• Title/Summary/Keyword: ${\gamma}-ray$

Search Result 1,824, Processing Time 0.037 seconds

Early Growth Changes in Juvenile Abalone Haliotis discus discus Produced by Irradiation with Low-dose 60Co Gamma Rays (저선량 60Co감마선 조사 후 생산된 둥근전복(Haliotis discus discus)치패의 초기성장 변화에 관한 연구)

  • Jwa, Min Seok;Yeo, In-Kyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.48 no.2
    • /
    • pp.193-199
    • /
    • 2015
  • We observed that the growth and physiological change in Haliotis discus discus by low-dose irradiation with gamma ray.Irradiation with gamma ray was undertaken by using the low-level irradiation facility ($^{60}CO$) in cooperation with the Institute of Nuclear Science and Technology at Jeju National University. The parent abalones were attached one by one and then fixed by using the rubber band to the front side of the fabricated case for irradiation with gamma ray. The experimental plots of irradiation with gamma ray were set as 10, 15, 20 and 25 Gy and the 25 female abalones and 10 male abalones were utilized for each experimental plot. The sperms and eggs were fertilized by setting an interval for each dose to prevent mixing with other experimental plots when fertilizing the sperms and eggs for each dose of irradiation with gamma ray. As for the fertility, it was confirmed to be 85% the control and 10 Gy groups, whereas it was found to be 80%, 65% and 50% in the 15 Gy, 20 Gy and 25 Gy groups, respectively. As a conclusion, the hatching rate and attachment rate were higher at 10 and 15 Gy than the other experimental plots, and the growth rate was higher at 20 Gy than the other experimental plots. Also the changes in lysozyme activity in accordance with the stress of water temperature were found to have a significant increase in the other experimental plots as compared with the control plot at the end of 0 h. The changes in lysozyme activity have remained constant in all the experimental plots at the end of 12 h. These results allowed us to confirm that lysozyme was undertaking the biodefense action by reacting sensitively to the stress of water temperature in the control experimental plot. As for the other experimental plots, they are believed to avoid the biodefense mechanism due to the high degree of anti-parasite mechanism and anti-viral mechanism. Thus, it is believed that it would be imperative to conduct development and research on breeds that were potent for environmental tolerance by applying the method of irradiation with gamma ray to other marine animals and plants.

Development of a Wireless Gamma-ray Probe for Diagnosing and Evaluation of its Effectiveness (진단용 무선 감마선 프로브 개발 및 유용성 평가)

  • Park, Hyemin;Joo, Koansik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.173-181
    • /
    • 2015
  • We developed a wireless gamma-ray probe based on radiation photon counting method to diagnose and detect remaining lesions after surgery, and its effectiveness was evaluated using calibration sources and a phantom. The probe was designed and miniaturized using a semi-conductor-based radiation sensor, and a Bluetooth remote communication module was used to implement the wireless diagnosis and detection system. Moreover, a remote monitoring system was implemented to monitor affected areas during diagnosis and surgery. To assess the effectiveness of the developed probe in this study, calibration sources $^{57}Co$, $^{133}Ba$, $^{22}Na$ and $^{137}Cs$ and a chicken breast phantom were used. Furthermore, the probe's detection response to gamma ray was confirmed through evaluation. Its clinical applicability was verified by assessing the response linearity and detection direction according to gamma-ray intensity, as well as the detection efficiency according to the depth of the gamma source in the phantom.

Development of Real-Time Thickness Measuring System for Insulated Pipeline Using Gamma-ray (감마선을 이용한 단열배관의 실시간 두께측정시스템 개발)

  • Jang, Ji-Hoon;Kim, Byung-Joo;Kim, Gi-Dong;Cho, Kyung-Shik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.500-507
    • /
    • 2002
  • By this study, on-line real-time radiometric system was developed using a 64 channels linear array of solid state detectors to measure wall thickness of insulated piping system. This system uses an Ir-192 as a gamma ray source and detector is composed of BGO scintillator and photodiode. Ir-192 gamma ray source and linear detector array mounted on a computer controlled robotic crawler. The Ir-192 gamma ray source is located on one side of the piping components and the detector array on the other side. The individual detectors of the detector array measure the intensity of the gamma rays after passing through the walls and the insulation of the piping component under measurement. The output of the detector array is amplified by amplifier and transmitted to the computer through cable. This system collects and analyses the data from the detector array in real-time as the crawler travels over the piping system. The maximum measurable length of pipe is 120cm/min. in the case of 1mm scanning interval.

