• 제목/요약/키워드: $^{99m}Tc(CO)_3$

검색결과 34건 처리시간 0.022초

지연성 일산화탄소중독후유증 환자에서 $^{99m}Tc-HMPAO$를 이용한 국소 뇌혈류량의 SPECT소견 (Studies on the Regional Cerebral Blood Flow in Delayed Carbon Monoxide sequelae using $^{99m}Tc-HMPAO$)

  • 안재훈;이도연;김진수;서정호;김동익;이명식;정태섭;박찬희
    • 대한핵의학회지
    • /
    • 제22권2호
    • /
    • pp.163-170
    • /
    • 1988
  • 8 patients of delayed CO sequelae were evaluated using Brain CT and $^{99m}Tc-HMPAO$ SPECT. The results were as follows; 1) CT findings of delayed CO sequleae were bilateral low density lesion in globus pallidus (l pt.), diffuse low density in white matter with bilateral low density in white matter (l pt.), diffuse low density in white matter with bilateral low density in globus pallidus (l pt.), diffuse low density in white matter with cortical atrophy (l pt.), bilateral low density in globus pallidus and diffuse low density in white matter with cortical atrophy (l pt.) and normal in 3 pts. 2) $^{99m}Tc-HMPAO$ Brain SPECT findings of delayed CO sequelae were decreased regional cerebral blood flow (rCBF) in frontal (1 among 8 pts.), frontal and basal ganglia (3 among 8 pts.), and diffuse patch decreased rCBF pattern (4 among 8 pts.) 3) $^{99m}Tc-HMPAO$ Brain SPECT study was well correlated with neurologic symptoms and signs in delayed CO sequelae. Our results may suggest that reduced cerebral blood flow contributes to the development of delayed CO sequelae.

  • PDF

Dose calibrator 측정 깊이와 용량의 변화에 따른 선량 값의 성향에 대한 고찰 (A Study on the Tendency of Dose value According to Dose calibrator Measurement Depth and Volume)

  • 김진구;함준철;오신현;강천구;김재삼
    • 핵의학기술
    • /
    • 제24권1호
    • /
    • pp.20-26
    • /
    • 2020
  • 핵의학이란 방사성동위원소 추적자를 인체에 투여하여 관심장기에 대한 형태학적인 정보와 생물학적이고 기능적인 정보를 얻고 평가한다. Dose calibrator는 의료기관에서 단일 핵종의 방사능을 측정하기 위해 사용하는 장비이며, 방사성동위원소의 정확한 용량의 투여는 진단과 치료에 중요한 요인이다. 최근 정량분석을 위한 여러 시스템이 개발되고 있고 ERPF (Effective Renal Plasma Flow), GFR (Glomerular Filtration Rate) 등 정량분석이 필요한 검사에 있어서 정확한 투여 용량 및 재현성 있는 측정이 중요해지고 있다. 따라서 본 논문을 통해 Dose calibrator의 측정 깊이와 용량에 따른 선량 값의 성향을 알아보고 적절한 측정 깊이 및 용량에 대해 알아 보고자 한다. 실험에 사용한 Dose calibrator는 CRC-15R과 CRC-15βeta (Capintec, New Jersey, USA)를 사용하였다. 선원으로는 표준선원(Standard source) 137Cs, 133Ba, 57Co를 사용하였고, 방사성 의약품은 99mTc-pertechnetate를 사용하였다. 표준선원은 측정 깊이만 변화하여 0 cm부터 15 cm까지 1 cm 깊이마다 15회씩 측정했고, 99mTc-pertechnetate의 경우에는 1 mL 주사기로 표준선원과 동일한 깊이로 실험을 진행했고, 용량의 변화를 고려하여 0.1 mL, 0.3 mL, 0.5 mL, 0.7 mL, 0.9 mL로 각 깊이마다 15회씩 측정했다. 표준선원인 137Cs, 133Ba, 57Co의 깊이의 변화에서는 모두 깊이에 따른 선량 값의 변화가 통계적으로 유의한 차이가 있었다(p<0.05). 99mTc-pertechnetate도 깊이에 따른 용량의 변화에서 선량 값이 모두 통계적으로 유의한 차이가 있었다(p<0.05). CRC-15R의 표준선원 비교 그래프에서 137Cs, 133Ba, 57Co는 Plateau를 그리기 시작한 2 cm에서 9 cm까지는 각 선원마다 비교시 통계적으로 유의한 차이가 없었다(p>0.05). CRC-15βeta의 표준선원 비교 그래프에서는 Plateau를 그리기 시작한 영역은 3 cm에서 9 cm로 통계적으로 유의한 차이가 없었다(p>0.05). 99mTc-pertechnetate의 그래프는 0.1 mL에서 1 cm에서 7 cm, 0.3 mL와 0.5 mL에서는 0 cm에서 7 cm, 0.7 mL에서는 0 cm에서 6 cm, 0.9 mL에서는 0 cm에서 5 cm에서 통계적으로 유의한 차이가 나타나지 않았다(p>0.05). 본 연구를 통해 방사성동위원소를 환자에게 주입하거나 정도관리를 진행 시 편차가 적고 재현성을 위해 신뢰할 수 있는 구간을 확인 할 수 있었다. 높이에 따른 변화가 가장 적은 Plateau의 구간이 0.3 mL 혹은 0.5 mL의 용량으로 0 cm 에서 7 cm의 깊이에서 측정한다면, 편차를 최소한으로 줄일 수 있을 것으로 사료된다. 표준선원의 경우에는 본 연구의 결과에 따라 장비마다 Plateau의 변화가 가장 적은 구간의 깊이에서 재현성 있게 측정하는 것이 중요하다고 생각된다. 적절한 구간을 찾아서 재현성 있는 검사를 시행하면 검사의 품질향상 및 피폭선량저감 그리고 진단능을 높이는데 이바지 할 것이라고 생각된다.

