• Title/Summary/Keyword: $2{\times}$ magnification

Search Result 134, Processing Time 0.023 seconds

Development of Dot Sight with 2× Magnification (2× 배율 도트사이트 장치의 개발)

  • Lee, Dong-Hee;Park, Seung-Hwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.435-440
    • /
    • 2012
  • Purpose: The purpose of this study is developing the dot sight with a $2{\times}$ magnification. Methods: To magnify the target when we see the far through the non-magnified dot sight, we develop the new optical device which is detachable to the non-magnified dot sight. A new optical device is designed to facilitate the transition of an existing non-magnification ($1{\times}$) dot sight to the $2{\times}$ magnification dot sight. Results: We could design and fabricate the $2{\times}$ afocal optical system which is detachable to the non-magnified dot sight and be composed by a pair of doublet. When the system developed in this study was used, we could aim the external target by twice magnification, so we could further improve the accuracy of aim. Conclusions: We could design and manufacture the $2{\times}$ afocal optical system which can be detachable to the non-magnified dot sight. With the results, we could aim the external target by twice magnification, so we could further improve the accuracy of aim.

Development of the Precision Positioning Mechanism by Nano Displacement Magnification Device (나노 변위확대기구의 정밀위치결정기구에 관한 연구)

  • Park, Chang-Yong;Kweon, Hyun-Kyu;Zhao, Zhijun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.1
    • /
    • pp.97-103
    • /
    • 2013
  • A new precision positioning mechanism for stage was been developed by Displacement Magnification Device(DMD) in this paper. The DMD was composed of the beam and multilayer piezoelectric actuators. The theoretical and experimental analysis of DMD to enlarge displacement more then 50times were discussed. And the 2-axis stage by using displacement amplification apparatus was added in the new DMD, and it was able to do it through finite element analysis and experiment. As the results, the magnification of DMD can be obtained about $100{mu}m$ displacement to the 10V input voltage($1.5{mu}m$). And the about 50nm of linearity error in the $30{mu}m$ measurement range and 20times of the amplification in displacement can be measured. In addition, the experimental results are confirmed the possibility of millimeter displacement characteristics and correspond to finite element analysis results.

Study on the Elimination of Heavy Metal Pollutants in the Soil by Vascular Plant in the River Area (하천유역의 관속식물을 이용한 토양내의 중금속 오염원 제거에 관한 연구)

  • 강경홍;김인성
    • Journal of Korea Soil Environment Society
    • /
    • v.1 no.2
    • /
    • pp.23-34
    • /
    • 1996
  • The biological magnification of Pb, Cu, Zn and Fe in vascular plant, Persicaria thunbergii, Trapa japonica and Nymphoides peltata natually grown at the river and riverside and relationship between the concentration of heavy metals in these vascular plants and in the soil were investigated in the Chonju river, Chonju city. The biological magnification values of these metals in P thunbergii were founded as follows ; Pb, Cu, Zn and Fe were 80.4~254.6$mu\textrm{g}$/g, 284.6~688.4$mu\textrm{g}$/g, 635.5~1979.4$mu\textrm{g}$/g and 1160.0~3590.9$mu\textrm{g}$/g respectively. In the case of T. japonica, Pb, Cu, Zn and Fe were 107.8~306.0$mu\textrm{g}$/g, 282.7~963.0p$mu\textrm{g}$/g, 1328.3~3546.$mu\textrm{g}$/g and 656.8~9944.0$mu\textrm{g}$/g and in N. peltata, 140.1~ 193.9$mu\textrm{g}$/g, 187.7~327.3$mu\textrm{g}$/g, 1126.6~1723.6$mu\textrm{g}$/g and 611.7~1914.6$mu\textrm{g}$/g respectively. The amount of the biological magnification of heavy metals in the leaf, stem and root of these plants was generally increased in the sequence of leaf

