• Title/Summary/Keyword: $^{244}Cm$

Search Result 155, Processing Time 0.025 seconds

The Hardness Water Production By RO/NF/ED Linking Process From Deep Seawater (RO/NF/ED 연계 공정에 의한 고경도 담수 제조)

  • Moon, Deok-Soo;Kim, Kwang Soo;Gi, Ho;Choi, Mi Yeon;Jung, Hyun Ji;Kim, Hyun Ju
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.16 no.4
    • /
    • pp.227-238
    • /
    • 2013
  • The purpose of this study is to develop a process technology to produce high hardness drinking water which meet drinking water standard, remaining useful minerals like magnesium and calcium in the seawater desalination process while removing the sulfate ions and chloride ions. Seawater have been separated the concentrated seawater and desalted seawater by passing on Reverse Osmosis membrane (RO). Using Nano-filtration membrane (NF), We were prepared primary mineral concentrated water that sodium chloride were not removed. By the operation of electro-dialysis (ED) having ion exchange membrane, we were prepared concentrated mineral water (Mineral enriched desalted water) which the sodium chloride is removed. We have produced the high hardness water to meet the drinking water quality standards by diluting the mineral enriched desalted water with deionized water by RO. Reverse osmosis membranes (RO) can separate dissolved material and freshwater from seawater (deep seawater). The desalination water throughout the second reverse osmosis membrane was completely removed dissolved substances, which dissolved components was removed more than 99.9%, its the hardness concentration was 1 mg/L or less and its chloride concentration was 2.3 mg/L. Since the nano-filtration membrane pore size is $10^{-9}$ m, 50% of magnesium ions and calcium ions can not pass through the nano-filtration membrane, while more than 95% of sodium ions and chloride ions can pass through NF membrane. Nano-filtration membrane could be separated salt components like sodium ion and chloride ions and hardness ingredients like magnesium ions and calcium ions, but their separation was not perfect. Electric dialysis membrane system can be separated single charged ions (like sodium and chloride ions) and double charged ions (like magnesium and calcium ions) depending on its electrical conductivity. Above electrical conductivity 20mS/cm, hardness components (like magnesium and calcium ions) did not removed, on the other hand salt ingredients like sodium and chloride ions was removed continuously. Thus, we were able to concentrate hardness components (like magnesium and calcium ions) using nano-filtration membrane, also could be separated salts ingredients from the hardness concentration water using electrical dialysis membrane system. Finally, we were able to produce a highly concentrated mineral water removed chloride ions, which hardness concentration was 12,600 mg/L and chloride concentration was 2,446 mg/L. By diluting 10 times these high mineral water with secondary RO (Reverse Osmosis) desalination water, we could produce high mineral water suitable for drinking water standards, which chloride concentration was 244 mg/L at the same time hardness concentration 1,260 mg/L. Using the linked process with reverse osmosis (RO)/nano filteration (NF)/electric dialysis (ED), it could be concentrated hardness components like magnesium ions and calcium ions while at the same time removing salt ingredients like chloride ions and sodium ion without heating seawater. Thus, using only membrane as RO, NF and ED without heating seawater, it was possible to produce drinking water containing high hardness suitable for drinking water standard while reducing the energy required to evaporation.

The Evaluation of Predose Counts in the GFR Test Using $^{99m}Tc$-DTPA ($^{99m}Tc$-DTPA를 이용한 사구체 여과율 측정에서 주사 전선량계수치의 평가)

