• Title/Summary/Keyword: $COD_{Cr}$

Search Result 332, Processing Time 0.026 seconds

Characteristics of sewage Treatment by using Indirectly Aerated Submerged Biofilter(INSUB) (간접폭기형 침적생물여과장치(INSUB)를 이용한 오수처리 특성)

  • Huh, Mock;Kang, Jin-Yuong;Kim, Gwang-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.2
    • /
    • pp.125-131
    • /
    • 2003
  • This study was carried out to develop INSUB(Indirected Aerated Submerged Biofilter) which can remove organics, nitrogen and phosphorus with an advanced treatment system. The results were as followed in laboratory model experiment. As for treatment of sewage, when economical efficiency was considered in practice, the highest removal efficiency was at 18hr of HRT, 1.017m/hr of superficial velocity and 40% of media packing ratio. Each removal efficiency for $COD_{cr}$, $COD_{Mn}$, $BOD_5$, T-N, and T-P was 90.6, 85.3, 95.0, 52.3 and 56.8%. To remove the nitrogen and phosphorus With high efficiency, first of all, denitrification have to be completed, then uptake of phosphorus have to completed. Therefor, mixture of anoxic and aerobic reactor was necessary for the high removal efficiency of nitrogen and phosphorus in INSUB.

  • PDF

A Treatment Efficiency of Wastewater by using Sym-Bio Process and Dissolved Ozone flotation Process for Water Reuse (하수처리수 재이용을 위하여 Sym-bio공정과 용존 오존 부상공정을 이용한 하수처리의 효율 분석)

  • Park, Changyu;Park, Jaehan;Lee, Kyunghee;Ahn, Yoonhee;Ko, Kwangbaik;Jung, Hyuncheol
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.1
    • /
    • pp.86-90
    • /
    • 2008
  • Water reuse of effluent is limited, due to bacteria and chromaticity or turbidity which may result in low perception of water quality. Consequently, this study showed a method in the reuse of treated wastewater by a diversified treatment method, with separation of centralized reformation of aeration tank into pre-treatment with minimum installation of facilities, and post-treatment, applying advanced oxidation treatment. A pilot plant experiment was performed using Sym-Bio process adopting an NADH Sensor without modification of the exiting aeration tank. The Dissolved Ozone Flotation process, which is an advanced oxidation process, to treat the remaining organics, nutrients, chromaticity, turbidity and bacteria. As a result in the Sym-Bio process, the biological treatment, even on the condition of single stage reaction tank, the treatment efficiencies of BOD, $COD_{Mn}$, $COD_{Cr}$, SS and T-N were 96.6%, 84.6%, 88.25%, 95.1% and 71.0%, respectively, while that for T-P was 25.0%, which required further treatment. In the Dissolved Ozone Flotation process, the advanced oxidation treatment, the treatment efficiencies of BOD, $COD_{Mn}$, $COD_{Cr}$, SS, T-N, T-P, chromaticity, turbidity, bacteria, coliforms were 78.9%, 34.6%, 28.7%, 48.0%, 70.4%, 82.4%, 84.0%, 74.5%, 99.8% and 99.4%, respectively.

Assessment of Characteristics and Field Applicability with TPA By-Product as Alternative External Carbon Source (대체 외부탄소원으로서의 TPA 생산부산물 특성 및 현장적용성 평가)

  • Jung, In-Chul;Jun, Sung-Gyu;Sung, Nak-Chang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.5
    • /
    • pp.480-486
    • /
    • 2006
  • On account of exchanging main process from chemical precipitation for MLE(Modified Ludzark-Ettinger), an external carbon source was required for supplementation of carbon source shortage that was needed biological denitrification in the S sewage treatment plant(S-STP). In this study, NUR(nitrate uptake rate), OUR(oxygen uptake rate) test and a field application test was conducted for the applicability assessment of Terephtalic acid(TPA) by-product contained about 4.7% acetate as alternative external carbon source. As the results, TPA by-product shows more rapid acclimation than methanol, 8.24 mg ${NO_3}^--N/g$ VSS/hr specific denitrification rate, 3.70 g $COD_{Cr}/g\;NO_3$ C/N ratio and 99.4% readily biodegradable COD contents. In the results of field application, the nutrient removal efficiency was high and effluent T-N concentration is 8.2 mg/L. It is concluded that TPA by-product is the proper alternative external carbon source.

