• 제목/요약/키워드: $^{99m}Tc-MIBI$ myocardial perfusion scan

검색결과 11건 처리시간 0.03초

관상동맥질환에서 디피리다몰 부하 $^{99m}Tc-MIBI$ 심근스캔의 폐/심장 섭취율 (Lung/Heart Uptake Ratio in Dipyridamole $^{99m}Tc-MIBI$ Myocardial Perfusion Scan in Coronary Artery Disease)

  • 강건욱;이동수;최창운;이경한;정준기;이명철;서정돈;고창순
    • 대한핵의학회지
    • /
    • 제27권2호
    • /
    • pp.218-222
    • /
    • 1993
  • Lung/heart uptake ratio (L/H R) in $^{201}Tl$ myocardial perfusion scan is a reliable marker for long-term prognosis in patients with coronary artery disease. However, the value of L/H R in $^{99m}Tc-MIBI$ myocardial perfusion scan is controversial in determining the prognosis and severity of the coronary artery disease. The purpose of this study was to determine the clinical implications of L/H R in $^{99m}Tc-MIBI$ myocardial perfusion scan. Forty five patients who received $^{99m}Tc-MIBI$ myocardial perfusion scan were divided into control group and coronary artery disease (CAD) group by their clinical findings, EKGs, and $^{99m}Tc-MIBI$ myocardial perfusion scans. Twenty five patients in CAD group were divided into ischemic group and infarct group according to their results from $^{99m}Tc-MIBI$ myocardial perfusion scan. L/H R was calculated on the anterior planar view, 60 minutes after infusion of dipyridamole. Two regions of interest (ROI) were placed on the left lung area 8 pixel above the left ventricle and on the myocardial area which had the highest radioactivity. In the control group, there were no significant differences of L/H R according to sex and age. No significant difference of L/H R was found between the control and CAD group ($0.26{\pm}0.06,\;0.29{\pm}0.05$, p>0.05). In the CAD group, there was also no significant difference of L/H R between the ischemic group and infarct group ($0.29{\pm}0.07,\;0.30{\pm}0.04$, p>0.05). L/H R in CAD group did not show correlations with the defect area of stress polar map (r=0.18, p >0.05) and with the sum of severity weighted extent score or reversibility score which represent severity and extent of myocardial perfusion defect area in stress (r=0.18, p>0.05). We conclude that it is difficult to use L/H R as a marker for severity of CAD in dipyridamole $^{99m}Tc-MIBI$ myocardial perfusion scan.

  • PDF

반도체 심근 전용 감마카메라를 이용한 Rest 99mTc-sestaMIBI/Stress201Tl 이중 동위원소 심근 관류 동시 스캔에 관한 임상적 고찰 (Clinical Study of Simultaneous Acquisition Rest 99mTc-sestaMIBI/Stress 201Tl Dual-Isotope Myocardial Perfusion Imaging with a Solid-State Dedicated Cardiac Gamma Camera)

  • 반영각;김동희;최용훈;강천구;김재삼
    • 핵의학기술
    • /
    • 제22권2호
    • /
    • pp.88-91
    • /
    • 2018
  • 본 연구는 반도체 심근 전용 감마카메라를 이용하여 단시간에 검사가 가능한 이중 동위원소 심근 관류 동시스캔에 대해 임상적으로 연구 해보고자 한다. 심장 전용 감마카메라를 사용하여 Rest/Stress $^{99m}TC$-sestaMIBI 당일 심근관류 스캔과 Rest $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ 이중 동위원소 심근 관류 동시 스캔을 같이 검사한 86명의 환자 중 검사 결과가 동일하고 임상적으로 심장질환의 변화가 없는 환자 36명을 대상으로 분석 했다. 두 검사의 영상의 상관성을 확인하기 위해 QPS 프로그램을 이용하여 정량적 값을 통계적으로 분석 했다. Rest/Stress $^{99m}TC$-sestaMIBI 당일 심근관류 스캔과 $^{99m}TC$-sesta MIBI/Stress $^{201}Tl$ 이중 동위원소 심근 관류 동시 스캔을 summed score에서 상관도를 분석했다. RSS의 $R^2$ 값은 0.91로 나왔고, SSS의 $R^2$ 값은 0.71로 나왔다. $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ 이중 동위원소 동시 검사는 기존 당일 검사와 상관성을 확인했다. $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ 이중 동위원소 동시 검사는 검사시간이 약 30분만에 완료가 가능하다. 응급환자나 고령의 환자 등 짧은 검사시간이 필요한 환자에게 임상적으로 도움이 될 것으로 사료된다.

