• Title/Summary/Keyword: $^{90}Y$

Search Result 36,066, Processing Time 0.056 seconds

Investigation of sequential separation method for $^{90}Sr,\;^{241}Am,\;^{239,240}Pu$ and $^{238}Pu$ isotopes ($^{90}Sr,\;^{241}Am,\;^{239,240}Pu$$^{238}Pu$ 동위원소들을 분리하기위한 축차분리법에 대한 고찰)

  • Lee Myung-Ho;Song Byoung-Chul;Park Young-Jai;Gee Kwang-Young;Kim Wein-Ho
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.248-254
    • /
    • 2005
  • This paper presents a quantitative method of sequential separation of $^{90}Sr,\;^{241}Am$ and Pu nuclides with an anion exchange resin and a Sr-Spec resin. The Pu isotopes were purified with an anion exchange resin. The americium and strontium fractions were separated from the matrix elements with an oxalate co-precipitation method. Americium fraction was separated from the strontium fraction with iron co-precipitation method and purified from lanthanides with anion exchange resin. Strontium-90 was purified from other hindrance elements with the Sr-Spec resin after oxalate co-precipitation. The measurement of Pu and Am isotopes was carried out by an ${\alpha}$-spectrometer. Strontium-90 was measured by a liquid scintillation counter. The radiochemical procedure of $^{90}Sr,\;^{241}Am$ and Pu nuclides investigated in this study has been validated by application to IAEA-Reference soils.

  • PDF

Inhibition of p90RSK activation sensitizes triple-negative breast cancer cells to cisplatin by inhibiting proliferation, migration and EMT

  • Jin, Yujin;Huynh, Diem Thi Ngoc;Kang, Keon Wook;Myung, Chang-Seon;Heo, Kyung-Sun
    • BMB Reports
    • /
    • v.52 no.12
    • /
    • pp.706-711
    • /
    • 2019
  • Cisplatin (Cis-DDP) is one of the most widely used anti-cancer drugs. It is applicable to many types of cancer, including lung, bladder, and breast cancer. However, its use is now limited because of drug resistance. p90 ribosomal S6 kinase (p90RSK) is one of the downstream effectors in the extracellular signal-regulated protein kinases 1 and 2 (ERK1/2) pathway and high expression of p90RSK is observed in human breast cancer tissues. Therefore, we investigated the role of p90RSK in the Cis-DDP resistance-related signaling pathway and epithelial-mesenchymal transition (EMT) in breast cancer cells. First, we discovered that MDA-MB-231 cells exhibited more Cis-DDP resistance than other breast cancer cells, including MCF-7 and BT549 cells. Cis-DDP increased p90RSK activation, whereas the inactivation of p90RSK using a small interfering RNA (siRNA) or dominant-negative kinase mutant plasmid overexpression significantly reduced Cis-DDP-induced cell proliferation and migration via the inhibition of matrix metallopeptidase (MMP)2 and MMP9 in MDA-MB-231 cells. In addition, p90RSK activation was involved in EMT via the upregulation of mRNA expression, including that of Snail, Twist, ZEB1, N-cadherin, and vimentin. We also investigated NF-κB, the upstream regulator of EMT markers, and discovered that Cis-DDP treatment led to NF-κB translocation in the nucleus as well as its promoter activity. Our results suggest that targeting p90RSK would be a good strategy to increase Cis-DDP sensitivity in triple-negative breast cancers.

Effects of Aromatics and T90 Temperature of Low Cetane Number Fuels on Exhaust Emissions in Low-Temperature Diesel Combustion (저온디젤연소에서 저세탄가 연료의 방향족 및 T90 온도가 배기가스에 미치는 영향)

  • Han, Man-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.12
    • /
    • pp.1121-1126
    • /
    • 2010
  • This study is to investigate the effects of aromatics and T90 for low cetane number (CN) fuels on combustion and exhaust emissions in low-temperature diesel combustion. We use a 1.9-L common rail direct injection diesel engine at 1500 rpm and 2.6 bar BMEP. Low temperature diesel combustion was achieved via a high external EGR rate and strategic injection control. The tested fuels four sets: the aromatic content was 20% (A20) or 45% (A45) and the T90 temperature was $270^{\circ}C$ (T270) or $340^{\circ}C$ (T340) with CN 30. Given the engine operating conditions, the T90 was the stronger factor on the ignition delay time, resulting in a longer ignition delay time for higher T90 fuels. All the fuels produced nearly zero PM because of the extension of the ignition delay time induced by the low cetane number. The aromatic content was the main factor that affected the NOx and the NOx increased with the aromatic content.

Psychological Assessment of Patients with Iatrogenic Trigeminal Nerve Injury Using Symptom Checklist-90-Revised