Horizontal Flow Zeolite-Filled Reed Bed with Intermittent Feeding for Sewage Treatment (수평 흐름 제올라이트 갈대 여과상에 의한 생활하수 처리)

  • Seo Jeoung-Yoon;Kim Ean-Ho
    • KSBB Journal
    • /
    • v.21 no.1 s.96
    • /
    • pp.28-33
    • /
    • 2006
  • A sewage was treated using a horizontal flow zeolite-filled reed bed. The sewage from the student dormitory of Changwon National University was fed into the reed bed for 10 minutes every 6 hours at the hydraulic load of $314L/m^2$ day. The filtering height of the reed bed was 100 cm and the zeolite mixture was filled in the reed bed. The mixture consisted of the same volume of two types of zeolite : $0.5{\sim}1mm$ and $1{\sim}3mm$ in diameter. Annual average removal efficiency was SS $88.5%,\;COD_{cr},\;86.1%,\;COD_{Mn}\;81.0%,\;T-N\;48.6%,\;NH_4^+-N\;97.1%$ and T-P 42.8%. T-N of effluent was mostly $NO_3^--N$ and the concentration of $NO_2^--N$ in effluent was lower than 0.1 mg/L. All removal efficiencies did not show a remarkable seasonal change.

Analysis of Runoff Characteristics of NPS Pollution in different Slope from Upland field (경사도가 다른 고랭지 밭의 비점오염물질 유출특성 분석)

  • Lee, Su-In;Shin, Jae-Young;Shin, Min-Hwan;Choi, Yong-Hun;Choi, Joong-Dae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.906-906
    • /
    • 2012
  • 밭에서 발생하는 비점오염물질은 강우량, 강우강도, 경사도, 토양, 시비량 등에 영향을 받는다. 따라서 효율적인 비점오염물질의 관리를 위해서는 영향인자에 대한 자세한 분석이 선행되어야 한다. 이에 본 연구에서는 강원도 평창군 대관령면의 경사도가 다른 고랭지 밭 두 지점을 선정하여 비점오염물질의 유출특성을 파악하고, 향후 비점오염원의 효율적인 관리를 위한 기초자료를 제공하고자 하였다. 연구기간은 2011년 4월부터 11월까지 유출이 발생한 8회의 강우사상에 대해 모니터링을 수행하였다. 연구결과 경사도 4.9% 밭에서의 유출율은 0.05~0.48이었으며, 16.8% 경사에서는 0.31~0.57로 나타났다. 유량과 채취된 수질 시료를 이용해 EMC를 산정한 결과 경사도 4.9%인 밭에서는 SS 762.1~2422.7 mg/L $BOD_5$ 4.5~14.9 mg/L, $COD_{Cr}$ 16.1~62.0 mg/L, $COD_{Mn}$ 7.5~43.2 mg/L, TN 9.602~21.021 mg/L, TP 2.544~6.763 mg/L의 범위로 나타났다. 반면 16.8%의 경사밭에서는 SS 116.0~2015.5 mg/L $BOD_5$ 6.0~9.5 mg/L, $COD_{Cr}$ 21.9~75.4 mg/L, $COD_{Mn}$ 4.3~33.1 mg/L, TN 10.937~46.295mg/L, TP 2.611~11.197 mg/L의 범위로 나타났다. 두 지점의 유출률과 EMC를 비교한 결과, 경사가 증가함에 따라 유출율이 증가하는 것으로 나타났으며, SS를 제외한 모든 수질항목의 EMC가 증가한 것으로 나타났다. SS의 경우 경사가 큰 고랭지 밭에서 낮은 값을 보였는데, 이는 16.8%의 경사밭에서 등고선 방향으로 경운을 하여 흙 입자의 유실이 적었기 때문인 것으로 판단된다. 본 연구의 결과와 같이 밭에서 발생하는 비점오염물질의 유출특성은 강우조건(강우강도, 선행무강우일수), 시비량, 토양, 지표의 피복상태 등에 따라 다르기 때문에 장기적인 모니터링을 통해 기초자료를 축적하는 것이 중요하다고 판단된다.