Study on (n,p) reactions of 58Ni, 99Tc, 99Ru, 131Xe, 133Cs and 186Os radioisotopes used in medicine

  • Hallo M. Abdullah;Ali H. Ahmed
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.304-309
    • /
    • 2023
  • In the last decade, nuclear medicine appears to be a good choice of medicine. 58Co, 99Mo, 99Tc, 99Re, 133Xe and 186Re are very important radionuclides for nuclear medicine. In this study, the excitation functions of 58Ni (n, p) 58Co, 99Tc (n, p) 99Mo, 99Ru (n, p) 99Tc, 131Xe (n, p) 131I, 133Cs (n, p) 133Xe and 186Os (n, p) 186Re nuclear reactions were calculated at neutron energies between 1 and 20 MeV using TALYS 1.95 and EMPIRE 3.2 nuclear codes. Furthermore, the cross sections were calculated with the empirical formula derived in our past study at 14-15 MeV. The obtained results were compared with the measured values in EXFOR library, and with the evaluated data of (JENDL-4.0/HE, JEFF-3.3, TENDL-2019, ENDF/B-VIII.0, IRDFF-II, JENDL/ImPACT-18). The results are in good agreement with those of the evaluated data libraries and experimental results and indicates that these radioisotopes can be produced by smaller cyclotrons.

감마 카메라의 Flood Table에 대한 이해와 적절한 이용 (Comprehension and Appropriate Use of a Flood Table on a Gamma Camera)

  • 김재일;임정진;김진의;김현주
    • 핵의학기술
    • /
    • 제15권1호
    • /
    • pp.29-33
    • /
    • 2011
  • 감마 카메라 안에는 검출기의 감도를 균일하게 해주는 flood table이 내장되어있어 있는데, 우수한 균일성을 유지하기 위해서는 적합한 flood table을 사용하여야 한다. 왜냐면 flood table은 입사된 방사선의 종류와 에너지, 용량에 따라 차이가 나기 때문이다. 그래서 본 논문에서는 적절치 못한 flood table을 사용하였을 때, 영상의 균일성이 어떻게 변화하는지를 알아보겠다. 입사 방사선으로 $^{57}Co$, $^{99m}Tc$, $^{201}Tl$ 370 MBq를 사용하였다. Philips 사의 SkyLight, GE 사의 Infinia 감마 카메라를 사용하여. 각 선원 별로 각각 $^{57}Co$로 교정된 flood table, $^{99m}Tc$으로 교정된 flood table로 보정한 영상을 얻고, 균일성을 보정하지 않은 영상과 비교하였다. 추가적으로 콜리메이터를 장착한 상태에서 데이터를 얻고 내인성 flood table과 외인성 flood table로 보정 해보았다. 이렇게 나온 결과 영상을 가지고 균일도를 평가하였고, 그 값들을 서로 비교하였다. $^{57}Co$를 사용한 경우 보정을 하지 않았을 때 균일도는 9.34% 이고, $^{99m}Tc$ flood table로 보정하였을 때는 5.91%, $^{57}Co$ flood table일 경우 4.9%가 나왔다. $^{201}Tl$을 사용한 경우, 보정하지 않으면 9.81%, $^{99m}Tc$ flood table은 7.03%, $^{57}Co$ flood table은 7.49% 나왔다. $^{99m}Tc$을 사용한 경우, 무보정 시 9.67%, $^{99m}Tc$ flood table은 3.96%, $^{57}Co$ flood table은 5.69% 나왔다. 그리고 내인성 flood table로 보정을 한 경우 6.28% 나왔다. flood table이 입사된 방사선의 종류와 맞지 않는다면 균일도는 변화되는걸 알 수 있었고, 입사된 방사선과 flood table을 교정한 방사선원의 종류가 일치할 때, 감마 카메라의 균일도는 가장 좋음을 알 수 있다. 더불어 내인성, 외인성 시스템처럼 콜리메이터의 유무에 따라 다르게 교정한 flood table에 따라서도 균일도는 변화됨을 알 수 있다. 따라서 감마선을 받아 들이는 상황과 방사선원에 따라 일치한 flood table를 지정하여야 하고, 정기적으로 flood table을 개선시켜 주어야 높은 균일성을 유지 시킬 수 있을 것이다.

