• Title/Summary/Keyword: $Ar^+$ laser

Search Result 328, Processing Time 0.025 seconds

Thin-film optical waveguide $K^{+}$-ion sensor using the evanescent field absorption (소산장 흡수를 이용한 박막 광도파로형 칼륨이온센서)

  • Lee, Su-Mi;Koh, Kwang-Nak;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.214-220
    • /
    • 1997
  • A thin film optical waveguide sensor has been developed to measure and analyze quantitatively some inherent optical properties of biochemical substances. In this paper, two different kinds of thickness of thin film waveguide were prepared by RF sputtering of Corning-7059 glass(n = 1.588 at ${\lambda}=\;514nm$, Ar laser) on Pyrex glass substrates. We made a sensing membrane coated on the thin film waveguide with the poly(vinyl chloride-co-vinyl acetate-co-vinyl alcohol) (91 : 3 : 6) copolymer membrane based on $H^{+}$-selective chromoionophore and $K^{+}$-selective neutral ionophore and then proposed the thin film opptical waveguide ion sensor which can select a potassium ion. This sensor based ell the absorbance change by utilizing chromoionophore and neutral ionophore, which changes their absorption spectrum in the UV-vis region upon complexation of the corresponding ionic species, have been reported. The sensitivity dependence of the proposed sensor on interaction length, waveguide thickness, and content of a chromoionophore was investigated. This sensor has the measurement range of $10^{-6}M{\sim}1M$ for $K^{+}$ concentration and 90% response time of duration within 1 min. Also, our thin film optical waveguide sensor using the evanescent field was investigated as compared with conventional transmission sensor or optode sensor by the optical fiber. The sensitivity of thin-film waveguide $K^{+}$ sensor is higher than that of the conventional transmission sensor. The proposed sensor is expected to be useful to biochemical, medical, environmental inspection and so on.

  • PDF

Development of a High Resolution Cinematic Particle Image Velocimetry and Its Application to measurement of Unsteady Complex Turbulent Flows (고분해능 Cinematic PIV 시스템의 개발과 비정상 복잡 난류유동측정에의 응용)

  • Kim, Kyung-Chun;Park, Kyung-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.536-541
    • /
    • 2001
  • A high resolution digital cinematic Particle Image Velocimetry(PIV) has been developed. The system consists of a high speed CCD camera, a continuous Ar-ion laser and a computer with camera controller. To improve the spatial resolution, we adopt a Recursive Technique for velocity interrogation. At first, we obtain a velocity vector for a larger interrogation window size based on the conventional two-frame cross-correlation PIV analysis using the FFT algorithm. Based on the knowing velocity information, more spatially resolved velocity vectors are obtained in the next iteration step with smaller interrogation windows. The correct velocity vector at the first step is found to be critical, so we apply a Multiple Correlation Validation(MCV) technique in order to decrease the spurious vectors. The MCV technique turns out to improve SNR(Signal to Noise Ratio) of the correlation table. The developed cinematic PIV method has been applied to the measurement of the unsteady flow characteristics of a Rushton turbine mixer. A total of 3,245 instantaneous velocity vectors were successfully obtained with 4 ms time resolution. The acquired spatial resolution corresponds the performance of the conventional high resolution digital PIV system using a $1K{\times}1K$ CCD camera.

  • PDF

Development of Genetic Algorithm based 3D-PTV and its Application to the Measurement of the Wake of a Circular Cylinder (GA기반 3D-PTV 개발과 원주 후류계측)

  • Doh, D.H.;Cho, G.R.;Cho, Y.B.;Moon, J.S.;Pyun, Y.B.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.548-554
    • /
    • 2001
  • A GA(Genetic Algorithm) based 3D-PTV technique has been developed. The measurement system consists of three CCD cameras, Ar-ion laser, an image grabber and a host computer. The fundamental of the developed technique was based on that one-to-one correspondence is found between two tracer particles selected at two different image frames taking advantage of combinatorial optimization of the genetic algorithm. The fitness function controlling reproductive success in the genetic algorithm was expressed by a kind of continuum theory on the sparsely distributed particles in space. In order to verify the capability of the constructed measurement system, a performance test was made using the LES data set of an impinging jet. The developed 3D-PTV system was applied to the measurement of flow characteristics of the wake of a circular cylinder.