  • PDF

Conversion of CODMn into TOC and Refractory Organic Matter Concentrations for Treated Sewage using Regression Equations (회귀식을 사용한 하수처리장 방류수 CODMn 농도의 총 유기탄소 및 난분해성 물질 농도 전환)

  • Lee, Tae-Hwan;Lee, Bomi;Hur, Jin;Jung, Myung-Sook;Kang, Tae-Gu
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.969-975
    • /
    • 2010
  • Estimating the organic matter loadings from individual treated sewage has become important for establishment of effective management strategies to control refractory organic matter (R-OM) in watersheds. For this study, regression equations were constructed using treated sewage data to convert the chemical oxygen demand (COD) concentrations, which are mostly available from open database, into total organic carbon (TOC) and R-OM concentrations. Effluent samples were collected from five major sewage treatment plants (STPs) located upstream of the lake Paldang. Variations in the OM concentrations were not associated with either the location of the STP or the sampling season. The effluent investigated were characterized by higher ratio of R-OM with respect to biodegradable organic matter (B-OM) and higher presence of dissolved organic matters (DOM) versus particulate organic matter (POM). Compared to $COD_{Mn}$, $COD_{Cr}$ exhibited higher oxidation efficiencies and greater variations in the concentrations. The concentrations of $COD_{Mn}$ were positively correlated with dissolved organic carbon (DOC), total organic carbon (TOC), and R-OM concentrations. There was nearly no seasonal and annual variation in the regression equations between $COD_{Mn}$ and TOC or R-OM concentrations. The constructed regression equations for TOC and R-OM were $0.650({\pm}0.071){\times}COD_{Mn}+1.426({\pm}0.575)$ and $0.340({\pm}0.083){\times}COD_{Mn}+2.054({\pm}0.670)$, respectively. The established equations are expected to contribute to estimating OM loadings from the STPs into the lake Paldang and also to compensating for the deficiency of the data for effluent OM concentrations in STP.

고효율 자외선/광촉매 시스템을 이용한 고농도 유기성 폐수처리

  • Jeong, Hyo-Gi;Kim, Jung-Gon;Kim, Si-Uk
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.272-276
    • /
    • 2005
  • Food wastewater derived from three-stages methane fermentation system showed high concentrations of sCOD, T-N and $NH_{3}-N$. To treat the organic wastewater, the optimal operating conditions for high efficiency $UV/TiO_{2}$ photocotalytic system have been investigated. In the first process, wastewater was pre-treated with $FeCl_{3}. The optimum pH and concentration for coagulation were 4.0 and 2000 mg/L, respectively. Through this process, 52.6% of $COD_{cr}$ was removed. The second process was $UV/TiO_{2}$ photocatalytic reaction. The optimum conditions for the operation of $UV/TiO_{2}$ photocatalytic system developed in this lab have been studied. In this process, CODcr was removed from 2890 to 184 mg/L and T-N was removed from 2496 to 914 for 24 hours, respectively.

  • PDF

Evaluation of Affecting Factors for Refractory Organics Accumulated in the Lakes (호소의 난분해 물질 축적 영향요인의 평가)

  • Kim, Sungwon;Kim, Geonha;Choi, Euiso
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.720-726
    • /
    • 2006
  • Long-term monitoring results of water qualities at major lakes in Korea showed COD (chemical oxygen demand) concentrations have been increasing while BOD (biochemical oxygen demand) concentrations have been decreasing during last decades. This was mainly due to refractory organic matters have been accumulated in the water body. In this study, the possible causes of COD concentration increase were evaluated. From the statistics, it can be understood that potent pollutant sources including fertilizer consumption, population, livestock, and carbon uptake have increased. Leaching tests were carried out with soils and biomasses sampled at agricultural-forestry area. From the leaching experiments, leachate qualities as a ratio of $COD_{Cr}/BOD$ were in the range of 2.5-5.0, implying that NOM (natural organic matters) discharged from the forestry area was mainly responsible for the COD accumulation. It can be understood from this research that diffuse pollutants from forestry areas should be controlled properly to reduce COD accumulation in the lakes.

