• Title/Summary/Keyword: $^{18}FDG$

Search Result 575, Processing Time 0.021 seconds

Study of SUVm Cut-off Value for the Distinction of Pancreatic Cancer In PET/CT Exam (PET/CT 검사에서 췌장암 판별을 위한 SUVm 경계값 연구)

  • Chang, Boseok;Kim, Jae Ho;Liu, Guoxu;Jang, Eun Sung
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.10
    • /
    • pp.567-575
    • /
    • 2017
  • In this study, when diagnosis pancreatic cancer by dual time point PET/CT, we propose SUVm 2.52 as the threshold value for performing the dual time point PET/CT exam. The hypothesis of normal distribution was adopted through data conversion of 60 pancreatic diseases. The proposed SUVm2.52 boundary value showed a significance level that could be applied to both 120 and 180 minutes of delay time scan for pancreatic cancer determination (p<0.05). C-value variation shows that delay time 2 hour test is more useful than delay time 3 hour test. When the SUVm 2.52 is set to the boundary value and the double-time point PET/CT exam is performed, the probability of distinguishing cancer from inflammation in the delayed image is 95%. When the delayed test is performed with the proposed boundary value SUVm 2.52, Compared with general PET / CT scans, it is thought that it may be helpful to distinguish pancreatic cancer.

Differences in the Prognostic Significance of the SUVmax between Patients with Resected Pulmonary Adenocarcinoma and Squamous Cell Carcinoma

  • Motono, Nozomu;Ueno, Masakatsu;Tanaka, Makoto;Machida, Yuichiro;Usuda, Katsuo;Sakuma, Tsutomu;Sagawa, Motoyasu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.23
    • /
    • pp.10171-10174
    • /
    • 2015
  • Background: The purpose of this study was to determine the prognostic significance of the maximum standardized uptake value (SUVmax) on F-18-fluorodeoxyglucose (FDG)-positron emission tomography (PET) in patients undergoing surgical treatment for non-small cell lung cancer. Materials and Methods: Seventy-eight consecutive patients (58 with adenocarcinomas, 20 with squamous cell carcinomas) treated with potentially curative surgery were retrospectively reviewed. Results: The SUVmax was significantly higher in the patients with recurrent than with non-recurrent adenocarcinoma (p<0.01). However, among the patients with squamous cell carcinoma, there were no differences with or without recurrence (p=0.69). Multivariate analysis indicated that the SUVmax of adenocarcinoma lesions was a significant predictor of disease-free survival (p=0.04). In addition, an SUVmax of 6.19, the cut-off point based on ROC curve analysis of the patients with pathological IB or more advanced stage adenocarcinomas, was found to be a significant predictor of disease-free survival (p<0.01). Conclusions: SUVmax is a useful predictor of disease-free survival in patients with resected adenocarcinoma, but not squamous cell carcinoma. Patients with adenocarcinoma exhibiting an SUVmax above 6.19 are candidates for more intensive adjuvant therapy.

Virtual lymph node analysis to evaluate axillary lymph node coverage provided by tangential breast irradiation

  • Park, Shin-Hyung;Kim, Jae-Chul;Lee, Jeong Eun;Park, In-Kyu
    • Radiation Oncology Journal
    • /
    • v.33 no.1
    • /
    • pp.50-56
    • /
    • 2015
  • Purpose: To investigate the coverage of axillary lymph node with tangential breast irradiation fields by using virtual lymph node (LN) analysis. Materials and Methods: Forty-eight women who were treated with whole breast irradiation after breast-conserving surgery were analyzed. The axillary and breast volumes were delineated according to the Radiation Therapy Oncology Group (RTOG) contouring atlas. To generate virtual LN contours, preoperative fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) scans with identifiable LN were fused with the CT scans, and the virtual LN contour were delineated on the CT. Results: The median level I and II axillary volume coverage percentages at the $V_{D95%}$ line were 33.5% (range, 5.3% to 90.4%) and 0.6% (range, 0.0% to 14.6%), respectively. Thirty-one LNs in 18 patients were delineated (26 in level I and 5 in level II). In the level I axilla, 84.6% of virtual LNs were encompassed by the 95% isodose line. In the level II axilla, by contrast, none of the virtual LNs were encompassed by the 95% isodose volumes. There was a substantial discrepancy between the RTOG contouring atlas-based axillary volume analysis and the virtual LN analysis, especially for the level I axillary coverage. The axillary volume coverage was associated with the body mass index (BMI) and breast volume. Conclusion: The tangential breast irradiation did not deliver adequate therapeutic doses to the axillary region, particularly those in the level II axilla. Patients with small breast volumes or lower BMI showed reduced axillary coverage from the tangential breast fields. For axillary LN irradiation, individualized anatomy-based radiation fields for patients would be necessary.