  • PDF

방사선 조사가 이하선 기능에 미치는 영향에 관한 연구 (IRRADIATION EFFECT ON SECRETING FUNCTION, AMYLASE ACTIVITY AND NUCLEIC ACID CONTENTS OF RAT PAROTID GLAND)

  • 조용진;박태원
    • 치과방사선
    • /
    • 제20권1호
    • /
    • pp.53-62
    • /
    • 1990
  • This experiment was performed to clarify the effects of /sup 60/Co gamma irradiation on secretory function, amylase activity and contents of nucleic acids of parotid gland in rat. Experimental animals were divided into 6th hours, 3rd, 7th, 14th and 28th days after irradiation and control. The experimental animals are singly irradiated with 20Gy (2,000rad) through protective lead block. Secretory function of parotid gland was evaluted by uptake and clearance of /sup 99m/TcO₄. /sup 99m/TcO₄. 0.2μ ci/gm, was injected into peritonium in uptake groups. Rats were sacrified with cervical dislocation after 30 minutes and gland was excised. In the clearance group. pilocarpine nitrate (8㎎/㎏) was intraperitoneally injected at 30 minutes after /sup 99m/TcO₄ injection and rats were sacrified 30 minutes after pilocarpine injection. Radioactivity of excised parotid gland was measured by using of gamma counter and stimulation-secretion coefficients, uptake radioactivity divided by clearance radioactivity, was calculated. Amylase activity and contents of DNA and RNA were determined by spectrophotometry. The results obtained were as follows: 1. In the uptake test, the radioactivity of /sup 99m/TcO₄ per unit weight increase in experimental group except 6th hours group, compared with control groups and showed a peak at 3rd days after irradiation. 2. In the clearance test, the radioactivity of /sup 99m/cO₄per unit weight rose to a peak at 3rd days after irradiation and gradually recovered thereafter. 3. Stimulation-secretion coefficient of parotid gland decreased at 6th hours, 3rd and 7th days after irradiation, and gradually increased. 4. Amylase activity of parotid gland decreased in 3rd and 7th days group, and especially lowest in 3rd days after irradiation. 5. The contents of DNA showed no definite difference in all the experimental groups, but RNA was seemed to decrease with time after irradiation.

  • PDF

$^{99m}Tc$-HMPAO의 광학이성체 d-, l-Form의 합성과 뇌섭취율 비교 (Synthesis of d- and l-Form of $^{99m}Tc$-HMPAO, and Comparison of Brain Uptake)

