• Title/Summary/Keyword: $^{99m}Tc-Tin$ colloid

Search Result 31, Processing Time 0.037 seconds

A Static Scintigraphy for Imaging Aspiration Using Semi-Solid Food (반고형식을 이용한 정적 흡인 영상법)

  • Yoon, Min-Ki;Hwang, Kyung-Hoon;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.327-331
    • /
    • 2006
  • Purpose: Aspiration scintigraphy is a procedure of nuclear imaging to evaluate aspiration and of quantifying the amount of aspirate. The ultimate goal of our study is to define the correlation between aspiration and aspiration pneumonia by aspiration scintigraphy and this is a preliminary report of its trial. Materials and methods: Ten patients with positive findings by videofluoroscopy were selected. The patients ingested semi-solid food containing Tc-99m tin colloid 92.5 MBq (2.5 mCi) and images were acquired immediately after the ingestion and 3 hrs later. A fraction of aspiration to the ingested was calculated using an equation with a decay correction. Results: Five patients were interpreted positive by aspiration scintigraphy. Four patients were positive at initial images and the fractions of aspiration were 0.11%, 0.11%, 0.81%, and 0.11%. The one patient who was shown aspirated at both images had initial 5.82% and delayed 2.26%. Conclusion: Aspiration scintigraphy enables us to localize the aspiration at any desired time of the test and to quantify its amount. Follow-up studies are warranted.

Quantitation of Hepatic and Extrahepatic $^{99m}Tc-Tin$ Colloid Uptake in the Hepatocellular Diseases (간세포성 질환에서의 간 및 간외 $^{99m}Tc-Tin$ Colloid 섭취의 정량분석)

  • Park, Young-Ha;Kim, Choon-Yul;Kim, Sung-Hoon;Park, Seog-Hee;Park, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.1
    • /
    • pp.9-16
    • /
    • 1987
  • It is well-known that hepatic scintigraphv have been found to be less sensitive and specific in the detection of the diffuse hepatocellular diseases than that of the space-occupying lesions. To obtain the higher diagnostic specificity and sensitivity, we, using the computer quantitation, have attempted to analyze hepatic and extrahepatic $^{99m}Tc-tin$ colloid uptake patterns in various diffuse hepatocellular diseases retrospectively. The studied groups consisted of 116 cases of normal, 67 cases of acute hepatitis, 112 cases of chronic hepatitis, 61 cases of liver cirrhosis, 47 cases of fatty liver, 12 cases of hepatoma and 9 cases of metastasis, making total 424 cases. Scintigraphic imagings were obtained in the anterior, right lateral and posterior projections using high-resolution collimation, and simultaneously these gamma data were acquisited into the computer system. Both large region of interest (ROI) using light pen and ROI computer program were placed over right lobe, left lobe of liver, spleen and cardiac blood pool. Total counts in ROI were divided by the number of pixels in the ROI, and mean count rate per pixels calculated. Mean right-lobe counts were divded by mean-left lobe counts to determine right-to-left hepatic lobe ratio and mean spleen counts were divided by mean liver counts to determine spleen to liver ratio. The results were as follows. 1) Of 424 cases, 292 were male and 132 were female. The majority of age distribution was in $30\sim49$ (54.5%). 2) Inter-observer between two independant operators and inter-method between drawing by light-pen and ROI computer program variations were not significant. 3) The uptake count values (per pixel) determined at each area in normal group were $106.53{\pm}18.35$ in right lobe, $79.00{\pm}13.82$ in left lobe, $17.52{\pm}8.31$ in spleen and $8.09{\pm}3.43$ in cardiac blood pool. 4) In liver cirrhosis, right lobe uptake was decreased but spleen and cardiac blood pool uptakes were increased (p<0.01). 5) Right-to-left hepatic lobe uptake ratio was $1.37{\pm}0.24$ in normal group and significantly low in chronic hepatitis, liver cirrhosis and fatty liver, and more or less low in acute hepatitis. 6) Spleen-to-right hepatic lobe uptake ratio was $0.17{\pm}0.09$ in normal group and high in chronic hepatitis and liver cirrhosis. 7) The computer-quantitation of hepatic and extrahepatic uptake patterns thought to be sensitive and useful method in the interpretation of liver scintigram.