  • PDF

Visualization of Smoke Flow in the Subway Fire (지하철 화재발생시 역사내 화재연기 거동 가시화 연구)

  • Choi Chang Jin;Jung Hae Gon;Kim Sang Moon;Kim Kyung Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.64-68
    • /
    • 2005
  • In this study, the smoke flows of the inner subway station were visualized through a numerical analysis and visualization experiment in the subway fire. A transparent acrylic model was designed and installed as 1:25th scale-down as the actual subway station by using geometrical similarity The properties of subway fire were reconstructed according to Densimetric Froude Similarity. The 47 to 53 ratio of the mixed air and Helium was inputted in the inner acrylic model to describe 1MW fire intensity with reference to the experiment paper. For the same time, the fire smoke from a smoke generator was inputted in the inner acrylic model with the mixture. At this time, the buoyancy effect of Helium gas went up the smoke to the acrylic model. When the sheet beam of Ar-lon laser was given out to the top and stair of subway model, the digital camcorder took the images of the scattered cluster of smoke particles when applying the smoke management system and PSD.

  • PDF

Fabrication of sing1e layer $d^2B_{z}$/dxdy second-order SQUID gradiometer (단일층 $d^2B_{z}$/dxdy SQUID 2차 미분기 설계 및 제작)

  • 황윤석;박승문;이순걸;김인선;박용기
    • Progress in Superconductivity
    • /
    • v.4 no.2
    • /
    • pp.109-113
    • /
    • 2003
  • We have developed a planar-type single layer second-order $high-T_{c}$ SQUID gradiometer, which can detect the $d^2$$B_{z/}$dxdy of the second-order field gradient. This SQUID gradiometer consists of four-way 'clover-leaf' pick-up loops and is coupled directly to a 4-junction dc SQUID in such a way that the coupling polarity of the two diagonal loops is opposite to that of the other two loops. The pickup loops are intrinsically balanced for both uniform field and the 1 st-order field gradient. The $YBa_2$$Cu_3$$O_{7}$ thin film was made by pulsed laser deposition method on $SrTiO_3$ single crystal substrate and patterned by photolithography with Ar ion milling technique. Response of this gradiometer was tested for both uniform field and the 2nd-order field gradient. Details of the design, fabrication, and results will be discussed.

  • PDF

Macroscopic Characteristics of Evaporating Dimethyl Ether(DME) Spray (Dimethyl Ether(DME)의 증발과 거시적 분무 특성)

  • Yu, Jun;Lee, Ju-Kwang;Bae, Choong-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.3
    • /
    • pp.58-64
    • /
    • 2003
  • Dimethyl Ether(DME) has been considered as one of the most attractive alternative fuels for compression ignition engine. Its main advantage in diesel engine application is high efficiency of diesel cycle with soot free combustion though conventional fuel injection system has to be modified due to the physical properties of DME. Experimental study of DME and conventional diesel spray employing a common-rail type fuel injection system with a 5-hole sac type injector was performed in a constant volume vessel pressurized by nitrogen gas. Spray cone angles and penetrations of the DME spray were characterized and compared with those of diesel. For evaluation of the evaporating characteristics of the DME, shadowgraphy technique employing an Ar-ion laser and an ICCD camera was adopted. Tip of the DME spray was formed in mushroom-like shape at atmospheric chamber pressure, which disappeared in higher chamber pressure. Spray tip penetration and spray cone angle of the DME became similar to those of diesel under 3MPa of chamber pressure. Higher injection pressure provided wider vapor phase area while it decreased with higher chamber pressure condition.

Study on an Enhanced Manufacturing Process for Mobile Camera Window Glass (Mobile용 Camera Window의 공정 개선에 관한 연구)

  • Ahn, Hae Won;Shin, Ki Hoon;Oh, Jae Ho;Kim, Hak Chul;Kwon, Soo Kun;Choi, Seong Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.5
    • /
    • pp.15-21
    • /
    • 2015
  • The glass used for Mobile Camera Window is required to have high strength. Cell type manufacturing by means of CNC is widely used for camera window. Individual loading and unloading is needed for each process, such as painting and PVD, in cell type manufacturing. The purpose of this study is to search the enhanced manufacturing process with sheet type throughout bulk unit production in painting and PVD. This study includes sheet type manufacturing processes such as laser cutting, wet etching, 2nd tempering, printing, and AF/AR coating.