  • Yeon, Joon-Ho;Lee, Hyuk;Chi, Yong-Ki;Kim, Soo-Yung;Lee, Kyoo-Bok;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.94-100
    • /
    • 2010
  • Purpose: We can evaluate function of kidney by Glomerular Filtration Rate (GFR) test using $^{99m}Tc$-DTPA which is simple. This test is influenced by several parameter such as net syringe count, kidney depth, corrected kidney count, acquisition time and characters of gamma camera. In this study, we evaluated predose count according to matrix size in the GFR test using $^{99m}Tc$-DTPA. Materials and Methods: Gamma camera of Infinia in GE was used, and LEGP collimator, three types of matrix size ($64{\times}64$, $128{\times}128$, $256{\times}256$) and 1.0 of zoom factor were applied. We increased radioactivity concentration from 222 (6), 296 (8), 370 (10), 444 (12) up to 518 MBq (14 mCi) respectively and acquired images according to matrix size at 30 cm distance from detector. Lastly, we evaluated these values and then substituted them for GFR formula. Results: In $64{\times}64$, $128{\times}128$ and $256{\times}256$ of matrix size, counts per second was 26.8, 34.5, 41.5, 49.1 and 55.3 kcps, 25.3, 33.4, 41.0, 48.4 and 54.3 kcps and 25.5, 33.7, 40.8, 48.1 and 54.7 kcps respectively. Total counts for 5 second were 134, 172, 208, 245 and 276 kcounts from $64{\times}64$, 127, 172, 205, 242, 271 kcounts from $128{\times}128$, and 137, 168, 204, 240 and 273 kcounts from $256{\times}256$, and total counts for 60 seconds were 1,503, 1,866, 2,093, 2,280, 2,321 kcounts, 1,511, 1,994, 2,453, 2,890 and 3,244 kcounts, and 1,524, 2,011, 2,439, 2,869 and 3,268 kcounts respectively. It is different from 0 to 30.02 % of percentage difference in $64{\times}64$ of matrix size. But in $128{\times}128$ and $256{\times}256$, it is showed 0.60 and 0.69 % of maximum value each. GFR of percentage difference in $64{\times}64$ represented 6.77% of 222 MBq (6 mCi), 42.89 % of 518 MBq (14 mCi) at 60 seconds respectively. However it is represented 0.60 and 0.63 % each in $128{\times}128$ and $256{\times}256$. Conclusion: There was no big difference in total counts of percentage difference and GFR values acquiring from $128{\times}128$ and $256{\times}256$ of matrix size. But in $64{\times}64$ of matrix size when the total count exceeded 1,500 kcounts, the overflow phenomenon was appeared differently according to predose radioactivity of concentration and acquisition time. Therefore, we must optimize matrix size and net syringe count considering the total count of predose to get accurate GFR results.

  • PDF

The Study for Radio Protection According to a Possible Danger of Exposure During dental X-ray Examination (치과 방사선 검사 시 노출 위험성에 따른 피폭선량 방어연구)

  • Lim, Cheong-Hwan;Kim, Seung-Chul;Jung, Hong-Ryang;Hong, Dong-Hee;You, In-Gyu;Jeong, Cheon-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.237-244
    • /
    • 2011
  • Generally, X-ray examinations for dentistry use low energy radiation. It explains that the radiations are mainly absorbed to a human body because of the weak permeability. We made up some counterplans for decrease in radiation exposure, when guardians and radiologists are overexposed owing to unavoidable circumstances. The equipments for the test are GX-770 and CRANEX TOME CEPH which are used for various exams. Besides we measured the radiations in the projection room and in the control room using model 2026c and 20X6-1800. According to the test, the measurement value in the control room was low dose below $20{\mu}R$, the maximum dose in the projection room was $702.8{\mu}R$ and the measurement value of back dose was higher than lateral one. As the result, if we use a shielding door, it's effective for radioprotection and when we didn't prepare protectors, we should secure appropriate distance and be situated at the side area($90{\sim}135^{\circ}$) on the basis of centeral radiation. That way will provide valuable aid for radioprotection.

Growth of artificial Pb$ZrO_3$/Pb$TiO_3$ superlattices by pulsed laser deposition and their electrical properties (펄스레이져 증착법을 이용한 Pb$ZrO_3$/Pb$TiO_3$ 산화물 인공격자의 성장 및 전기적 특성)

