• Title/Summary/Keyword: $^{99m}TcO_{4}$

Search Result 81, Processing Time 0.029 seconds

A Convenient Method on the Methyl-Ethyl-Ketone Extraction of $^{99m}TcO^-{_4}$ ($^{99m}TcO^-{_4}$의 메틸-에틸-케톤-간편 추출법)

  • Lee, Jong-Du;Lee, Byung-Hyn
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.2
    • /
    • pp.103-111
    • /
    • 1984
  • A convenient method of $^{99m}Tc$-methyl-ethyl-ketone (MEK) extraction technique was developed and a mobile $^{99m}Tc$-extraction generator was designed. The MEK extraction and the phase separation of $^{99m}TcO^-{_4}$ were carried out with a simple procedure in the same container. The shielding of $^{99}Mo$ radioactivity was made with one lead container. The system was simplified by shielding $^{99m}TcO_4{^-}({\gamma}_e=0.14\;MeV)$ separately. $^{99m}TcO^-{_4}\;in\;^{99m}Tc-MEK$ extract was recovered by adsorption and elution only, and therefore, the possibility of volatilization was reduced. The volume of $^{99m}TcO^{-}{_4}$-saline product was reduced to 1 ml by using a small alumina column and the column operation time was shortened. The separation time of $^{99m}Tc$ was reduced to 30 minutes, and the operation was carried out at the outside of the shielding. The system was designed to operate under the condition of bacteria-free.

  • PDF

A Study of Gamma-ray Distribution around the $^{99}Mo-^{99m}TcO_4$ Generator ($^{99}Mo-^{99m}TcO_4$ Generator의 감마선량 분포에 관한 연구)

  • Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.24 no.1
    • /
    • pp.49-53
    • /
    • 2001
  • A number of radionuclides of interest in nuclear medicine are short lived isotopes that emit only gamma ray. The most of all Dept. of Nuclear Medicine in the hospt. are using the $^{99}Mo-^{99m}Tc$ generator for elution of the short lived isotope $^{99m}TcO_4$. A $^{99}Mo-^{99m}Tc$ generator consists of an alumina column on which $^{99}Mo$ is bound. The parent isotope($^{99}Mo$ : half life 67 hr.) decays to its daughter $^{99m}TcO_4^-$ which is a different element with a shorter half-life. $^{99}Mo$ emitted 41-keV(1.3%), 141-keV(5.6%) 181-keV(6.6%) and 366-keV(1.5%) gamma rays. But $^{99m}TcO_4$ emitted only 140-keV gamma ray. We study about the gamma ray distribution around the $^{99}Mo$ generator. And obtained the result as follows ; 1. Total counted gamma ray from generator smaller in front side than back. 2. The gamma ray emitted from $^{99}Mo$ generator without $^{99m}TcO_4$ vial increased in the back side(Mo column posited side) 3. The gamma ray only from the $^{99m}TcO_4$ vial increased in the front side. 4. Apron can protect gamma ray above 60% of total radiation from the $^{99}Mo$ generator.

  • PDF

Phantom Study of the Mutual Influences Between 18F-FDG and 99mTcO4- on the Same Day (18F-FDG와 99mTcO4-를 이용한 당일 검사 시 상호 영향에 대한 Phantom 연구)

