• Title/Summary/Keyword: $C^{*}$-Integral

Search Result 658, Processing Time 0.022 seconds

A Simulation of Temperature Control of Greenhouse with Hot-Water Heating System (온수난방시스템 온실의 온도제어 시뮬레이션)

  • 정태상;하종규;민영봉
    • Journal of Bio-Environment Control
    • /
    • v.8 no.3
    • /
    • pp.152-163
    • /
    • 1999
  • It is required to analyze the controlled response of air temperature in greenhouse according to control techniques for precise control. In this study, a mathematical model was established for air heating of greenhouse with hot-water heating system The parameters of the model were decided by regression analysis using reference data measured at the greenhouse being heated In the simulation for the digital control of air temperature in the greenhouse, the mathematical model to evaluate the control performances was used. Tested control methods were ON-OFF contpol, p control, rl control and PID control. The mathematical model represented by inside air temperature ( T$_{i}$), hot-water temperature (T$_{w}$) in heating pipe and outside air temperature (T$_{o}$) was expressed as a following discrete time equation ; T$_{i}$($textsc{k}$+1)= 0.851.T$_{i}$($textsc{k}$)+0.055.T$_{w}$($textsc{k}$)+0.094.T$_{o}$($textsc{k}$) Control simulations for various control methods showed the settling time, the overshoot and the steady state nor as follows; infinite time, 3.5$0^{\circ}C$, 3.5$0^{\circ}C$ for ON-OFF control : 30min 2.37$^{\circ}C$, 0.51$^{\circ}C$ for P control; 21min, 0.0$0^{\circ}C$, 0.23$^{\circ}C$ for PI control; 18min 0.0$0^{\circ}C$, 0.23$^{\circ}C$ for PID control, respectively. PI and PID controls appeared to be optimal control methods. There was no effect of differential gain on the heating process but much effect of integral gain on it.on it.

  • PDF

Jin-Yuan Mathematics and Quanzhen Taoism (금원수학여전진도(金元数学与全真道))

  • Guo, Shuchun
    • Journal for History of Mathematics
    • /
    • v.29 no.6
    • /
    • pp.325-333
    • /
    • 2016
  • Chinese Mathematics during the period of Jin (1115-1234) and Yuan (1271-1368) is an integral part of the high achievements of traditional mathematics during the Song (962-1279) and Yuan dynasties, which is another peak in the history of Chinese mathematics, following the footsteps of the high accomplishments during the Warring States period (475-221 BCE), the Western Han (206 BCE-24 ADE), Three Kingdoms (220-280 AD), Jin dynasty (265-420 AD), and Southern and Northern Dynasties (420-589 AD). During the Jin-Yuan period, Quanzhen Taoism was a dominating branch in Taoism. It offered certain political protection and religious comforts to many during troubled times; it also provided a relatively stable environment for intellectual development. Li Ye (1192-1279), Zhu Shijie (fl. late 13th C to early 14th C) and Zhao Youqin (fl. late 13th C to early 14th C), the major actors and contributors to the Jin-Yuan Mathematics achievements, were either heavily influenced by the philosophy of Quanzhen Taoism, or being its followers. In certain Taoist Classics, Li Ye read the records of the relations of a circle and nine right triangles which has been known as Dongyuan jiurong 洞渊九容 of Quanzhen Taoism. These relations made significant contributions in the study of the circles inscribed in a right triangle, the reasoning of which directly led to the birth of the Method of Celestial Elements (Tianyuan shu 天元术), which further developed into the Method of Two Elements (Eryuan shu ⼆元术), the Method of Three Elements (Sanyuan shu 三元术) and the Method of Four Elements (Siyuan shu 四元术).

Comparative Analysis of the Complete Genome of Lactobacillus plantarum GB-LP2 and Potential Candidate Genes for Host Immune System Enhancement

  • Kwak, Woori;Kim, Kwondo;Lee, Chul;Lee, Chanho;Kang, Jungsun;Cho, Kyungjin;Yoon, Sook Hee;Kang, Dae-Kyung;Kim, Heebal;Heo, Jaeyoung;Cho, Seoae
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.4
    • /
    • pp.684-692
    • /
    • 2016
  • Acute respiratory virus infectious diseases are a growing health problem, particularly among children and the elderly. Much effort has been made to develop probiotics that prevent influenza virus infections by enhancing innate immunity in the respiratory tract until vaccines are available. Lactobacillus plantarum GB-LP2, isolated from a traditional Korean fermented vegetable, has exhibited preventive effects on influenza virus infection in mice. To identify the molecular basis of this strain, we conducted a whole-genome assembly study. The single circular DNA chromosome of 3,284,304 bp was completely assembled and 3,250 protein-encoding genes were predicted. Evolutionarily accelerated genes related to the phenotypic trait of anti-infective activities for influenza virus were identified. These genes encode three integral membrane proteins, a teichoic acid export ATP-binding protein and a glucosamine - fructose-6-phosphate aminotransferase involved in host innate immunity, the nonspecific DNA-binding protein Dps, which protects bacteria from oxidative damage, and the response regulator of the three-component quorum-sensing regulatory system, which is related to the capacity of adhesion to the surface of the respiratory tract and competition with pathogens. This is the first study to identify the genetic backgrounds of the antiviral activity in L. plantarum strains. These findings provide insight into the anti-infective activities of L. plantarum and the development of preventive probiotics.

