• Title/Summary/Keyword: $^{133}Cs$

Search Result 90, Processing Time 0.031 seconds

Study on (n,p) reactions of 58Ni, 99Tc, 99Ru, 131Xe, 133Cs and 186Os radioisotopes used in medicine

  • Hallo M. Abdullah;Ali H. Ahmed
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.304-309
    • /
    • 2023
  • In the last decade, nuclear medicine appears to be a good choice of medicine. 58Co, 99Mo, 99Tc, 99Re, 133Xe and 186Re are very important radionuclides for nuclear medicine. In this study, the excitation functions of 58Ni (n, p) 58Co, 99Tc (n, p) 99Mo, 99Ru (n, p) 99Tc, 131Xe (n, p) 131I, 133Cs (n, p) 133Xe and 186Os (n, p) 186Re nuclear reactions were calculated at neutron energies between 1 and 20 MeV using TALYS 1.95 and EMPIRE 3.2 nuclear codes. Furthermore, the cross sections were calculated with the empirical formula derived in our past study at 14-15 MeV. The obtained results were compared with the measured values in EXFOR library, and with the evaluated data of (JENDL-4.0/HE, JEFF-3.3, TENDL-2019, ENDF/B-VIII.0, IRDFF-II, JENDL/ImPACT-18). The results are in good agreement with those of the evaluated data libraries and experimental results and indicates that these radioisotopes can be produced by smaller cyclotrons.

Removal of Cs and Sr in Water Using Chemical and Natural Coagulants (화학 및 천연 응집제를 이용한 수중 Cs, Sr 제거)

  • Kim, Seongbeom;Kim, Youngsug;Kang, Sungwon;Oh, Daemin;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.12
    • /
    • pp.662-666
    • /
    • 2016
  • This study investigated removal of radionuclides (Cs, Sr) in surface water by coagulation and precipitation. Jar tests were conducted with various chemical and natural coagulants to remove the stabilized radionuclides ($^{133}Cs$, $^{88}Sr$). Chemical coagulants included aluminum sulfate, poly aluminum chloride, and poly aluminum hydroxide chloride silicate (PACS); natural coagulants (minerals) included illite and zeolite. Chemical coagulant alone could achieve removals of Cs and Sr less than 10%; The removals increased up to 23.1% for Cs and 17.8% for Sr with addition of poly-dimethyldiallylammonium chloride (polyDADMAC) along with the chemical coagulants. Compared with chemical coagulants, natural coagulants (minerals) could achieve higher removals of Cs and Sr. Addition of zeolite along with PACS and polyDADMAC increased the removal rates up to 36.9% for Cs and 17.1% for Sr.

Radiation measurement and imaging using 3D position sensitive pixelated CZT detector

  • Kim, Younghak;Lee, Taewoong;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • v.51 no.5
    • /
    • pp.1417-1427
    • /
    • 2019
  • In this study, we evaluated the performance of a commercial pixelated cadmium zinc telluride (CZT) detector for spectroscopy and identified its feasibility as a Compton camera for radiation monitoring in a nuclear power plant. The detection system consisted of a $20mm{\times}20mm{\times}5mm$ CZT crystal with $8{\times}8$ pixelated anodes and a common cathode, in addition to an application specific integrated circuit. The performance of the various radioisotopes $^{57}Co$, $^{133}Ba$, $^{22}Na$, and $^{137}Cs$ was evaluated. In general, the amplitude of the induced signal in a CZT crystal depends on the interaction position and material non-uniformity. To minimize this dependency, a drift time correction was applied. The depth of each interaction was calculated by the drift time and the positional dependency of the signal amplitude was corrected based on the depth information. After the correction, the Compton regions of each spectrum were reduced, and energy resolutions of 122 keV, 356 keV, 511 keV, and 662 keV peaks were improved from 13.59%, 9.56%, 6.08%, and 5%-4.61%, 2.94%, 2.08%, and 2.2%, respectively. For the Compton imaging, simulations and experiments using one $^{137}Cs$ source with various angular positions and two $^{137}Cs$ sources were performed. Individual and multiple sources of $^{133}Ba$, $^{22}Na$, and $^{137}Cs$ were also measured. The images were successfully reconstructed by weighted list-mode maximum likelihood expectation maximization method. The angular resolutions and intrinsic efficiency of the $^{137}Cs$ experiments were approximately $7^{\circ}-9^{\circ}$ and $5{\times}10^{-4}-7{\times}10^{-4}$, respectively. The distortions of the source distribution were proportional to the offset angle.

NEUTRON CROSS SECTION DATA LIBRARY FOR PD-105, AG-109, XE-131 AND CS-133

  • LEE Y. D.;CHANG J. H.
    • Nuclear Engineering and Technology
    • /
    • v.37 no.1
    • /
    • pp.101-108
    • /
    • 2005
  • The neutron induced nuclear cross-section data for Pd-105, Ag-109, Xe-131, and Cs-133 were calculated and evaluated from an unresolved energy to 20 MeV. The energy dependent optical model potential parameters were extracted based on recent experimental data and applied up to 20 MeV. A spherical optical model and a statistical model for the equilibrium energy, and a multistep direct and a multistep compound model for the pre-equilibrium energy were used in the calculation. The direct capture model was recently introduced for fast neutron capture. The theoretically calculated cross-sections were compared with the experimental data and the evaluated files. The total and capture cross-sections calculated using the model were in good agreement with the reference experimental data. The evaluated cross-section results were compiled in ENDF-6 format and merged with the resonance component, already adopted in the ENDF/B-VI release 8. New data library files covering from thermal to 20 MeV were created. They are at the preliminary stage of an ENDF/B- VII release.