  • 최택집;이광열;이재찬
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.54-54
    • /
    • 2003
  • 최근 새로운 개념에 물성 구현을 위한 강유전체 산화물 인공격자의 연구가 활발히 진행되고 있다. 본 연구에서는 펄스레이져 증착법을 이용하여 산소분압 100 mTorr와 증착온도 50$0^{\circ}C$에서 LSCO/MgO 기판 위에 PbTiO$_3$(PTO) 와 PbZrO$_3$(PZO)을 주기적으로 적층하여 강유전체 산화물 인공격자를 형성하였다. 인공격자의 주기는 1~100 unitcell 까지 변화시켰다. 적층주기와 두께 변화에 따른 PZO/PTO 인공격자의 성장과 전기적 특성에 대하여 관찰하였다. X선 회절분석을 통하여 PZO/PTO 인공격자는 주기가 25 unit cell 이하의 적층구조에서 초격자의 형성으로 인한 위성피크가 관찰되었으며, 그 이하의 낮은 주기(1~10 unitcell)에서는 위성피크와 강한 (100)과 (200) 성장거동을 보였다. 높은 주기에서는 c축 성장된 PTO와 a축 성장된 PZO 각각의 성장거동을 보였다. 적층 주기가 감소함에 따라 a축 성장된 PTO와 c축 성장된 PZO가 초격자를 형성하였다. 적층주기가 감소함에 따라 유전상수와 잔류분극값이 향상되었다. 유전상수는 1 unitcell 주기에서 800정도의 값을 보였고, 잔류분극값은 2 unitcell 주기에서 2Pr=38.7 $\mu$C/$\textrm{cm}^2$ 정도의 가장 큰 값을 나타냈다. 적층주기가 2 unitcell에서 두께가 감소함에 따라 유전상수가 감소하였고, 20 nm 까지 분극반전에 의한 capacitance-voltage 특성곡선의 이력 현상(강유전성)을 관찰하였다. 이러한 산화물 인공초격자에서의 유전상수와 잔류분극값의 향상에 대하여 논의 할 것이며, 임계크기효과 관점에서 나노사이즈(50 nm~5 nm)에서 인공초격자의 전기적 분극의 안정성에 대하여 또한 논의 할 것이다.소수성 가스의 경우70% 이상 향상되었음을 알 수 있었으며, 본 연구를 통해 광분해를 이용한 스크러버가 기존설비의 장.단점을 충분히 보완 가능한 환경 설비임을 확인할 수 있었다. duty로 구동하였으며, duty비 증가에 따라 pulse의 on-time을 고정하고 frequency를 변화시켰다. dc까지 duty비가 증가됨에 따라 방출전류의 양이 선형적으로 증가하였다. 전압을 일정하게 고정시키고 각 duty비에서 시간에 따라 방출전류를 측정한 결과 duty비가 높을수록 방출전류가 시간에 따라 급격히 감소하였다. 각 duty비에서 방출전류의 양이 1/2로 감소하는 시점을 에미터의 수명으로 볼 때 duty비 대 에미터 수명관계를 구해 높은 duty비에서 전계방출을 시킴으로써 실제의 구동조건인 낮은 duty비에서의 수명을 단시간에 예측할 수 있었다. 단속적으로 일어난 것으로 생각된다.리 폐 관류는 정맥주입 방법에 비해 고농도의 cisplatin 투여로 인한 다른 장기에서의 농도 증가 없이 폐 조직에 약 50배 정도의 고농도 cisplatin을 투여할 수 있었으며, 또한 분리 폐 관류 시 cisplatin에 의한 직접적 폐 독성은 발견되지 않았다이 낮았으나 통계학적 의의는 없었다[10.0%(4/40) : 8.2%(20/244), p>0.05]. 결론: 비디오흉강경술에서 재발을 낮추기 위해 수술시 폐야 전체를 관찰하여 존재하는 폐기포를 놓치지 않는 것이 중요하며, 폐기포를 확인하지 못한 경우와 이차성 자연기흉에 대해서는 흉막유착술에 더 세심한 주의가 필요하다는 것을 확인하였다. 비디오흉강경수술은 통증이 적고, 입원기간이 짧고, 사회로의 복귀가 빠르며, 고위험군에 적용할 수 있고, 무엇보다도 미용상의 이점이 크다는 면에서 자연기흉에 대해 유용한 치료방법임에는 틀림이 없으나 개흉술에 비해 재발율이 높고 비용이 비싸다는 문제가 제기되고 있는 만큼 더 세심한 주의와 장기 추적관찰이 필요하리라 사료된