Background Reduction for the ${\gamma}$-Ray Spectrometry of Environmental Radioactivity (환경방사능의 감마선 분광분석을 위한 백그라운드 소멸)

  • Seo, Bum Kyoung;Lee, Kil Yong;Yoon, Yoon Yeol;Lee, Dae Won
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.212-220
    • /
    • 2001
  • This study was performed to establish the analytical method of radium and radon in various environmental samples with the ${\gamma}$-ray spectrometry. The major problem in the measurements of low level ${\gamma}$-ray, such as environmental radioactivity, is the fluctuation of ${\gamma}$-ray background spectrum. To overcome this problem, a nitrogen gas was filled up in the detector chamber to reduce the background counts due to airborne radioactivities, i.e., $^{214}Pb$ and $^{214}Bi$, the daughters of $^{222}Rn$ in air. When nitrogen gas flowed around the detector, peak counts of ${\gamma}$-rays from the daughters of $^{222}Rn$ decreased about 80% below 1 MeV and about 20~50% above 1 MeV. The use of nitrogen purging results in approximately tenfold increment of sensitivity.

  • PDF

Protective Effect of Perilla frutescens cv. Chookyoupjaso Mutant Water Extract on Gamma Ray-induced Oxidative Stress in Mice (감마선에 의한 산화적 스트레스에 돌연변이 약용들깨 열수추출물의 방호 효능)

  • Jin, Chang Hyun;Cho, Byoung Ok;Choi, Dae Seong;Ryu, Hyung Won;Baek, Ji Yeong;Jeong, Il Yun
    • Journal of Radiation Industry
    • /
    • v.5 no.2
    • /
    • pp.125-130
    • /
    • 2011
  • The purpose of this study was to evaluate the protective effect of the Perilla frutescens cv. Chookyoupjaso mutant water extract (PFWE) on gamma ray-induced oxidative stress in mice. Gamma-ray is one of the sources for inducing oxidative stress. The study was divided into 6 groups with 6 mice for each treatment. Groups I and II were treated with saline (vehicle) only, groups III, IV, V, and VI were pretreated with PFWE 10, 20, 50, $50mg\;kg^{-1}$ respectively for 2 weeks before gamma radiation. And then groups II, III, IV, V were irradiated. We found that the activities of aspartate transaminase (AST) and alanine transaminase (ALT) were increased and the activities of antioxidant enzymes such as superoxide dismutase (SOD), catalase (CAT), glutathione peroxidase (GPx), and glutathione reductase (GR) were decreased by irradiation in mice. However, treatment of PFWE attenuated the activities of AST and ALT in a dose-dependent manner in irradiated mice. Furthermore, treatment of PFWE significantly increased the activities of SOD, GPx, and GR in a dose-dependent manner in irradiated mice, except for the CAT. Interestingly, the activities of GPx and GR were significantly increased by PFWE treatment. Taken together, PFWE could be effective in protecting on gamma ray-induced oxidative stress in mice.

Gamma ray attenuation behaviors and mechanism of boron rich slag/epoxy resin shielding composites

  • Mengge Dong;Suying Zhou ;He Yang ;Xiangxin Xue
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2613-2620
    • /
    • 2023
  • Excellent thermal neutron absorption performance of boron expands the potential use of boron rich slag to prepare epoxy resin matrix nuclear shielding composites. However, shielding attenuation behaviors and mechanism of the composites against gamma rays are unclear. Based on the radiation protection theory, Phy-X/PSD, XCOM, and 60Co gamma ray source were integrated to obtain the shielding parameters of boron rich slag/epoxy resin composites at 0.015-15 MeV, which include mass attenuation coefficient (µt), linear attenuation coefficient (µ), half value thickness layer (HVL), electron density (Neff), effective atomic number (Zeff), exposure buildup factor (EBF) and exposure absorption buildup factor (EABF).µt, µ, HVL, Neff, Zeff, EBF and EABF are 0.02-7 cm2/g, 0.04-17 cm-1, 0.045-20 cm, 5-14, 3 × 1023-8 × 1023 electron/g, 0-2000, and 0-3500. Shielding performance is BS4, BS3, BS3, BS1 in descending order, but worse than ordinary concrete. µ and HVL of BS1-BS4 for 60Co gamma ray is 0.095-0.110 cm-1 and 6.3-7.2 cm. Shielding mechanism is main interactions for attenuation gamma ray by BS1-BS4 are elements with higher content or higher atomic number via Photoelectric Absorption at low energy range, and elements with higher content via Compton Scattering and Pair Production in Nuclear Field at middle and higher energy range.

