$^{68}Ga$ has emerged as a promising candidate for non-invasive diagnostic imaging within Positron Emission Tomography (PET) because of its advantageous radiochemical characteristics ($t_{1/2}=68min$, ${\beta}^+$ yield ~89%). $^{68}Ga$ forms a stable chelation with various ligands and it is possible to be quickly and easily study using a $^{68}Ge/^{68}Ga$ generator. Commercial $^{68}Ge/^{68}Ga$ generators are chromatographic system using the inorganic materials such as alumina and tin dioxide which are employed as column matrixes for $^{68}Ge$. In this study, we tried out to make $^{68}Ge/^{68}Ga$ generator system with the $^{68}GeO_2$ microstructures for column matrix. $^{68}Ge$ tends to have stable bond with oxide as $^{68}GeO_2$ microstructures. The $^{68}GeO_2$ has been synthesized by hydrolysis of $GeCl_4$ (sol-gel method) and characterized by X-ray diffraction and scanning electron microscope for geometrical analysis. The stability of $GeO_2$ was tested using eluents with diverse solvents(water, ethanol and 0.1 N HCl). The radioactivity of $^{68}Ga^{3+}$ in eluate through $GeO_2$ was measured to prove a function as column material for a generator.
Lee, Heung Nae;Kim, Sang Wook;Park, Jeong Hoon;Kim, Injong;Yang, Seung Dae;Hur, Min Goo
방사선산업학회지
/
제5권2호
/
pp.101-106
/
2011
The separation of germanium and gallium ion with metal oxide was introduced into the development of $^{68}Ge/^{68}Ga$ generator. Germanium and gallium within mixed solution were respectively separated by using a liquid-liquid extraction and a column chromatographic method. The separation of Ge within high concentrated hydrochloric and sulfuric acid was conducted by the extraction to $CCl_4$ and the back-extraction to 0.05 M HCl. An optimum condition of the extraction by $CCl_4$ was in 5~7 M HCl and efficiency was around 80%. The gallium was selectively separated by using $Al_2O_3$ among metal oxides as sorbents from the mixed solution in 0.04~0.10 M HCl condition.
In order to investigate the effect of Ge addition to the Cu Matrix on the microstructure and the critical current density, four kinds of internal tin processed Nb$_3$Sn strands with pure Cu and Cu 0.2, 0.4, 0.6 wt% Ge alloy were drawn to 0.8 mm diameter. The microstructure and critical current of internal tin processed Nb$_3$Sn wires that were heat treated at temperatures ranging from 68$0^{\circ}C$ to 74$0^{\circ}C$ for 240 h were investigated. The Ge addition to the matrix did not make workability worse. A Ge rich layer in the Cu-Ge matrix suppressed the growth of the Nb$_3$Sn layer and promoted grain coarsening. The greater the Ge content in the matrix, the lower the net Jc result after Nb$_3$Sn reaction heat treatment. There was no significant variation in Jc observed with heat treatment temperature ranging from 68$0^{\circ}C$ to 74$0^{\circ}C$.
목적: CT를 사용한 측정감쇠보정(measured attenuation correction; CT-MAC) PET 영상은 $^{68}Ge$을 사용한 분할감쇠보정(segmented attenuation correction; Ge-SAC) PET 영상보다 섭취값이 높은 것으로 알려져 있다. 이 연구에서는 정상인과 암으로 진단된 또는 암이 의심되는 환자를 대상으로 $^{18}F-FDG$ PET을 시행하고, 감쇠보정방법을 달리하여 각각 4가지 PET 영상을 얻고 이를 서로 정량적으로 비교하였다. 대상 및 방법: 5명의 정상인(남:여=4:1; 평균나이, $29.4{\pm}2.5$세)과 35명의 환자(남17, 여18; 평균나이 $52.7{\pm}15.2$세)를 대상으로 $^{18}F-FDG$ PET을 시행하였다. 먼저, CT 영상(140 KeV, 80 mAs)을 얻은 뒤 방출영상(5 min/bed)과 $^{68}Ge$ 투과영상(3 min/bed)을 차례로 얻었다. Ordered subsets expectation maximization (28 subsets, 2 iterations) 영상재구성법과 CT-MAC, CT-SAC, Ge-MAC, Ge-SAC의 4가지 감쇠보정방법을 사용하여 4가지 PET 영상을 얻었다. 정상인군에서는 대표적인 정상조직의, 환자군에서는 비정상적인 섭취를 보이는 병소의 SUV를 구하고, 이를 서로 비교 하였다. 결과: 정상인 군에서 CT-MAC 사용하여 감쇠보정한 PET 영상의 18개 정상조직의 SUV는 나머지 3가지 종류의 PET 영상에 비하여 모두 유의하게 높았다($3.1%{\sim}4.1%$; p<0.001). 환자군에서는 총 145개 병소의 국소 FDG 섭취증가 병변이 발견되었다. CT-MAC 사용한 PET 영상의 SUV 값은 나머지 3가지 PET 영상에 비하여 모두 유의하게 높았다($2.4%{\sim}5.1%$; p<0.001). Ge-MAC 사용한 PET 영상의 SUV 값은 CT-SAC와 Ge-SAC 사용한 PET 영상에 비하여 유의하게 높았다(p<0.001). 그러나, CT-SAC와 Ge-SAC PET 영상사이의 SUV에는 유의한 차이가 없었다. 폐병변에서는 감쇠보정방법사이에 섭취값이 유의한 차이가 없는 반면, 뼈병변에서는 이러한 차이가 가장 컸다($3.8%{\sim}9.6%$; p<0.01). 결론: $^{18}F-FDG$ PET 영상에서 섭취값은 CT-MAC로 감쇠보정을 했을 때에 가장 높다. CT 감쇠보정 및 MAC 사용, 2가지 모두가 이 차이에 기여했을 것이며, 이 중 MAC 사용이 더 크게 작용한 것으로 보인다. 감쇠보정방법이 다른 PET 영상들사이의 섭취값을 비교할 때는 이러한 차이를 고려해야 할 것이다.