심근 관류스캔 중 정상 부하영상 소견을 보인 환자에서 휴식기 영상의 필요성에 대한 평가 (The Role of Rest Image in Patients Showing Normal Stress Image on Tc-99m Myocardial Perfusion Scan)

  • 범희승;송호천;민정준;김지열
    • 대한핵의학회지
    • /
    • 제30권4호
    • /
    • pp.502-506
    • /
    • 1996
  • 연구 목적 : 디피리다몰 부하-휴식 Tc-99m MIBI 일일 심근영상법에서 부하기 영상이 정상인 환자에서 휴식기 영상이 필요한지 알아보고자 하였다. 대상 및 방법 : 흉통을 주소로 전남대학교병원을 내원하여 핵의학과에서 디피리다몰 부하/휴식 MIBI 심근관류 SPECT를 시행한 환자 중 부하시 스캔 소견상 관류결손이 없었고, 심근관류검사 전후 1개월 이내에 관동맥조영술로 관동맥병변 유무가 확진된 43명의 환자(남:여=24:19, 평균연령 $52{\pm}11세$)를 대상으로 하였다. 촬영방법은 디피리다몰 부하-휴식 Tc-99m MIBI 일일 심근영상법을 사용하였다. 결과 및 결론 : 부하기 영상이 정상인 환자 중 관동맥질환이 없는 경우 휴식기에도 정상으로 나올 확률은 79% (23/29)였고, 새로운 관류결손이 나올 확률은 21%였다. 부하기 영상이 정상이면서 관동맥질환이 있는 환자에서 휴식기 영상으로 새로운 결손을 찾아낼 확률은 22%였다. 따라서, 흉통을 호소하는 환자에서 부하기 영상이 정상일때 휴식기 영상은 대체로 추가적인 정보를 주지 못한다는 것을 알 수 있었다. 그러나, 관동맥경련이 있는 환자는 5명 중 4명(80%)에서 휴식기 영상에 새로운 관류결손이 보일 수 있으므로, 관동맥경련이 의심되는 환자에서는 휴식기 영상을 촬영할 필요가 있을 것으로 사료되었다.

  • PDF

$^{201}Tl$$^{99m}Tc-MIBI$에 의한 생존심근의 진단 비교 -재분포영상에 고정관류결손을 보인 환자에서 $^{201}Tl$ 재주사법 및 $^{99m}Tc-MIBI$ 휴식기스캔에 의한 심근섭취 비교- (Comparison of $^{99m}Tc-MIBI$ Myocardial Uptake at Rest with Reinjection and 24-hour after Reinjection Images of $^{201}Tl$)

  • 범희승;김지열;박주형;안영근;정명호;조정관;박종춘;강정채
    • 대한핵의학회지
    • /
    • 제26권2호
    • /
    • pp.274-279
    • /
    • 1992
  • Clinical role of $^{99m}Tc-MIBI$ myocardial scintigraphy in the diagnosis of coronary artery disease (CAD) is now well accepted, however, the role of it in the identification of viable myocardium in patients with chronic CAD has not yet been clarified. To determine the usefulness of rest-injected $^{99m}Tc-MIBI$ scan as a marker of myocardial viability, the regional uptake of this agent at rest was compared with that of $^{201}Tl$ on reinjection and 24 hours after reinjection images. Subject patients were 13 chronic CAD patients who showed irreversible perfusion defect(s) on standard pharmacologic (dipyridamole) stress-redistribution images. Immediately after the redistribution images were obtained, 37 MBq thallium was injected at rest, and images were reacquired at 10 minutes and 24 hours after reinjection. After then 740 MBq $^{99m}Tc-MIBI$ was injected, and 1 hour later rest MIBI myocardial imaging was performed. Five sets of imagestress, redistribution, reinjection, delayed images of thallium, and rest image of MIBI) were then analyzed qualitatively and quantitatively. Left ventricle was arbitrarily divided into 9 segments (apex, basal and apical portions of anterior, septal, inferior, and lateral walls). Seven patients and 30 regions showed a fixed perfusion defect on the stress-redistribution images. Among 30 regions, 15 showed positive uptakes and 6 showed negative uptakes on both $^{201}Tl$ reinjection/delayed images and $^{99m}Tc-MIBI$ rest images. Five regions showed only thallium uptake and were regarded as viable clinically. Of four regions which showed only $^{99m}Tc-MIBI$ uptake, two were regarded as viable, while the other two were regarded as a nonviable scar tissue clinically. In conclusion, $^{201}Tl$ reinjection technique was more reliable in the identification of viable myocardium. However, the role of $^{99m}Tc-MIBI$ in identification of viable myocardium was still remained to be clarified because 2 of 9 regions showed only $^{99m}Tc-MIBI$ uptake and were regarded as viable tissues.