The Treatment of Night Soil using Bacillus sp. (Bacillus sp.를 이용한 분뇨처리)

  • 염혜경;이은숙;이병헌;이민규;정일호;김중균
    • Journal of Life Science
    • /
    • v.12 no.6
    • /
    • pp.700-707
    • /
    • 2002
  • To study the characteristics of organic and nutrient removal by Bacillus species at high COD concentration of influent, three lab-scale batch reactors(R1, R2, R3), each of which has different substrate composition, were operated. More than 95% of $NH_4^+$-N and $COD_{cr}$, concentrations were removed under an aerobic condition, and their removal efficiencies were found to be 22.6 and 90.5%(R1), 23.9 and 65.8%(R2), 30.2 and 86.4%(R3), respectively. The removal efficiency of $NH_4^+$-N was high when an enough amount of $NO_3^{-}$-N was supplied, and that of $COD_{cr}$. was low when a high concentration of initial $NO_2^{-}$-N was added. The amount of carbon utilized in denitrification was a little. In all reactors,$NO_3^{-}$-N was removed under an anoxic condition, but in the R3 reactor, 10% of $NO_3^{-}$-N could be removed even undo, an aerobic condition. The removal efficiencies of TN and TP were 41.8 and 49.5%(R1), 40.1 and 35.8%(R2), 47.0 and 57.6%(R3), respectively. Alkalinities destructed under an aerobic condition for each reactor were 4.96, 5.41 and 3.93 mg/L (as $CaCO_3$) per each gram of $NH_4^+$-N oxidized, respectively, while 3.06, 3.17 and 2.60 mg/L (as $CaCO_3$) of alkalinities were produced for each gram of ,$NO_3^{-}$-N reduced to $N_2$. The SOUR were found to be 38.5, 52.7 and 42.0 mg $O_2$/g MLSS/hr, which indicated that Bacillus sp. had a higher cell activity than activated sludge. The OLR and sludge production were estimated to be 0.69 and 0.28(Rl), 0.77 and 0.20(R2), 0.61 kg COD/$m^3$/day and 0.25 kg MLSS/kg COD(R3), respectively. From the N-balance, the highest percentage(40.9%) of nitrogen lost to $N_2$ was obtained in the R3 reactor. From all the results, the possibility of aerobic denitrification Bacillus sp. has been shown and the B3 process seemed to have two advantages: a little amount of carbon was required in denitrification and not much amount of alkalinity was destructed under an aerobic condition.

Improvement of River Water Quality By Combined Treatment of Sand Filtration and Ozonation(1) - Focusing on Reduction of BOD, COD, SS and Color (모래여과 및 오존처리에 의한 하천수 수질개선 효과 연구(1) - BOD, COD, SS 및 색도 제거 경향 고찰)

  • Choi, Changhee;NamKung, Kyucheol;Youn, Jongwoo;Lee, Chaeyoung
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.6
    • /
    • pp.813-821
    • /
    • 2011
  • While various aspects affect river water quality, reduction of water flow rate during dry seasons is one of the most significant factors causing severe water pollution in river water environment. The aim of this study is to investigate the feasibility of applying a physicochemical method (sand filtration + ozonation) for improving river water quality within a short period. The parameters analyzed and assessed were $COD_{cr}$, BOD, SS and color. The source river water had a severe pollution level showing COD 8.8~17.2 mg/L (ave. 11.9 mg/L), BOD 4.8~13.3 mg/L (ave. 8.3 mg/L), SS 9.0~22.1 mg/L (ave. 12.8 mg/L) and color 34.4~77.1 degree (ave. 56.5 degree) during the experimental periods. The variation trends showed a relatively low correlation between BOD and COD and between color and COD, while SS showed very low correlation with other parameters. The combined process of sand filtration and ozonation showed averaged removal efficiency of COD 37.2%, BOD 48.4%, SS 60.1% and colority 45.1%, respectively. The marked change of BOD level from 8.3 mg/L to 4.3 mg/L under the experimental conditions in this study implied the improvement of class V to class III set by the river water quality standard in Korea.