Application of TOC Standards for Managing Refractory Organic Compounds in Industrial Wastewater (난분해성 유기물 관리를 위한 산업폐수 TOC 기준 적용방안 연구)

  • Choi, Ik-Won;Kim, Jae-Hoon;Im, Jong-Kwon;Park, Tae-Jin;Kim, Se-Young;Son, Dae-Hee;Huh, In-Ae;Rhew, Doug-Hee;Yu, Soon-Ju
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.1
    • /
    • pp.29-34
    • /
    • 2015
  • The aim of this study is to understand the limitation of organic pollutant indexes ($BOD_5$, $COD_{Mn}$, $COD_{Cr}$) and estimate to set the TOC standard by comparing oxidation rates of $BOD_5$, $COD_{Mn}$, $COD_{Cr}$ and TOC based on the 487 organic compounds and 11 effluents from industrial wastewater containing various and unknown organic compounds. The range of ratio of theoretical oxygen demand (ThOD) to theoretical organic carbon (TOCt) was 0.00~5.33 and average ratio of classes of organic compounds was 2.68~3.70. According to classes of organic compounds, the average ratio of $O_2/C$ was 1.2 (range : 1.02~1.39). The order of oxidation rate for 15 organic compounds was TOC (90.7%) > $COD_{Cr}$ (88.8%) > $BOD_5$ (54.4%) > $COD_{Mn}$ (30.8%) indicating the lower oxidation rate of $BOD_5$ and COD compared with TOC. The ranking for average oxidation rate was $COD_{Cr}$ > $COD_{Mn}$ > $BOD_5$ indicating that $BOD_5$, $COD_{Mn}$ could be underestimated comparing with ThOD of organic compounds in case of industrial wastewater containing high concentration of refractory organic compounds. Most of the relationships between organic pollutant indexes and TOC were higher than 0.9. The ratio of TOC to organic compound indexes decreased in the order : $COD_{Cr}$ (3.4) > $COD_{Mn}$ > (1.9) > $BOD_5$ (0.7).

Biological Treatment of Phenolic Industrial Wastewater by a Mixed Culture Immobilized on Ceramic Beads (세라믹담체를 이용한 페놀계 산업폐수의 생물학적 처리)

  • Oh, Hee-Mock;Ku, Young-Hwan;Ahn, Kuk-Hyun;Jang, Kam-Yong;Kho, Yung-Hee;Kwon, Gi-Seok;Yoon, Byung-Dae
    • Microbiology and Biotechnology Letters
    • /
    • v.23 no.6
    • /
    • pp.755-762
    • /
    • 1995
  • A phenolic resin industrial wastewater containing about 41,000 mg/l of phenol and 2,800 mg/l of formaldehyde was biologically treated by a mixed culture GE2 immobilized on ceramic beads. This study was carried out with three experimental groups : Control-only added the sludge of papermill wastewater ; GE2 treatment-added GE2 to Control ; Ceramic treatment-applied ceramic carrier to GE2 treatment. When the original wastewater was diluted 80 times with aerated tap-water, influent COD$_{Mn}$ WaS 1,140 mg/l and that of the effluent was in the range of 22-35 mg/l, which was not much different among the experimental groups. However, at 20-times dilution, influent COD$_{Mn}$ was 4,800 mg/l and the effluent COD$_{Mn}$ of Control, GE2 treatment and Ceramic treatment was 179, 128 and 94 mg/l, respectively. COD$_{Mn}$, removal efficiency by Ceramic treatment was the highest, at 98.0%. At this time, the effluent phenol concentration of Control, GE2 treatment and Ceramic treatment was 10.71, 7.93 and 5.60, respectively. As the dilution times decreased, the removal efficiency of COD$_{Mn}$ and phenol did not change much, but COD$_{Mn}$ and phenol concentration of the effluent increased. Consequently, it is likely that the phenolic industrial wastewater containing phenol and formaldehyde can be biologically treated using a GE2 and ceramic carrier and that at 40-times dilution, the effluent completely meets the effluent standards for industrial wastewater treatment plant.