  • PDF

관상동맥질환에서 휴식기의 심근관류 정도와 휴식기 심기능 변화의 비교 - Dipyridamole 부하 $^{99m}Tc-MIBI$ SPECT와 휴식기 Gated Blood Pool Scan - (Comparison between Myocardial Perfusion and Function in Rest State in Coronary Artery Disease - Dipyridamole $^{99m}Tc-MIBI$ SPECT and Rest Gated Blood Pool Scan -)

  • 최창운;이동수;김상은;배상균;양형인;정준기;이명묵;이명철;박영배;서정돈;이영우;고창순
    • 대한핵의학회지
    • /
    • 제26권2호
    • /
    • pp.265-273
    • /
    • 1992
  • Rest gated blood pool scan (Rest GBP scan) and dipyridamole $^{99m}Tc-MIBI$ SPECT were Performed in 34 patients with or suspected coronary artery disease. Both studies were performed within $2\sim32$ days (mean 8.1 days). A significant correlation was present between left ventricular ejection fraction (r= -0.7356, p<0.001) and peak ejection rate and peak filling rate in rest GBP scan and perfusion defect in MIBI SPECT. And there were acceptable correlations (0.05$26.2{\pm}10.8%$, severe hypokinesia, akinesia or dyskinesia in 16 regions: $78.2{\pm}23.7$, p<0.001). These data indicate there is a significant coupling between the degree of myocardial perfusion and the myocardial functional change in coronary artery disease.

  • PDF

심전도 게이트 심근관류 Tl-201 SPECT로 측정된 좌심실 기능 및 좌심실 용적의 정확성 (Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Tl-201 Perfusion Single Photon Emission Tomography)

  • 배문선;문대혁
    • 대한핵의학회지
    • /
    • 제39권2호
    • /
    • pp.94-99
    • /
    • 2005
  • Electrocardiogram-gated single photon omission computed tomography (SPECT) provides valuable information in the assessment of both myocardial perfusion and ventricular function. Tl-201 is a suboptimal isotope for gating. Tl-201 images are more blurred compared with Tc-99m tracers due to the increased amount of scattered photons and use of a smooth filter. The average myocardial count densities are approximately one-half those of conventional technetium tracers. However, Tl-201 is still widely used because of its well-established utility for assessing myocardial perfusion, viability and risk stratification. Gated SPECT with Tl-201 enables us to assess both post-stress and rest left ventricular volume and function. Previous studies with gated Tl-201 SPECT measurements of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) have shown high correlation with first-pass radionuclide angiography, gated blood pool scan, Tc-99m-MIBI gated SPECT, contrast ventriculography, echocardiography, and 3-dimensional magnetic resonance imaging. However, problems related to these studies include few agreement data of EDV and ESV, use of a reference method that is likely to have the same systemic errors (gated Tc-99m-MIBI SPECT), and other technical factors related to the count density of gated SPECT. With optimization of gated imaging protocols and more validation studies, gated Tl-201 SPECT would be an accurate method to provide perfusion and function information in patients with coronary artery disease.

