314L/m^2{\cdot}d$ was considered as optimal. Three zeolite mixture were used to determine the optimal mixing ratio by volume of a zeolite(A) in the diameter range of 0.5 to 1mm to a zeolite(B) in the diameter range of 1 to 3mm diameter. 1 : 3, 1 : 1 and only B in A to B by volume were tested at hydraulic load $314L/m^2{\cdot}d$ and filtering hight 100cm. $COD_{cr}$ removal efficiency was more than 89% at mixing ratios of 1 : 3 and 1 : 1 in A to B. Removal efficiency was lower at the column filled with only B. Removal efficiency was better at filter medium filled with mixing ratio 1 : 1 in A to B than with the other mixing ratios. Thus, it was found that the mixture of mixing ratio 1 : 1 in A to B was appropriate for filter medium of constructed wetland. Removal efficiency was higher in down-flow than in up-flow, and $COD_{cr}$ and BOD were removed best in 20cm filter height near feeding area.

  • PDF

강우시 도로유출수 수질특성 및 입경분포 (Water Quality and Particle Size Distributions of Road Runoff in Storm Event)

  • 이준호;조용진;방기웅
    • 대한환경공학회지
    • /
    • 제27권7호
    • /
    • pp.777-784
    • /
    • 2005
  • 도시지역은 불투수층 면적비율이 높아 작은 강우에도 초기유출(first flush)이 강하게 발생하고 유출되는 오염물질 농도도 높다. 도로유출수에는 미세입자물질, 중금속, 유기물질 성분을 다량 함유하고 있다. 도로유출수의 수질과 입자의 유출특성을 파악하고자 교통량이 비교적 많은 도로 2개 지점을 대상으로 총 6회의 강우시료를 채수하여 분석하였다. 2개 조사 지점에서 분석된 도로유출수 수질농도범위는 SS $45{\sim}2,396\;mg/L$, $COD_{Cr}\;40{\sim}931\;mg/L$, TKN $0.1{\sim}19.6\;mg/L$, TP $0.2{\sim}25.1\;mg/L$, Fe $0.33{\sim}8.15\;mg/L$, Cr $0.06{\sim}0.50\;mg/L$, Pb $0.06{\sim}0.97\;mg/L$, Cr $0.01{\sim}0.12\;mg/L$으로 조사되었다. 강우초기의 농도는 극단적으로 높은 특성을 나타내었다. 도로유출수 SS와 상관계수가 높은 수질항목으로는 $COD_{Cr}$, TP, Cu, Pb이고, 상관계수가 가장 낮은 항목으로는 TKN으로 분석되었다. 도로유출수의 입경을 분석한 결과 평균 f3경간의 범위는 $6.7{\sim}23.4\;{\mu}m$이고 90% 입경의 범위는 $36.2{\sim}105.2\;{\mu}m$로 분석되었다. 또한, 입경은 유출량에 비례적으로 증가하는 경향을 나타내었다. 균등계수를 분석한 결과 평균범위는 $6.4{\sim}10.2$로 입경 분포범위가 크게 나타났다.

유동상 담체를 이용한 Loop Reactor에서 유기물 및 질소, 인 제거 (The Removal of Organics, Nitrogen and Phosphorus in Loop Reactor Using Fluidized Media)

  • 선용호
    • KSBB Journal
    • /
    • 제24권4호
    • /
    • pp.353-360
    • /
    • 2009
  • 본 연구에서는 혐기조 및 무산소조, 호기조로 구성된 상향류식 고정상 담체 반응장치와 호기조로 고정상 담체 대신에 유동상 담체를 사용한 Loop Reactor로 이루어진 장치에서 생활하수를 이용하여 성능실험을 수행한 후 HRT에 따른 유기물 및 T-N, T-P 등 오염물질의 제거 특성을 비교 분석하였다. 두 반응기 모두 평균 BOD 제거율과 SS 제거율은 HRT가 증가함에 따라 증가하다가 HRT 16 h 이상에서는 일정한 수치를 나타내고 있으며 HRT 16 h에서 고정상 담체 반응기와 Loop Reactor의 평균 BOD 제거율은 각각 86.6%, 90.9%이었으며 평균 SS 제거율은 각각 78.0%, 88.2%로 Loop Reactor의 경우가 각각 4.3%, 10.2%의 더 높은 BOD와 SS 제거율을 나타내었다. 또한 평균 $COD_{Cr}$, 제거율 및 평균 $COD_{Mn}$ 제거율은 BOD와 SS 제거율과 마찬가지로 HRT가 증가함에 따라 증가하다가 HRT 16 h에서 일정한 수치를 나타내고 있으며 고정상 담체 반응기와 Loop Reactor의 평균 $COD_{Cr}$, 제거율은 각각 63.5%, 75.2%이었으며 평균 $COD_{Mn}$ 제거율은 각각 60.7%, 73.6%로 Loop Reactor의 경우가 11.7%, 12.9% 더 높은 제거율을 나타내었다. 반면에 평균 T-N 제거율 및 T-P 제거율은 두 반응기 모두 HRT가 증가함에 따라 제거율은 계속 증가하는 양상을 보여주고 있으며 HRT 16 h에서 Loop Reactor의 경우 평균 T-N 제거율 및 평균 T-P 제거율은 각각 33.6%, 54.5%로 고정상 담체 반응기보다 14.1%, 10.8%의 더 높은 제거율을 나타내었다. 이상의 결과에서 Loop Reactor가 성능이 훨씬 더 우수하였으며 최적 HRT는 16 h임을 알 수 있었다.