  • PDF

A study on comparison and decomposition of organic matter in Nakdong river basin (낙동강 수계 유기물 비교 및 분해에 관한 연구)

  • Han, Gyuseong;Lee, Jaesoon;Kwon, Bomin;Choi, Kwangsoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.487-487
    • /
    • 2018
  • 본 연구에서는 2017년 5월부터 12월까지 주단위로 낙동강 수계 5개 보 구간(칠곡보~창녕함안보)에서 본류와 유입지천의 유기물(BOD, $COD_{Mn}$, TOC) 분석 및 상관관계 조사하였으며, 강정고령보~창녕함안보의 대표지점에 대해서는 용존유기물(DOC)의 분해특성을 조사하였다. 본류의 유기물 농도는 BOD $2.7mgO_2/L$($2.3{\sim}3.1mgO_2/L$), $COD_{Mn}$ $5.6mgO_2/L$($5.0{\sim}6.2mgO_2/L$), TOC 4.7 mgC/L($4.2{\sim}5.2mgO_2/L$), 유입지천은 BOD $3.4mgO_2/L$($1.1{\sim}5.6mgO_2/L$), $COD_{Mn}$ $7.1mgO_2/L$($2.5{\sim}10.9mgO_2/L$), TOC $5.7mgO_2/L$(2.3~8.7 mgC/L)로 각각 나타났다. 유기물간 상관성 분석결과 본류의 BOD와 COD, TOC 상관계수(r)은 각각 0.97, 0.98, COD와 TOC는 0.91, 유입지천의 BOD와 COD, TOC는 각각 0.81, 076, COD와 TOC는 0.99로 나타났다. 본류 구간에서 탄소로 환산된 BOD-C/TOC 산화율은 21.5%(20.4~22.5%), COD-C/TOC 45.7%(44.3~48.0%), 유입지천의 BOD-C/TOC 산화율은 23.6%(13.1~31.0%), COD-C/TOC 48.0%(41.3~53.3%)로 각각 나타났다. 강정고령보~창녕함안보 대표지점의 DOC 분해특성은 DOC 중 R-DOC가 86.9%(74.5~94.3%), L-DOC 13.0%(5.7~25.5%)로 나타났다. L-DOC의 분해속도(k)는 0.21 /day(0.11~0.38 /day)로 계산되었으며, 보별 평균 분해속도는 합천창녕보(0.25 /day) > 강정고령보(0.22 /day) > 창녕함안보(0.21 /day) > 달성보(0.18 /day)순으로 나타났다. 유기물 농도는 본류에서는 하류로 갈수록 증가하는 경향을 보였으며, 유입지천은 지점별로 다양하게 나타났다. 유기물간 상관성은 유입지천보다 본류구간이 상관계수가 높게 나타났다. TOC에 대한 BOD와 $COD_{Mn}$산화율은 본류구간 보다 유입지천에서 큰 변동을 보였으며, 실제 유기물 총량 대비 BOD와 $COD_{Mn}$은 각각 77.0%, 52.7% 낮게 나타났다. DOC 중 난분해성 유기물이 대부분을 차지하였으며, 타 보 대비 달성보 내에 난분해성 유기물이 높은 것으로 나타났다.

  • PDF

NPS runoff reduction analysis in accordance with the slope of the tillage method (경운방법의 경사도에 따른 비점오염원 유출 저감 효과 분석)

  • Jeon, Je Hong;Won, Chul Hee;Moon, Sang Gi;Lee, Su In;Choi, Jung Dae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.425-425
    • /
    • 2015
  • 본 연구는 밭에서 발생하는 비점오염원의 저감 효과를 분석하기 위하여 최적관리기법(BMPs) 중 경운방법과 침투짚단을 하여 효과를 분석하고자 하였다. 시험포 1개의 면적은 $150m^2$ (폭 5 m, 경사장 30 m)이며, 모두 사질토의 특성을 가진 토양이다. 시험포는 총 8개(경사도 3% 4개, 8% 4개)로 각각 무경운 시험포 2개와 경운 시험포 1개 그리고 침투 짚단을 설치한 경운 시험포 1개로 경사도와 영농방법을 다르게 조성하였다. 실험의 오차를 줄이기 위하여 강우지속시간과 강우량 그리고 강우강도가 일정한 인공강우 실험을 수행하였으며, 실험시 바람에 의한 강우량의 오차를 줄이기 위해 날씨가 맑은 날에 실시하였다. 또한, 선행무강우일수 7일로 유지하여 토양의 함수비를 동일한 조건이 되도록 하였다. 총 3회의 인공강우실험에서 강우강도는 30 mm/hr 이였으며, 강우로 인해 발생한 유출수는 수위를 측정한 뒤, 수위-유량곡선식을 이용하여 유량으로 환산하였으며, 이때 수질시료를 채취하였다. 채취된 수질시료는 $BOD_5$, $COD_{Cr}$, $COD_{Mn}$, TN, TP, DOC 등의 6개 항목을 분석하였다. 연구결과 경사도 3%의 침투짚단 시험포에서 오염부하는 경운 시험포 대비 $BOD_5$는 25.4%, $COD_{Cr}$은 20.5%, $COD_{Mn}$은 2.1%, DOC는 40.8%, 영양염류인 TN과 TP는 각각 23%와 8.7%가 저감되는 것으로 나타났다. 또한 경사도 3%의 무경운 시험포에서 오염부하는 경운 시험포 대비 $BOD_5$는 57.5%, $COD_{Cr}$은 59.8%, $COD_{Mn}$은 65%, TN과 TP는 65.4%와 75%로 저감되었다. 그리고 경사도 8%에서 경운 시험포대비 침투짚단 시험포의 오염부하는 $BOD_5$ 19.6%, $COD_{Cr}$$COD_{Mn}$은 각각 7.8%와 10% 그리고 영양염류인 TN은 15.5%, TP는 11.2%가 저감되는 것으로 나타났다. 경사도 8%에서 무경운 시험포에서는 경운 시험포 대비 $BOD_5$ 70.9%, $COD_{Cr}$$COD_{Mn}$은 각각 74.9%와 81.3% 그리고 영양염류인 TN은 70.2%, TP는 70.1%가 저감된 것으로 나타났다. 본 연구결과와 같이 경운을 하는 관행방법에 비해 토양의 침투능이 유지할 수 있는 무경운 방법이나 침투짚단을 활용하는 방법이 밭에서 발생하는 비점오염원을 저감할 수 있는 것으로 나타났다. 그러나, 본 연구의 결과는 3번의 인공강우 실험을 통해 분석된 결과로써 추가적인 연구를 통해 다양한 경사도와 영농방법에 따른 비점오염물질의 저감효과를 분석해야 할 것으로 보여진다.