  • Ham, Jun Cheol;Park, Min Soo;Bahn, Young Kag;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.68-72
    • /
    • 2014
  • Purpose The nuclear medicine examination, there is a difficulty to carry out the inspection of both on the day of residual isotope due to the half-life. In this study, by studying the mutual influence and $^{18}F$-FDG of $^{99m}TcO_4{^-}$, I would like to explain the matters to be considered in the case of performing the same day. Materials and Methods With the NEMA-1994 Phantom, and experiments were performed 3 times. Create a 1: 4 Background ratio HOT and the $^{99m}TcO_4{^-}$ The first experiment: After underwent SPECT in INFINIA (GE Healthcare, MI, USA), and were injected with $^{18}F$-FDG 37 MBq in the Background area, 13 once for 60 minutes under the same conditions was time Scan. Create a 1: 4 Background ratio HOT and the $^{18}F$-FDG second is: The Scan in PET/CT Discovery 600 (GE Healthcare, MI, USA), and 148 MBq after injection $^{99m}TcO_4{^-}$ the Background area, once for 60 minutes, 6 under the same conditions was time Scan. Create a 1: 4 Background ratio HOT and the $^{18}F$-FDG experiments las, increments of 296 MBq and 148 MBq the 1 Bed Scan after $^{99m}TcO_4{^-}$, was 1 Bed Scan under the same conditions. Non BKG area and HOT, I was measured comparing the Total Counts and SNR or CNR. Results Showed a significant difference in the ratio CNR of enforcement during SPECT $^{18}F$-FDG is, (p>0.05). The $^{99m}TcO_4{^-}$ was no significant difference between the SNR ratio of PET / CT at the time of the effective date (p<0.05). I got the results $^{99m}TcO_4{^-}$ that reduce the Total Counts of PET / CT scan. Conclusion If you make a PET / CT scan, may affect the test using the $^{99m}TcO_4{^-}$ up to 12 hours, when it is performed before the $^{99m}TcO_4{^-}$, does not affect the SNR and SUV, PET / CT scan I reduced the detection efficiency. The inspection of day, we'd like to recommend a way to complement the detection efficiency to increase the inspection time of PET / CT in move forward the inspection using the $^{99m}TcO_4{^-}$.

  • PDF

Analysis of Hemodynamic Change in Diffuse Hepatocellular Diseases (미만성 간질환에서의 간혈류 동태의 분석에 관한 연구)

  • Lee, Sung-Yong;Chung, Soo-Kyo;Lee, Yung-Il;Kim, Jong-Woo;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.2
    • /
    • pp.53-59
    • /
    • 1986
  • Radionuclide angiography of the liver and spleen with rapid bolus injection of 5 mCi of $^{99m}Tc-Sn-phytate$ was performed for evaluation of dynamic flow change of the liver in 5 normal subjects and 11 patients with diffuse hepatocellular diseases. And quantification of hepatic arterial index (HAI) was generated from those TACs of the liver and compared with HAI generated from hepatic TAC with injection of $^{99m}Tc-TcO_4^-$ as previously reported method by former investigators, 67 patients with diffuse hepatocellular diseases undergoing hepatic scintigraphy were also evaluated by 2 minutes-hepatosplenic scintiangiography with 5 mCi of $^{99m}Tc-phytate$ and followed injection of 7 mCi of $^{99m}Tc-TcO_4^-$. Those heaptic and splenic TACs were analysed and compared with HAIs of 99m Tc-phytate for evaluation of relative change (%) of count at 30 seconds and 1 minuite after peaks of rapid influx phase to the peaks (100%) in T ACs of $^{99m}Tc-phytate$ and at 1 minuite and 3 minuites after in 5 minuite-TAC of $^{99m}Tc-TcO_4^-$. Correlation between HAIs with $^{99m}Tc-phytate$ and $^{99m}Tc-TcO_4^-$ was highly significant (R=0,984, P=0), and there was most significant and useful correlation (R=0,708, p<0.0001) between HAI and splenic TAC generated by $^{99m}Tc-phytate$.

  • PDF

Synthesis of $^{99m} Tc$-tricarbonyl Precursors for Labeling of Bioactive Molecules