  • PDF

Investigating the Impact of Random and Systematic Errors on GPS Precise Point Positioning Ambiguity Resolution

  • Han, Joong-Hee;Liu, Zhizhao;Kwon, Jay Hyoun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.3
    • /
    • pp.233-244
    • /
    • 2014
  • Precise Point Positioning (PPP) is an increasingly recognized precisely the GPS/GNSS positioning technique. In order to improve the accuracy of PPP, the error sources in PPP measurements should be reduced as much as possible and the ambiguities should be correctly resolved. The correct ambiguity resolution requires a careful control of residual errors that are normally categorized into random and systematic errors. To understand effects from two categorized errors on the PPP ambiguity resolution, those two GPS datasets are simulated by generating in locations in South Korea (denoted as SUWN) and Hong Kong (PolyU). Both simulation cases are studied for each dataset; the first case is that all the satellites are affected by systematic and random errors, and the second case is that only a few satellites are affected. In the first case with random errors only, when the magnitude of random errors is increased, L1 ambiguities have a much higher chance to be incorrectly fixed. However, the size of ambiguity error is not exactly proportional to the magnitude of random error. Satellite geometry has more impacts on the L1 ambiguity resolution than the magnitude of random errors. In the first case when all the satellites have both random and systematic errors, the accuracy of fixed ambiguities is considerably affected by the systematic error. A pseudorange systematic error of 5 cm is the much more detrimental to ambiguity resolutions than carrier phase systematic error of 2 mm. In the $2^{nd}$ case when only a portion of satellites have systematic and random errors, the L1 ambiguity resolution in PPP can be still corrected. The number of allowable satellites varies from stations to stations, depending on the geometry of satellites. Through extensive simulation tests under different schemes, this paper sheds light on how the PPP ambiguity resolution (more precisely L1 ambiguity resolution) is affected by the characteristics of the residual errors in PPP observations. The numerical examples recall the PPP data analysts that how accurate the error correction models must achieve in order to get all the ambiguities resolved correctly.

Thermal and Water Transmission Properties of Vapor Permeable Water Repellent Fabrics and Thermal Insulation Batting Materials (투습발수직물과 보온단열소재의 열 및 수분전달 특성)

  • Cho Gil Soo;Choi Jong Myoung;Lee Jung Ju;Lee Sern Woo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.2
    • /
    • pp.237-244
    • /
    • 1992
  • The purpose of this study was to comparatively evaluate thermal and water transmission properties of several vapor permeable water repellent (VPWR) fabrics and synthetic battings that became available in recent years. Five VPWR fabrics evaluated were Hipora in three coating variants, $Gore-Tex^{\circledR}$ and $Aitace^{\circledR}$. Battings evaluated were $Viwarma^{\circledR}$, $Uniwarmr^{\circledR}$, $Thinsulate^{\circledR}$, and $Airseal^{\circledR}$ Thermal resistance and water vapor transmission were measured for each fabric and batting and in all combinations. Thermal resistance at zero and 37 cm/sec air velocity was determined by the Thermo Labo II technique for simultaneously measuring conduction and radiation heat transfer. Water vapor transmission over 24 hours was measured by a modified weight-gain method in a compact humid chamber at conditions simulating the clothing climate under heavy exercise ($40{\pm}1^{\circ}C$, $90{\pm}2\%$ R.H., and 0.5 m/sec air velocity). Fabric porosity was calculated from fiber density and fabric weight, thickness, and area. Thermal resistance results for the fabrics showed the effectiveness of coatings in inhibiting heat transfer. Measurements taken in wind were: $31.1\~37.6\%$ for $Hipora^{\circledR}$ variants; $31.0\%$ for $Gore-Tex^{\circledR}$; and $18.4\%$ for $Aitaca^{\circledR}$ Measurements without wind were higher but in the same order. Water vapor transmission results were in reverse order: $Aitac^{\circledR}$, $8.8 kg/m^{2};\;Gore-Tex^{\circledR}$, 6.4 kg/$m^{2}$; and $Hipora^{\circledR},\;4.4\~6.0\;kg/m^{2}$. In general thermal resistance increased with porosity. For battings, the thermal resistance with wind results were: $Viwarmu^{\circledR}$, $65.0\%;\; Thinsulate^{\circledR}$, $62.0\%$; $Uniwarm^{\circledR}$, $61.0\%$; and $Airseala^{\circledR},\;53.1\%$. Thermal resistance was proportional to thickness. Thermal resistance of fabric-batting combinations were $20\%$ higher than those of the battings only. Water vapor transmission for combinations was mainly affected by that for the VPWR fabric used.