  • PDF

Pre-treatment of River Water Using Biological Aerated Filtration (호기성 생물여과 공정을 이용한 하천수 전처리)

  • Choi, Dong-Ho;Choi, Hyung-Joo;Bae, Woo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.3
    • /
    • pp.276-285
    • /
    • 2006
  • When polluted stream water was treated with biological aerated filter(BAF) in pilot plant, all operation with 90, 60, 45 and 30 min of EBCT at fixed $0.1m^3air/m^2min$ of aeration showed 80% or higher treatment efficiency of particle materials(SS, turbidity and Chl.-a) and 85% or higher efficiency of ammonia nitrogen removal. It was thought that, in case of BOD, biological stability may sufficiently be assured with BAF because grade III or IV inflow water was changed to grade I for outflow water. In case of $COD_{Mn}$, about 60% of removal efficiency was found. When the mechanism of the result was investigated, about 30% of COD materials was produced by algae clogged in the reactor. There was almost no biological decomposition because specific substrate utilization rate of algogenic organic materials were $0.0245mg{\cdot}COD_{Mn}/mg{\cdot}VSS{\cdot}day$, thus partial backwashing(washing the media in 1 m upper of the reactor once a day) was required. It is thought that elevation of removal rate about 10% of $COD_{Mn}$ and 5.5% of $BOD_5$ could be obtained with partial backwashing resulting in assurance of biologically more stable raw water and that saving backwashing water may be significant.

Evaluation of Nanjido Landfill Site Stabilization by Leachate Component (침출수 성분에 따른 난지도 매립지의 안정화 평가)

  • Lee Je-Seung;Suh Mi-Yeon;Kim Hyun-Kook;Lee Sung-Joo;Kim Kwang-Jin;Shin Jung-Sik
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.3 s.53
    • /
    • pp.13-21
    • /
    • 2004
  • This study was focused on the evaluation of Nanjido landfill site by leachate analysis. Several parameters, for example pH, BOD, $COD_{Mn},\;COD_{Cr}$, SS, TP, $NH_3-N$, Color, were selected as major leachate quality parameters. $BOD/COD_{Cr}$. was used to estimate the biodegradable portion in organic matter. Samples were collected at the leachate storage wells and leachate treatment facility inflow in each quarter of 2003. The results were as follows : 1. Inflow quality of treatment plant in 2003 was analysed as $pH\;7.3\~8.0,\;BOD\;12.4\~30.0mg/L,\;COD_{Mn}\;101.2\~130.3mg/L,\;COD_{Cr}\;122.5\~238.0mg/L,\;SS\;16.1\~115.3mg/L$, $T-P\;0.27\~0.80mg/L,\;NH_3-N\;208.0\~~354.0mg/L$, Color $110.3\~129.0$ unit. 2. $BOD/COD_{Cr}$ of inflow ranged between $0.07\~0.16$ indicating that the landfill had the properties of old-fill and organic portion in leachate was mostly persistent organic matter. 3. Though concentrations of BOD, COD, $NH_3-N$, Color in leachate storage wells were mostly higher in first landfill than in second landfill, $BOD/COD_{Cr}$ ranging from 0.03 to 0.20, showed reversely. 4. Correlation coefficient$(R^2)$ between color and other parameters related to organic matter showed mostly above 0.7 and especially highest value with $COD_{Mn}$ of 0.7985.