PET와 PET/CT의 검사 영상품질관리를 위해서는 F-18 방사능측정기의 정도관리가 필요하다. Ge-68/Ga-68 Rod Sources을 선원을 이용하여 의료기관에서 사용하고 있는 5종류의 방사능측정기의 방사능 측정의 정확도와 정밀도를 확인하였다. CRC-15R, CRC-15 PET, CRC-712M, CRC-15 베타 및 CRC-25PET에 대한 측정값과 기준값 사이의 방사능 양에 따른 상관관계는 0.99999 (P <0.0001)로 매우 높은 선형성을 보였다. 정확도 테스트에서 CRC-15R, CRC-15 PET, CRC-712M, CRC-15 베타 및 CRC-25PET 모델은 각각 -3.232 %, -1.342 %, -2.815 %, -2.913 % 및 -3.089 %를 이었다. 국내와 국제기준인 정확도 ${\pm}10%$, 정밀도 ${\pm}5%$ 이내로 기준을 만족하였고 반감기가 짧은 F-18에 비하여 경제성 있고 비교적 긴 기간 동안 안정적으로 정도관리가 가능하다는 것을 확인하였다.
In order to investigate the effect of Ge addition to the Cu matrix on the microstructure and the critical current density, four kinds of internal tin processed Nb$_3$Sn strands with pure Cu and Cu 0.2, 0.4, 0.6 wt % Ge alloys were drawn to 0.8 mm diameter. The microstructure and critical current of internal tin processed Nb$_3$Sn wires that were heat treated at temperatures ranging from 68$0^{\circ}C$ to 74$0^{\circ}C$ for 240h were investigated. The Ge addition to the matrix did not make workability worse. A Ge rich layer in the Cu-Ge matrix suppressed the growth of the Nb$_3$Sn layer and promoted grain coarsening. The greater the Ge content in the matrix, the lower the net Jc result after Nb$_3$sn reaction heat treatment. There was no significant variation in Jc observed with heat treatment temperature ranging from 68$0^{\circ}C$ to 74$0^{\circ}C$. The values of AC loss of Ge added wires were decreased to 40 % compare with no addition wire. Low AC loss was due to segregation of Ge rich layer in the Cu-Ge matrix. If Ge added wire with thin Nb filaments were fabricated, slow diffusion rate of Sn would be overcome and decreased AC loss that is weak Point of internal tin method.
본 실험의 목적은 TSE-SPIR 지방소거기법과 GE-PROSET 지방소거기법을 비교하여 복부자기공명영상에서 최적의 T2 강조 지방소거기법을 평가하고자 한다. 자기공명영상 검사는 16채널 다중채널을 사용하여 1.5 T(Philips, Medical System, Achieva)기기로 수행하였다. 모든 영상은 TSE-SPIR과 GE-PROSET을 이용하여 축면상(axial plane)을 얻었다. TSE-SPIR과 GE-PROSET에 대한 후복막 지방의 평균 SNRs는 31.50, 4.15 이었으며, 장간막 지방에 대한 SNRs는 32.39, 7.03이었다. TSE-SPIR과 GE-PROSET에서 장과 후복막 지방, 장간막 지방의 CNRs는 152.69, 74.54 와 26.12, 68.78이었다. 장벽에 대한 묘출도는 TSE-SPIR(2.4), GE-PROSET(1.8)로 TSE-SPIR가 높게 나타났으며, 췌장벽(pancreas wall)에 대한 묘출도는 TSE-SPIR(1.90), GE-PROSET(2.80)로 GE-PROSET가 높게 나타났다. 결론적으로, T2 강조 지방소거 복부자기공명영상에서 GE-PROSET 지방소거기법 보다 TSE-SPIR 지방소거기법이 우위성 있은 평가를 얻었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.