• Title/Summary/Keyword: ${\mu}-CT$

Search Result 258, Processing Time 0.03 seconds

Detecting and Tracking Changes of Mechanical Characteristics in the Trabecular and Cortical Bone of the Lumbar Vertebrae for an Ovariectomised Rat using In-Vivo Micro-CT and Micro Finite Element Analysis (IN-VIVO MICRO-CT 와 미세 유한요소법를 이용한 쥐의 골다공증 해면골과 피질골의 구조적 특성 추적관찰 및 기계적 특성 분석)

  • Ko C.Y.;Woo D.G.;Kim H.S.;Lee B.L.;Tack G.R.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.892-895
    • /
    • 2005
  • This study investigated changes of mechanical characteristics in the trabecular and cortical bone of the lumbar vertebrae of the ovariectomised(OVX) rat. In previous researches, there were many studies for morphology of osteoporotic bones based on Micro-CT (Micro - Computed Tomography). However, there were few studies for detecting and tracking changes of mechanical characteristics in the trabecular bone and cortical bone of the lumbar vertebrae for the OVX rat. For this study, one female Sprague-Dawley rat was used: an OVX rat. The 4th lumbar of the OVX rat was utilized as a specimen. Detecting and tracking changes of mechanical characteristics could be investigated in the trabecular and cortical bone of the lumbar vertebrae for an OVX rat using In-vivo Micro-CT. An OVX rat was scanned at week 0 (just before surgery), at week 4, and week 8 after surgery. Micro finite element(${\mu}\;FE$) analysis was used to investigate mechanical characteristics in the trabecular and cortical bone of the lumbar vertebrae for an OVX rat.

  • PDF

Quantification of Microstructures in Mice Alveolar Bone using Micro-computed tomography (${\mu}CT$)

  • Park, Hae-Ryoung;Kim, Hyun-Jin;Park, Byung-Ju
    • International Journal of Oral Biology
    • /
    • v.38 no.3
    • /
    • pp.87-92
    • /
    • 2013
  • Periodontal inflammation increases the risk of tooth loss, particularly in cases where there is an associated loss of alveolar bone and periodontal ligament (PDL). Histological and morphometric evaluation of periodontal inflammation is difficult. Especially, the lengths of the periodontal ligament and interdental alveolar bone space have not been quantified. A quantitative imaging procedure applicable to an animal model would be an important clinical study. The purpose of this study was to quantify the loss of alveolar bone and periodontal ligament by evaluation with micro-computed tomography (micro-CT). Another purpose was to investigate differences in infections with systemic E. coli LPS and TNF-${\alpha}$ on E. coli lipopolysaccharide (LPS) in loss of alveolar bone and periodontal ligament model on mice. This study showed that linear measurements of alveolar bone loss were represented with an increasing trend of the periodontal ligament length and interdental alveolar process space. The effects of systemic E. coli LPS and TNF-${\alpha}$ on an E. coli LPS-induced periodontitis mice model were investigated in this research. Loss of periodontal ligament and alveolar bone were evaluated by micro-computed tomography (micro-CT) and calculated by the two- and three dimensional microstructure morphometric parameters. Also, there was a significantly increasing trend of the interdental alveolar process space in E. coli LPS and TNF-${\alpha}$ on E. coli LPS compared to PBS. And E. coli LPS and TNF-${\alpha}$ on E. coli LPS had a slightly increasing trend of the periodontal ligament length. The increasing trend of TNF-${\alpha}$ on the LPS-induced mice model in this experiment supports the previous studies on the contribution of periodontal diseases in the pathogenesis of systemic diseases. Also, our findings offer a unique model for the study of the role of LPS-induced TNF-${\alpha}$ in systemic and chronic local inflammatory processes and inflammatory diseases. In this study, we performed rapidly quantification of the periodontal inflammatory processes and periodontal bone loss using micro-computed tomography (micro-CT) in mice.