  • Jang, Beom-Su;Kim, Yong-Mi;Cho, Sang-Mu;Shin, Byung-Chul;Park, Sun-Ju;Hong, Young-Don;Gwon, Hui-Jeong;Park, Kyung-Bae;Yun, Hyo-In
    • Nuclear Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.146-153
    • /
    • 2002
  • To radiolabel bioactive molecules, we synthesized $^{99m}$Tc-tricarbonyl precursor, [$^{99m}$Tc(CO)$_3$($H_2O$)$_3$]$^{+}$ with a low oxidation state ( I ). The [$^{99m}$Tc(CO)$_3$($H_2O$)$_3$]$^{+}$ was prepared by low pressure carbonylation (1 atm of CO) of [$^{99m}$Tc $O_4$)]$^{[-10]}$ in the presence of NaB $H_4$ resulting in higher than 98% of labeling yield and stability up to 8 hrs. We evaluated the characteristics of $^{99m}$Tc- tricarbonyl labeled bioactive molecules by carrying out in vitro and in vitro study. Prepared [$^{99m}$Tc(CO)$_3$($H_2O$)$_3$]$^{+}$ was then reacted with some ligands of significance in modem diagnostic nuclear medicine and some amino acids. Labeling yields were checked by HPLC and found to be usually high, excluding $^{99m}$Tc-tricarbonyl-MDP, -EDTMP and -mIBG. And the biodistribution properties of $^{99m}$Tc-tricarbonyl complexes applied in rabbit showed different appearance comparing with that of the $^{99m}$Tc-labeling by conventional means. From these results, we conclude that [$^{99m}$Tc(CO)$_3$($H_2O$)$_3$]$^{+}$ is a potential precursor for development of radiopharmaceuticals, especially for labeling of biomolecules.

Thyroid imaging in 53 cats with hyperthyroidism using technetium-99m as pertechnetate

  • Lee, Young-won
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.2
    • /
    • pp.394-397
    • /
    • 1999
  • Thyroid imaging was performed in 53 hyperthyroid cats with technetium-99m as pertechnetate($^{99m}TcO_{4}$). Increased radionuclide accumulation was found in all cats. Thirty-four cats had bilateral enlargements of the thyroid glands and 14 cats had unilateral enlargements. Five cats had multi-focal accumulation of $^{99m}TcO_{4}$ in the ventral neck or mediastinum. Conclusively, nuclear thyroid image is useful method in diagnosis of feline hyperthyroidism.

  • PDF

Polymer Formation and Altered Biodistribution of IgG Labeled with $^{99m}Tc$ and Cyclic DTPA (항체의 Cyclic DTPA를 이용한 $^{99m}Tc$ 표지시 Polymer 형성과 체내 동태 변화)

  • Lim, Sang-Moo;Woo, Kwang-Sun;Chung, Wee-Sup;Awh, Ok-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.270-276
    • /
    • 1993
  • $Technetium-^{99m}$ labeling method using bifunctional chelating agent cyclic DTPA has been evaluated with human polyclonal nonspecific IgG. IgG was conjugated with cyclic DTPA with various molar ratio. Reduction of $^{99m}Tc$ was done with $Na_2S_2O_4$ with various molar excess. Labeling efficiency and identification of polymer was confirmed with HPLC using TSK4000 SW column. Polymer was purified with 100 cm Sepharose 6LB column. Cultured $1{\times}10^9$ Staphylococcus aureus were injected into rat thigh 24 hours later labeled IgG was injected, and in vivo distribution was observed 4 and 24 hours thereafter. Reduction of $^{99m}Tc$ was optimal with the 10000-50000 times molar excess of $Na_2S_2O_4$. Polymer formation increased with increasing mloar excess of cyclic DTPA to IgG. Three step labeling-labeling DTPA conjugated IgG after reduction of $^{99m}Tc$-made more polymer than two two step labeling-simultaneous mixing DTPA conjugated IgG, $^{99m}Tc$ and $Na_2S_2O_4$. $^{99m}Tc$ blood clearance and lower uptake in the abscess and other organs. IgG conjugated with 200 times molar excess of cyclic DTPA showed slower blood clearance with 200 times molar excess of cyclic DTPA showed slower blood clearance than that of 200 times molar excess of cyclic DTPA showed slower blood clearance than that of 20 times molar excess. In the $^{99m}Tc$ labeling of IgG with cyclic DTPA for the immunoscintigraphy, obtimal labeling condition should be chosen, and effect of the $^{99m}Tc$ labeled IgG polymer should be considered.

