• 제목/요약/키워드: $^{10}Be$

검색결과 256,951건 처리시간 0.149초

장반감기 우주선유발 동위원소, $^{10}Be$과 그 응용 (Long-lived cosmogenic nuclide, Beryllium-10 and its applications)

  • 김경자;;우형주
    • 한국제4기학회지
    • /
    • 제20권2호
    • /
    • pp.30-50
    • /
    • 2006
  • 반감기가 긴 $^{10}Be$ (Beryllium-10)은 지구의 대기뿐만 아니라, 지구의 표면 그리고 다른 행성의 대기와 표면에서도 생성된다. 가속기질량분석기술(AMS)이 1970년 후반기에 개발되면서 지질분야 연구에서 매우 중요한 추적자 중의 하나인 $^{10}Be$ 측정이 가능해졌으며, 이후 지구와 지구외 시료를 이용한 다양한 $^{10}Be$ 응용연구가 방사성탄소 응용연구와 함께 이루어져 왔다. 본 논문은 지구와 행성의 대기와 표면에서의 $^{10}Be$ 생성에 관한 메카니즘과 지형학, 해양학, 고고학, 빙하학, 우주방사화학, 기후학, 그리고 행성학 등의 여러 학문 분야에서의 $^{10}Be$의 응용연구들에 대하여 정리하였으며, 아울러 $^{10}Be$ 가속기질량분석을 이용한 향후 연구과제들을 고찰하였다.

  • PDF

몬테카를로 시뮬레이션을 이용한 하안단구 10Be 수직단면 연대측정 (Cosmogenic 10Be Depth Profile Dating of Strath Terrace Abandonment using Monte Carlo Simulation)

  • 김동은;성영배;김종근
    • 한국지형학회지
    • /
    • 제26권4호
    • /
    • pp.21-31
    • /
    • 2019
  • Timing of terrace formation is a key information for understanding the evolution of fluvial systems. In particular, dating strath terrace (i.e. timing of terrace abandonment) is more difficult than depositional terrace that is conventionally constrained by radiocarbon, OSL and other dating methods targeting samples within terrace deposit. Surface exposure dating utilizing cosmogenic 10Be provides more reliability because it can be applied directly to the surface of a fluvial terrace. Thus, this method has been increasingly used for alluvial deposits. As well as other geomorphic surfaces over the last decades. Some inherent conditions, however, such as post-depositional 10Be concentration (i.e. inheritance), surface erosion rate, and density change challenge the application of cosmogenic 10Be to depositional terrace surface against simple bedrock surface. Here we present the first application of 10Be depth profile dating to a thin-gravel covered strath terrace in Korea. Monte Carlo simulation (MCS) helped us in better constraining the timing of abandonment of the strath terrace, since which its surface stochastically denuded with time, causing unexpected change of 10Be production with depth. The age of the strath terrace estimated by MCS was 109 ka, ~4% older than the one (104 ka) calculated by simple depth profile dating, which yielded the best-fit surface erosion rate of 2.1 mm/ka. Our study demonstrates that the application of 10Be depth profile dating of strath terrace using MCS is more robust and reliable because it considers post-depositional change of initial conditions such as erosion rate.

p-GaSb:Be/GaAs 에피층의 Be 준위에 관한 연구 (A Study of Be Levels in p-GaSb:Be/GaAs Epitaxial Layers)

  • 노삼규;김준오;이상준
    • 한국진공학회지
    • /
    • 제20권2호
    • /
    • pp.135-140
    • /
    • 2011
  • Be을 도핑한 p형 GaSb:Be 에피층의 광여기 발광(PL) 스펙트럼(20 K)의 도핑밀도에 따른 변화를 조사하여, Be 억셉터의 근원을 분석하였다. 도핑을 증가시키면 PL 피크가 고에너지로 변위하고 반치폭은 줄어드는 경향을 보이다가, 밀도가 ${\sim}10^{17}cm^{-3}$ 이상에서 피크 에너지는 오히려 저에너지로 변위하고 반치폭이 늘어나는 현상을 관측하였다. 3개 피크로 분리한 PL 스펙트럼의 적분 PL 강도 변화를 통하여, 도핑 증가에 따라 $Be[Be_{Ga}]$ 준위(0.794 eV)는 감소하는 반면 진성결함에 기인한 $A[Ga_{Sb}]$ 피크(0.778 eV)와 함께 Be과 A 사이에 위치하는 새로운 $Be^*$ 준위(0.787 eV)가 증가하기 때문으로 분석되었다. 이것은 Be을 도핑한 p-GaSb:Be 에피층에는 Be 얕은준위(${\Delta}E=16meV$)와 Be과 A 결함준위가 결합한 $Be^*[Ga_{Sb}-Be_{Ga}]$의 복합준위(${\Delta}E=23meV$)가 공존하기 때문으로 논의하였으며, ${\sim}10^{17}cm^{-3}$ 이상 도핑할 경우에는 Be 준위가 다소 감소할 수 있음을 보였다.

