• 제목/요약/키워드: $AFM_1$

검색결과 983건 처리시간 0.029초

Pitch Measurement of 150 nm 1D-grating Standards Using an Nano-metrological Atomic Force Microscope

  • Jonghan Jin;Ichiko Misumi;Satoshi Gonda;Tomizo Kurosawa
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제5권3호
    • /
    • pp.19-25
    • /
    • 2004
  • Pitch measurements of 150 nm one-dimensional grating standards were carried out using a contact mode atomic force microscopy with a high resolution three-axis laser interferometer. This measurement technique was named as the 'nano-metrological AFM'. In the nano-metrological AFM, three laser interferometers were aligned precisely to the end of an AFM tip. Laser sources of the three-axis laser interferometer in the nano-metrological AFM were calibrated with an I$_2$ stabilized He-Ne laser at a wavelength of 633 nm. Therefore, the Abbe error was minimized and the result of the pitch measurement using the nano-metrological AFM could be used to directly measure the length standard. The uncertainty in the pitch measurement was estimated in accordance with the Guide to the Expression of Uncertainty in Measurement (GUM). The primary source of uncertainty in the pitch-measurements was derived from the repeatability of the pitch-measurements, and its value was about 0.186 nm. The average pitch value was 146.65 nm and the combined standard uncertainty was less than 0.262 nm. It is suggested that the metrological AFM is a useful tool for the nano-metrological standard calibration.

In-field evaluation of clinoptilolite feeding efficacy on the reduction of milk aflatoxin M1 concentration in dairy cattle

  • Katsoulos, Panagiotis D.;Karatzia, Maria A.;Boscos, Constantinos;Wolf, Petra;Karatzias, Harilaos
    • Journal of Animal Science and Technology
    • /
    • 제58권7호
    • /
    • pp.24.1-24.7
    • /
    • 2016
  • Background: Clinoptilolite is a natural zeolite with high adsorption capacity for polar mycotoxins such as aflatoxins. The efficacy of clinoptilolite in ameliorating the toxic effects of aflatoxicosis has been proven in monogastric animals, but there is no such evidence for ruminants. The aim of this study was to evaluate, under field conditions, whether the dietary administration of clinoptilolite in dairy cows could reduce the concentration of aflatoxin M1 ($AFM_1$) in bulk-tank milk, in farms with higher than or close to $0.05{\mu}g/kg$ of milk (European maximum allowed residual level). An objective of the present study was also to investigate the effect of particle size of clinoptilolite on aflatoxin binding. Methods: Fifteen commercial Greek dairy herds with AFM1 concentrations in bulk tank milk ${\geq}0.05{\mu}g/kg$ were selected. Bulk tank milk AFM1 was determined prior to the onset and on day 7 of the experiment. Clinoptilolite was added in the total mixed rations of all farms at the rate of 200 g per animal per day, throughout this period. Two different particle sizes of clinoptilolite were used; less than 0.15 mm in 9 farms (LC group) and less than 0.8 mm in 6 farms (HC group). Results: Clinoptilolite administration significantly reduced $AFM_1$ concentrations in milk in all farms tested at an average rate of 56.2 % (SD: 15.11). The mean milk $AFM_1$ concentration recorded on Day 7 was significantly (P < 0.001) lower compared to that of Day 0 ($0.036{\pm}0.0061$ vs. $0.078{\pm}0.0074{\mu}g/kg$). In LC group farms the reduction of milk $AFM_1$ concentration was significantly higher than HC group farms ($0.046{\pm}0.0074$ vs. $0.036{\pm}0.0061{\mu}g/kg$, P = 0.002). As indicated by the Pearson correlation, there was a significant and strong linear correlation among the milk $AFM_1$ concentrations on Days 0 and 7 (R = 0.95, P < 0.001). Conclusions: Dietary administration of clinoptilolite, especially of smallest particle size, at the rate of 200 g per cow per day can effectively reduce milk $AFM_1$ concentration in dairy cattle and can be used as a preventive measure for the amelioration of the risks associated with the presence of aflatoxins in the milk of dairy cows.