  • PDF

Preparation of $^{99m}Tc$ Ferric Hydroxide Macroaggregates for Lung Perfusion Studies

  • Kim, Young-Hwan;Kim, Young-Sup;Kim, Young-Kuk
    • Nuclear Engineering and Technology
    • /
    • v.4 no.4
    • /
    • pp.327-330
    • /
    • 1972
  • $^{99m}$Tc Ferric Hydroxide Macroaggregates for Lung Perfusion Studies were prepared from home made Na $^{99m}$TcO$_4$ which was extracted by methyl ethyl ketone from low activity $^{99m}$Mo. Particle size was in between 20 and 60$\mu$. Rabbit and human body tests gave excellent results.sults.

  • PDF

Studies on Preparation of $^{99m}Tc$ Complexes of Methionine Isomers (Methionine 이성질체들의 $^{99m}Tc$ 착물 제조 연구)

  • Awh, Ok-Doo;Chang, Hee-Soon;Lee, Dong-Sun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.140-146
    • /
    • 1992
  • $^{99m}Tc-Methionine$ complexes from enantiomeric and racemic methionines were prepared controlling reaction parameters such as pH and the concentration of stannous chloride. Some radiochromato-graphic systems were also examined to determine the labelling yields of $^{99m}Tc$ complexes. The best resolutions of $^{99m}Tc$ complexes were obtained at ITLC-SA developed with acetone and paper chromatography with n-butanol saturated with 0.3N HCI. In the former system, $HR-{99m}Tc$ and $^{99m}Tc-methionine$ complex remained at origin, while $^{99m}TcO_4^-$ moved with Rf value of 1.0. In latter process, $HR-^{99m}Tc$ stayed at the origin, while $^{99m}TcO_4^-\;and\;^{99m}Tc-methionine$ complexes moved with Rf value of 0.5. By combining of two chromatographic systems, the contents of three $^{99m}Tc$ species were calculated easily. $^{99m}Tc$ Labelling from enantiomeric and racemic methionines had little differences and the optimal condition was found at pH 9.00 and the molar ratio of methionine to stannous chloride of 24:1. The yields of $^{99m}Tc$ complexes from D-, L-, and DL-methionines were 87.6%, 94.1%, and 97.9%, respectively. The results indicated that methionine containing relatively hydrophobic methylthio group $(-SCH_3)$ would be labelled with $^{99m}Tc$ by stannous chloride method.

  • PDF

A Study on the Thyroid Scan Images by Different Radionuclides ($^{99m}Tc$ pertechnetate and $^{131}I$) and Multiple Views (사용핵종(使用核種) 및 주사방향(走査方向)에 따른 갑상선주사상(甲狀腺走査像)의 차이(差異)에 관한 연구(硏究))

  • Whang, Il-Yong;Chung, Soon-Il;Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.1
    • /
    • pp.53-58
    • /
    • 1986
  • Thyroid scans using $Na^{131}I\;and\;^{99m}TcO_4^-$ in two (anterior and anterior oblique) projections were done simultaneously in 50 patients with single palpable nodule and in euthyroid state(nodular nontoxic goiter) and 20 normal subjects to evaluate the imaging ability of each radionuclide and the necessity of oblique view. In detection of a nodule as a cold or cool area, $^{99m}TcO_4^-$ was slightly superior to $^{131}I$(82 % to 78% with anterior view alone, 92% to 84% when oblique view is added in detectability), with addition of an oblique view, 5 more cold or cool area in $^{99m}Tc$ scan and 3 more $^{131}I$ scan were detected. In normal subjects $^{99m}TcO_4^-$ scan was significantly superior to $^{131}I$ scan(90% to 70%) in getting normal pattern of tracer uptake in the glands. For routine imaging study of the thyroid, $^{99m}Tc$ pertechnetate scan with multiple projection is considered to be a preferable method.

  • PDF