A Case of Pancreatic Acinar Cell Carcinoma (췌장 선방세포암 1예)

  • Lee, Hwa-Jung;Ji, Jun-Ho;Park, Seung-Chan;Park, Jung-Chul;Choi, Eun-Jung;Seo, Hye-Jin;Lee, Won-Sik;Lee, Jung-Lim;Bae, Byung-Jo;Shon, Kyung-Rak;Lee, Kyung-Hee
    • Journal of Yeungnam Medical Science
    • /
    • v.25 no.2
    • /
    • pp.128-133
    • /
    • 2008
  • Acinar cell carcinoma is a rare tumor that represents 1~2% of all pancreatic cancers. Clinical and radiologic findings are inconclusive in this disease. Acinar cell carcinoma is characterized by rapid progression and early metastasis, which lead to its poor prognosis. A 41-year-old man was admitted to our hospital for abdominal pain. Abdominal computed tomography (CT) and positron emission tomography-computed tomography (PET-CT) showed a splenic mass, which was being invaded by a pancreatic tail mass and which had increased $^{18}F$-fluorodeoxyglucose (FDG) uptake. Primary radical distal pancreatectomy and splenectomy were performed. Pathologic findings revealed an acinar cell carcinoma of the pancreas. The patient underwent a total gastrectomy three months later because of gastric recurrence. Four months later, multiple hepatic metastases were discovered, and the patient underwent a left hepatectomy. During treatment with capecitabine, there was no evidence of tumor progression for 14 months. We report a case of metastatic pancreatic acinar cell carcinoma, which did not progress for an extended period while the patient was being treated with capecitabine.

  • PDF

The Lowest Dose for CT Attenuation Correction in PET/CT

  • Kang, Byung-Sam;Son, Jin-Hyun;Park, Hoon-Hee;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.111-115
    • /
    • 2011
  • PET/CT(Positron Emission Tomography/Computed Tomography) is an examination combining morphological and functional information in one examination. The purpose of this study is to see the lowest CT dose for attenuation correction in the PET/CT maintaining good image quality when considering CT scan dose to the patients. We injected $^{18}F$-FDG and water into the cylinder shaped phantom, and obtained emission images for 3 mins and transmission images(140 kVp, 8 sec, 10~200 mA for transmission images), and reconstructed the images to PET/CT images with Iterative method. Data(Maximum, Minimum, Average, Standard Deviation) were obtained by drawing a circular ROI(Region Of Interest) on each sphere in each image set with Image J program. And then described SD according to the CT and PEC/CT images as graphes. Through the graphes, we got the relationships of mA and quality of images. SDs according to CT graph were 16.25 at 10 mA, 7.26 at 50 mA, 5.5 at 100 mA, 4.29 at 150 mA, and 3.83 at 200 mA, i.e. the higer mA, the better image quality was presented. SDs according to PET/CT graph were 1823.2 at 10 mA, 1825.1 at 50 mA, 1828.4 at 100 mA, 1813.8 at 150 mA, and 1811.3 at 200 mA. Calculated SDs at PET/CT images were maintained. This means images quality is maintained having nothing to do with mA of high and low.

