• Title/Summary/Keyword: $^{99}Tc$

Search Result 1,454, Processing Time 0.036 seconds

Comparison of Ga-67, Tl-201 and Tc-99m MIBI Imaging in Lymphoma Patients (림프종 환자에서의 갈륨, Tl-201 그리고 Tc-99m MIBI 섭취의 비교)

  • Chun, Kyung-Ah;Cho, Ihn-Ho;Won, Kyu-Chang;Lee, Kyung-Hee;Lee, Hyung-Woo;Hyun, Myung-Soo;Lee, Jae-Tae;Lee, Kyu-Bo
    • Journal of Yeungnam Medical Science
    • /
    • v.19 no.2
    • /
    • pp.107-115
    • /
    • 2002
  • Purpose: Ga-67 scintigraphy has been used for the evaluation of tumors, especially lymphoma. Recently, Tl-201 and Tc-99m MIBI were also used to tumor imaging. Tl-201 and Tc-99m MIBI had better physiologic characteristics than Ga-67, so we studied 32 biopsy proven lymphoma patients (male 24, female 8, mean age 46 years) with Ga-67, Tl-201 or Tc-99m MIBI and compared the scan findings. Materials and Methods: Twenty-three of 32 patients were injected 74-111 MBq (2-3 mCi) of Tl-201, before chemotherapy and imaged with dual-headed SPECT (Prism 2000, Picker, USA) at 30 minutes after injection. Delayed images were obtained after 3 hr in 8 patients. Twenty seven of 32 patients were injected 740 MBq (20 mCi) of Tc-99m MIBI and imaged at 30 minutes after injection. 111-185 MBq (3-5 mCi) of Ga-67 was injected in 12 patients and imaged at 48 and 72 hours after injection. Twenty eight patients were diagnosed as non-Hodgkin's lymphoma and others were Hodgkin's lymphoma. Results: Twenty patients were positive on Tl-201 scan and 3 patients showed negative findings. One of these 3 patients, Tc-99m MIBI and Ga-67 scan were positive. Twenty two patients were positive on Tc-99m MIBI scan and 5 patients showed negative findings. One of these 5 patients, Tl-201 was positive and 2 were positive on Ga-67 scan. Ten of 12 patients showed positive findings on Ga-67 scan. The sensitivity of these agents were 83.3%, 87.0% and 81.5% for Ga-67, Tl-201 and Tc-99m MIBI, respectively. The sensitivity was highest in Tl-201 scan, but there were no significant differences among three tests. In this study, there was no significant difference of uptake ratios between early and delayed images of Tl-201. Conclusion: Scintigraphy with Tl-201 and Tc-99m MIBI in lymphoma patients have similar sensitivity with Ga-67.

  • PDF

Glomerular Filtration Rate Measurements Using $^{99m}$Technetium-mercaptoacetyltriglycine Dynamic Renal Scintigraphy in Children with Renal Disease (신장 질환이 있는 소아에서 $^{99m}$Technetium-mercaptoacetyltriglycine ($^{99m}Tc$-MAG3) 신장 스캔에 의한 사구체 여과율 측정)

  • Yoon, In Ae;Yun, Ki Wook;Lim, In Seok;Choi, Eung Sang;Yoo, Byung Hun
    • Childhood Kidney Diseases
    • /
    • v.17 no.2
    • /
    • pp.57-64
    • /
    • 2013
  • Purpose: In children, 24-hour urine collections are unreliable for evaluating glomerular filtration rate (GFR) because of the difficulty of regulating voiding and the daily variation of urinary creatinine up to 25%. Additionally, creatinine clearance (Ccr) based on urinary creatinine is considered inaccurate. The purpose of this study was to compare estimated GFR determined using Ccr, formulas with serum cystatin C and creatinine, and $^{99m}Tc$-mercaptoacetyltriglycine (MAG3) dynamic renal scintigraphy. Methods: This retrospective study included 101 patients (age, <18 years) who visited Chung-Ang University Hospital between July 2011 and August 2012. GFR was estimated using 24-hour urinary creatinine, five formulas with serum creatinine and cystatin C, and $^{99m}Tc$-MAG3 renal scan. Results: Of the 101 patients, glomerular renal diseases were present in 60 patients (59.4%) and non-glomerular diseases were present in 41 patients (40.6%). There was a significant correlation between estimated GFR determined using $^{99m}Tc$-MAG3 renal scan and Ccr (r=0.389, P <0.001). The correlation values between estimated GFR determined using $^{99m}Tc$-MAG3 renal scan and each formula of Schwartz, Counahan-Barratt, Cockcroft-Gault, Filler and Lepage, and Bokencamp were 0.265 (P=0.007), 0.128 (P=0.044), 0.230 (P=0.021), 0.356 (P<0.001), and 0.355 (P <0.001), respectively. $^{99m}Tc$-MAG3 renal scan was correlated with estimated-GFR by all formulas in decreased renal function. Conclusion: Estimated GFRs determined using serum creatinine and cystatin C, and $^{99m}Tc$-MAG3 renal scan correlated well with estimated GFR determined using Ccr. $^{99m}Tc$-MAG3 renal scan may be replaced for evaluation of renal function with convenience in patients with renal disease and decreased renal function in childhood.