A Simulation Method of PID Tuning with Process Modeling in Operating Nuclear Power Plants (가동원전에서 공정모델링을 통한 PID 튜닝 시뮬레이션 방법)

  • Min, Moon-Gi;Jung, Chang-Gyu;Lee, Kwang-Hyun;Lee, Jae-Ki;Kim, Hee-Je
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.290-294
    • /
    • 2014
  • PID(Proportional, Integral, Derivative) controller is the most popular process controllers in nuclear power plants. The optimized parameter setting of the process controller contributes to the stable operation and the efficiency of the operating nuclear power plants. PID parameter setting is tuned when new process control systems are installed or current process control systems are changed. When the nuclear plant is shut down, a lot of PID tuning methods such as the Trial and Error method, Ultimate Oscillation method operation, Ziegler-Nichols method, frequency method are used to tune the PID values. But inadequate PID parameter setting can be the cause of the unstable process of the operating nuclear power plant. Therefore the results of PID parameter setting should be simulated, optimized and finally verified. This paper introduces the simulation method of PID tuning to optimize the PID parameter setting and confirms them of the actual PID controller in the operating nuclear power plants. The simulation method provides the accurate process modeling and optimized PID parameter setting of the multi-loop control process in particular.

Extended Slip-Weakening Model and Inference of Rupture Velocity (Slip-Weakening 모델의 확장과 단층 파열속도의 추정)

  • Choi, Hang;Yoon, Byung-Ick
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.5
    • /
    • pp.219-232
    • /
    • 2020
  • The slip-weakening model developed by Ohnaka and Yamashita is extended over the breakdown zone by equating the scaling relationships for the breakdown zone and the whole rupture area. For the extension, the study uses the relationship between rupture velocity and radiation efficiency, which was derived in the theory of linear elastic fracture mechanics, and the definition of fmax given in the specific barrier model proposed by Papageorgiou and Aki. The results clearly show that the extended scaling relationship is governed by the ratio of rupture velocity to S wave velocity, and the velocity ratio can be determined by the ratio of characteristic frequencies of a Fourier amplitude spectrum, which are corner frequency, fc, and source-controlled cut-off frequency, fmax, or vice versa. The derived relationship is tested by using the characteristic frequencies extracted from previous studies of more than 130 shallow crustal events (focal depth less than 25 km, MW 3.0~7.5) that occurred in Japan. Under the assumption of a dynamic similarity, the rupture velocity estimated from fmax/fc and the modified integral timescale give quite similar scale-dependence of the rupture area to that given by Kanamori and Anderson. Also, the results for large earthquakes show good agreement to the values from a kinematic inversion in previous studies. The test results also indicate the unavailability of the spectral self-similarity proposed by Aki because of the scale-dependent rupture velocity and the rupture velocity-dependent fmax/fc; however, the results do support the local similarity asserted by Ohnaka. It is also remarkable that the relationship between the rupture velocity and fmax/fc is quite similar to Kolmogorov's hypothesis on a similarity in the theory of isotropic turbulence.

A Comparative Study of External & Central Temperature Characteristics during the Moxibustion Period (애주 연소 과정에서 발생하는 애주의 표면 및 중심부의 온도변화 특성 연구)

  • Hong, Deok;Kwon, Oh-Sang;Kim, Young-Jin;Kim, Yu-Lee;Kim, Jae-Hyo;Ahn, Seong-Hun;Sohn, In-Chul
    • Korean Journal of Acupuncture
    • /
    • v.27 no.3
    • /
    • pp.47-56
    • /
    • 2010
  • Objectives : The moxibustion is the method using the heat stimulation done by attached and burned a moxa on a healing point or acupuncture point with chemical stimulation of a resin made from burning them. The purpose of this study is to find the physical and thermal characteristics of moxibustion in order to standardize the moxa therapy method. Methods : In this study, the thermal changes were observed by means of a testo 845 device, which is an infra-red thermometer to measure the thermal changes. Results & Conclusions : 1. The thermal changes on the external surface of moxibustion did not depend on the weight of the moxa; the external surface temperature was about $500^{\circ}C$. 2. The central thermal changes depend on the weight of moxa; the central temperatures ranged from $500^{\circ}C$ to $700^{\circ}C$. 3. The burning duration of moxibustion depend on the weight of moxa but that of external surface temperature did not depend on the weight of moxa in high degree : about $400^{\circ}C$. 4. The integral values of central and external temperature curves were proportional to the weight of moxa; that is central temperature curves were higher than that of external.