  • PDF

Influence on PET Exam Caused by Density Differences of Barium-sulfate Contrast Media (Barium 조영제의 농도 차이가 PET 검사에 미치는 영향)

  • Choi, Woo-Joon;Shin, Sang-Ki;Nam, Ki-Pyo;Park, Soon-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.27-32
    • /
    • 2008
  • Purpose: The evaluation of SUV (Standardized Uptake Values) for quantitative analysis in PET exam is the most significant. In PET exam, we make attenuation correction images by using $^{68}Ge$, $^{137}Cs$ or CT data. At this time, a distorted attenuation map affects quantitative analysis. After the exam using barium-sulfate and high density of barium contrast make attenuation map distorted. And then it brings bed influences on SUV. The aim of this study is to verify the relationship between high density barium-sulfate and SUV in PET exam. Materials and Methods By using $^{18}F$-FDG, we made barium-sulfate powder, density of 0, 1.5, 3, 5, 10 and 15% respectively and acquired PET and PET/CT images per each density. And we examined SUV variations from PET and PET/CT images according to differences of barium's density. Moreover, we finally calculated SUV causing variations in HU (Hounsfield Units) values to justify whether the differences of barium density bring any changes in PET/CT exam. Results: From PET images acquired from transmission scan with $^{68}Ge$, we got SUV figures from 6.46 to 6.8 in barium density between 0 to 15 percent. On the other hand, In PET images acquired from Tx scan that using CT, SUV was 6.77 to 23.73, derived from the same barium density. And CT HU values range from 29 to 2004. Conclusion: PET images from Tx data using $^{68}Ge$ weren't affected by barium density and had no differences in SUV. But in the PET/CT images using CT Tx data, there's considerable variations in HU and SUV values according to a difference of barium density in HU values. To perform a precise examination, barium sulfate should be removed from a human body before performing a PET exam.

  • PDF

The Importance of Filter Integrity Test to Ensure Sterility of Radiophamaceuticals for Using PET Image

  • Cho, Yong-Hyun;Park, Jun-Hyung;Hwang, Ki-Young;Kim, Hyung-Woo;Lee, Hong-Jae;Kim, Hyun-Ju
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.74-77
    • /
    • 2008
  • The radiopharmaceuticals are routinely injected to blood vessel for acquiring PET image. For this reason, It is imperative that they undergo strict quality control measures. Especially, Sterility test is more important than any other quality control procedures. According to the FDA guideline, It requires filter integrity test used in the processing of sterile solutions. Among several methods, we can decide to use bubble point test. We usually use vented GS-filters (Millipore co., USA) which are sterilizinggrade (0.22 um pore size) and are placed upper site on product vial. After the synthesis of $^{18}F$-FDG, solutions wet the membrane in filter and then go into the product vial. By all synthesis steps have finished, we can observe the presence of the bubbles in the product vial. Since we have started this study, we have never found any bubbles in the product vial. Because the maximum pressure intensity of the filter which has set by manufacturer is up to 5 bars, but helium gas pressure is up to 1 bar in our module system. So, we can make 5 bars pressure using helium gas bombe and increase pressure up to 5 bars step by step. However, it does not happen to anything in vial.

  • PDF

Observational approach on regional lymph node in cutaneous melanomas of extremities

  • Jang, Bum-Sup;Eom, Keun-Yong;Cho, Hwan Seong;Song, Changhoon;Kim, In Ah;Kim, Jae-Sung
    • Radiation Oncology Journal
    • /
    • v.37 no.1
    • /
    • pp.51-59
    • /
    • 2019
  • Purpose: We evaluated failure pattern and treatment outcomes of observational approach on regional lymph node (LN) in cutaneous melanoma of extremities and sought to find clinico-pathologic factors related to LN metastases. Material and Methods: We retrospectively reviewed 73 patients with cutaneous melanoma of extremities between 2005 and 2016. If preoperative 18-F-fluorodeoxyglucose (FDG)-positron emission tomography/computed tomography (PET/CT) findings were non-specific for regional LNs, surgical resection of primary tumors with adequate margins was performed without sentinel lymph node biopsy (SLNB) and/or complete lymph node dissection (CLND), irrespective of tumor thickness or size. In patients with suspicious or positive findings on PET/CT or CT, SLNB followed by CLND or CLND was performed at the discretion of the surgeon. We defined LN dissection (LND) as SLNB and/or CLND. Results: With a median follow-up of 38 months (range, 6 to 138 months), the dominant pattern of failure was regional failure (17 of total 23 events, 74%) in the observation group (n = 56). Pathologic LN metastases were significant factor for poor regional failure-free survival (hazard ration [HR] = 3.21; 95% confidence interval [CI], 1.03-10.33; p = 0.044) and overall survival (HR = 3.62; 95% CI, 1.02-12.94; p = 0.047) in multivariate analysis. In subgroup analysis for cN0 patients according to the preoperative PET/CT findings, LND group showed the better trend of LRFFS (log rank test, p = 0.192) and RFFS (p = 0.310), although which is not statistically significant. Conclusion: Observational approach on regional LNs on the basis of the PET/CT in patients with cutaneous melanoma of extremities showed the dominant regional failure pattern compared to upfront LND approach. To reveal regional lymph node status, SLND for cN0 patients may of importance in managing cutaneous melanoma patients.

