• Title/Summary/Keyword: ${\gamma}-rays$

Search Result 594, Processing Time 0.021 seconds

The Characteristics for BNCT facility in Hanaro Reactor

  • Soheigh Suh;Lee, Dong-Han;Ji, Young-Hoon;Lee, Dong-Hoon;Yoo, Seong-Yul;Rhee, Chang-Hun;Rhee, Soo-Yong;Jun, Byung-Jin
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.161-163
    • /
    • 2002
  • The BNCT(Boron Neutron Capture Therapy) facility has been developed in Hanaro(High-flux Advanced Neutron Application Reactor), a research reactor of Korea Atomic Energy Research Institute. A typical tangenial beam port is utilized with this BNCT facility. Thermal neutrons can be penetrated within the limits of the possible maximum instead of being filtered fast neutrons and gamma rays as much as possible using the silicon and bismuth single crystals. In addition to, the liquid nitrogen (LN$_2$) is used to cool down the silicon and bismuth single crystals for the increase of the penetrated thermal neutron flux. Neutron beams for BNCT are shielded using the water shutter. The water shutter was designed and manufactured not to interfere with any other subsystem of Hanaro when the BNCT facility is operated. Also, it is replaced with conventional beam port plug in order to cut off helium gas leakage in the beam port. A circular collimator, composed of $\^$6/Li$_2$CO$_3$ and polyethylene compounds, is installed at the irradiation position. The measured neutron flux with 24 MW reactor power using the Au-198 activation analysis method is 8.3${\times}$10$\^$8/ n/cm$^2$ s at the collimator, exit point of neutron beams. Flatness of neutron beams is proven to ${\pm}$ 6.8% at 97 mm collimator. According to the result of acceptance tests of the water shutter, the filling time of water is about 190 seconds and drainage time of it is about 270 seconds. The radiation leakages in the irradiation room are analyzed to near the background level for neutron and 12 mSv/hr in the maximum for gamma by using BF$_3$ proportional counter and GM counter respectively. Therefore, it is verified that the neutron beams from BNCT facility in Hanaro will be enough to utilize for the purpose of clinical and pre-clinical experiment.

  • PDF

Study on the Mating Ability and Competitiveness of the Radiation Irradiated Males of Rice Stem Borer (Chile suppressalis Walker) (방사선 조사 이화명나방의 교미능력 및 경쟁력에 관한 연구)

  • Hyun Jai Sun;Ryu Joon;Chung Kyu Hoi;Kwon Shin Han
    • Korean journal of applied entomology
    • /
    • v.11 no.1
    • /
    • pp.25-30
    • /
    • 1972
  • Five to seven day old pupae were irradiated with gamma rays, the mating ability, and competability of the irradiated males were examined. The results obtained are summarized as follows: 1. There is no difference in percentage of males that mated, nor in the maximum number of matings of the males, when individual matings were made, and fresh females were provided every day for his life time. 2. The average days for the first mating of the emerged were 1.5 days for the control, and 2.4 days for the males irradiated with 25 and 30 Krad. The average days between first and second mating were 3.0 days for the irradiated males, and 1.3 days for the control. 3. The average matings of a male were 1.2 and 2.5 times when 5 and 10 females were provided to a normal male respectively. No significant different in average numbers of mated female per male were observed between the normal and irradiated males. 4. To test the mating competitiveness of the irradiated and normal males (1:0, 1:1, 2:1, 1:2, 5:1, 1:5, 0:1) were confined together with five virgin females. The greatest reduction in hatching percentage was found with 5 : 1 : 1 (30 Krad) where $26.6\%$ was hatched.5, The results showed that the irradiated males were not fully competitive with normal males, but if the reduced number of eggs produced by the female mated with irradiated male is considered, it might be used sterile male techniques in rice stem borer control.