하이브리드형 AFM/SCM을 이용한 레이저 미세 가공 표면 측정 (Precision measurement of a laser micro-processing surface using a hybrid type of AFM/SCM)

  • 김종배;김경호;배한성;남기중;이대철;서운학
    • 한국레이저가공학회:학술대회논문집
    • /
    • 한국레이저가공학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.123-127
    • /
    • 2006
  • Hybrid type microscope with a Scanning Confocal Microscope (SCM) and a shear-force Atomic Force Microscope (AFM) is suggested and preliminarily studied. A image of $120{\times}120{\mu}m^2$ is obtained within 1 second by SCM because scan speed of a X-axis and Y-axis are 1kHz and 1Hz, respectively. Shear-force AFM is able to correctly measure the hight and width of sample with a resolution 8nm. However, the scan speed is slow and it is difficult to distinguish a surface composed of different kinds of materials. We have carried out the measurement of total image of a sample by SCM and an exact analysis of each image by shear-force AFM.

  • PDF

Regiospecific Orientation of Single-chain Antibody and Atomic Force Microscope (AFM) Images

  • Kyusik Yun;Park, Seonhee;Hyeonbong Pyo;Kim, Seunghwan;Lee, Sooyeul
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제4권1호
    • /
    • pp.72-77
    • /
    • 1999
  • An antibody containing a genetically engineered lipid group at the N-termunus and a hexahistidinyl tag at the C-terminus (Lpp-scF-His6) was immobilized in an oriented manner on the surface of liposome. Liposomes, consisting of antibody and phosphatidyl-choline, have been prepared and imaged by AFM. For AFM visualization, the resulting liposomes were bound on the surface of mica by two different mechanisms. The histidine tags present in the antibody molecules of the immonuliposome were anchored to the NiCl2 treated mica surface. Alternatively, the immunoliposomes were immunochemically bound on antigen-coated mica surface. Both approaches yielded liposomes which were clearly imaged without damage by AFM in ambient condition.

  • PDF

Advanced atomic force microscopy-based techniques for nanoscale characterization of switching devices for emerging neuromorphic applications

  • Young-Min Kim;Jihye Lee;Deok-Jin Jeon;Si-Eun Oh;Jong-Souk Yeo
    • Applied Microscopy
    • /
    • 제51권
    • /
    • pp.7.1-7.9
    • /
    • 2021
  • Neuromorphic systems require integrated structures with high-density memory and selector devices to avoid interference and recognition errors between neighboring memory cells. To improve the performance of a selector device, it is important to understand the characteristics of the switching process. As changes by switching cycle occur at local nanoscale areas, a high-resolution analysis method is needed to investigate this phenomenon. Atomic force microscopy (AFM) is used to analyze the local changes because it offers nanoscale detection with high-resolution capabilities. This review introduces various types of AFM such as conductive AFM (C-AFM), electrostatic force microscopy (EFM), and Kelvin probe force microscopy (KPFM) to study switching behaviors.

Aflatoxin M1 in Pasteurized Market Milk in Korea

  • Hwang, Kyu-Choon;Hwang, Joo-Yea;Kim, Hyoun-Wook;Oh, Mi-Hwa
    • 한국축산식품학회지
    • /
    • 제32권3호
    • /
    • pp.376-378
    • /
    • 2012
  • Aflatoxin M1, ingested as aflatoxin B1 via contaminated feedstuff and later converted into, is a major problematic target for milk safety control among the aflatoxin class. Korean government has controlled level of AFM1 in milk at 500 ppt as maximum residue level (MRL), and more recently, government also publicized the proposal for more strict control on fungal toxins about infant and baby foods. In this study the levels of Aflatoxin M1 (AFM1) of 42 marketed milk samples were determined with Enzyme-Linked Immunosorbent Assay (ELISA) to evaluate the status on the contamination of Aflatoxin M1. The evaluated ELISA performances of limit of detection (LOD) and the half maximal inhibitory concentration ($IC_{50}$) were 5 pg/mL (ppt) and 49 ppt, respectively. In all 42 samples, AFM1 appeared above the 5 ppt, with the average of 21 ppt and the range of up to 90 ppt. Only 3 (7%) of samples showed the level of contamination above the EU MRL (50 ppt). Although there was incidence of higher level of contamination compared with previous reports, the result of this study requires more intensive study to control of AFM1 in milk and infant foods.