Development of Image-based Fluorescence Photobleaching Technique for Measuring Macromolecule Diffusion in Biological Porous Medium (생체 다공성 매질에서 분자 확산 측정을 위한 영상 기반 형광 광표백 기법 개발)

  • Lee, Dong-Hee;Lee, Jeong-Hoon;Park, Choon-Ho;Kim, Jung-Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.7 no.1
    • /
    • pp.9-13
    • /
    • 2009
  • Fluorescence recovery after photobleaching (FRAP) has been widely used for the measurement of molecular diffusion in living cells and tissues. We developed an image-based FRAP (iFRAP) technique using a modified real-time microscope and a 488 nm Ar-ion laser. A fractional intensity curve was obtained from the time-lapse images of fluorescence recovery in the bleached spot to determine the diffusion coefficient of fluorescently labeled macromolecules in porous medium. We validated iFRAP through experiments with agar gels (0.5% and 1.5% w/v) containing FITC-Dextrans (10, 70 and 500 kDa MW). Further validation was performed by a Monte Carlo approach, where we simulated the three-dimensional random walk of macromolecules in agar gel model. Diffusion coefficients were deduced from the mean square displacement curves and showed good agreements with those measured by iFRAP.

탄소 음이온 빔에 의해 증착된 DLC 필름의 특성 평가

  • 김인교;김용환;이덕연;최동준;한동원;백홍구
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.59-59
    • /
    • 1999
  • DLC(diamond-like carbon)필름은 다이아몬드와 유사한 강도, 낮은 마차계수, 높은 Optical band gap, NEA(negative electron affinity)등의 우수한 특성을 가지고 있어, 내마모 코팅이나 정보저장 매체의 윤활 코팅, FED(field emission display)의 전계방출소자등 다양한 분야에의 응용이 연구되고 있다. DLC 필름은 PECVD(plasma enhanced chemical vapor deposition), IBAD(ion beam assisted deposition), Laser ablation, Cathodic vacuum arc등의 process를 이용하여 증착되고 있다. 특히 이러한 필름의 물성은 입사되는 이온의 에너지에 의해 좌우되는데, Lifshitz 등의 연구에 의하여 hyperthermal species를 이용한 DLC 필름의 성장은 초기에 subsurface로의 shallow implantation이 일어난 후 높은 sp3 fraction을 갖는 필름이 연속적으로 성장한다는 subplantation model이 제시 되었다. 본 연구에서는 기판과 subplantation 영역이 이후 계속하여 증착되는 순수 DLC 필름의 특성 변호에 미치는 영향에 대하여 관심을 가지고 실험을 행하였다. 본 실험에서는 상기 제시되어 있는 방법보다도 더욱 정확하고도 독립적으로 탄소 음이온의 에너지와 flux를 조절할 수 있는 Cs+ ion beam sputtering system을 이용하여 탄소 음이온의 에너지를 40eV에서 200eV까지 변화시키며 필름을 증착하였다. Si(100) 웨이퍼를 기판으로 사용하였고 증착 압력은 5$\times$10-7torr 였으며 인위적인 기판의 가열은 하지 않았다. 또한 Ion beam deposited DLC film의 growth process를 연구하기 위하여 200eV의 탄소 음이온을 시간(증착두께)을 변수로 하여 증착하였고, 이 때에는 Kaufman type의 gas ion beam을 이용하여 500eV의 Ar+ ion으로 pre-sputering을 행하였다. 탄소 음이온의 에너지와 증착두께에 따라 증착된 film 내의 sp3/sp2 ratio 의 변화를 XPS plasmon loss 와 Raman spectra를 이용하여 분석하였다. 또한 증착두께에 따른 interlayer의 결합상태를 관찰하기 위하여 AES와 XPS 분석을 보조로 행하였다.

  • PDF

Extingushiment by the Colling Effect of the Fuel Surface with Pool Fires (Pool 화재에서의 표면 냉각에 의한 소화)

  • 한용식;김명배;신현동
    • Fire Science and Engineering
    • /
    • v.11 no.4
    • /
    • pp.15-23
    • /
    • 1997
  • A series of measurements and visualization to investigate the extingushiment of water sprays with pool fires is presented. Fire source is a small-scale pool burner with methanol, ethanol and gasoline. Measurements of temperature, O2, CO2, and CO concentrations along the plume centerline are carried out to observe pool structures without water sprays. Visualization by the Ar-ion laser sheet flow pattern of droplets of the sprays above the pool fires. It is observed than in the case of methanol and ethanol, water sprays continuously penetrate into the center of fuel surfaces. The gasoline pool fire allows intermittent penetration of water sprays because of pulsating characteristics of the gasoline flame. To evaluate the cooling effect of the fuel surface by the sprays, the temperature was measured at the fuel surface. As soon as the mists reach the fuel surface of methanol and ethanol, the temperatures of the fuel surface decrease rapidly below the boiling point, and then the fires are extinguished. Due to the application of mist upon the gasoline fire, though the fuel temperature decrease abruptly at the time of the injection, such a repid decrease do not continue till the extinction point.

  • PDF