  • PDF

Induction of Radiation Adaptive Response in Lymphocytes of patients Undergoing Bone Scintigraphy (골 신티그라피를 시행한 환자의 림프구에서 방사선 적응반응의 유도에 관한 연구)

  • Min, Jung-Jun;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.2
    • /
    • pp.172-177
    • /
    • 1999
  • Purpose: The purpose of this study was to ascertain whether radiation adaptive response could be induced by Tc-99m-methylene diphosphonate (Tc-99m-MDP) in peripheral lymphocytes of patients undergoing bone scintigraphy. Materials and Methods: Lymphocytes from 22 patients (6 males, 16 females, mean age $50{\pm}14$ years) were collected before and after bone scintigraphy using 740 MBq Tc-99m-MDP Lymphocytes from 10 controls (6 males, 4 females, mean age $43{\pm}7$ years) were also collected. They were exposed to challenge dose of 2 Gy gamma rays using a cell irradiator. Number of ring-form and dicentric chromosomes per 600 cells (chromosomal aberrations) was counted under the light microscope. Results: Chromosomal aberrations in patients before bone scintigraphy ($385.1{\pm}30.5$) was not different from that of controls ($367.8{\pm}36.6$). However, chromosomal aberrations in patients after bone scintigraphy was significantly decreased to $192.6{\pm}22.1$ (p=0.0001). Conclusion: Low dose gamma-irradiation by Tc-99m-MDP used for bone scintigraphy induces a cytogenetic adaptive response in peripheral lymphocytes.

  • PDF

The Effects of Diagnostic Radiology Image on Radiopharmaceutical Testing (방사성의약품 검사 시 진단(CT)영상에 미치는 영향)

  • Lee, Eun-Hye;Lee, Ye-Seul;Kim, Gha-Jung;Choi, Jun-Gu
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.113-117
    • /
    • 2010
  • This research attempts to qualitatively evaluate the intensity change by radiopharmaceuticals and obtain computed tomography using phantom injected with various nuclide. Cylindrical phantom is used for comparing and analysing the effect on diagnosis image during radiopharmaceuticals inspection. Inside of the phantom, water is injected and computed tomography image is scanned. During nuclear medicine invitro, frequently used radiopharmaceuticals, $^{99m}TcO_4$ 20 mCi and $^{18}F$ 14 mCi, is diluted in the water phantom and scanned in the same method. Traverse image obtained by CT scan is divided into six traverse image in the same slice of each scanned image. CT-number(HU) value of 10 measuring point is measured in 2 cm interval based on the center of the phantom. Measured HU value, based on the water phantom, is compared with the image after injecting $^{99m}TcO_4$ and $^{18}F$. Average scale of water is 2.8~1.6 HU, $^{99m}TcO_4$ is 3.0~1.6 HU and $^{18}F$ is 1.2~0 HU. Average of water is $2.3{\pm}0.17$ HU, $^{99m}TcO_4$ is $2.2{\pm}0.85$ HU and F-18 is $0.7{\pm}0.95$ HU. Based on water, reduced value of about 0.1 HU and about 0.5 HU is acquired from $^{99m}TcO_4$ and F-18. Radionuclide used in nuclear medicine inspection utilizes 100~200 KeV energy and obtains image through scintillation camera and PET-CT utilizes 511 KeV positron annihilation energy to obtain image. What we learned from this research is that gamma rays from these energies used in CT scan for diagnosis purpose or radioactive therapy plan can change the intensity of the image. The nuclear medicine inspection for reducing the effect of emitted gamma ray diagnosis image should be obtained after a period of time considering half-life which would be reduced distortion or changed in image.

  • PDF

Exploitation of the Dose/Time-Response Relationship for a New Measure of DNA Repari in the Single-Cell Gel Electrophoresis (Comet) Assay

