• Title/Summary/Keyword: ${\gamma}-rays$

Search Result 606, Processing Time 0.031 seconds

Radiation shielding properties of weathered soils: Influence of the chemical composition and granulometric fractions

  • Pires, Luiz F.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3470-3477
    • /
    • 2022
  • Soils are porous materials with high shielding capability to attenuate gamma and X-rays. The disposal of radionuclides throughout the soil profile can expose the living organisms to ionizing radiation. Thus, studies aiming to analyze the shielding properties of the soils are of particular interest for radiation shielding. Investigations on evaluating the shielding capabilities of highly weathered soils are still scarce, meaning that additional research is necessary to check their efficiency to attenuate radiation. In this study, the radiation shielding properties of contrasting soils were evaluated. The radiation interaction parameters assessed were attenuation coefficients, mean free path, and half- and tenth-value layers. At low photon energies, the photoelectric absorption contribution to the attenuation coefficient predominated, while at intermediate and high photon energies, the incoherent scattering and pair production were the dominant effects. Soils with the highest densities presented the best shielding properties, regardless of their chemical compositions. Increases in the attenuation coefficient and decreases in shielding parameters of the soils were associated with increases in clay, Fe2O3, Al2O3, and TiO2 amounts. In addition, this paper provides a comprehensive description of the shielding properties of weathered soils showing the importance of their granulometric fractions and oxides to the attenuation of the radiation.

Study on the PET image quality according to various scintillation detectors based on the Monte Carlo simulation

  • Eunsoo Kim;Chanrok Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.129-132
    • /
    • 2023
  • Purpose: Positron emisson tomography (PET) is a crucial medical imaging scanner for the detection of cancer lesions. In order to maintain the improved image quality, it is crucial to apply detectors of superior performance. Therefore, the purpose of this study was to compare PET image quality using Monte Carlo simulation based on the detector materials of BGO, LSO, and LuAP. Materials and Methods: The Geant4 Application for Tomographic Emission (GATE) was used to design the PET detector. Scintillations with BGO, LSO and LuAP were modelled, with a size of 3.95 × 5.3 mm2 (width × height) and 25.0 mm (thickness). The PET detector consisted of 34 blocks per ring and a total of 4 rings. A line source of 1 MBq was modelled and acquired with a radius of 1 mm and length of 20 mm for 20 seconds. The acquired image was reconstructed maximum likelihood expectation maximization with 2 iteration and 10 subsets. The count comparison was carried out. Results and Discussion: The highest true, random, and scatter counts were obtained from the BGO scintillation detector compared to LSO and LuAP. Conclusion: The BGO scintillation detector material indicated excellent performance in terms of detection of gamma rays from emitted PET phantom.

Effect of Gamma Irradiation on the Physical Properties of Alginic Acid and λ-Carrageenan (감마선 조사가 알긴산과 카라기난의 물리적 특성에 미치는 영향)

  • Song, Eu-Jin;Lee, So-Young;Kim, Koth-Bong-Woo-Ri;Park, Jin-Gyu;Kim, Jae-Hun;Lee, Ju-Woon;Byun, Myung-Woo;Ahn, Dong-Hyun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.36 no.7
    • /
    • pp.902-907
    • /
    • 2007
  • This study was carried out to find the effect of ${\gamma}$ -irradiation on the physical properties of alginic acid and ${\lambda}$-carrageenan solution. Alginic acid and ${\lambda}$-carrageenan aqueous solution were irradiated with $Co^{60}$ ${\gamma}$ -rays in dosages ranging from 3 to 100 kGy, and then the molecular weight, viscosity and color were measured. The molecular weight of alginic acid and ${\lambda}$-carrageenan solution were decreased as the ${\gamma}$ -irradiation dosage increased. In addition, the viscosity of irradiated alginic acid and ${\lambda}$-carrageenan solution were decreased depending upon the ${\gamma}$ -irradiation dosage, too. The high dosage irradiated alginic acid and ${\lambda}$-carrageenan solution's color were changed to yellow. These results suggest that low dosage of ${\gamma}$ -irradiation from 3 to 20 kGy is a very effective method for producing low-molecular alginic acid and ${\lambda}$-carrageenan.