Effects of Kyejiinsam-tang in MIA-Induced Osteoarthritis Rats (계지인삼탕(桂枝人蔘湯)이 MIA로 유도된 골관절염 유발 Rat에 미치는 영향)

  • An, Soon-Sun;Heo, Dong-Seok
    • The Journal of Korean Medicine
    • /
    • v.34 no.3
    • /
    • pp.69-85
    • /
    • 2013
  • Objectives: This study investigated the anti-osteoarthritic effects of Kyejiinsam-tang (hereinafter referred to KIT) on the monosodium iodoacetate (MIA)-induced osteoarthritis rats. Methods: Anti-oxidative effects of KIT were measured by scavenging activities of DPPH, reactive oxygen species (ROS) and nitric oxide (NO). Scavenging activities of anti-oxidation in lipopolysaccharide (LPS)-treated RAW 264.7 cells were also measured for inhibitory effects against the production of inflammatory mediators (tumor necrosis factor-${\alpha}$, interleukin-$1{\beta}$, interleukin-6). Osteoarthritis was induced in rats by injecting MIA in the knee joint. Rats were divided into a total of 4 groups (n=6). The normal group were not treated at all without inducing osteoarthritis whereas the control group were induced for osteoarthritis by MIA and oral medicated physiological saline per day. The positive comparison group was injected with MIA and after 7 days, 2 mg/kg of Indomethacin. The experimental group was injected with MIA and after 7 days was medicated with 34 mg/kg of KIT. Indomethacin and KIT were orally-medicated for each substance a total of 4 weeks, once per day. Weight-bearing on hind legs was measured every week after MIA injection. At the end of the experiment (5 weeks after MIA injection), micro CT (computed tomography)-arthrography and histopathological examinations on the articular structures of knee joint were performed. The effect on inflammatory cytokines and immunological cells in synovial fluid was measured. Volume of cartilage was measured by micro CT-arthrography. Injury to synovial tissue was measured by H & E (hematoxylin and eosin), Safranin-O immunofluorescence. Results: 1. Cytotoxicity against hFCs was insignificant. 2. KIT showed the potent full term for DPPH. 1. NO was significantly reduced by KIT (at 100, $200{\mu}g/m{\ell}$) and ROS was also reduced, but not significantly, by KIT (at $200{\mu}g/m{\ell}$). 2. IL-6 and IL-$1{\beta}$ were significantly reduced by KIT (at 100, $200{\mu}g/m{\ell}$) and TNF-${\alpha}$ was also reduced, but not significantly, by KIT (at $200{\mu}g/m{\ell}$). 1. In hind legs weight-bearing measurement, level of weight increased. 2. Functions of liver and kidney were not affected. 3. IL-$1{\beta}$ was significantly reduced and TNF-${\alpha}$, IL-6 were also reduced but not significantly. 4. PGE2 (prostaglandin E2), LTB4 (leukotriene B4) were significantly reduced in the KIT group. 5. MMP-9 (matrix metalloproteinase-9), TIMP-1 (tissue inhibitor of metalloproteinases-1) and Osteocalcin were significantly reduced in the KIT group. 6. Destruction of cartilage on micro CT arthrography was reduced but had no significant differences. 7. Histopathologically, injury to synovial membrane of the KIT group was decreased and proteoglycan content of KIT group was increased. Conclusions: According to this study, Kyejiinsam-tang has inhibiting effect on the progression of arthritis in MIA-induced osteoarthritis rat. Kyejiinsam-tang has anti-oxidants and anti-inflammation effects, and is related to inhibiting the activity of inflammatory cytokine and injury of volume in cartilage.

Comparison of Dose Depending on the Position when Shooting Panorama and CBCT (CBCT와 panorama 촬영시 위치에 따른 선량 비교)

  • Jeong, Cheonsoo;Kim, Chongyeal
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.175-179
    • /
    • 2013
  • To find out the appropriate defensive measures for protectors and radiation workers in rotating radiation generating devices such as CBCT and panorama, irradiation dose depending on the position was compared and analyzed. The devices such as panorama DP-90-P PAX-500 (Vatech, Korea) and CBCT DCT-90-P IMPLAGRAPHY Dental CT system (Vatech, Korea) were used. As irradiation dose measuring instruments, Ion chamber model 2026 and Reader 20X5-60E were used. The exposure conditions were set as the factor used in the clinical trial. The result of the experiment showed that panorama was the highest, 81${\mu}R$, at point A where the test starts first and the lowest, 53${\mu}R$, at point D where the test ends. In case of CBCT, it was the highest, 1,021${\mu}R$, at point D where the test ends and was measured as the highest, 809.67${\mu}R$, at point A where the test starts. If protectors and radiation workers are forced to examine a patient holding him, they should be positioned in the middle of the point where X ray tube starts to rotate and the point where it ends to avoid the position where radiation dose is the most. And due to the nature of equipment, it will be the safest for them to stand at the opposite side of the machine and to uphold it from the rear rather than upholding it from the side of a patient and they should wear appropriate the protection gear.