  • Kim, Byung-Soo;Edler, Lutz;Park, Jin-Joo;Fournier, Dietrich Von;Haase, Wulf;Sautter-Bihl, Mare-Luise;Hagmuller, Egbert;Gotzes, Florian;Thielmann, Heinz Walter
    • Toxicological Research
    • /
    • v.20 no.2
    • /
    • pp.89-100
    • /
    • 2004
  • The comet assay (also called the single-cell gel electrophoresis assay) has been widely used for detecting DNA damage and repair in individual cells. Since the conventional methods of evaluating comet assay data using frequency statistics are unsatisfactory we developed a new quantitative measure of DNA damage/repair that is based on all information residing in the dose/time-response curves of a comet experiment. Blood samples were taken from 25 breast cancer patients before undergoing radiotherapy. The comet assay was performed under alkaline conditions using isolated lymphocytes. Tail DNA, tail length, tail moment and tail inertia of the comet were measured for each patient at four doses of $\gamma$-rays (0, 2, 4 and 8 Gy) and at four time points after irradiation (0, 10, 20 and 30 min) using 100 cells each. The resulting three-dimensional dose-time response surface was modeled by multiple regression, and the second derivative, termed 2D, on dose and time was determined. A software module was programmed in SAS/AF to compute 2D values. We applied the new method successfully to data obtained from cancer patients to be assessed for their radiation sensitivity. We computed the 2D values for the four damage measures, i.e., tail moment, tail length, tail DNA and tail inertia, and examined the pairwise correlation coefficients of 2D both on the log scale and the unlogged scale. 2D values based on tail moment and tail DNA showed a high correlation and, therefore, these two damage measures can be used interchangeably as far as DNA repair is concerned. 2D values based on tail inertia have a correlation profile different from the other 2D values which may reflect different facets of DNA damage/repair. Using the dose-time response surface, other statistical models, e.g., the proportional hazards model, become applicable for data analysis. The 2D approach can be applied to all DNA repair measures, Le., tail moment, tail length, tail DNA and tail inertia, and appears to be superior to conventional evaluation methods as it integrates all data of the dose/time-response curves of a comet assay.

Detection of Irradiated Agricultural Products by Thermoluminescence(TL) (Thermoluminescence(TL)를 이용한 농산물의 방사선 조사유무 확인)

  • Woo, Si-Ho;Yi, Sang-Duk;Yang, Jae-Seung
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.525-530
    • /
    • 2000
  • A study was carried out to establish the detection method of irradiated agricultural products cultivated in Korea by Thermoluminscece(TL). Samples were irradiated using Co-60 gamma rays at various doses(0.05, 0.1, 0.2, 0.3 and 0.5 kGy). After irradiation, separated minerals of the samples measured by TL. TL intensity increased with increasing doses and the irradiated samples were higher than the non-irradiated samples. TL first and second glow curves showed maximum TL temperature point at $176.16{\sim}190.08^{\circ}C$ and $143.84{\sim}146.56^{\circ}C$, respectively. All the irradiated samples can be classified correctly by the shape of the glow curve and the glow curve ratio. Correlation coefficients of ginger, carrot, potato and sweet potato were 0.9968, 0.8522, 0.9612 and 0.9071, respectively, that showed very high correlation between irradiation dose and TL intensity. Therefore, these results suggest that TL measurement is an useful detection method for irradiated agricultural products.

  • PDF

A Study on Non-proportionality of Phoswich Detector Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 Phoswich 계측기의 비선형성 연구)

  • Kim, Jae-Cheon;Kim, Jong-Kyung;Kim, Soon-Young;Kim, Yong-Kyun;Lee, Woo-Gyo
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.263-268
    • /
    • 2004
  • Using the Monte Carlo simulation, a study on the lion-proportionality of the prototype phoswich detector with $2'{\times}2'$ CSI(Tl) and plastic scintillator, which was made by KAERI, has been carried. The defector response functions (DRFs) calculated by simulations were compared with the experimental measurement on the $^{137}Cs\;and\;^{60}Co$. To precisely simulate the DRF for the phoswich, the CSI(Tl) non-proportionality was calculated using the electron response and the simplified electron cascade sequence for treating the photoelectric absorption event. The resulting DRFs of $^{137}Cs\;and\;^{60}Co$ sources obtained by simulations were compared with experiments for verification. For $^{137}Cs$, gamma-ray responses simulated by MCNP5 are generally good agreement with the measured ones. But the DRF of $^{60}Co$ does not match well with the results of experiment in the energy region below second peak due to the coincidence effect of two gamma-rays (1.17 MeV and 1.33 MeV). Through the analysis of the non-proportionality of CsI(Tl) in the prototype phoswich, the improved DRFs considering non-proportionality were produced and the simulation results were verified using the experimental measurements. However, to more precisely reproduce the DRF for the phoswich, further studies in relation to the electron channeling effect and the Doppler broadening effect of a scintillator are still needed as well as considering that effect of the transfer contribution.