Development of a flexible composite based on vulcanized silicon casting with bismuth oxide and characterization of its radiation shielding effectiveness in diagnostic X-ray energy range and medium gamma-ray energies

  • Ibrahim Demirel;Haluk Yucel
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2570-2575
    • /
    • 2024
  • The study aims to develop a novel, lead-free, flexible and lightweight composite shielding material against ionizing radiation. For this, it was used bismuth oxide (Bi2O3) in RTV-2 silicon matrix. The shielding tests were carried out in both diagnostic X-ray energies and intermediate gamma-ray energy range of up to 662 keV to determine the radiation attenuation properties of this material in terms of attenuation ratio, half value layer, tenth value layer, mean free path and lead equivalency of samples in weight of 30%, 40%, 50% in Bi2O3. In the diagnostic X-ray energy range, half value layer, tenth value layer and lead equivalency (in mm Pb) of the produced samples were measured at 80 and 100 kVp narrow beam conditions according to the requirements of EN IEC 61331-1 standard. The results show that lead equivalent values of the produced novel sheets was measured to be 0.16 mm Pb, corresponding to a 6 mm thickness of the flexible sample when it contains 30% wt. Bi2O3 in RTV matrix. The experimental findings for durability and flexibility also indicated that this new RTV-based flexible, lead -free shielding composite can be used safely for especially for manufacturing aprons, garments and thyroid guards used in mammography, radiology, nuclear medicine and dental applications in practice.

Study On Irradiation Effect By Co$^{60}$To The Condensers Which Are Used In Electronic Circuit (O.F paper condenser를 비롯한 전자회로용 condenser들에 대한 Co$^{60}$의 조사효과에 관한 연구)

  • 지철근;조성욱
    • 전기의세계
    • /
    • v.23 no.3
    • /
    • pp.67-69
    • /
    • 1974
  • The electric characteristics of all the instruments and materials used in atomic field is changed due to radiation damages by the effects of radio activities. In this study, when the condenser is radiated by Gamma-ray, variations in its electric properties have been investigated. The following results are obtained. (1) The capacitance in O.F paper condenser is exponentially increased as the quantity of irradiation by Gamma-ray is increased, but polyethylene, ceramic, chemical, neostyrene, mylar condenser are decreased. and in case of more than 10$^{7}$ of irradiation it has saturated state, (2) The breakdown voltage and the .delta. in condensers except the O.F paper condenser are exponentially increased as the quantity of irradiation by Gamma-ray is increased but in case of more than 10$^{7}$ .gamma. of irradiation it has decreased.

  • PDF

FOREGROUND OF GAMMA-RAY BURSTS (GRBS) FROM AKARI FIS DATA

  • Toth, L. Viktor;Doi, Yasuo;Zahorecz, Sarolta;Agas, Marton;Balazs, Lajos G.;Forro, Adrienn;Racz, Istvan I.
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.113-116
    • /
    • 2017
  • A significant number of the parameters of a gamma-ray burst (GRB) and its host galaxy are calculated from the afterglow. There are various methods obtaining extinction values for the necessary correction for galactic foreground. These are: galaxy counts, from HI 21 cm surveys, from spectroscopic measurements and colors of nearby Galactic stars, or using extinction maps calculated from infrared surveys towards the GRB. We demonstrate that AKARI Far-Infrared Surveyor sky surface brightness maps are useful uncovering the fine structure of the galactic foreground of GRBs. Galactic cirrus structures of a number of GRBs are calculated with a 2 arcminute resolution, and the results are compared to that of other methods.

VLC Wireless Data Transmission of High Luminance LED Irradiated by the High Dose-Rate Gamma-Ray (고 선량 감마선 조사에 따른 고휘도 LED의 가시광 무선 데이터 전송)

  • Cho, Jai-Wan;Choi, Young-Soo;Hong, Seok-Boong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.996-1000
    • /
    • 2010
  • In order to apply VLC (visible light communication) in harsh environment of nuclear power plant in-containment building, the high luminance LEDs, which are key components of the VLC system, have been gamma irradiated at the dose rate of 4 kGy/h during 72 hours up to a total dose of 288 kGy. The radiation induced coloration effect in the high luminance LED bulb made of acryl or plastic material was observed. In the VLC wireless data transmission experiment using the high luminance LEDs irradiated by high dose rate gamma-ray, the radiation induced coloration effect of the high luminance LED bulb extended the communication distance compared to non-irradiated LEDs.