  • The aim of this study was to determine the shaping ability of stainless-steel K file (S-S K file), nickel-titanium K file (Ni-Ti K file) and engine driven nickel-titanium file (Quantec file) in resin simulated root canal. Computed tomography was used to evaluate the change of the root canal morphology. Thirty nine resin simulated root canal were divided into four groups (A:12, B:12, C:12, D:3). Resin simulated canals were scanned by computed tomography before instrumentation (1st C-T scan). Canals were instrumented using step back preparation technique with S-S K file in group A and Ni-Ti K file in group B. Group C was prepared with engine driven Ni-Ti file. Group D was uninstrumented to compare the 1st C-T scan images with 2nd C-T scan images of root canal. Instrumented canals were again scanned using computed tomography (2nd C-T scan), and reformated images of the uninstrumented canals were compared with images of the instrumented canals. In the sections of 2mm and 6mm from the apex, Quantec file caused significantly less canal transportation than S-S K file and Ni-Ti K file (p<0.05). Quantec file produced more centered than S-S K file and Ni-Ti K file in the sections of 2mm and 4mm from the apex (p<0.05). There was no significant difference in the removed volume of canals among the each groups (p>0.05). However the removed canal volume from the apex to 5mm were significantly higher than them from 5mm to 1mm (p<0.05) in each groups. Under the conditions of this study, preparation with Quantec file was more effective and produce more appropriate canal shapes than S-S K file and Ni-Ti K file.

  • PDF

Phase Equilibria and Processing of Pb_2Sr_2(Y_{1-x}Ca_x)Cu_3O_{8+\delta} Superconductors (x=0.4-0.6) (Pb_2Sr_2(Y_{1-x}Ca_x)Cu_3O_{8+\delta}초전도체 (x=0.4-0.6)의 제조방법 및 상평형)

  • Park, Young-il;Dongwoon Jung
    • Korean Journal of Materials Research
    • /
    • v.5 no.6
    • /
    • pp.723-731
    • /
    • 1995
  • P $b_2$S $r_2$( $Y_{1-x}$ C $a_{x}$)C $u_3$ $O_{8+}$$\delta$/ samples were prepared with x=0.4~0.6 and small $\delta$. To minimize the extent of oxidative decomposition reaction which occurs during the preparation of this phase, two annealing steps were adopted : First, sintered samples of P $b_2$S $r_2$( $Y_{1-x}$ C $a_{x}$)C $u_3$ $O_{8+}$$\delta$/ are oxygenated under 100% $O_2$, which leads to a large $\delta$(e.g., $\delta$=1.8). Second, the resulting samples are deoxygenated under 0.1~1.0% $O_2$in $N_2$, lowering $\delta$ to desired values. This two-step annealing procedure minimized the extent of oxidative decomposition. However, even with the two-step annealing procedure, the oxidative decomposition of P $b_2$S $r_2$( $Y_{1-x}$ C $a_{x}$)C $u_3$ $O_{8+}$$\delta$/ cannot be completely suppressed if $\delta$ is to be reduced to maximize $T_{c}$. Electrical resistivity data show that $T_{c}$(onset) is a function of hole concentration in the Cu $O_2$layer, and the optimum hole concentration for the maximum $T_{c}$ is achieved when $Ca^{2+}$is substituted for $Y^{3+}$between 0.5 and 0.6 A $T_{c}$(onset)=80K has been observed for one such sample, and this is the highest $T_{c}$(onset) yet reported for this compound.ed for this compound.nd.

  • PDF

A Study on the Separation of Neodymium from the Simulated Solution of $U_3Si/Al$ Spent Nuclear Fuel (모의 사용후분산핵연료($U_3Si/Al$) 용해용액으로부터 네오디뮴 분리에 관한 연구)

