• 제목/요약/키워드: ${\beta}-D-(3-O-sinapoyl) fructofuranosyl-{\alpha}-D-(6-O-sinapoyl)glucopyranoside$

검색결과 2건 처리시간 0.015초

내복자(Raphani Semen)로부터 Sinapic acid esters의 분리 (Isolation of Sinapic Acid Esters from Raphani Semen)

  • 강은정;고병섭;김호경
    • 생약학회지
    • /
    • 제31권4호
    • /
    • pp.434-437
    • /
    • 2000
  • Two sinapic acid esters were isolated from the methanol extract of Raphani Semen. The structures were elucidated on the basis of spectroscopic methods $(^1H-NMR,\;^{13}C-NMR,\;HMQC,\;^1H-^1H\;COSY\;and\;HMBC)$ and were identified as methyl sinapate (1) and ${\beta}-D-(3-O- sinapoyl)fructofuranosyl-{\alpha}-D-(6-O-sinapoyl)glucopyranoside$ (2). Compound 1 was first isolated from the genus of Raphanus.

  • PDF

UHPLC를 이용한 새로운 한약제제 HPL-1의 품질관리법 개발 (Development of Quality Control Method for a Novel Herbal Medicine, HPL-1 using UHPLC)

  • 김세건;라마칸타라미차네;이경희;정현주
    • 대한본초학회지
    • /
    • 제30권3호
    • /
    • pp.19-24
    • /
    • 2015
  • Objectives : HPL-1, a novel herbal medicine which is composed of five herbs such as Kalopanacis Cortex, Chaenomelis Fructus, Raphani Semen, Atractylodis Rhizoma and Pulvis Aconiti Tuberis Purificatum, was developed for treatment of osteoarthritis. This study is aimed to develop analytical method for consistent quality control of HPL-1 and validate chromatographic method. Methods : Chromatographic analysis was performed using ultra-high performance liquid chromatography - diode array detector (UHPLC-DAD) equipped with RP-amide column, column oven, and auto sampler. Marker compounds [protocatechuic acid, chlorogenic acid, liriodendrin, 3,5-dicaffeoylquinic acid, ${\beta}$-D-(3-O-sinapoyl)-fructofuranosyl-$\alpha$-D-(6-O-sinapoyl)glucopyranoside and benzoylmesaconine] were separated by step gradient elution of acetonitrile and 0.1% phosphoric acid/water. The method validation was evaluated by quantitative validation parameters of linearity, accuracy, precision, limit of detection (LOD) and limit of quantification (LOQ) according to KFDA guideline.Results : An optimized method for six marker compounds in HPL-1 was established by UHPLC-DAD. The correlation coefficient (R2) with each calibration curve was greater than 0.99. The LOD and LOQ were within the range of 0.008-0.090 and $0.023-0.274{\mu}g/mL$, respectively. The relative standard deviation (RSD) of intra- and inter-day variability were less than 4.0%. The result of recovery test was range from 93.3-106.3% with RSD < 4.0%.Conclusions : These results suggest that the quantitative UHPLC method is precise, accurate, effective for quality evaluation of HPL-1. The method may also contribute to improve quality of crude drug preparations used for treatment of various diseases.