Effects of Radiation on the Chromosomes in Bone Marrow Cells of the Mouse (방사선(放射線)이 생쥐 골수세포(骨髓細胞)의 염색체(染色體)에 미치는 향영(響影))

  • Kim, Yung-Jin;Kim, Jong-Bong
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.2
    • /
    • pp.137-143
    • /
    • 1985
  • To study the relationships among the frequency of chromosomal aberration induced by radiation, mouse age at the time of exposure and elapsed time after the irradiation, the 40, 150 and 300 day old mice were irradiated by gamma rays to 200 rad of acute whole body doses. The bone marrow chromosomes were observed in 8 experimental groups such as 1, 2, 3, 4, 8, 16, 30, 60 and 90 days after irradiation. In the 40 day old mice the frequencies of cell with chromosomal aberration were 53.0%, 21.5%, 8.4%, 8.4%, 12.0%, 8.0%, 7.0% and 5.0% in 8 experimental groups, in the 150 day old mice 32.5%, 12.1%, 10.5%, 12.8%, 0.03%, 9.7%, 7.0% and 4.2%. The 300 day old mice showed that the frequencies of cells with chromosomal aberration were 27.7%, 13.6%, 9.0%, 9.3%, 13.3%, 14.4%, 7.5% and 9.5% in each experimental group. There were tendencies that the frequencies of cell with chromosomal aberration were higher in the young mice than the old ones within 2 days after the irradiation but in the old mice than the young ones after 4 days.

  • PDF

Fabrication of $Li_2B_4O_7$ Series Single-Crystal TLDs and their TL properties ($Li_2B_4O_7$ 계열 단결정 TLD 소자의 제작과 특성)

  • Park, Myeong-Hwan;Park, Kang-Soo
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • High-quality single crystals of pure $Li_2B_4O_7$ as well as $Li_2B_4O_7$ doped with Cu, Mn and Mg impurities (1.0mol%, respectively) have been grown from the melt of $Li_2CO_3+2B_2O_3$ by Czochralski method in platinum crucibles. To study the thermoluminescent properties, $Li_2B_4O_7$ series single crystal TLDs were made by cutting in the size of $4{\times}5{\times}1\;mm^3$. The glow curves show two or three peaks which can be easily deconvoluted. It is observed that room temperature($20{\sim}30^{\circ}C$) fadings of the dosimetric peaks of $Li_2B_4O_7$ series single crystal TLDs were about 10 % for 30 days. The relative photon energy response for $Li_2B_4O_7$ series single crystal TLDs were about 85 % when the responses were normalized to that measured with $^{60}Co\;(1.25\;MeV)\;{\gamma}-rays$. The measured data are in a good agreement with theoretical ones. The $Li_2B_4O_7$ series single crystal TLDs fabricated in this work can be used for monitoring personal and environmental radioactivity.

  • PDF

Selection of Mutant Lines with Useful Traits by Irradiation of Proton Ion Beams and Gamma Ray in Rapeseed (Brassica napus L.) (양성자 및 감마선처리에 의한 유채 유용형질의 변이계통 선발)

  • Kim, Jun-Su;Eun, Jong-Seon
    • Korean Journal of Breeding Science
    • /
    • v.43 no.2
    • /
    • pp.145-153
    • /
    • 2011
  • To develop new varieties of rapeseed (Brassica napus L.), the seeds of three varieties 'Naehan', 'Tammi', and 'Halla' were treated with proton ion beams and gamma rays (0~2,000 Gy), and then the characteristics of the mutants induced were examined up to $M_5$ generation to select the lines with fixed useful traits. In $M_5$ generation, we had selected several lines that were highly fixed for some useful traits such as plant height, maturity and flower size; one line with both earlier maturity and shorter stem than wild type, one line with only earlier maturity, two lines with shorter stem, one line with large flower, and one line with chlorophyll mutation. Among them, NP600-1-1-198-2 (induced from variety 'Naehan' was treated with proton ion beams 600 Gy) was superior for its distinction from the original variety, uniformity and stability. The unique characteristics of NP600-1-1-198-2 were dark green leaves, green stem, yellow flower, and black seed coat. Its flowering date was April 14, eight days earlier than its original variety, while seed maturity date was June 16 (five days earlier) and plant height 105 cm (shorter by 10 cm). NP600-1-1-198-2 has 52 silique per panicle, 6.2 cm silique length, 23 seeds per silique, 4.2 g per 1000 seeds and 45.9% oil content. The seed oil contained 67.8% of oleic acid, 16.7% of linoleic acid and 7.3% of linolenic acid but no erucic acid.