  • PDF

A Case of with Transient splenic Hot Uptake on $^{99m}Tc$-Methylene Diphosphonate(MDP) Bone Scan Following Blunt Abodominal Trauma with Underlying Liver Cirrhosis (간경변환자에서 복부외상후 일시적으로 관찰된 $^{99m}Tc$-MDP Bone Scan의 비장 섭취 1예)

  • Won, Jong-Hyeon;Kim, Jae-Myung;Kim, Jung-Han;Choo, Gil-Yeon;Park, Seok-Oh;Sung, Sang-Kyu;Choi, Dae-Seob;Kim, Chin-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.309-314
    • /
    • 1993
  • We report a case of 33-year-old man with a transient splenic uptake who had traumatic multiple rib fractures and hernoperitoneum combined with underlying liver cirrhosis, liver cirrhosis with liver bed laceration and splenomegaly without any other demonstrable splenic lesion due to traffic accident was found by abdominal ultrasound and surgery. Incidentally, $^{99m}Tc$-MDP Bone scan showed whole prominent splenic uptake, spleen was also visible on $^{99m}Tc$ Tin colloid liver scan. We suggest the splenic uptake of the radionuclide temporary splenic infarct to the transient total splenic infarction or unknown traumatic effect.

  • PDF

Camparison between the 1 Day and the 2 Day Protocols of Lymphoscintigraphy and Sentinel Node Biopsy using Subareolar Injection in Breast Cancer Patients: A Retrospective Study (유륜하 주사에 의한 유방암 환자의 전초림프절 스캔과 전초림프절 생검에 있어서 당일검사와 전날검사의 비교: 후향적 연구)

  • Seok, Ju-Won;Jun, Sung-Min;Nam, Hyun-Yeol;Kim, In-Ju
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.1
    • /
    • pp.55-59
    • /
    • 2009
  • Purpose: Lymphoscintigraphy and sentinel node biopsy are used in detection of axillary lymph node metastasis in breast cancer patients, but standardized technique is not established. We compared the results of the injection the morning of surgery (1 day protocol) with the subareolar injection the day before surgery (2 day protocol) with the subareolar injection in patients with breast cancer having lymphoscintigraphy and sentinel node biopsy. Materials and Methods: This study included 349 patients who underwent the breast cancer operation during 2001-2004. One hundred seventy one patients (1 day protocol, 1 hour) was injected 0.8ml of Tc-99m Tin-Colloid (37 MBq) by subareolar injection on the morning of surgery. One hundred seventy eight patients (2 day protocol, 16 hour) was injected 0.8 ml of T c-99m Tin-Colloid (185 MBq) on the afternoon before surgery. Lymphoscintigraphy was performed in sitting position and sentinel node localization was performed by hand-held gamma probe during operation. Result: In the 1 day protocol, 153 cases (89.5%) of the sentinel node were localized by lymphoscintigraphy and 150 cases (87.7%) were localized by gamma probe. In the 2 day protocol, 159 cases (89.3%) were localized by lymphoscintigraphy and 154 cases (86.5%) were localized by gamma probe. There was no significant difference in localization of sentinel node between the 1 day and the 2 day protocol by lymphoscintigraphy and gamma probe (p>0.05, p>0.05). Conclusion: There was no difference the result of localization of sentinel node with subareolar injection between the 1 day and the 2 day protocol in breast cancer patients. Because the 2 day protocol allows the enough time of performing lymphoscintigraphy, it is more useful in localization of sentinel node in breast cancer patients.