  • PDF

Text integration processing based on connectives in Aphasics (실어증 환자의 접속사 정보처리에 관한 연구)

  • Kim, Soo-Jeong;Moon, Young-Sun;Kim, Mi-Ra;Kim, Yoo-Jeong;Nam, Ki-Chun
    • Annual Conference on Human and Language Technology
    • /
    • 1999.10e
    • /
    • pp.441-446
    • /
    • 1999
  • 본 연구는 접속사를 통한 텍스트 통합 과정이 논리적 추론 종류에 따라 다른 정보처리 과정 혹은 다른 종류의 단원적 구조(modular structure in language processing)에 의해 처리되는지를 조사하기 위해 실시되었다. 또한, 접속사를 통한 추론 과정이 실어증의 증상 종류에 따라 다른 종류의 언어정보처리 손상이 있는지를 평가하기 위해 실시되었다. 실험에 참가한 환자는 이해성 실어증환자(Wernicke aphasic), 전반성 실어증 환자(Global aphasic), 표현성 실어증 환자(Broca aphasic) 등이었다. en 종류의 과제를 이용하였다. 한 과제는 앞 뒤 문장을 논리적 관계성을 표현하는 접속사를 채워 넣는 과제였고 다른 과제는 접속사가 포함된 텍스트가 옳은지를 판단하는 정오 판단 과제였다. 실험재료 문장에 사용된 접속사는 추가적인 정보를 제공하는 '그리고'와 대등 관계를 나타내는 '그러나' 및 인과 관계를 표현하는 '그래서' 였다. 이 세 종류의 접속사는 각기 다른 논리적 관계성을 나타낸다. 실험 결과는 실어증 환자가 전반적으로 채워 넣기 과제에서 보다는 정오 판단 과제에서 더 많은 실수를 보였으며, 표현성 실어증 환자보다는 이해성 실어증 환자가 더 많은 오류를 보였다. 또한, 세 종류의 접속사 중에 '그리고'가 표함된 텍스트에서 더 많은 실수를 보였다. 이 연구에서 나타난 흥미 있는 결과는 표현성 실어증 환자는 '그러나' 접속사가 포함된 텍스트에서의 수행이 '그래서'가 포함된 경우에서보다 좋은 반면에 전반성 실어증 환자는 '그래서'를 포함하는 텍스트에서의 수행이 '그러나'를 포함하는 텍스트에서의 수행이 더 우수해서 이중해리(double dissociation)가 나타난다는 사실이다. 이 결과는 선후 문장이 어떤 종류의 논리적 관계성을 지니는가에 따라 다른 종류의 정보처리가 진행된다는 것을 암시하는 결과이다.>$\textrm{cm}^2$.。C로 비교적 양호한 초전박막의 전기적 특성을 나타내었다.(Mg+Fe)비를 갖고 전자에 비해 Al이 풍부한 환경에서 생성되었으며, 따라서 활석과 연관되지 않은 녹니석은 생성시 광체와 인접한 화강아질 편마암에 의해 주로영향을 받았을 것으로 생각된다. 녹니석의 이러한 2가지 화학조성상의 경향은 녹니석과 공존하는 운모류나 각섬석류들의 화학분석결과와도 잘 일치한다. 이러한 결과는 이 지역의 활석 광상이 초염기성암 기원의 사문암이 열수변질작용을 받아 생성되었음을 명확하게 지시하며, 따라서 활석 광석내에 존재하는 녹니석은 활석의 근원 광물로서 녹니석편암 및 녹니석 편마암 매의 녹니석이 활석화되고 남은 잔존광물이 아니라, 주변암에 의해 성분상의 영향을 받은 열수와 사문암과의 변질교대작용에 의한 활석화과정 중에 주로 생성된 것으로 추정된다. 이러한 결과는 연구지역의 활석광상이 초염기성암의 사문암화 작용과 활석화 작용의 두 가지 변질작용에 의해 형성되어졌음을 알려준다.농도 증가 없이 폐 조직에 약 50배 정도의 고농도 cisplatin을 투여할 수 있었으며, 또한 분리 폐 관류 시 cisplatin에 의한 직접적 폐 독성은 발견되지 않았다이 낮았으나 통계학적 의의는 없었다[10.0%(4/40) : 8.2%(20/244), p>0.05]. 결론: 비디오흉강경술에서 재발을 낮추기 위해 수술시 폐야 전체를 관찰하여 존재하는 폐기포를 놓치지 않는 것이 중요하며, 폐기포를 확인하지 못한 경우와 이차성 자연기흉에 대해서는 흉막유착술에 더 세심한 주의가 필요하다는 것을 확인하였다. 비디오흉강경수술은 통증이 적고, 입원기간이 짧고, 사회로의 복귀가 빠르며, 고위험군에 적용할 수 있고, 무엇보다도 미용상의 이점이 크다는 면에서 자연기흉에 대해 유용한 치료방법임에는 틀림이 없으나 개흉술에 비해 재발율이 높고 비용이 비싸다는 문제가 제기되고 있는 만큼