면섬유염색폐수의 공정별 폐수성상과 이온화가스에 의한 처리특성 (Composition of Cotton Textile Dyeing Process Wastewater and its Treatment Characteristics by Ionized Gas)

  • 임경은;정팔진;권지영;이은주
    • 한국물환경학회지
    • /
    • 제23권3호
    • /
    • pp.303-308
    • /
    • 2007
  • Three types dyeing wastewater (dark, medium, light color) discharged from cotton textile dyeing with reactive dye was collected at each step of process. Each process dying wastewater was analyzed and treated by ionized gas. The analysis focused on $COD_{Cr}$, SS and color. Bleaching & scouring process wastewater has the highest $COD_{Cr}$ value in the three type dyeing wastewater. SS shows the highest value at dyeing process wastewater in dark and medium color but light color has at finishing process wastewater. The result of process wastewater treatment by ionized gas was that the ionized gas was effective in $COD_{Cr}$ removing of bleaching & scouring process and finishing process wastewater but was not good at dyeing process wastewater. From that result it is estimated that the ionized gas could not work in opening the aromatic ring and react only in aliphatic component of the molecule. Because the surfactants contained in bleaching & scouring process and finishing process wastewater have only one aromatic ring in its molecular structure, in contrast with the reactive dye compounds consist of aromatic rings great part of its molecular structure. The color almost removed in 1.5 hrs reaction time but $COD_{Cr}$ removal effiency was only 30.7% through 3hrs in 1500 mL of total dyeing wastewater treated by 10 L/min ionized gas.

도로노면 유출수의 비점오염원 배출 특성(1): 기본 수질 항목 (Characteristics of Non-point Pollutants from the Road Runoff (1): Water Quality)

  • 박상우;오재일;최영화;서정우
    • 상하수도학회지
    • /
    • 제21권2호
    • /
    • pp.225-233
    • /
    • 2007
  • Road runoff water is one of the non-point sources (NPSs) of pollution negatively influencing drinking water source. Numerous road runoff NPS waters have been studied for over the last decade. However, the sources of pollution can be conditional, seasonal, or accidental. Therefore, measurement of pollutant loadings in different site is necessary to estimate the effect of road runoff water. The objective of this study was to examine the quality of road runoff water from a city bridge in Seoul, Korea. This study was conducted for two years to assess annual discharge pollution loads. In this study, key water quality parameters including chemical oxygen demand ($COD_{Cr}$), biochemcial oxygen demand ($BOD_5$), total nitrogen (T-N), total phosphorus (T-P), and suspended solid (SS) were measured at 18 different events. The results showed that typically the pollutant concentrations are higher at the beginning of each event and decrease afterwards. The first 20% of the volume of the runoff from each event is transporting 46% ($COD_{Cr}$), 48% ($BOD_5$), 50% (T-N), 34% (T-P), 30% (SS), respectively. The event mean concentrations (EMCs) were $COD_{Cr}$ (199 mg/L), $BOD_5$ (41.2 mg/L), T-N (7.97 mg/L), T-P (0.42 mg/L) and SS (113 mg/L). Although the results were consistent with the previous study (Barbosa and Hvitved-Jacobsen, 1999), $COD_{Cr}$, $BOD_5$, T-N exhibit a stronger first flush effect compared to the other contaminants.