Studies on the Preparation of $^{99m}TC$ Labelled Antimony Sulfide Colloid and Hydroxyethyl Starch for Lymphoscintigraphy (림포신티그래피용 $^{99m}TC$를 표지황화안티몬 콜로이드 및 전분의 제조에 관한 연구)

  • Park, Kyung-Bae;Awh, Ok-Doo;Kim, Jae-Rok;Lim, Sang-Moo;Hong, Seong-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.1
    • /
    • pp.71-83
    • /
    • 1989
  • For the development of $^{99m}Tc-labelled$ antimony sulfide colloid and hydroxyethyl starch, various experiments such as preparation of colloid, control of the distribution of particle size, establishment of labelling conditions, determination of labelling yield and radiochemical purity, examination of stability, and organ imagings of rabbits etc. were carried out. 1) Antimony sulfide colloid was readily prepared by the reaction of aqueous solution of antimony potassium tartrate with hydrogen sulfide generated by treating ferrous sulfide with dilute sulfuric acid. The colloid could be stabilized by adding small amount of polyvinylpyrrolidone. 2) Electron microscopy analysis exhibited the distribution of colloid size in the range of $1\sim15nm$ with a major portion of 9 m. The colloid solution was sterilized by membrane filtration $(0.2{\mu}m)$ and then stored at $4^{\circ}C$. This sterilized colloid was so stable that it was usable at least for one year. 3) The antimony sulfide colloid was labelled by adding sodium $pertechnetate-^{99m}Tc$ solution to the reaction vial, followed by adding hydrochloric acid and then boiled for 30 min. The optimal pH of the reaction mixture was found to be in the range of $1.3\sim1.4$. Instant thin layer chromatography (ITLC) analysis showed high labelling yield of above 99.5%. This labelled colloid maintained high radio-chemical purity of above 99% until 10 hours after labelling. 4) Animal studies showed high uptake of $^{99m}Tc-Sb_2S_3$ colloid at lymph vessels and nodes indicating a suitable agent for lymphoscintigraphy. Satisfactory results were also abtained in other clinical studies. 5) Hydroxyethyl starch (HES $0.6\sim1.0%$) was labelled with $Na^{99m}TcO_4$ in the presence of $SnCl_2$ with high labelling yield of above 99.5%. The optimal pH of the reaction mixture was in the range of $1.8\sim2.0$. $^{99m}Tc-HES$ maintained high radiochemical purity of above 99% until 10 hours after labelling. 6) Animal studies showed that $^{99m}Tc-HES$ migrated more rapidly from the injection sites into the lymph vessels than $^{99m}Tc-Sb_2S_3$ colloid while less amount of the former was uptaken at lymph nodes than that of the latter. Similar phenomenon was also observed in other clinical studies. As a result, $^{99m}Tc-Sb_2S_3$ colloid was found to be more effective lymphoscintigraphic agent than $^{99m}Tc-HES$.

  • PDF

International Standards of IEC TC64 & TC99 apply to Technical Regulation in Korea Electricity Business Act (전기설비기술기준에 도입되는 IEC TC64 및 TC99 규격)

  • Kim, Kwang-Deok
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.220-222
    • /
    • 2004
  • The IEC standards related to the Technical Regulation in Korea Electricity Business Act are classified into the standards/guides for electrical system and the specifications for electrical equipment/materials. IEC Standard 60364 "Electrical Installations of Buildings" and IEC Standard 61936 "Power Installations Exceeding 1 kV AC" prepared by IEC Technical Committee(TC) 64 and TC 99 respectively, are representative standards for electrical installations of buildings, substations, industrial plants, etc.