  • PDF

Robotic Microsurgery Optimization

  • Brahmbhatt, Jamin V.;Gudeloglu, Ahmet;Liverneaux, Philippe;Parekattil, Sijo J.
    • Archives of Plastic Surgery
    • /
    • v.41 no.3
    • /
    • pp.225-230
    • /
    • 2014
  • The increased application of the da Vinci robotic platform (Intuitive Surgical Inc.) for microsurgery has led to the development of new adjunctive surgical instrumentation. In microsurgery, the robotic platform can provide high definition $12{\times}-15{\times}$ digital magnification, broader range of motion, fine instrument handling with decreased tremor, reduced surgeon fatigue, and improved surgical productivity. This paper presents novel adjunctive tools that provide enhanced optical magnification, micro-Doppler sensing of vessels down to a 1-mm size, vein mapping capabilities, hydro-dissection, micro-ablation technology (with minimal thermal spread-$CO_2$ laser technology), and confocal microscopy to provide imaging at a cellular level. Microsurgical outcomes from the use of these tools in the management of patients with infertility and chronic groin and testicular pain are reviewed. All these instruments have been adapted for the robotic console and enhance the robot-assisted microsurgery experience. As the popularity of robot-assisted microsurgery grows, so will its breadth of instrumentation.

New Data Matrix Structure and Algorithm Implementation for Digital Holographic Data Storage (디지털 홀로그래픽 정보 저장을 위한 새로운 데이터 매트릭스 구조 및 알고리즘 구현)

  • Choi, Jae-Kwang;Kim, Jung-Hoi;Kim, Nam
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.2
    • /
    • pp.17-25
    • /
    • 2004
  • In this Paper, new data matrix structure and respective processing algorithm for digital holographic storage are Proposed. Data matrix consists of user data and reference grid which is used to compensate geometrical errors such as magnification, shift and rotation of stored information. Processing algorithm identifies the location of reference grid and extracts user data. As a result of experiment, raw BER in case of shit, rotation and magnification are 3.09${\times}$10$^{-18}$ , 6.14${\times}$10$^{-12}$ , 1.2${\times}$10$^{-7}$ , respectively.

Enlargement of Field-of-View (FOV) of the CCD Camera by the Current Adjustment of the Projection Lens System in the KBSI-HVEM (KBSI-HVEM 투사렌즈 전류제어에 의한 CCD Camera의 Field of View(FOV) 확장)

  • Kim, Young-Min;Shim, Hyo-Sik;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • v.35 no.4
    • /
    • pp.98-104
    • /
    • 2005
  • A FOV (field-of-view) of the HV-MSC (high voltage multi-scan CCD, $1024{\times}1024$ pixels) camera mounted in the post-column HV-GIF (high voltage gatan image filter) has been drastically enlarged by the projection lens current adjustment. An imaging area of the HV-MSC camera obtained at the lowest magnification (2,000x) is $112{\mu}m^2$ which corresponds to the recording area of the film at the magnification of 8,800x, while the achievable recording area is only $0.43{\mu}m^2$ at the same magnification without this technique. Ignoring the image distortion of less than 5%, we have designed an on-site reference graph to estimate projection lens currents for microscope magnifications above 8,800x, where the recording area on the HVMSC is same as that on the film.

Design and fabrication of a zoom optics having 20 magnification range for mid-IR(3.7-4.8$\mu$m) FLIR system (3.7-4.8$\mu$m 파장대역 FLIR 시스템을 위한 20:1 줌 렌즈 광학계 설계 및 제작)

  • 김현숙;김창우;홍석민
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.6
    • /
    • pp.462-467
    • /
    • 1999
  • This paper describes the design and fabrication of mid-IR $(3.7-4.8{\mu}m)$ zoom optics which is used for FUR (Forward Looking Infra-Red) system with 320 $\times$ 240 focal plane arrays. The zoom optics has 20 magnification range and maximun 40$^{\circ}$$\times$30$^{\circ}$ of super wide field of view. The locus of zoom is almost linear, which gives easy access of mechanical and electro-mechanical design. The on-axis MTF of zoom optics has been measured and it shows diffraction limited optical performance. For example, it gives 0.692 at 24 cycles/mm at highest magnification, and 7.6 cycles/mradof resolving power is achieved with the operation of attached micro-scanning system.system.