  • Choi, Kwang Soon;Kim, Jung Suk;Han, Sun Ho;Park, Soon Dal;Park, Yeong Jae;Joe, Kih Soo;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.584-591
    • /
    • 2000
  • The separation of Nd from the simulated $U_3Si/Al$ spent fuel solution with sequential two-step anion exchange separation has been studied. To prepare the simulated $U_3Si/Al$ spent nuclear fuel, unirradiated $U_3Si/Al$ whose composition consists of small $U_3Si$ particle dispersed in an Al matrix with Al cladding was dissolved with a mixture of 4 M HCl and 10 M $HNO_3$ and 8 or 15 fission product elements were added to the dissolved solution. The trace amount of silica in the solutions was removed by evaporating to dryness with HF and the U was adsorbed on the first anion exchange resin. Neodymium can be purely isolated from the fission product elements with a methanol-nitric acid eluent using the second anion exchange resin. A large excess of Al didn't influence on the elution velocity of Nd, but reduced the eluted contents of Nd, Al, Eu, Gd, Sm and Sr, A large amount of Al was removed first from the column with 3 mL of loading solution (0.8 M $HNO_3$/99.8% MeOH) before Nd elution by the eluent [0.04 M $HNO_3$-99.8% MeOH(1:9)]. The recovery of Nd was more than 94%, regardless of Al contents. Taking the 9 to 13 mL fraction of eluate was effective to purely isolate Nd.

  • PDF

High-$T_c$ 2nd-order SQUID Gradiometer for Use in Unshielded Environments (비차폐 환경에서의 고온초전도 SQUID 2차 미분기의 특성연구)

  • 박승문;강찬석;이순걸;유권규;김인선;박용기
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.50-54
    • /
    • 2003
  • We have fabricated $∂^2$$B_{z}$ /$∂x^2$ type planar gradiometers and studied their properties in operation under various field conditions. $YBa_2$$Cu_3$$O_{7}$ film was deposited on $SrTiO_3$ (100) substrate by a pulsed laser deposition (PLD) system and patterned into a device by the photolithography with ion milling technique. The device consists of 3 pickup loops designed symmetrically Inner dimension and the width of the square side loops are 3.6 mm and 1.2 mm, respectively, and the corresponding dimensions of the center loop are 2.0 mm and 1.13 mm. The length of baseline gradiometer is 5.8 mm. Step-edge junction width is 3.0 $\mu\textrm{m}$ and the hole size of the SQUID loop is 3 $\mu\textrm{m}$ ${\times}$ 52 $\mu\textrm{m}$. The SQUID inductance is estimated to be 35 pH. The device was formed on a 20 mm ${\times}$ 10 mm substrate. We have tested the behavior of the device in various field conditions. The unshielded gradiometer was stable under extremely hostile conditions on a laboratory bench. Noise level 0.45 pT/$\textrm{cm}^2$/(equation omitted)Hz and 0.84 pT/$\textrm{cm}^2$/(equation omitted)Hz at 1 Hz for the shielded and the unshielded cases, which correspond to equivalent field noises of 150 fT/(equation omitted)Hz and 280 fT/(equation omitted)Hz, respectively. In spite of the short baseline of 5.8 mm, the high common-mode-rejection-ratio of the gradiometer, $10^3$, allowed us to successfully record magnetocardiogram of a human subject, which demonstrates the feasibility of the design in biomagnetic studies.

  • PDF

Long-baseline single-layer 2nd-order $high-T_c$ SQUID gradiometer (긴기저선을 가진 단일층 고온초전도 SQUID 2차미분기)

  • Lee Soon-Gul;Kang Chan Seok;Kim In-Seon;Kim Sang-Jae
    • Progress in Superconductivity
    • /
    • v.7 no.1
    • /
    • pp.6-10
    • /
    • 2005
  • We have studied feasibility of single-layer second-order $high-T_c$ SQUID gradiometers in magnetocardiography. We have measured human cardiomagnetic signals using a short-baseline (5.8 mm) single-layer second-order YBCO gradiometer in partially shielded environments. The gradiometer has an overall size of $17.6\;mm{\times}6\;mm$ and contains three parallel-connected pickup coils which are directly coupled to a step-edge junction SQUID. The gradiometer showed an unshielded gradient noise of $0.84\;pT/cm^2/Hz^{1/2}$ at 1 Hz, which corresponds to an equivalent field noise of $280\;fT/Hz^{1/2}$. The balancing factor was $10^3$. Based on the same design rules as the short-baseline devices, we have studied fabrication of 30 mm-long baseline gradiometers. The devices had an overall size of $70.2\;mm{\times}10.6\;mm$ with each pickup coil of $10\;mm{\times}10\;mm$ in outer size. As Josephson elements we made two types of submicron bridges, which are variable thickness bridge (VTB) and constant thickness bridge (CTB), from $3\;{\mu}m-wide$ and 300 nm-thick YBCO lines with a thin layer of Au on top by using a focused ion beam (FIB) patterning method. VTB was 300 nm wide, 200 nm thick, 30 nm long with Au removed and CTB 100 nm wide and 30 nm long. In temperature-dependent critical currents, $I_c(T)$, VTB showed an nonmetallic barrier-type behavior and CTB an SNS behavior. We believe that those characteristics are ascribed to naturally formed grain boundaries crossing the bridges.