AFM을 이용한 나노급 $Ge_2Sb_2Te_5$의 전기적 특성

  • 배병주;홍성훈;조중연;오상철;황재연;이헌
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2009년도 춘계학술발표대회
    • /
    • pp.21.1-21.1
    • /
    • 2009
  • 상변화 메모리는 비휘발성 메모리이면서 빠른 동작 속도, 낮은 동작 전압 등 다양한 장점을 지니고 있어 차세대 메모리로 주목 받고 있다. 최근 상변화 메모리의 동작 전류를 감소시키기 위해 상변화 물질 및 전극 물질에 대한 연구를 진행하고 있으며, 소자의 크기를 최소화 하기 위한 연구가 진행되고 있다. 본 연구에서는 나노 임프린트 리소그래피와 전도성 AFM을 이용하여 나노급 상변화 물질의 특성을 평가하였다. 나노급 상변화 물질을 형성하기 위해 열경화성 나노 임프린트 리소그래피를 이용하여 $Ge_2Sb_2Te_5$(GST)/Mo/SiO2 기판 위에 200nm급 홀 패턴을 형성하였다. 홀 패턴에 Cr을 증착하여 리프트 오프 한 뒤 Cr을 하드 마스크로 사용하여 GST를 식각하였다. 그 결과, Mo 하부 전극 위에200nm 지름과 100nm 높이를 가지는 GST 나노 기둥을 형성하였다. GST 나노 기둥의 전기적 특성 평가를 위해 저항 측정 장비 및 펄스 발생기와AFM을 사용하였다. AFM은 접촉 모드로 설정하였으며, Pt가 코팅된 AFM tip을 사용하여 Cr 하드 마스크와 함께 상부 전극으로 사용하였다. GST 나노 기둥을 초기화 시키기 위해 I-V sweep을 하였으며, 그 결과 $1M\Omega$에서 $10\;k\Omega$으로 저항이 변화함을 확인하였다. GST 나노 기둥은 2V, 5ns의 리셋 펄스에서 비정질로 변화하였으며, 1.3V, 150ns의 셋 펄스에서 결정질로 변화하였다. 이 동작 전압으로 5번의 스위칭 특성을 평가하였으며, 이 결과는 소자 형태의 200nm 급GST의 특성과 유사하여 나노급 상변화 물질을 테스트하는 새로운 방법으로 사용될 수 있을 것이다.

  • PDF

A High-Speed Single Crystal Silicon AFM Probe Integrated with PZT Actuator for High-Speed Imaging Applications

  • Cho, Il-Joo;Yun, Kwang-Seok;Nam, Hyo-Jin
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권1호
    • /
    • pp.119-122
    • /
    • 2011
  • A new high speed AFM probe has been proposed and fabricated. The probe is integrated with PZT actuated cantilever realized in bulk silicon wafer using heavily boron doped silicon as an etch stop layer. The cantilever thickness can be accurately controlled by the boron diffusion process. Thick SCS cantilever and integrated PZT actuator make it possible to be operated at high speed for fast imaging. The resonant frequency of the fabricated probe is 92.9 kHz and the maximum deflection is 5.3 ${\mu}m$ at 3 V. The fabricated probe successfully measured the surface of standard sample in an AFM system at the scan speed of 600${\mu}m$/sec.

AFM을 이용한 PMMA (Poly Methyl Methacrylate) 박막의 나노트라이볼로지 연구 (Nanotribology of PMMA Thin Films Using an AFM)

  • 김승현;김용석
    • 소성∙가공
    • /
    • 제13권1호
    • /
    • pp.59-64
    • /
    • 2004
  • Nano-scratch tests were performed on PMMA thin films spin-coated on a Si substrate using an atomic force microscopy (AFM) with loads ranging form 10nN to 100nN. At low loads, a ridge pattern was formed on the PMMA thin film surface. No wear particles were observed during the pattern-forming mild wear. At high loads, severe wear by plowing occurred, accompanied by wear particles. The film with the highest hardness showed the highest wear resistance. Friction force generated during the scratching was measured, which was closely related with surface deformation of the film. A simple empirical equation to deduce scratch hardness of the film from a linear fixed-distance scratch test was proposed, and scratching-speed dependency of the scratch hardness was displayed.

알루미늄 합금 피로 스트라이에이션의 나노 스케일 관찰 (Nano-Scale Observation of Fatigue Striations for Aluminum Alloy)

  • 최성종;권재도
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.153-158
    • /
    • 2000
  • Atomic Force Microscope (AFM) was used to study cross sectional profiles and dimensions of fatigue striations in 2017-T351 aluminum alloy. Their widths (SW) and heights $(SH,\;SH_h)$ were measured from the cross sectional Profiles of three-dimension AFM images. The following results that will be helpful to understand the fatigue crack growth mechanism were obtained. (1) Coincidence of the crack growth rate with the striation width was found down to the growth rate of $10^{-5}$ mm/cycle. (2) The relation of $SH={\alpha}(SW)^{1.2}$ was obtained. (3) The ratio of the striation height to its width SH/SW and did not depend on the stress intensity factor range ${\Delta}K$ and the stress ratio R. From these results, the applicability of the AFM to nano-fractography is discussed.

  • PDF