  • PDF

Estimation of the Arterial Fraction of Total Hepatic Flow from Radionuclide Angiogram Using $^{99m}Tc-DISIDA$ ($^{99m}Tc-DISIDA$를 이용한 간 혈류 중 동맥 분획의 측정)

  • Lee, Hae-Giu;Lim, Gye-Yeon;Yang, Il-Kwon;Kim, Hack-Hee;Lim, Jung-Ik;Bahk, Yong-Whee;Han, Sok-Won;Han, Nam-Ik;Lee, Young-Sok
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.200-206
    • /
    • 1991
  • Arterial fraction of total hepatic blood flow was estimated by a new method, slope method, on radionuclid angiogram using $^{99m}Tc-DISIDA$ and was compared with that from $^{99m}Tc-Phytate$ radionuclide angiogram. This study included 11 of normal subjects, 37 of intermediate group with various liver diseases, and 25 patients with liver cirrhosis. We analyzed the datas with slope method from radionuclide angiograms and the results were compared with hepatic arterial fractions from uptake method, introduced by Lee et al. at 1986. The hepatic arterial fractions from radionuclide angiograms using $^{99m}Tc-DISIDA$ and $^{99m}Tc-Phytate$ were $0.32{\pm}0.09\;and\;0.31{\pm}0.11$ respectively in normal subjects, and $0.75{\pm}0.18\;and\;0.77{\pm}0.21$ respectively in patients with liver cirrhosis. The hepatic arterial fractions by the slope method was well correlated with those of the uptake method on $^{99m}Tc-DISIDA$ scan. There was high correlation between the hepatic arterial fractions from $^{99m}Tc-DISIDA$ and $^{99m}Tc-Phytate$ scans. Hepatic arterial fraction estimated by the slope method is a useful index for the diagnosis of liver cirrhosis and the evaluation of status of portal hypertension.

  • PDF

A Study on Comparative Analysis of Mammography and Tc-99m MIBI Scintimammography for Dense Breast (치밀형 유방에서 유방특이감마영상검사의 유용성 평가)

  • Jeong, Eun-Mi;Kim, Ho-Seong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.76-79
    • /
    • 2012
  • Purpose: This study was to evaluate usefulness of $^{99m}Tc$-MIBI scintimammography for dense breast by comparing concordance in test results between Tc-99m MIBI scintimammography and mammography whose effect was proved the most as an imaging tool depending on breast density and at the same time by examining limitation on evaluation depending on density of breast tissue. [Materials and Methods] In the period from December 2010 to July 2011, this study targeted 150 patients who took both of $^{99m}Tc$-MIBI scintimammography and mammography conducted by using breast gamma camera in this hospital. Breast density was classified to the four levels of pattern 1~4 based on the results of mammography. $^{99m}Tc$-MIBI scintimammography was conducted with the LCC, the RCC, the LMLO, and the RML one minute after intravenous injection of 99mTc-MIBI 7400 MBq (20 mCi) while analysis was made for concordance in test results of $^{99m}Tc$-MIBI scintimammography and mammography. [Results] Among the 150 patients, pattern 1 was found in 3 patients, pattern 2 in 44 patients, pattern 3 in 61 patients, and pattern 4 in 37 patients. There were 5 patients who showed the case where it was impossible to determine density of breast tissue due to foreign body inserted to breast. The concordance ratio of the results between $^{99m}Tc$-MIBI scintimammography and mammography was 95.5% for pattern 2, 95.1% for pattern 3 and 94.6% for pattern 4. This demonstrated that the concordance rate decreased according to the increase in breast density. [Conclusion] When there was limitation on evaluation of breast specific gamma imaging test results due to increased intake in breast tissue or surgical site, the concordance rate was 6.8% for pattern 2, 16.3% for pattern 3 and 18.9% for pattern 4. This demonstrated that the degree of limitation on evaluation of breast specific gamma imaging test results increased according to the increase in breast density.

  • PDF

Biodistribution Study of $^{99m}Tc$-Labeled Succinic Acid-Conjugated Low pI Avidin (낮은 동전점을 갖는 $^{99m}Tc$ 표지 Succinic Acid 결합 Avidin의 생체내분포에 관한 연구)