  • PDF

Fabrication of sing1e layer $d^2B_{z}$/dxdy second-order SQUID gradiometer (단일층 $d^2B_{z}$/dxdy SQUID 2차 미분기 설계 및 제작)

  • 황윤석;박승문;이순걸;김인선;박용기
    • Progress in Superconductivity
    • /
    • v.4 no.2
    • /
    • pp.109-113
    • /
    • 2003
  • We have developed a planar-type single layer second-order $high-T_{c}$ SQUID gradiometer, which can detect the $d^2$$B_{z/}$dxdy of the second-order field gradient. This SQUID gradiometer consists of four-way 'clover-leaf' pick-up loops and is coupled directly to a 4-junction dc SQUID in such a way that the coupling polarity of the two diagonal loops is opposite to that of the other two loops. The pickup loops are intrinsically balanced for both uniform field and the 1 st-order field gradient. The $YBa_2$$Cu_3$$O_{7}$ thin film was made by pulsed laser deposition method on $SrTiO_3$ single crystal substrate and patterned by photolithography with Ar ion milling technique. Response of this gradiometer was tested for both uniform field and the 2nd-order field gradient. Details of the design, fabrication, and results will be discussed.

  • PDF

Device for Assisting Grasping Function (2nd Report : Maneuverability Evaluation)

  • Moromugi, S.;Okamoto, A.;Kim, S.H.;Tanaka, H.;Ishimatsu, T.;Koujina, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2665-2669
    • /
    • 2003
  • A wearable device to assist fingering function for disabled is developed in this study. This is the second paper to report the progress in development of this assisting device. The device is developed for a patient who suffers from cervical spinal cord injury. In the first paper, it was reported that the patient could successfully pick up several types of objects with his paralyzed fingers by using this device. As a next step, the maneuverability of the device under grasping operation is discussed in this paper. Maneuverability of the system is experimentally evaluated. The dexterity in controlling finger force is compared between the cases that non-disabled examinees operate their finger with inherent abilities and that a disabled examinee operates his finger by using the assisting device.

  • PDF

A Study on the Group Program Development for Reinforcing Family Relations of Single-mother Families (편모가족관계 강화를 위한 집단 프로그램 개발에 관한 연구)

  • Chung, Soo-Kyoung
    • Korean Journal of Social Welfare
    • /
    • v.44
    • /
    • pp.288-317
    • /
    • 2001
  • The purpose of this study is to develop the group program model for reinforcing family relations of single-mother families as one approach to family welfare service. As previous research findings about problems of single parent families were reviewed and the framework for the program development was identified, a 6 sessions group program was planned and applied to 9 single-mother families from June 2nd to July 7th. Program evaluation questionnaire, Scales measuring powerlessness and FACESIII for family relations, social support network tool, and group process recording were used for the evaluation of this program. The participants evaluated this program as very supportive, useful, and educational. The powerlessness was reduced in a statistically meaningful way before and after the program and the result was found to be maintained for 4 months in the follow-up session. The family relations according to FACES III were mostly balanced and didn't show some significant change after the termination of this program. The single mothers had little concrete supports from others, if any, had some from relatives. They rather had to give supports for the other family members and reciprocally gave and took emotional or informational supports with friends or neighbors. Based on these results, the 2 step model consisted of brief group program and long term support group was developed and the practical methods were suggested for the single-mother families with low income.

  • PDF

Effect of Tuberculin Skin Test on Ex-vivo Interferon-gamma Assay for Latent Tuberculosis Infection (투베르쿨린 검사가 결핵에 대한 체외 IFN-γ 검사 결과에 미치는 영향)