Scan Element Pattern and Scan Impedance of Open-Ended Waveguide Away Antenna (개방형 도파관 배열 안테나의 조향 소자 패턴 및 조향 임피던스에 관한 연구)

  • Yu, Je-Woo;Rah, Dong-Kyoon;Kim, Dong-Seok;Kim, Chan-Hong;Park, Dong-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.1 s.116
    • /
    • pp.7-14
    • /
    • 2007
  • In this paper, the scan characteristics of phased array antenna consisted of rectangular open-ended waveguide with a triangular grid are investigated. An infinite array structure is analyzed by numerically solving the integral equation for the electric field over the waveguide aperture using waveguide mode function and Floquet mode function. Next, SEP(Scan Element Pattern) and SI(Scan Impedance) characteristics are simulated by CST's MWS(Microwave Studio) and Ansoft's HFSS(High Frequency Structure Simulator) for the finite and infinite array structures. Also, validity of these approaches is verified by comparing the calculated and simulated results with the measured ones for an $8{\times}8$ subarray. Within 10.5 % fractional bandwidth in the X-band, the fabricated subarray showed the flat gain characteristic in the scan range of ${\pm}45^{\circ}C$ in the E-plane(azimuth) and ${\pm}20^{\circ}C$ in the H-plane(elevation), and also showed the return loss characteristic of less than -10 dB.

Dosimetric comparison of coplanar and non-coplanar volumetric-modulated arc therapy in head and neck cancer treated with radiotherapy

  • Gayen, Sanjib;Kombathula, Sri Harsha;Manna, Sumanta;Varshney, Sonal;Pareek, Puneet
    • Radiation Oncology Journal
    • /
    • v.38 no.2
    • /
    • pp.138-147
    • /
    • 2020
  • Purpose: To evaluate the dosimetric variations in patients of head and neck cancer treated with definitive or adjuvant radiotherapy using optimized non-coplanar (ncVMAT) beams with coplanar (cVMAT) beams using volumetric arc therapy. Materials and Methods: Twenty-two patients of head and neck cancer that had received radiotherapy using VMAT in our department were retrospectively analyzed. Each of the patients was planned using coplanar and non-coplanar orientations using an optimized couch angle and fluences. We analyzed the Conformity Index (CIRTOG), Dose Homogeneity Index (DHI), Heterogeneity Index (HIRTOG), low dose volume, target and organs-at-risk coverage in both the plans without changing planning optimization parameters. Results: The prescription dose ranged from 60 Gy to 70 Gy. Using ncVMAT, CIRTOG, DHI and HIRTOG, and tumor coverage (ID95%) had improved, low dose spillage volume in the body V5Gy was increased and V10Gy was reduced. Integral dose and intensity-modulated radiation therapy factor had increased in ncVMAT. In the case of non-coplanar beam arrangements, maximum dose (Dmax) of right and left humeral head were reduced significantly whereas apex of the right and left lung mean dose were increased. Conclusion: The use of ncVMAT produced better target coverage and sparing of the shoulder and soft tissue of the neck as well as the critical organ compared with the cVMAT in patients of head and neck malignancy.

Design of an Inexpensive Heater using Chip Resistors for a Portable Real-time Microchip PCR System (저항소자를 이용한 휴대형 Real-time PCR 기기용 히터 제작)

  • Choi, Hyoung-jun;Kim, Jeong-tae;Koo, Chi-wan
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.295-301
    • /
    • 2019
  • A heater in a portable real-time polymerase chain reaction(PCR) system is one of the important factors for controlling the PCR thermocycle precisely. Since heaters are integrated on a small-sized PCR chip for rapid heating and fabricated by semiconductor processes, the cost of producing PCR chips is high. Here, we propose to use chip resistors as an inexpensive and accurate temperature control method. The temperature distribution was simulated using one or two chip resistors on a real-time PCR chip and the PCR chip with uniform temperature distribution was fabricated. The temperature rise and fall rates were $18^{\circ}C/s$ and $3^{\circ}C/s$, respectively.

Measurement strategy of a system parameters for the PI current control of the A.C. motor (교류 전동기의 PI 전류제어를 위한 시스템 파라미터 계측법)

  • Jung-Keyng Choi
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.5
    • /
    • pp.223-229
    • /
    • 2023
  • This Paper propose the method that measure main system parameters for PI(proportional-integral) current control of a.c. motor adopting the vector control technique. For current control, the PI control input is could be tuning by several selective methods. Among the several methods, the method that using the main system parameters, wire resistance and inductance, are frequently used. In this study, the technique to dissect and measure these two system parameters through the results of simple feedback control. This analytic measurement method is measuring parameters step by step dissecting the results of P control using simple proportional feedback gain about the unit step or multiple step reference command. This strategy is an real time analytic measurement method that calculate current control gains of torque component and flux component both for vector control of A.C. motor without introducing the further measurement circuits and complex measuring algorithms.