운동 정도와 무관한 Tc-99m Methoxyisobutyl Isonitrile 심근관류 스캔의 진단능 (Diagnostic Ability of Tc-99m MIBI SPECT in Coronary Artery Diseases is not Affected by the Degree of Exercise)

  • 이재태;김종수;천경아;이상우;강도영;조용근;채성철;이규보
    • 대한핵의학회지
    • /
    • 제33권1호
    • /
    • pp.40-48
    • /
    • 1999
  • 목적: 운동부하 심전도검사에 나타나는 ST-분절의 하강은 운동부하의 정도에 영향을 받는다. 그러나 운동부하의 정도가 운동부하 심근관류영상의 관동맥 질환 진단능에 미치는 영향은 보고자마다 달라 아직도 논란이 되고있다. 본 연구는 운동부하의 정도가 심근관류 영상의 관상동맥 질환 진단능에 미치는 영향을 규명하고자 시행하였다. 대상 및 방법: 111명(남자 73명, 여자 38명, 평균연령: 56세)의 안정된 환자를 대상으로 운동부하검사와 함께 Tc-99m MIBI를 이용한 심근관류 스캔을 실시하고 3개월 이내에 관상동맥촬영술을 실시하였다. 운동부하의 정도는 운동시 최대 예측 심박수의 85%에 도달했는가를 기준으로 하고, 운동심전도 소견을 첨가하여 4군으로 구분하고 각각의 군에서의 진단능을 비교하였다. 결과: 1) Tc-99m MIBI 심근관류스캔의 예민도와 특이도는 심전도검사의 소견이나 심박수의 증가정도에 따른 차이는 없었다. 2) 운동부하 Tc-99m MIBI SPECT의 예민도는 87%, 특이도는 79%였고 전례를 대상으로 한 경우 운동부하 심전도는 예민도 55%, 특이도 74%로서 예민도는 SPECT가 운동부하 심전도보다 유의하게 높았으며 특이도는 유의한 차이는 없었으나 SPECT가 더 높은 경향을 보였다. 3) 최대 예측 심박수의 85% 이상의 운동량에 도달한 경우의 관동맥 질환 진단 예민도는 85% 이하의 운동량에 도달한 군과 유사하였다(88% vs 87%, p=NS). 4) 운동부하 정도가 적었으나 조기에 심전도 검사상 양성 소견을 보인 경우에는 다혈관 질환에서 개개 혈관의 협착 진단능은 낮은 경향을 나타내었다. 결론: 이상의 결과로 볼 때 운동부하 Tc-99m MIBI 심근관류 스캔의 관동맥 협착 진단능은 운동부하 심전도검사보다 높았고, 답차를 이용한 증상 제한적 운동부하검사에서 심박동수의 증가로 평가란 운동 정도가 운동 목표량에 도달하지 않아도 진단능이 감소되지 않음을 알 수 있었다.

  • PDF

일상적인 운동 부하 게이트 심근 관류 SPECT에서 $^{99m}Tc-sestamibi$ 폐섭취 : 좌심실 구혈률과 관류 결손 정도와의 비교 (Lung Uptake of $^{99m}Tc-sestamibi$ during Routine Gated Exercise SPECT Imaging : Comparison with Left Ventricular Ejection Fraction and Severity of Perfusion Defect)