  • Jeong, Jae-Min;Paik, Chang-H.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.285-292
    • /
    • 1993
  • Avidin과 biotin의 높은 결합력을 이용하여 종양 영상을 개선하는 방법이 많이 연구되고 있다. 본 실험에서는 이러한 목적으로 쓰기 위하여 적당한 $^{99m}Tc$ 표지 avidin을 제조하였다. Avidin을 표지하기 위하여 우선 $^{99m}Tc$과 안정한 킬레이트를 형성할 수 있는 benzoylmercaptoacetyltriglycine (Bz-MAG3)과 biocytin을 화학적으로 결합시킨 Bz-MAG3-biocytin을 합성하였다. 이 화합물을 Tc-99m으로 표지시켜 avidin 또는 streptavidin을 1:1로 섞어 줌으로서 Tc-99m으로 표지된 avidin과 streptavidin을 제조하였다. 이들의 생쥐 생체내 분포를 조사한 결과 avidin의 경우 높은 간(56.6%, 10min)과 신장(28.5%, 10min) 축적을 보였고 streptavidin의 경우 높은 신장 축적 (28.9%, 21hr)을 보였다. Avidin의 높은 정상 조직 축적을 줄이기 위하여 succinic acid를 결합시켜 등전점(pI)을 낮춘 다음 같은 실험을 하여 본 결과 신장 축적율은 pI가 $7.0{\sim}9.3,\;5.5{\sim}6.2,\;4.0{\sim}4.8$로 낮아졌을 경우 19.0%, 3.1%, 1.7%로 각각 떨어졌지만 간에의 축적은 pI 변화에 따른 상관성을 찾아 볼 수가 없었다. 체내 제거율을 측정하여 본 결과 pI를 변화시킨 avidin과 변화시키지 않은 avdin들은 반감기가 13.5에서 16.0시간 사이로 큰 차이점을 보이지 않았는데 streptavidin은 반감기 61.5시간 정도로 느리게 제거된다는 것을 알았다. 이 실험의 결과 1. Avidin을 $^{99m}Tc$-MAG3-biocytin으로 안정하게 표지할 수 있었고, 2. pI가 낮아진 avidin은 신장에의 축적율이 크게 감소되었으며, 3. $^{99m}Tc$으로 표지된 avidin과 streptavidin은 먼저 간으로 흡수된 후 대사된 다음 신장으로 배설된다는 사실을 알았다.

  • PDF

A Case of Hepatopulmonary Syndrome Diagnosed by $^{99m}Tc-MAA$ Perfusion Lung Scan ($^{99m}Tc-MAA$ 폐관류스캔으로 진단한 간폐증후군)

  • Oh, Hyung-Tae;Lee, Moo-Yong;Song, Il-Han;Park, Seok-Gun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.3
    • /
    • pp.203-208
    • /
    • 2002
  • In patients with chronic liver disease, hepatopulmonary syndrome, the right to left shunt without previous pulmonary and cardiac disease, can develope and cause respiratory distress. Tools to prove shunt are contrast echocardiography, pulmonary angiography, and $^{99m}Tc-MAA$ perfusion lung scan. Among them, $^{99m}Tc-MAA$ scan is a simple and safe method detecting the right to left shunt. At the same time, quantitation of shunt amount is possible by this method. We report a case of hepatopulmonary syndrome confirmed by $^{99m}Tc-MAA$ scan and contrast echocardiography with review of literlatures.

Detection of Occult Thymoma Using Tc-99m tetrofosmin Scintigraphy (Tc-99m tetrofosmin 신티그래피로 우연히 발견된 흉선암종)

  • Kwon, Seong-Young;Jeong, Shin-Young;Seo, Young-Soon;Ha, Jung-Min;Chong, A-Ri;Oh, Jong-Ryool;Song, Ho-Chun;Min, Jung-Joon;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.259-260
    • /
    • 2008
  • Tetrofosmin is a ligand that forms a lipophilic, cationic complex with Tc-99m. Tc-99m tetrofosmin was developed as a myocardial perfusion imaging agent and also used to depict tumors. Mediastinal tumors is also detected by Tc-99m tetrofosmin. We report a case of extracardiac mediastinal activity detected by Tc-99m tetrofosmin scintigraphy, which revealed thymoma.

Influence of Iodinated Magnetic Resonance Contrast Media and Isotope 99mTc on Changes of Computed Tomography Number

  • Kim, Sang-Beom;Lee, Jin-Hyeok;Ahn, Jae-Ouk;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.302-307
    • /
    • 2015
  • The purpose of the study was to identify how isotope and magnetic resonance imaging (MRI) contrast media impact on noise to computed tomography (CT) examination. For the study, divide the phantoms to two groups: 1) saline, saline + different kinds of contrast agent without $^{99m}Tc$ administration; 2) $^{99m}Tc$ administration: saline, saline + different kinds of contrast agent with $^{99m}Tc$ administration. CT contrast agent was used for Iopamidol$^{(R)}$ and Dotarem. And MRI contrast agent was used for Primovist$^{(R)}$ and Gadovist$^{(R)}$. To obtain an image, we used CT scanner. With an obtained image, we set the $1cm^2$ region of interest in the middle of bottle to measure the noise and CT number. As a result, there was no difference in CT number before and after inserting $^{99m}Tc$ into all contrast media including Normal Saline. However, when it comes to Noise, there was a difference before and after inserting $^{99m}Tc$ into every contrast media except MRI contrast media such as Primovist$^{(R)}$ and Gadovist$^{(R)}$.