Risk Assessment of 30 MeV Cyclotron Facilities (30 MeV 사이클로트론 시설 위험성 평가)

  • Jeong, Gyo-Seong;Kim, Chong-Yeal;Lee, Jin-Woo
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.39-45
    • /
    • 2017
  • A cyclotron is a kind of particle accelerator that produces a beam of charged particles for the production of medical, industrial, and research radioisotopes. More than 30 cyclotrons are operated in Korea to produce $^{18}F$, an FDG synthesis at hospitals. A 30-MeV cyclotron was installed at ARTI (Advanced Radiation Technology Institute, KAERI) mainly for research regarding isotope production. In this study, we analyze and estimate the items of risk such as the problems in the main components of the cyclotron, the loss of radioactive materials, the leakage of coolant, and the malfunction of utilities, fires and earthquakes. To estimate the occurrence frequency in an accident risk assessment, five levels, i.e., Almost certain, Likely, Possible, Unlikely, and Rare, are applied. The accident consequence level is classified under four grades based on the annual permissible dose for radiation workers and the public in the nuclear safety law. The analysis of the accident effect is focused on the radioactive contamination caused by radioisotope leakage and radioactive material leakage of a ventilation filter due to a fire. To analyze the risks, Occupation Safety and Health Acts is applied. In addition, action plans against an accident were prepared after a deep discussion among relevant researchers. In this acts, we will search for hazard and introduce the risk assessment for the research 30-MeV cyclotron facilities of ARTI.

The Evaluation of the Difference of the SUV Caused by DFOV Change in PET/CT (PET/CT 검사에서 확대된 표시시야가 표준섭취계수에 미치는 영향 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.13-20
    • /
    • 2011
  • Purpose: The limited FOV(Field of View) of CT (Computed Tomography) can cause truncation artifact at external DFOV (Display Field of View) in PET/CT image. In our study, we measured the difference of SUV and compared the influence affecting to the image reconstructed with the extended DFOV. Materials and Methods: NEMA 1994 PET Phantom was filled with $^{18}F$(FDG) of 5.3 kBq/mL and placed at the center of FOV. Phantom images were acquired through emission scan. Shift the phantom's location to the external edge of DFOV and images were acquired with same method. All of acquired data through each experiment were reconstructed with same method, DFOV was applied 50 cm and 70 cm respectively. Then ROI was set up on the emission image, performed the comparative analysis SUV. In the clinical test, patient group shown truncation artifact was selected. ROI was set up at the liver of patient's image and performed the comparative analysis SUV according to the change of DFOV. Results: The pixel size was increase from 3.91 mm to 5.47 mm according to the DFOV increment in the centered location phantom study. When extended DFOV was applied, $_{max}SUV$ of ROI was decreased from 1.49 to 1.35. In case of shifted the center of phantom location study, $_{max}SUV$ was decreased from 1.30 to 1.20. The $_{max}SUV$ was 1.51 at the truncated region in the extended DFOV. The difference of the $_{max}SUV$ was 25.9% higher at the outside of the truncated region than inside. When the extended DFOV was applied, $_{max}SUV$ was decreased from 3.38 to 3.13. Conclusion: When the extended DFOV was applied, $_{max}SUV$ decreasing phenomenon can cause pixel to pixel noise by increasing of pixel size. In this reason, $_{max}SUV$ was underestimated. Therefore, We should consider the underestimation of quantitative result in the whole image plane in case of patient study applied extended DFOV protocol. Consequently, the result of the quantitative analysis may show more higher than inside at the truncated region.

  • PDF