  • 정신영;이재태;배진호;안병철;이규보
    • 대한핵의학회지
    • /
    • 제37권2호
    • /
    • pp.83-93
    • /
    • 2003
  • 배경 및 목적: $^{201}Tl$ 심근 관류 SPECT에서, 폐-심장 섭취비(lung-to-heart uptake ratio; LHR)의 정량적 측정은 관동맥 질환자의 예후를 평가할 수 있는 지표이다. 그러나 최근$^{99m}Tc-sestamibi$ (MIBI)를 이용한 심근 관류 SPECT가 많이 이용되고 있으나 MIBI의 폐섭취가 관동맥 질환자에 $^{201}Tl$ LHR와 같은 의미를 가지는 지는 의문이 있어왔다. 본 연구는 MIBI 주사후 1시간에 촬영한 전면상을 이용하여 LHR을 구하여 좌심실 구혈률, 관류 결손 정도와의 상관 관계를 알아보고자 하였다. 대상 및 방법: Bruce법으로 운동 부하를 실시한 241명(남성 130명, 평균 연령 55세)을 대상으로 하였다. 부하검사와 휴식기 검사를 같은 날에 실시하는 프로토콜(1일 영상법)은 152명, 다른 날에 실시하는 프로토콜(2일 영상법)은 89명에서 시행하였다. 운동 부하 SPECT는 MIBI를 주사한 후 1시간에 이중헤드 감마 카메라를 이용하여 얻었다. 폐와 심장의 MIBI 섭취 정도는 20초간 얻은 전면상에서 폐와 심장에 관심영역을 설정하여 구하고, 이를 이용하여 섭취비를 계산하였다. AutoQUANT 소프트 웨어를 이용한 자동화 방법으로 운동부하시 좌심실 구혈률(LVEF)을 구하였고 운동부하시 관류 결손 정도(Summed Stress Score, SSS)를 구하였다. LVEF에 따라 3군(35%이하, 36-50%, 50%초과), SSS에 따라 4군(4미만, 4-8, 9-13, 13초과)으로 나누었다. 증가된 LHR의 정의는 관류 결손이 없는 남, 여 각 군에서 구한 LHR의 평균값에 표준편차의 2배값을 더한 값을 초과하는 것으로 판단하였고 각 군에서 증가된 LHR을 보인 환자의 분포를 구하여 비교하였다. 결과: 정상 관류 소견을 보였던 130명의 분석에서, 여성에 비해 남성에서 LHR이 유의하게 높았고 정상 관류 소견을 보였던 130명의 남성과 여성 모두에서, 1일 영상법와 2일 영상법을 실시한 군 사이의 LHR은 의미 있는 차이가 관찰되지 않았다. 정상 관류 소견을 보인 군과 관류 결손을 보인 군 사이의 비교에서는 관류 결손이 있는 남성과 여성에서 관류 결손이 없는 남성과 여성에 비해 LHR이 유의하게 높았다. 관류 결손이 있는 111명의 분석에서는 LHR과 EF는 역상관 관계, LHR과 SSS 사이에는 양의 상관 관계가 관찰되었고, 남성에서는 통계학적 의의가 있었으나 여성에서는 통계학적 의의는 없었다. EF군에 따른 분석에서는 좌심실 구혈률이 낮을수록 LHR이 높았고, SSS군에 따른 분석에서 관류 결손이 높은 군에서 유의하게 LHR가 높았다. 결론: 일상적인 운동부하 심근 관류 SPECT상 관류 결손이 있는 환자에서 폐심장 섭취비는 좌심실 구혈률과 심근 부하시 관류 결손 정도가 클수록 증가된 폐-심장 섭취비를 보인 환자가 많았으며, 좌심실 구혈률이 낮을수록 그리고 관류 결손의 정도가 클수록 폐-심장 섭취비가 증가하였다 이런 결과로 보아 주사후 1시간 $^{99m}Tc-MIBI$의 LHR은 좌심실 부전과 큰 관류 결손을 나타내는 간접적인 지표로 생각되어 진다. 그러나 관류 결손의 정도나 좌심실 구혈률 감소 정도가 미약한 군에서는 폐-심장 섭취비가 정상군과 비슷하여, 저위험군의 감별에는 제하점이 있다.

우측 관상동맥 폐쇄 환자에서 관상동맥내 Thallium-201 주사를 이용한 측부 혈행의 의의 (Functional Significance of Angiographic Collaterals in Patients with Totally Occluded Right Coronary Artery: Intracoronary Thallium-201 Scintigraphy)