  • PDF

A STUDY OF SURFACE ROUGHNESS OF COMPOSITE RESIN (복합레진의 표면조도에 관한 연구)

  • Park, Ki-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.1
    • /
    • pp.108-115
    • /
    • 2000
  • This study was designed to compare the effect of polishing on surface roughness of composite resin. We used Z100(3M) composite resin and placed the composite resin in the hole (4mm thick and 4mm in diameter) of vinyl plate and polymerized it under manufacturer's instructions. Samples were divided into 5 groups by polishing methods. Group 1 was control: resin was polymerized under glass plate, Group 2: resin was polymerized without any polishing procedure, Group 3: resin was polymerized with a polishing procedure of abrasive disc, Group 4: bonding agent was applyed in thin layer and polymerized on the polished polymerized resin surface. Group 5: resin was polymerized under transparent celluloid strip. The surface roughness of each specimen was measured with Sufacoder SEF-30D (Kosaka lab. Ltd) under 0.08mm cut off, 0.05mm/s stylus speed, ${\times}40$ horizontal magnification, ${\times}5000$ vertical magnification. The results were as follows : 1. Group 1 showed the most smooth surface in this study. 2. Group 3 showed more rough surface than Group 2. Considering the surface roughness, it would be better to make the shape completely before polymerize the resin. To finish and polish after the polymerization of resin makes less smooth surface. 3. When we use the transparent celluloid strip, minimum finishing procedures are recommended. Any polishing procedure could not recover the smooth resin surface of celluloid strip. 4. Application and polymerization of the thin layer of bonding agent on the polished surface showed the minimum surface smoothing effect.

  • PDF

Comparison of removal torques between laser-treated and SLA-treated implant surfaces in rabbit tibiae

  • Kang, Nam-Seok;Li, Lin-Jie;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.4
    • /
    • pp.302-308
    • /
    • 2014
  • PURPOSE. The purpose of this study was to compare removal torques and surface topography between laser treated and sandblasted, large-grit, acid-etched (SLA) treated implants. MATERIALS AND METHODS. Laser-treated implants (experimental group) and SLA-treated implants (control group) 8 mm in length and 3.4 mm in diameter were inserted into both sides of the tibiae of 12 rabbits. Surface analysis was accomplished using a field emission scanning electron microscope (FE-SEM; Hitachi S-4800; Japan) under ${\times}25$, ${\times}150$ and ${\times}1,000$ magnification. Surface components were analyzed using energy dispersive spectroscopy (EDS). Rabbits were sacrificed after a 6-week healing period. The removal torque was measured using the MGT-12 digital torque meter (Mark-10 Co., Copiague, NY, USA). RESULTS. In the experimental group, the surface analysis showed uniform porous structures under ${\times}25$, ${\times}150$ and ${\times}1,000$ magnification. Pore sizes in the experimental group were 20-40 mm and consisted of numerous small pores, whereas pore sizes in the control group were 0.5-2.0 mm. EDS analysis showed no significant difference between the two groups. The mean removal torque in the laser-treated and the SLA-treated implant groups were 79.4 Ncm (SD = 20.4; range 34.6-104.3 Ncm) and 52.7 Ncm (SD = 17.2; range 18.7-73.8 Ncm), respectively. The removal torque in the laser-treated surface implant group was significantly higher than that in the control group (P=.004). CONCLUSION. In this study, removal torque values were significantly higher for laser-treated surface implants than for SLA-treated surface implants.

Development of Scope with Abbe-König Prism (아베-코닉 프리즘을 이용한 스코프 개발)

  • Lee, Dong-Hee;Park, Seung-Hwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.509-517
    • /
    • 2013
  • Purpose: The purpose of this study is developing the 2.6 ${\times}$ optical scope with a Abbe-K$\ddot{o}$nig prism. Methods: First, considering the size of the effective aperture and the focal length of the objective lens, we designed an Abbe-K$\ddot{o}$nig prism. Next, we calculated the optical and geometric distances of Abbe-K$\ddot{o}$nig prism designed in this way. After allocating the focal length of the objective lens and the eyepiece lens so as to satisfy the magnification and optical effective distance of the entire system by using this calculation result, we completed the entire system by optimizing this optical system. Results: We were able to complete the optical scope of about 2.6 ${\times}$ magnification by designing an objective lens with a focal length of 63.13 mm which was composed of two pieces, an eyepiece with a focal length of 24.3 mm which was composed of four pieces, and an Abbe-K$\ddot{o}$nig prism with a face length 11.5 mm. Conclusions: We designed and fabricated an optical scope with 2.6 ${\times}$ magnification employing an Abbe-K$\ddot{o}$nig prism. Then, this system became the compacted optical system with a barrel diameter of 31 mm, characterized by an effective aperture of 12.0 mm and an effective optical barrel length of 103 mm and a resolution of 200 cycles/rad at 50% MTF criterion within the half viewing field angle of $6.42^{\circ}$.