  • PDF

Effects of Aquarobics Exercise on Body Composition, Fitness andHealth Related Quality of Life(SF-36) in Elderly Women (아쿠아로빅 운동이 노인 여성의 신체구성, 체력 및건강관련 삶의 질(SF-36)에 미치는 영향)

  • So, Wi-Young;Hong, Jee-Young;Jun, Eun-Jin;Choi, Dai-Hyuk;Kim, Ki-Hong
    • 한국노년학
    • /
    • v.30 no.3
    • /
    • pp.683-694
    • /
    • 2010
  • This study was to investigate the effects of aquarobics exercise on body composition, fitness and health related quality of life (sf-36) in elderly women and to provide basic data to exercise prescription. The subjects were the 60~70 years old seniors who participated in exercise program at health promotion center and had been divided into exercise(N=25) and control(N=30) group, respectively. Aquarobics exercise was performed twice per week for 8 weeks at 40~70% heart rate reserve(exercise intensity) and body composition, fitness and SF-36 were measured before and after exercise. In body composition, there were significance in weight(p=0.044), body mass index(p=0.038), and %fat(p=0.005) between groups before and after. In fitness, there were no significance in fitness such as chair stand, and chair sit and reach, but there were significance in 2-minute step(p<0.001), arm curl(p=0.005), back scratch(p=0.023), and 8-ft up and go(p<0.001) between groups. In SF-36, there were no significance in physical functioning, role limitation-physical, role limitation-emotional, social functioning, mental health, and vitality, but there were significance in bodily pain(p=0.039), and general health(p=0.024) between groups. It was found that aquarobics exercise was one of the good exercise types for the elderly to improve body composition and fitness. Also, there was positive effect on health-related quality of life partially.

Effects of the Different Anesthetic Doses of MS-222 and Lidocaine-HCl on the Blood Physiological Responses in Black Rockfish, Sebastes schlegeli (MS-222와 lidocaine-HCl의 농도별 마취에 대한 조피볼락(Sebastes schlegeli)의 혈액생리학적 반응)