Ferroelectric-Paraelectric Phase Transition of CsH2PO4 studied by Static NMR and MAS NMR

  • Lim, Ae Ran;Lee, Kwang-Sei
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.19 no.1
    • /
    • pp.29-35
    • /
    • 2015
  • The microscopic dynamics of $CsH_2PO_4$, with two distinct hydrogen bond lengths, are studied by static nuclear magnetic resonance (NMR) and magic angle spinning (MAS) NMR. The proton dynamics of the two crystallographically inequivalent hydrogen sites were discussed in terms of the $^1H$ NMR and $^1H$ MAS NMR spectra. Although the hydrogen bonds have two inequivalent sites, H(1) and H(2), distinct proton dynamics for the two sites were not found. Further, the $^{133}Cs$ spectrum is more or less continuous near $T_{C1}$ (=153 K). Finally, the phase transition mechanism of $T_{C1}$ in $CsH_2PO_4$ is related to the ordering of protons.

Compensation System for Wireless Location based on Pyroelectric sensor (초전센서를 이용한 무선 위치 인식 보정 시스템)

  • Sung, Joo-Hyun;Cho, Hyun-Jong;Kim, Yoon-Sik;Seo, Dong-Hoan
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2012.06a
    • /
    • pp.133-133
    • /
    • 2012
  • 본 연구에서는 현재의 실내 위치인식시스템에 있어서 오차 발생 문제점을 초전센서를 이용하여 보완하였다. 기존의 CSS기술은 SDS-TWR(Symmetric Double-Sided Two-Way Ranging) 기반의 위치인식시스템을 구현하는 기술로 사용되고 있으나 전파의 반사 및 간섭에 의해 레인징의 오차가 크게 발생하고 수신 감도가 현저하게 떨어지는 현상이 발생한다. 따라서 본 논문에서는 환경적인 제약을 받는 공간에서 CSS을 이용한 SDS-TWR과 초전센서를 사용하여 수신불량과 오차를 줄여 사용자의 위치인식을 가능하도록 하였다.

  • PDF

이성체쌍의 열중성자포획단면적비 측정

  • Park, Hy-Eil;Kim, Heon-Jun;Lee, Chul
    • Nuclear Engineering and Technology
    • /
    • v.4 no.4
    • /
    • pp.340-344
    • /
    • 1972
  • Isomeric ratios were measured for the capture of thermal neutron by $^{79}$ Br, $^{80}$ Se, $^{103}$ Rh, $^{115}$ In and $^{133}$ Cs as well as those of epi-cadmium neutron by $^{79}$ Br, $^{80}$ Se and $^{l33}$Cs. The measurements were performed by analysing decay curves obtained by ${\gamma}$-ray spectrometry after irradiation. The counting efficiency curve was determined by using the calibrated standard sources with overall uncertainties of about 1%. Isomeric ratios, given in $\sigma$ high spin/($\sigma$ high spin + $\sigma$ low spin), of $^{80, 80m}$Br, $^{81,81m}$Se, $^{014, 104m}$Rh, $^{116,116m}$In and $^{134, 134m}$Cs produced by thermal neutron activation were found to be 0.21$\pm$0.01, 0.14$\pm$0.02, 0.12$\pm$0.02, 0.69$\pm$0.07 and 0.058$\pm$0.004, respectively, Those values of $^{80, 80m}$Br, $^{81,81m}$Se, and $^{134, 134m}$Cs Produced by epi-cadmium neutron were found to be 0.19$\pm$0.02, 0.29$\pm$0.02 and 0.074$\pm$0.011, respectively. The experimental values obtained were compared with the theoretical values deduced from the statistical model. There were the general agreements between the theory and the experiment.t.

  • PDF

Evaluation of the effect of blood contamination on the compressive strength of MTA modified with hydration accelerators

  • Oloomi, Kaveh;Saberi, Eshaghali;Mokhtari, Hadi;Mokhtari Zonouzi, Hamid Reza;Nosrat, Ali;Nekoofar, Mohammad Hossein;Dummer, Paul Michael Howell
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.3
    • /
    • pp.128-133
    • /
    • 2013
  • Objectives: This study was performed to evaluate the effect of blood contamination on the compressive strength (CS) of Root MTA (RMTA) modified with Calcium chloride ($CaCl_2$) and Disodium hydrogen phosphate ($Na_2HPO_4$) as setting accelerators over time. Materials and Methods: A total of 110 cylindrical specimens of RMTA were divided into 6 experimental groups as follows: Group1, RMTA; Group 2, RMTA modified with $CaCl_2$ (RMTA-C); Group 3, RMTA modified with $Na_2HPO_4$ (RMTA-N); Group 4, RMTA contaminated with blood; Group 5, RMTA-C contaminated with blood; Group 6, RMTA-N contaminated with blood. The CS of specimens in all groups was evaluated after 3 hr, 24 hr, and 1 wk. In the modified groups (groups 2, 3, 5, and 6) the CS of five specimens per group was also evaluated after 1 hr. Results: Blood contamination significantly reduced the CS of all materials at all time intervals (p < 0.05). After 3 hr, the CS of specimens in the RMTA groups (with and without blood contamination) was significantly lower than those in the RMTA-C and RMTA-N groups (p < 0.05). The CS values were not significantly different at the other time intervals. In all groups, the CS of specimens significantly increased over time (p < 0.05). Conclusions: Blood contamination decreased the CS of both original and accelerated RMTA.