  • 강찬순;장영수;정재민;이동수;정준기;이강춘;이명철
    • 대한핵의학회지
    • /
    • 제35권1호
    • /
    • pp.69-74
    • /
    • 2001
  • 목적: $^{99m}Tc$-HMPAO는 뇌혈류영상에 사용되는 방사성의약품으로, HMPAO (RR,SS)-4,8-diaza-3,6,6,9-tetramethylundecan-2,10-dione bisoxime)는 3개의 입체이성체(meso-, d-, l-HMPAO)가 존재한다. $^{99m}Tc$표지 meso-HMAPO와 d,l-HMPAO는 체내에서 뇌섭취에 차이를 나타낸다. 이 연구에서는 d,l-HMPAO 입체이성체 혼합물을 d-형과 l-형으로 분리하여 각각을 $^{99m}Tc$으로 표지하여 생체내분포를 비교하고자 하였다. 대상및 방법: 2,3-Butanedione monooxime과 2,2-dimethyl-1,3-propanediamine을 반응시켜 imine 형태의 중간화합물(수율: 54%)을 얻었다. 이를 환원시켜 d,l-과 meso-HMAPO 혼합물을 얻었다(수율 : 31%). 이것을 4번 분별결정하여 miso-HMPAO를 분리하였다(수율: 11%). d,l-라세미 혼합불은 (+)-타르타르 산과 (-)-타르타르 산을 이용하여 d-형과 l-형을 분리하였다(수율 25%, 5%). 합성한 각 입체이성체 HMPAO를 환원제로 $SnCI_2{\cdot}2H_2O$를 이용하여 $^{99m}Tc$으로 표지한 후, 마우스에 투여하여 1 시간 후 생체내분포를 확인하였다. 결과: 우리는 각 입체이성체 HMAPO를 합성하고 핵자기공명분광기와 선광도측정기를 이용하여 구조를 확인하였다. $^{99m}Tc$ 표피후 지용성 $^{99m}Tc$HMPAO의 방사화학적 순도는 80% 이상이었다. 각 입체이성체(d,l-, d-, l- HMPAO)의 뇌섭취율은 1.34, 1.12, 1.67% ID/g으로, l-형이 d-형보다 1.5 배 더 높았다. 결론: 우리는 각 입체이성체 HMPAO를 성공적으로 합성하였다. l-HMPAO를 분리하여 사용할 경우 보다 나은 영상을 기대할 수 있을 것으로 생각한다.

  • PDF

Radiolabeling of antibody-mimetic scaffold protein with 99mTc tricarbonyl precursor via hexahistidine (His6)-tag

  • Shim, Ha Eun;Kim, Do Hee;Lee, Chang Heon;Choi, Dae seong;Lee, Dong-Eun
    • 대한방사성의약품학회지
    • /
    • 제5권1호
    • /
    • pp.11-17
    • /
    • 2019
  • Recently, antibody-like scaffold proteins have received a great deal of interest in diagnosis and therapy applications because of their intrinsic features that are often required for tumor imaging and therapy. Intrinsic issues that are associated with therapeutic application of antibody-like scaffold proteins, particularly in cancer treatment, include an efficient and straightforward radiolabeling for understanding in vivo biodistribution and excretion route, and monitoring therapeutic responses. Herein, we report an efficient and straightforward method for radiolabeling of antibody-like scaffold proteins with the $[^{99m}Tc(OH_2)_3(CO)_3]^+$ ($^{99m}Tc$-tricarbonyl) by using a site-specific direct labeling method via hexahistidine-tag, which is a widely used for general purification of recombinant proteins with His-affinity chromatography. Repebody is a new class of antibody-like scaffold protein that consists of highly diverse leucine-rich repeat (LRR) modules. Although all possible biomedical applications with repebody are ongoing, it's in vivo biodistribution and excretion pathway has not yet been explored. In this study, hexahistidine ($His_6$)-tag bearing repebody (rEgH9) was labeled with [$^{99m}Tc$]-tricarbonyl. Repebody protein was radiolabeled with high radiolabeling efficiency (>90%) and radiolabeled compound was more than 99% pure after purification. These results clearly demonstrate that the present radiolabeling method will be useful molecular imaging study.

Re-188과 Tc-99m 표지 단일클론항체 CEA79.4의 생체외 특성과 생체내 분포 (In Vitro Properties and Biodistribution of Tc-99m and Re-188 Labeled Monoclonal Antibody CEA79.4)