Development of Electric Instrument of Current and Leakage Current based on NI-9223 and Current Prove (NI-9223과 전류프로브를 이용한 전류 및 누설전류 측정장치 개발)

  • Kim, Sung-Chul;Kim, Un-Sul
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.48-53
    • /
    • 2012
  • This paper is purposed to develop portable electric instrument to select NI-9223(National instrument comp.) and clamp meter(HIOKI comp.), which can be used in developing electric instrument, to detect leakage current(ZCT) and current(CT) signals. In this paper, The electric instrument that can interface with current and leakage current instrument(HIOKI 9283), is developed by NI-9223 of NI comp.. HIOKI clamp meter can measure current signals certainly by high-sensitivity of 10 ${\mu}A$ resolution(leakage current : at 10 mA range) and current 1~200A range. The NI-9223 use four 16-bit analog-to-digital converters(ADCs) for true simultaneous sampling at up to 1 MS/s per channel. NI-9223 can synchronize all analog input modules installed in the same chassis to share the same start clock and/or sample clocks. The monitoring program is developed by SignalExpress of LabVIEW. The monitoring program are developed to analyze at simultaneous sampling on electrical signals such as leakage current(ZCT) and current(CT). The developed system verification tests were conducted, and portable electric instrument can be used in place which requires analysis of the actual electrical signal.

A Study of Heterogeneity Corrections for Radiation Treatment Planning (방사선 치료계획 시 불균질 보정에 관한 고찰)

  • Lee, Je-Hee;Kim, Bo-Gyum;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.89-96
    • /
    • 2006
  • Purpose: To study effectiveness of heterogeneity correction of internal-body inhomogeneities and patient positioning immobilizers in dose calculation, using images obtained from CT-Simulator. Materials and Methods: A water phantom($250{\times}250{\times}250mm^3$) was fabricated and, to simulate various inhomogeneity, 1) bone 2) metal 3) contrast media 4) immobilization devices(Head holder/pillow/Vac-lok) were inserted in it. And then, CT scans were peformed. The CT-images were input to Radiation Treatment Planning System(RTPS) and the MUs, to give 100 cGy at 10 cm depth with isocentric standard setup(Field Size=$10{\times}10cm^2$, SAD=100 cm), were calculated for various energies(4, 6, 10 MV X-ray). The calculated MUs based on various CT-images of inhomogeneities were compared and analyzed. Results: Heterogeneity correction factors were compared for different materials. The correction factors were $2.7{\sim}5.3%$ for bone, $2.7{\sim}3.8%$ for metal materials, $0.9{\sim}2.3%$ for contrast media, $0.9{\sim}2.3%$ for Head-holder, $3.5{\sim}6.9%$ for Head holder+pillow, and $0.9{\sim}1.5%$ for Vac-lok. Conclusion: It is revealed that the heterogeneity correction factor calculated from internal-body inhomogeneities have various values and have no consistency. and with increasing number of beam ports, the differences can be reduced to under 1%, so, it can be disregarded. On the other hand, heterogeneity correction from immobilizers must be regarded enough to minimize inaccuracy of dose calculation.