  • Park, Mi-Sun;Roh, Byung-Yoon;Ahn, Jong-Mo;Yoon, Chang-Lyuk;Ryu, Ji-Won
    • Journal of Oral Medicine and Pain
    • /
    • v.40 no.1
    • /
    • pp.35-40
    • /
    • 2015
  • Purpose: This study aims to assess the psychological characteristics of patients with iatrogenic damage of the trigeminal nerve using Symptom Checklist-90-Revised (SCL-90-R). Methods: A total of 22 patients who visited the clinic of Department of Oral Medicine, School of Dentistry, Chosun University were evaluated in the months from December 2012 to December 2014. Patients were included in the study if they presented with reported sensory changes due to iatrogenic trigeminal nerve injury. A total of 37 control group who has no symptoms of pain and sensory change were included in the study. All participants filled out the SCL-90-R instrument to assess psychosocial symptoms. Results: The T-scores of most of the SCL-90-R symptom dimensions were within normal range (less than 55) in the patients and the control group. The patients group showed higher T-scores of SCL-90-R than those of the control group, with statistically significance of somatization, anxiety, psychoticism, and positive symptoms distress. Female patients group had higher Tscores of SCL-90-R than those of male patients group, but there was no statistical difference, except for the positive symptom global index. The chronic patients group showed higher Tscores of SCL-90-R than those of the acute patients group, but there was no statistical difference, except for the Positive symptom global index. Conclusions: According to the psychological assessment of iatrogenic trigeminal nerve injury patients using SCL-90-R, the patients group, as compared to the control group shows a significantly higher score for somatization, anxiety, and psychoticism. Therefore, assessment of psychological state would be considered to treat patients with iatrogenic trigeminal nerve injury.

Compact and Broadband 90° Coupler Using a Metamaterial (메타 물질을 이용한 초소형, 광대역 90° 커플러)

  • Kim, Hong-Joon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.7
    • /
    • pp.844-847
    • /
    • 2012
  • By using LHTL(Left-Handed Transmission Line) which is a form of a metamaterial and conventional RHTL (Right-Handed Transmission Line), we designed, fabricated and tested a broadband $90^{\circ}$ coupler which is a basic circuit for I-Q vector signal generation. Synthetic LHTL and RHTL were implemented with capacitors and inductors only, that the size is minimized. Also, by implementing a Wilkinson power divider which is required for the suggested circuit using a synthetic RHTL, the size of whole circuit is only $11mm{\times}12mm$. For the frequency range 0.8~1.25 GHz, the phase difference at the outputs maintained $90^{\circ}{\pm}5^{\circ}$ and thus, a broadband $90^{\circ}$ coupler could be made in a compact form. for the same frequency range, the insertion loss is less than 1.6 dB and return loss is more than 10.1 dB. To the best of our knowledge, this is the smallest and broadband $90^{\circ}$ coupler for the frequency range and if the circuit is made with MMIC(Monolithic Microwave Integrated Circuit) technology, the size will be reduced much further.

Sequential separation of 90Sr, 241Am, 239,240Pu and 238Pu by radioanalytical techniques (방사능 분석기술을 이용한 90Sr, 239,240Pu, 238Pu, 241Am 축차분리)

  • Lee, Myung Ho;Park, Kyoung Kyun;Kim, Jong-Yun;Park, Yeong Jae;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.469-474
    • /
    • 2005
  • This paper presents a quantitative method of sequential separation of $^{90}Sr$, $^{241}Am$ and Pu radionuclides with an anion exchange resin and a Sr-Spec resin. The Pu isotopes were purified with an anion exchange resin. The americium and strontium fractions were separated from the matrix elements with an oxalate co-precipitation method. Americium fraction was separated from the strontium fraction with iron co-precipitation method and purified from lanthanides with anion exchange resin. Strontium-90 was purified from other hindrance elements with the Sr-Spec resin after oxalate co-precipitation. The measurement of Pu and Am isotopes was carried out by an ${\alpha}$-spectrometer. Strontium-90 was measured by a liquid scintillation counter. The radiochemical procedure of $^{90}Sr$, $^{241}Am$ and Pu radionuclides investigated in this study has been validated by application to IAEA-Reference soils.

Thermoluminescent Response of Thin LiF:Mg,Cu,Na,Si Detectors to Beta Radiation (얇은 LiF:Mg,Cu,Na,Si 검출기의 베타선장에 대한 TL 반응)

  • Nam, Y.M.;Kim, J.L.;Chang, S.Y.;Cho, H.W.;Kim, H.J.
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.1
    • /
    • pp.39-43
    • /
    • 1999
  • Thermoluminescent (TL) response characteristics of a thin LiF:Mg,Cu,Na,Si Teflon detectors have been studied for use in beta radiation detection. The detectors were fabricated from a mixture of LiF:Mg,Cu,Na,Si phosphor and Teflon powder which was molded into a thin disk form of $50mg/cm^2$ thickness. These detectors were irradiated to beta fields of $^{147}Pm,\;^{204}Tl\;and\;^{90}Sr/^{90}Y$ sources with a covering of Kapton foil ($2mg/cm^2$) and photon irradiation was carried out with a $^{137}Cs$ source at the Korea Atomic Energy Research Institute (KAERI). Batch uniformity was estimated to be 4.7% and the beta dose response presented linear relationship from 0.1 mGy to 100 Gy. The beta energy responses of thin detectors normalized to $^{137}Cs$ were presented as 0.46, 1.09 and 1.06 for $^{147}Pm,\;^{204}Tl\;and\;^{90}Sr/^{90}Y$ beta rays, respectively. The evaluated values for angular responses were $0.93{\pm}0.03\;(^{147}Pm),\;0.94{\pm}0.04\;(^{204}Tl),\;and\;0.92{\pm}0.05\;(^{90}Sr/^{90}Y)$. The results satisfied well a proposed ISO Standard for beta ray dosimeters.

  • PDF

도서자료

  • 한국레미콘공업협회
    • 레미콘
    • /
    • no.4 s.71
    • /
    • pp.90-90
    • /
    • 2002
  • PDF