Methodologic Aspect of LINAC-based Stereotactic Radiosurgery (선형가속기 기반 뇌정위 방사선 수술기법)

  • Choi, Tae Jin
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.127-137
    • /
    • 2012
  • A conversing beam is firstly designed for radiosurgery by a neurosugern Lars Leksell in 1949 with orthogonal x-rays tube moving through horizontal moving arc to focusing the beam at target center. After 2 decades he composits 201 source of the Co-60 for gamma knife which beams focused at locus. Sveral linac-based stereotactic radiosurgery using the circular collimated beam which size range for 0.4~4.0 cm in a diameter by non-coplanar multiarc have been developed over the decades. The irregular lesions can be treated by superimposing with several spherical shots of radiation over the tumour volume. Linac based techniques include the use of between 4 and 11 non-co-planar arcs and a dynamic rotation technique and use photon beam energies in the range of 6~10 MV. Reviews of the characteristics of several treatment techniques can be found in the literature (Podgorsak 1989, Schell 1991). More in recent, static conformal beams defined by custom shaped collimators or a mini- or micro-multileaf collimator (mMLC) have been used in SRS. Finally, in the last few years, intensity-modulated mMLC SRS has also been introduced. Today, many commercial and in-house SRS programs have also introduced non-invasive immobilization systems include the cyberknife and tomotherapy and proton beam. This document will be compared the characteristics of dose distribution of radiosurgery as introduced gamma knife, BrainLab include photon knife in-house SRS program and cyberknife in currently wide used for a cranial SRS.

Induction of Micronuclei in Human and Mouse Lymphocytes Irradiated with Gamma Radiation and Effect of Panax ginseng C.A. Meyer (마우스와 사람 림프구에서 방사선에 의한 미소핵의 형성 및 고려인삼의 효과)

  • Kim, Sung-Ho;Oh, Heon;Lee, Song-Eun;Lee, Yun-Sil;Kim, Tae-Hwan;Jeong, Kyu-Sik;Ryu, Si-Yun
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.153-160
    • /
    • 1997
  • The frequencies of ${\gamma}$-ray-induced micronuclei (MN) in cytokinesis-blocked (CB) lymphocytes at several doses were measured in three donors of human and C57BL/6 mice. Measurements performed after irradiation showed a dose-related increases in MN frequency in each of the donors studied. The relative sensitivity of mouse in spleen lymphocytes (SLs) compared with human peripheral blood lymphocytes (PBLs) was estimated by best fitting linear-quadratic model based on the radiation-induced MN data over the range from 0 cGy to 400 cGy. In the case of MN frequency with 0.2 per CB cell, the relative sensitivity of mouse SLs was 1.67. Compared with the radiation-induced MN formation in the PBLs of human, the SLs of mouse were more radiosensitive. Using this MN assay with human PBLs and mouse SLs, studies were performed to determine whether the water fraction of ginseng (Panax ginseng C.A.Meyer) against radiation-induced MN in human PBLs after in vitro irradiation (3Gy) and in SLs of C57BL/6 mice after in vivo irradiation (3Gy). The frequency of MN in human PBLs was reduced by water fraction of ginseng (0.5mg/ml of medium) both pre-and post treatment (p<0.0l) in vitro. In addition, the frequency of MN in mouse SLs was also reduced by pretreatment of ginseng (2mg/ml of drinking water for 7days) in vivo. The data suggested that the ginseng may reduce cell damage caused by ${\gamma}$-rays in vitro and in vivo. Further studies are needed to characterize better the protective nature of ginseng extract, its fractions and compounds.