  • 홍미경;정재민;여정석;김경민;장영수;이용진;이동수;정준기;이명철;이승진
    • 대한핵의학회지
    • /
    • 제32권6호
    • /
    • pp.516-524
    • /
    • 1998
  • 목적: 현재 Re-188 표지 단일클론항체는 종양의 방사면역치료제로서 주목받고 있으며 많은 연구가 진행되고 있다. 이 연구에서는 골수성 백혈구 세포에 존재하는 NCA-95에 대한 단일클론항체 CEA79.4를 사용하여 Re-188의 항체 표지법을 개발하고 그 특성을 분석하여 Tc-99m 표지항체와 비교하고자하였다. 대상 및 방법: 표지는 항체에 방사성 핵종을 직접 붙이는 직접법을 사용하였다. 환원제인 ${\beta}$-mercaptoethanol로 단일클론항체 CEA79.4를 환원하여 SH-기를 생성시키고 여기에 발생기로부터 얻은 Tc-99m과 Re-188을 표지 하였다. Tc-99m의 표지를 위해서는 pH 6.5인 PBS에서 반응시켰으며 착화제와 환원제로 MDP kit를 사용하였다. Re-188은 50 mM acetate buffered saline (ABS, pH 5.3)에서 stannous tartrate를 환원제로 사용하여 표지 하였다. 표지효율은 ITLC로 확인하였으며 표지항체는 PD-10 칼럼을 이용하여 분리하였다. 분리한 표지항체를 1% 사람혈청 알부민과 비타민 C를 넣어 산화를 방지하고 실온과 사람혈청(5% $CO_2$, $37^{\circ}C$)에서 안정성 검사를 실시하였다. 대장암세포주인 SNU-C4와 세포결합검사를 실시하여 면역반응성과 항원에 대한 친화상수를 측정하였다. 또한 정상 ICR 마우스에 꼬리정맥으로 주사하여 1, 14, 24시간에 체내분포를 보았다. 결과: Tc-99m의 항체 표지효율은 $92.4{\pm}5.9%$ (n= 15)이고 Re-188은 $84.7{\pm}4.6%$ (n=4)로 우수한 표지효율을 보였다. 표지항체의 체외안정성검사를 실시한 결과 실온에서는 Tc-99m 표지항체의 경우 24시간까지 90% 정도로 안정하였으나 Re-188 표지항체는 70% 정도를 유지하였다. 사람혈청에서는 Tc-99m 표지항체는 24시간에 60% 이상이었으나 Re-188은 50% 이하로 낮았다. Tc-99m과 Re-188의 표지항체의 면역반응성은 각각 59.2%, 41.6%, 친화상수는 $6.59{\times}10^9\;M^{-1}$, $4.2{\times}10^9\;M^{-1}$ 이었다. 또한 정상 마우스에서 체내 분포는 비 특이적으로 집적되지 않고 배설되어 유사한 경향을 보였다. 결론: 기존의 Tc-99m 표지법과 같은 원리를 이용하여 단일클론항체 CEA79.4를 Re-188과 표지하였다. Re-188-CEA79.4는 면역반응성과 친화력등 체외 면역학적 특성과 체내분포에서 Tc-99m 표지항체와 큰 차이를 보이지 않았다. 따라서 Re-188-CEA79.4는 골수성 백혈병, 림프종 등 질병의 방사면성역치료에 적용 할 수 있을 것이다.

  • PDF

고(高)에너지 방사선(放射線) 조사(照射)가 가토(家兎) 간장(肝臟)에 미치는 영향(影響)에 관(關)한 핵의학적(核醫學的) 연구(硏究) (A Nuclear Medicine Study on the Effect of High Energy Gamma Irradiation on Rabbit Liver)

  • 이준일;민봉희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제12권1호
    • /
    • pp.3-16
    • /
    • 1989
  • In order to investigate the in vivo effect of $^{60}Co$ radiation on rabbit liver, the uptake ratio and regional excretory value in hepatocytes and Kupffer cells were estimated during acute and chronic hepatic injuries. The left lobe of liver was irradiated at 15 Gy or 30 Gy with a single dose and subsequent changes were analysed with a seial nuclear medicine imaging by using $^{99m}Tc-phytate,\;^{99m}Tc-DISIDA\;and\;^{99m}Tc-HSA$ and resulting data were computerized. The degree of hepatic damage, duration of the injury, and recovery pattern after the irradation were in agreement with the findings of other investigations. However, out values were more quantitative evacuation than those of other publications. Recovery of decreased uptake of $^{99m}Tc-phytate$ was delayed approximately $2{\sim}3$ days later than that of $^{99m}Tc-DISIDA$. In acute radiation induced injury, the results demonstrated that the recovery of Kupffer cells was delayed more than that of hepatocytes. This discrepancy was considered due to the differences in repair activities between these cell types. The decreased of regional excretory value in irradiated area was found to be dose-dependent but had no corelation with regional uptakes of DISIDA and phytate. The decreased of regional excretory value observed in non-irradiated region suggested that irradiated liver might induce an indirect effect.

  • PDF