  • 이도연;이종두;조승연;심원흠;하종원;김한수;권헉문;장양수;정남식;김성순;박창윤;김용수
    • 대한핵의학회지
    • /
    • 제27권2호
    • /
    • pp.210-217
    • /
    • 1993
  • To compare the myocardial viability in patients suffering from total occlusion of the right coronry artery (RCA) with the angiographic collaterals, intracoronary injection of Thallium-201 (T1-201) was done to 14 coronary artery disease (CAD) patients (pts) with total occlusion of RCA and into four normal subjects for control. All 14 CAD pts had Grade 2 or 3 collateral circulations. There were 14 male and 4 females, and their ages ranged from 31 to 70 years. In nine pts, T1-201 was injected into left main coronary artery (LCA) ($300{\sim}350{\mu}Ci$) to evaluate the myocardial viability of RCA territory through collateral circulations. The remaining five pts received T1-201 into RCA ($200{\sim}250{\mu}Ci$) because two had intraarterial bridging collaterals and three had previous successful PTCA. Planar & SPECT myocardial perfusion images were obtained 30 minutes, and four to five hours after T1-201 injection. Intravenous T1-201 reinjection (six pts) or $^{99m}Tc-MIBI$ (two pts) were also performed in eight CAD pts. Intracoronary myocardial perfusion images were compared with intravenous T1-201 (IV T1-201) images, ECG, and ventriculography. Intracoronary T1-201 images proved to be superior to that of IV T1-201 due to better myocardial to background uptake ratio and more effective in the detection of viable tissue. We also found that perfusion defects were smaller on intracoronary T1-201 images than those on the IV T1-201. All of the 14 CAD pts had either mostly viable myocardium (seven pts) or large area of T1-201 perfusion (seven pts) in RCA territory, however ventriculographic wall motion and ECG did not correlate well with intracoronary myocardial perfusion images. In conclusion, total RCA occlusion patients with well developed collateral circulation had large area of viable myocardial in the corresponding territory.

  • PDF

심근 관류 스펙트에서 Half-Time Scan과 새로운 재구성법이 적용된 정상군 데이터를 기반으로 한 정량적 분석 결과의 차이 비교 (The Effects of Discrepancy in Reconstruction Algorithm between Patient Data and Normal Database in AutoQuant Evaluation: Focusing on Half-Time Scan Algorithm in Myocardial SPECT)

  • 이형진;도용호;조성욱;김진의
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.122-126
    • /
    • 2014
  • 최근 장비회사에서 제공하고 있는 half-time 기법과 recon algorithm은 검사시간의 단축과 영상의 질은 향상되지만, 핵의학 검사의 특성 상 정량적 분석 시 자동으로 이뤄지는 검사의 경우 기존의 결과값과 어떻게 달라지는지에 대하여 언급된 바는 없었다. 심근 관류 SPECT는 과거 다른 영상법과 마찬가지로 판정의 주관성이 문제로 제기되어 왔으나, 근래에는 다양한 자동 정량화 분석법이 상용화되어 보급되고 있어 이러한 문제를 극복하였다. 그러나 $^{13}N$을 이용한 PET의 검사와는 달리 자동 정량화 프로그램을 통해 얻어지는 관류정량값의 경우 실제 관류량을 측정하는 것이 아니고 최대 섭취화소에 대한 상대적 섭취값을 표시하는 간접적 또는 반정량적 측정치임을 고려해야 한다. 이 연구에서는 정량적 게이트 심근 관류 SPECT에서 정상군 데이터를 재편집하였을 때 또한 그 데이터가 어떠한 성질을 가지고 있느냐에 따른 결과값의 변화를 조사하였다. 정량 분석 시 사용되는 Cedars사의 AutoQuant 프로그램은 정상군 데이터를 다시 편집할 수 있는 기능이 있어서 각 병원의 검사법에 맞게 정상군 데이터를 삽입하여 사용이 가능하다. SRS, SSS, Extent, TPD와 같은 결과 지표값이 본원에서 재편집한 정상군 데이터를 이용하여 보았더니 약 30% 낮은 값을 보였다. 재편집한 정상군 데이터의 성질은 한국인이면서 $^{201}Tl$, $^{99m}Tc-MIBI$를 사용하는 dual isotope 방법이었고, half-time method인 Philips사의 Astonish를 적용한 정상군 데이터였다. 본 조사를 통하여 임상적으로 어떠한 결과를 내리는 것은 성급한 일이지만, 정상군 데이터를 자체적으로 확보하고 이를 자동 정량화방법에 이용한다면 게이트 심근관류 SPECT의 임상적 유용성이 더욱 커질 것으로 기대해본다.

  • PDF