  • PDF

Interferon-${\gamma}$ Enzyme-Linked Immunospot Assay in Patients with Tuberculosis and Healthy Adults

  • Kim, Cheol-Hong;Kim, Jong-Yeop;Hwang, Yong Il;Lee, Chang Youl;Choi, Jeong-Hee;Park, Yong-Bum;Jang, Seung-Hun;Woo, Heungjeong;Kim, Dong-Gyu;Lee, Myung Goo;Hyun, In-Gyu;Jung, Ki-Suck;Kim, Hyun Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.76 no.1
    • /
    • pp.23-29
    • /
    • 2014
  • Background: Interferon-${\gamma}$ assays based on tuberculosis (TB)-specific antigens have been utilized for diagnosing and ruling out latent TB and active TB, but their utility is still limited for TB incidence countries. The aim of this study is to understand the clinical utility of enzyme-linked immunospot (ELISpot) assays among patients with clinically suspected TB and healthy adults in clinical practices and community-based settings. Methods: The ELISpot assays (T SPOT.TB, Oxford Immunotec, UK) were prospectively performed in 202 patients. After excluding those with indeterminate results, 196 were included for analysis: 41 were TB patients, 93 were non-TB patients, and 62 were healthy adults. Results: The sensitivity and negative predictive values of the T SPOT.TB assays for the diagnosis of TB were 87.8% and 89.1%, respectively, among patients with suspected TB. The agreement between the tuberculin skin test (10-mm cutoff) and the T SPOT.TB assay was 66.1% (kappa=0.335) in all participants and 80.0% (kappa=0.412) in TB patients. Among those without TB (n=155), a past history of TB and fibrotic TB scar on chest X-rays were significant factors that yielded positive T SPOT.TB results. There was a significant difference in the magnitude of T SPOT.TB spot counts between TB patients and non-TB patients or healthy adults. Conclusion: The T SPOT.TB assay appeared to be a useful test for the diagnostic exclusion of TB. A positive result, however, should be cautiously interpreted for potential positives among those without active TB in intermediate TB incidence areas.

Shielding Effectiveness of Magnetite Heavy Concrete on Cobalt-60 Gamma-rays

  • Lim, Yong-Kyu
    • Nuclear Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.65-75
    • /
    • 1971
  • The gamma-ray shielding effects of magnetite concretes have been measured using a broad beam Co-60 gamma-ray source. Mathematical formulae for a trans-mission ratio-to-shield thickness relation were derived from the attenuation curve obtained experimentally and are I (x) = I (ο) exp(-$\mu$X) exp(1.03$\times$10$^{-1}$ X-3.38$\times$10$^{-3}$ X$^2$+5.29$\times$10$^{-5}$ X$^3$) when X< 20 cm, I (x) =I (ο) exp(-$\mu$X) exp(4.66$\times$10$^{-2}$ X+2.12$\times$10$^{-1}$ ) when X>20 cm. Here I (x) is radiation intensity after passing through a thickness X of absorber, I(o) is the initial radiation intensity, $\mu$ is the linear attenuation coefficient of magnetite concrete and is given by (0.0532$\rho$+ 0.0083)$^{4)}$ $cm^{-1}$ / in accordance with an earlier study, and X is the thickness of absorber. In addition, a model shield which is a rectangular magnetite concrete box with walls of 8cm thickness walls and internal demensions of 40$\times$40$\times$40 cm was constructed and its shielding effect has been measured. The emergent radiation flux appears to be greater with this configuration than with a slab shield of equal thickness.