  • Kim Jae Ho;Hur Jun Wook;Park In-Seok;Kho Kang Hee;Chang Young Jin
    • Journal of Aquaculture
    • /
    • v.18 no.4
    • /
    • pp.236-244
    • /
    • 2005
  • Experiments were performed to investigate the effects of the different anesthetic MS-222 and lidocaine-HCl doses on the blood physiological responses, on the time required for anesthesia and recovery, and on the survival rates of black rockfish (Sebastes schlegeli). Plasma cortisol was its highest levels (96.1$\pm$12.1 ng/ml) at 6 hours after the administration of 300 ppm of MS-222, and in all groups, plasma cortisol levels were higher than the initial levels during the anesthetic experiment. Fish receiving lidocaine-HCl also exhibited higher than initial plasma cortisol levels at almost experimental intervals. The middle size fish exhibited the highest glucose level (143.3$\pm$14.5 mg/dl) at 50 ppm of anesthesia after 1 hour, and every level was significantly higher than the initial level for at least 12 hours. Glucose levels in fish to which lidocaine-HCl was administered were comparable to the levels seen in conjunction with MS-222 treatment. In fish anesthetized with MS-222, K+ levels in the small size fish were significantly elevated after 1 hour, while Na+ levels did not change in any of the groups throughout the experiment. Anesthetic time was significantly attenuated with increases in the concentrations of MS-222 and lidocaine-HCl. We also noted a correlation between anesthetic time and fish size, in that larger fish took a longer time, followed by the middle size and then the small size fish. The all fish size groups showed above $95\%$ survival rates at every experimental concentration in MS-222 and 300-400 ppm in lidocaine-HCl. The results may indicate that 100-200 ppm MS-222 and 400 ppm lidocaine-HCl are the most effective doses as sedatives for the black rockfish and these doses could be used as the suitable anesthetics doses.

Prevalence of Enteyobius vermiculuris infection and preventive effects of masts treatment among children in rural and urban areas, and children in orphanages (농촌, 도시 및 집단생활 아동의 요충 감염과 집단 구충에 의한 예방 효과)

  • Kim, Jong-Su;Lee, Hae-Yong;An, Yeong-Gyeom
    • Parasites, Hosts and Diseases
    • /
    • v.29 no.3
    • /
    • pp.235-244
    • /
    • 1991
  • An epidemiological study and mass treatments of Enterobius vermicularis infection among children near Wonju area of Kangwon province were carried out. The children were divided into 4 groups according to their residing localities; children in the mountainous area, rural area, urban area and in orphanage. They were examined by adhesive cellotape anal swab technique, and egg positive rates were obtained. The rates of egg reduction and re-infection rates after repeated mass treatments were also observed. The results obtained were as follows: 1. The overall egg Positive rate of E. vermicularis in the first screening was 19.9% (251 out of 1, 262 examinees; 19.7% in males and 20.1% in females). The positive rates were 13.0% in the mountainous area, 11 9% in the rural area, 15.1% in the urban (medium-sized) area and 61.9% in orphanages. 2. The highest positive rates were observed in the kindergarten children, and 1st and 2nd grade children of primary schools (26.2~32.2%), and the lowest rate (13.6%) in 6-year grade children of primary schools. 3. Cumulative detection rates from 3 repeated anal swabs at 4~5 days interval were higher (70.8%) than those from single anal swabs (50.0~59.2%). 4. Out of the examinees who showed the highest cumulative positive rate (70.8%), about 39.2% were consecutively positive in 3 anal swabs. Among different groups of children, the higher the total egg detection rates (87.5%), the higher the consecutive positive rates (71.9%) . 5. A total of 2, 609 (male : female=1 : 12.4) worms were collected from 17 egg-positive cases treated with anthelinintics. The mean number of worms per child was 153 (range: 4-824) . 6. The egg-positive cases in several studied groups (180 children) were treated with anthelmintics 6 times at 3-week intervals. In this case, the overall positive rate was decreased from 54.8% to 2.2% at 15 weeks after the treatments, but no complete negative conversion was experienced. However, in a group of children (154 children) including egg Positive and negative cases who were both treated with anthelmintics at 3-week interval, a complete egg-negative conversion was observed in the 9th week after treatments. 7. The egg-detection rate in the brothers or sisters of egg Positive children was 70.0% (28 out of 40 examined), and the egg-positive rate according to the family unit was 69.7%. In summarizing the above results, it is concluded that Enterobius vermicularis infection is still highly prevalent among children in Korea, and that repeated mass treatments of more than 3 times will be effective for control of this infection.

  • PDF