  • PDF

Anti-inflammatory Effect of Methanol Extract from Safflower Seeds

  • Kim, Hyun-Jin
    • International Journal of Oral Biology
    • /
    • v.41 no.2
    • /
    • pp.83-88
    • /
    • 2016
  • Periodontitis is an inflammatory disease, which destroys the connective tissue and the alveolar bone. Recently, it has been suggested that the effect of natural substances could be induced into an anti-inflammatory environment. However, the effect of Safflower seed extract (SAF-M) associated with periodontitis has not been investigated yet. Therefore, the purpose of this study was to assess the anti-inflammatory effects of SAF-M. Cytotoxicity was assessed through MTS analysis using hGF and hPDL cells. Periodontitis was induced by injecting LPS into gingival tissue on the maxillary molars of rats ($45{\mu}g$ LPS/one time, 3 times a week for 3 weeks). SAF-M was administered daily at 30 mg/kg and 100 mg/kg. Alveolar bone resorption was evaluated through the micro-CT. hGF and hPDL cells showed differential cytotoxicity in response to SAF-M at 5 mg/ml and 1 mg/ml concentrations. Micro-CT showed reduction of the alveolar bone resorption in the SAF-M treatment group. These results suggested that SAF-M is a potential therapeutic agent for periodontitis.

Intergeneric Transfer of Nitrogen Fixation Genes from Rhizobium leguminosarum by RP4::Mu cts (RP4::Mu cts에 의한 Rhizobium leguminosarum 질소고정 유전자의 속간전달에 관한 연구)

  • 허연주;이영록
    • Korean Journal of Microbiology
    • /
    • v.24 no.3
    • /
    • pp.211-220
    • /
    • 1986
  • Nitrogen fixation (nif) genes of Rhizobium leguminosarum were transferred to nif Klebsiella pneumoniae and E. coli by conjugation after partial heat induction of $RP_4$ :: Mu cts in Rhizobium $R^+$ transconjugant, and the hybrid plasmids in the transconjugant strains were isolated and characterized. In order to transfer the nif genes from Rhizobium, the hybrid plasmid $RP_4$ :: Mu cts was transferred by conjugation from E. coil to the symbiotic nitrogen fixer, R. leguminosarum. After stabillity test, the $RP_4$ :: Mu cts in Rhixobium $R^+$ transconjugant was subjected to partial heat induction by culturing it statically at $38^{\circ}C$ for 16 hours, and then conjugated with the nif defective mutant strains of K. pneumoniae or nif mutant strains of E. coli having whole nif gene plasmid. Recombinant strains of K. pneumoniae, which could grow in a N-free medium and exhibit the nitrogenase activity were selected. However, in the case of E. coli, they could grow well in a NA medium containing antibiotices, but hardly frow in a N-free medium. The hybrid plasmids in these transconjugal strains were isolated by gel electrophoresis and compared their molecular sizes.

  • PDF

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF

Study on the calibration phantom and metal artifacts using virtual monochromatic images from dual energy CT (듀얼 에너지 CT의 가상 단색 영상을 이용한 영상 교정 팬텀과 금속 인공음영에 관한 연구)

  • Lee, Jun seong;Lee, Seung hoon;Park, Ju gyung;Lee, Sun young;Kim, Jin ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.77-84
    • /
    • 2017
  • Purpose: To evaluate the image quality improvement and dosimetric effects on virtual monochromatic images of a Dual Source-Dual Energy CT(DS-DECT) for radiotherapy planning. Materials and Methods: Dual energy(80/Sn 140 kVp) and single energy(120 kVp) scans were obtained with dual source CT scanner. Virtual monochromatic images were reconstructed at 40-140 keV for the catphan phantom study. The solid water-equivalent phantom for dosimetry performs an analytical calculation, which is implemented in TPS, of a 10 MV, $10{\times}10cm^2$ photon beam incident into the solid phantom with the existence of stainless steel. The dose profiles along the central axis at depths were discussed. The dosimetric consequences in computed treatment plans were evaluated based on polychromatic images at 120 kVp. Results: The magnitude of differences was large at lower monochromatic energy levels. The measurements at over 70 keV shows stable HU for polystyrene, acrylic. For CT to ED conversion curve, the shape of the curve at 120 kVp was close to that at 80 keV. 105 keV virtual monochromatic images were more successful than other energies at reducing streak artifacts, which some residual artifacts remained in the corrected image. The dose-calculation variations in radiotherapy treatment planning do not exceed ${\pm}0.7%$. Conclusion: Radiation doses with dual energy CT imaging can be lower than those with single energy CT imaging. The virtual monochromatic images were useful for the revision of CT number, which can be improved for target coverage and electron densities distribution.

  • PDF