  • Lee, Jung Yeon;Choi, Hee Jin;Cho, Sang-Nae;Park, I-Nae;Oh, Yeon-Mok;Lee, Sang Do;Kim, Woo Sung;Kim, Dong Soon;Kim, Won Dong;Shim, Tae Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.4
    • /
    • pp.406-412
    • /
    • 2005
  • Background : Recently, two commercialized whole-blood assays, $QuantiFERON^{(R)}-TB$ Gold (QFT) and T $SPOT-TB^{(R)}$ (SPOT), which measure the $IFN-{\gamma}$ released in the whole blood after being incubation with mycobacterial antigens, were approved for the diagnosis of a latent tuberculosis infection (LTBI). However, there is data on whether or not the previously used PPD skin tests (TST) have any influence on the diagnostic ability of these ex-vivo $IFN-{\gamma}$ assays. Methods : Forty-six 15 year-old students who did not appear to be infected with Mycobacterium tuberculosis were enrolled in this study. The peripheral blood was collected and used for two $IFN-{\gamma}$ assays. The $IFN-{\gamma}$ assays and TST were performed at the baseline ($1^{st}$). The TST was repeated two months later ($2^{nd}$), and the $IFN-{\gamma}$ assays were repeated two ($2^{nd}$) and four months ($3^{rd}$) later only in those subjects who had negative results at the baseline in both the $IFN-{\gamma}$ assays and TST. An induration size > 10 mm was considered to be positive in the TST. Results : The mean TST value was $3.1{\pm}5.4mm$ (range: 0-20). Of the 46 subjects examined, 13 subjects (28.3%) showed positive results in the two-step TST. Nine (19.6%) were SPOT-positive and only one (2.2%) was QFT-positive. The $2^{nd}$ and $3^{rd}$ QFT were carried out in 23 and 25 all-negative subjects, respectively, and all showed negative results. The $2^{nd}$ SPOT was performed in 23 subjects and only one (4.3%) showed a weak-positive result. Conclusion : Even though there were some discrepancies in the results of the two ex-vivo $IFN-{\gamma}$ assays, it appears that their results were not influenced by a previous TST carried out in two or four months earlier.

The Level of Awareness and Practice in Prehospital Emergency Patient Assessment and Emergency Care of Paramedic in Fire Station (1급 응급구조사의 병원 전 응급환자평가와 응급처치시행에 대한 인식과 실천정도)

  • Kang, Yong-Ju;Choi, En-Sook
    • The Korean Journal of Emergency Medical Services
    • /
    • v.15 no.2
    • /
    • pp.67-84
    • /
    • 2011
  • Purpose: The aim of this study is to present the basic data for qualitative improvement of emergency care for emergency patient by paramedic in fire station by understanding the level of awareness and practice in prehospital and transfer step, and understanding the level of emergency care and improvement of clinical knowledge through hospital clinical training. Methods: The researchers explained the objective for 143 persons who completed hospital clinical training from June 2nd, 2006 to October 23rd, 2009 among paramedic in fire station. The questionnaire in this research consisted of 80 questions. In the reliability for the awareness of emergency patient assessment, cronbach's $\alpha$ was 0.95, and in the reliability for emergency care fulfillment, cronbach's $\alpha$ was 0.93. reliability for clinical knowledge improvement is cronbach's $\alpha=.95$, and reliability for emergency care fulfillment is cronbach's $\alpha=.82$. Collected data was analyzed through SPSS 18.0 statistics program for frequency, percentage, average, standard deviation, Paired t-test, t-test, Correlation Coefficient, and internal consistency reliability was analyzed by cronbach's $\alpha$. Results: 1) The paramedic awareness and practice difference for emergency patient is statistically signification for general patient assessment(t=14.159, p=.000), trauma patient assessment(t=11.288, p=.000), internal medicine patient assessment(t=10.898, p=.000), and it shows the level of practice is lower than the level of awareness. 2) The paramedic difference between the level of awareness and practice according to whether or not they have clinical career is not signification on awareness(t=3.119, p=.125), and is high on practice(t=3.119, p=.002). 3) The correlation between paramedic awareness and the level of practice shows positive correlation(r=.61, p=.000). The higher the awareness of emergency patient assessment is, the higher the level of practice is. 4) The difference between paramedic clinical knowledge improvement and the level of emergency care practice is statistically significant(t=3.351, p=.001). 5) 89.6%(128 persons) of paramedic replied hospital clinical training experiences are helpful for field activity. 92.3%(133 persons) replied they apply well for clinical knowledge learned during hospital clinical training and emergency care skills in the field. Conclusion: Paramedic in fire station must evaluate the patient's initial assessment and activate the transfer system to the emergency department. It is necessary to develop and implement the effective education program continuously. The education program should systemize currently operated hospital clinical training. emergency disease and symptoms emergency care method, and practice mainly skill education should be progressed. In the prehospital and transfer management, high quality of medical assessment is required to the emergency medical service system. Medical direction from the doctors can feedback the paramedic continuously and continuing education must be provided to the paramedic in fire station.