[ $^{99m}Technetium-Heat$ ] Damaged Erythrocyte Spleen Scan ($^{99m}Technetium$-가열처리 적혈구에 의한 비장스캔)

  • Choi, Chang-Woon;Park, Seok-Gun;Chung, June-Key;Lee, Myung-Chul;Cho, Bo-Youn;Koh, Chang-Soon;Chung, Soon-Il
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.1
    • /
    • pp.39-43
    • /
    • 1986
  • [ $^{99m}Technetium-Heat$ ] damaged erythrocyte were used as spleen scanning agents in 12 patients from July, 1985 to April, 1986. We used this scan to evaluate situs inversus, asplenia, accessory spleen, hypersplenism, splenic infarction, tumor staging and evaluation of therapy, especially when the $^{99m}Tc-tin$ colloid scans were not definite for diagnosis. The techniques applied to these scans were in vivo/in vitro-labeling method and heating-method to damage the erythrocytes. Liver-to-spleen uptake ratios were increased upto 100 : 1 and interference from the left lobe of the liver was eliminated. These scans were helpful to evaluate the spleen.

  • PDF

Measurement of Normal Gastric Emptying Rate Using Chicken Liver Labeled with $^{99m}Tc-Colloid$ (정상인의 Gastric Emptying Rate 측정)

  • Lee, Cheorl-Woo;Kim, Chahng-Guhn;Kim, Byung-Chan;Won, Jong-Jin;Nah, Yong-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.22 no.2
    • /
    • pp.193-197
    • /
    • 1988
  • Measurement of gastric emptying rate has been performed by a variety of techniques. Nuclear medicine method is a major advance in the quantitative evaluation of gastric function and also of pharmacologic intervention. Normal gastric emptying rate was measured in 48 healthy volunteers using live chicken liver labeled with $^{99m}Tc-Tin$ Colloid as a solid phase marker. In vitro studies were performed to evaluate the labeling efficiency and stability in hydrochloric acid and in human gastric juice of intracellularly labeled chicken liver. Anterior image counts only were compared with the geometric mean of anterior and posterior counts in 12 healthy volunteers who were studied by both anterior count and posterior count. The results were as follows: 1) The labeling efficiency in gastric juice and hydrochloric acid were $95.5{\pm}1.23%,\;95.7{\pm}1.15%$, respectively. 2) Half gastric emptying time by anterior count only was $126{\pm}21$ minutes 3) Although standard deviation of geometric mean method was smaller than anterior count method, gastric emptying curves from both method were similar. In daily practice, anterior count method may be useful alternative to geometric mean method in evaluation of gastric emptying rate.

  • PDF

Radionuclide Esophageal Transit Study in the Esophageal Motility Disorders (식도 운동 질환에 있어서 동위원소 식도 통과 검사의 의의)

  • Choe, Jae-Gol;Lee, Min-Jae;Song, Chi-Wook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.233-238
    • /
    • 1993
  • Esophageal motility was evaluated from the analysis of 10 consecutive swallows using liquid bolus containing 0.5 mCi of $^{99m}Tc$ tin colloid. We have reviewed our experience of esophageal transit study in the 20 normal volunteers and 55 patients with dysphagia that was not related to mechanical obstruction. The purpose of this study is to measure the esophageal transit in normal subjects and in patients with various esophageal motility disorders. The overall sensitivity and specificity of radionuclide esophageal transit study in detecting esophageal motor abnormality were compared with manometric results as a gold standard, which were 80% and 100% respectively. Radionuclide transit study is a safe, rapid, noninvasive test and suitable as a screening test for esophageal motor disorders.

  • PDF

A Case of Hepatic Hydrothorax (간수흉 1예)

  • Hong, In-Soo;Yang, Hak-Suk;Sung, Ki-Joon;Kim, Myung-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.392-395
    • /
    • 1992
  • Hepatic hydrothorax is defined as the presence, in a cirrhotic patient, of a large pleural effusion in the absence of primary pulmonary or cardiac disease. Pleural effusions occur in 5% to 10% of patients with cirrhosis of the liver. The effusions are usually right-sided, but may be bilateral or left-sided. The precise mechanism of fluid accumulation is not clear. We reported a case of right hepatic hydrothorax occuring in the liver cirrhosis with ascites. Diagnosis was confirmed by the intraperitoneal and intrapleural injection of radioisotope $^{99m}Tc-tin$ colloid that demonstrated the one-way transdiaphragmatic flow of fluid from the peritoneal to pleural cavities.

  • PDF