Study on Pollutant Characteristics of Tunnel Cleaning Wastewater and Removal Characteristics of the Pollutants via Settling and Adsorption (터널 세척 폐수 특성 및 분리.흡착 방식에 따른 오염물질 저감 연구)

  • Park, Sang-Woo;Choi, Young-Hwa;Oh, Je-Ill
    • International Journal of Highway Engineering
    • /
    • v.9 no.3
    • /
    • pp.75-82
    • /
    • 2007
  • Washed wastewater generated from the intermittent cleaning process of the three tunnel sites located in the Seoul area showed high concentrations of SS, $COD_{Cr}$, T-N, $NH_3-N$, $NO_3-N$, Zn, Cu, Cr(+6), Mn, Mg, Phenol, $CN^-$ and E-Coli based on the water quality analysis. These characteristics of the deteriorative wastewater depend on the sampling method, cleaning frequency, released amount of washing water, inner material of tunnel wall, traffic volume, and type of drainage systems. Gravitational separation experiment of SS with collected tunnel wastewater showed considerable removal of pollutants such as 80% of $COD_{Cr}$, 30% of T-N and 90% of T-P simultaneously. GAC isotherm test was conducted to remove dissolved portion of the pollutants, and resulted in high removal efficiencies above 80% of $COD_{Cr}$, T-N, Zn, Cu, Mn, Phenol, CN in the experimental condition of GAC dosage of $50g/1/{\ell}$.

  • PDF

Studies on the Effect of Water Quality Parameters on Total Coliform Concentrations in Sewage Effluents (하수방류수의 대장균군 발생에 영향을 미치는 수질인자에 관한 연구)

  • Beck, Young-Seog;Sohn, Jin-Sik
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.166-171
    • /
    • 2006
  • The objectives of the present paper were to investigate the concentration of total coliform in wastewater effluents and the effect of water chemical and physical characters in it. The most correlated parameter with total coliform was COD. It means that the wastewater treatment efficient effects on total coliform concentration. And we developed predictive model for the total coliform concentration. The estimated parameters for model were COD, temperature, nitrite, chloride, Mn and regression model equation was determined; log (Total Coli.) = 1.861+0.065[COD]+0.038[temperature]-0.0004[$Cl^-$]+3.697[Mn]-0.32 [$NO_2-N$] The developed model provided very strong correlation ($R^2:0.82$) between total coliform and regression equation. The parameters having high sensitivity were COD and temperature. So the study indicated that if the temperature and COD of wastewater effluent were known, we would estimate the concentration of total coliform and decide the most effective usage of chlorine.

Optimal Conditions for Chemical Coagulation of Dyeing-Complex Wastewater (종합염색폐수의 최적 화학응집조건)

  • 류원률;이호경;남범식;이영호;최장승;조무환
    • Textile Coloration and Finishing
    • /
    • v.12 no.2
    • /
    • pp.96-102
    • /
    • 2000
  • For the effective treatment of dyeing-complex wastewater, the most effective chemical coagulation method was studied. For the chemical coagulation of dyeing-complex wastewater, polyferric sulfate, $4Al_2(SO_4)_3$, PAC, ferrous sulfate, ferric sulfate, $FeCl_2$ and lime were used. It was investigated that polyferric sulfate was the most efficient coagulant. The optimal conditions and results for polyferric sulfate include the followings. When initial $COD_{Mn}$ concentration was 600mg/L, the optimal initial pH, dosage of coagulant, dosage of lime and PAA for $COD_{Mn}$ removal efficiency were 5, 1,200mg/L, 500mg/L and lmg/L, respectively. The optimal dosage of polyferric sulfate was increased proportionally to the influent $COD_{Mn}$ concentration.

  • PDF

형산강 하류의 점오염원 유입이 본류수질에 미치는 영향

  • Lee, Chang-Su;Gu, Bong-Heon
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2006.11a
    • /
    • pp.221-224
    • /
    • 2006
  • 각각의 유입오염원에 의한 오염가중은 연일지구 무처리 방류수에 의해 $BOD_5$, $COD_{Mn}$, T-N T-P가 각각 17.40%, 12.36%, 7.52%, 29.90%증가 한다. 효자지곡 지구 오염물질유입으로 인한 오염가중은 $BOD_5$, $COD_{Mn}$, T-N T-P가 각각 7.99%, 6.82%, 12.60%, 29.55%증가한다. 하수처리장 방류수의 오염물질유입으로 인한 오염가중은 $BOD_5$, $COD_{Mn}$, T-N T-P가 30.65%, 14.61% 44.75%, 67.43% 증가할 것으로 예측된다. 겨울철 형산강 본류의 유량감소로 인해 오염물질의 농축량이 증가한다. 이에 겨울철 및 강우량이 적은 시기에 적조 발생빈도가 높아지는 것으로 판단된다.

  • PDF