  • PDF

Spectroscopic Properties of a Silicon Photomultiplier-based Ce:GAGG Scintillation Detector and Its Applicability for γ-ray Spectroscopy (감마선 분광분석을 위한 실리콘 광 증배소자 기반 Ce:GAGG 섬광검출기의 분광특성 연구)

  • Park, Hye Min;Kim, Jeong Ho;Kim, Dong Seong;Joo, Koan Sik
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.73-78
    • /
    • 2015
  • In this study, a scintillation detector was fabricated using a silicon photomultiplier (SiPM) and a Ce:GAGG scintillator single crystal, and its spectroscopic properties were compared with those of commercially available LYSO and CsI:Tl scintillators using ${\gamma}$-ray spectroscopy. The energy resolutions of the self-produced scintillation detector composed of the scintillator single crystal (volume: $3{\times}3{\times}20mm^3$) and SiPM (Photosensitive area: $3{\times}3mm^2$) for standard ${\gamma}$-ray sources, such as $^{133}Ba$, $^{22}Na$, $^{137}Cs$ and $^{60}Co$ were measured and compared. As a result, the energy resolutions of the proposed Ce:GAGG scintillation detector for g-rays, as measured using its spectroscopic properties, were found to be 13.5% for $^{133}Ba$ 0.356 MeV, 6.9% for $^{22}Na$ 0.511 MeV, 5.8% for $^{137}Cs$ 0.662 MeV and 2.3% for $^{60}Co$ 1.33 MeV.

Gamma-ray-induced skin injury in the mini-pig: Effects of irradiation exposure on cyclooxygenase-2 expression in the skin (감마선조사에 의한 돼지 피부장애에 cyclooxygenase-2의 발현변화)

  • Kim, Joong Sun;Park, Sunhoo;Jang, Won Seok;Lee, Sun Joo;Lee, Seung Sook
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.65-72
    • /
    • 2015
  • The basic concepts of radiation-induced skin damage have been established, the biological mechanism has not been studied. In this study, we have examined the effects of gamma rays on skin injury and cyclooxygenase(COX)-2 expression. Gamma irradiation induced clinicopathological changes in a dose- and time-dependent manner in mini-pig skin. The histological changes were consistent with the changes in gross appearance at 12 weeks after irradiation. After three days' irradiation, apoptotic cells in the basal layer were found more frequently in irradiated skin than in normal skin, with the magnitude of the effect being dose-dependent. The thickness of the epidermis transiently increased 3 days after irradiation, and then gradually decreased, although changes in the epithelial thickness of the irradiated field were not observed with irradiation doses over 50 Gy. In the epithelium, there was an initial degenerative phase, during which the rate of basal cell depletion was dependent on the radiation dose (20-70 Gy). One week after irradiation, COX-2 expression was mostly limited to the basal cell layer and was scattered across these cells. High COX-2 expression was detected throughout the full depth of the skin after irradiation. The COX-2 protein is upregulated after irradiation in mini-pig skin. These histological changes associated with radiation exposure dose cause the increased COX-2 expression in a dose-dependent fashion.

Deep Learning Applied Method for Acquisition of Digital Position Signal of PET Detector (PET 검출기의 디지털 위치 신호 측정을 위한 딥러닝 적용 방법)

  • Byungdu, Jo;Seung-Jae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.697-702
    • /
    • 2022
  • For imaging in positron emission tomography(PET), it is necessary to measure the position of the scintillation pixel interacting with the gamma rays incident on the detector. To this end, in the conventional system, a flood image of the scintillation pixel is obtained, the imaged area of each scintillation pixel is separated, and the position of the scintillation pixel is specified and acquired as a digital signal. In this study, a deep learning method was applied based on the signal formed by the photosensor of the detector, and a method was developed to directly acquire a digital signal without going through various procedures. DETECT2000 simulation was performed to verify this and evaluate the accuracy of position measurement. A detector was constructed using a 6 × 6 scintillation pixel array and a 4 × 4 photosensor, and a gamma ray event was generated at the center of the scintillation pixel and summed into four channels of signals through the Anger equation. After training the deep learning model using the acquired signal, the positions of gamma-ray events that occurred in different depth directions of the scintillation pixel were measured. The results showed accurate results at every scintillation pixel and position. When the method developed in this study is applied to the PET detector, it will be possible to measure the position of the scintillation pixel with a digital signal more conveniently.