1,10-디벤질트리에틸렌테트라아민과 1,10-디벤질-5R-메틸트리에틸렌테트라아민의 코발트(III) 착물 (Metal Complexes Containing Multidentate Ligands (I). Cobalt (III) Complexes of 1,10-Dibenzyltriethylenetetraamine and 1,10-Dibenzyl-5R-methyltriethylenetetraamine)

  • 전무진
    • 대한화학회지
    • /
    • 제19권2호
    • /
    • pp.98-103
    • /
    • 1975
  • 두개의 리간드 1,10-디벤질트리에틸렌테트라아민 (1,10-$Be_2trien$)과 1,10-디벤질-5R-메틸트리에틸렌테트라아민(1,10-$Be_2$-5R-Metrien)을 합성하고 이들 두 리간드의 디클로로 코발트(III) 착물을 제조하였다. 이 두 테트라아민 리간드는 코발트(III) 이온에 대하여 트란스 기하배위를 아주 잘 형성하였다.

  • PDF

여러 개의 모터에 의하여 제어되는 링-코어 자동 선별기 개발 ((Development of Ring Core Auto-Classifier by Multi-Motor Control))

  • 박인규
    • 전자공학회논문지SC
    • /
    • 제39권2호
    • /
    • pp.104-115
    • /
    • 2002
  • 인덕터 전기 부품을 구성하는 핵심 부품인 링-코어를 물질 특성, 인덕턴스 값 및 Q-값에 따라 10등급으로 분류하는 선별기를 설계하는 데 있어, 한번에 10개의 코어를 동시에 자동 분류할 수 있도록 설계한다. 동시에 10개의 코어를 자동 선별하려면 10개의 측정 장비가 필요한데, 이러한 측정 장비는 대단히 고가이므로, 하나의 측정 장비를 사용하여 10개의 링-코어를 검사한 후, 각각의 등급에 따라서 해당 그릇으로 저장하도록 한다. 이러한 시스템을 개발하는 데 있어서, 초당 0.5개의 생산 속도보다 빠른 속도인 초당 1개 정도로 측정 분류할 수 있는 속도가 필요하다. 시스템의 구성물은 먼저 작업 명령을 내려주고, 각종 생산 및 품질 통계를 관리하는 작업 PC와, 100개의 고무호스, 공급기, 측정기, 10개의 등급-상자, 1개의 메인-보드, 10개의 모터-제어-보드, 10개의 모터-드라이버-보드, 10개의 스텝-모터 등으로 구성되어 있다. 따라서 많은 고장, 오동작이 예상된다. 가장 중요한 사항은 일부의 모터 고장, 일부 모터 드라이버 보드 고장, 일부 모터 제어 보드 등의 고장이 발생하여도 작동이 멈추지 않도록 설계하는 것이다. 이를 위하여 센서 회로 추가 및 관련 소프트웨어 알고리즘을 개발한다.

해안단구 연구를 위한 10Be 연대측정법의 적용과 한계점 (Application of 10Be Dating Technique for Marine Terrace Studies and Its Limitations)

  • 신재열
    • 한국지구과학회지
    • /
    • 제36권6호
    • /
    • pp.512-519
    • /
    • 2015
  • 해안단구와 육상에 남아있는 고해수준에 관한 기록들은 한반도 지반운동의 형태와 속성을 구분해 낼 가장 직접적인 증거로 사용될 수 있음에도 불구하고 아직 고위 해안단구들의 형성시기에 관한 절대연대 측정이 현실적으로 어렵다는 점과 과거 해수면 변동과 지반운동 간의 상대적 변화에 관한 부족한 정보로 인해 명확한 해석과 과학적 논의는 불완전한 상태이다. 본 연구는 한반도 고위 해안단구 연구에서 $^{10}Be$을 대상으로 한 우주선 기원핵종 절대연대 측정법의 실험결과를 보고하고 있다. 실험 결과, 동해안의 강릉시 정동진 일대와 서해안 지역 서천군 비인면 일대에서 채취한 해발고도 80 m 내외의 고위 해안단구 상의 기반암과 거력 퇴적물의 $^9Be/^{10}Be$ 집적량비와 노출 연대는 상대적으로 매우 낮고 젊은 연대를 보이고 있다. 이러한 결과는 실험과정에서의 오류 가능성을 포함하여 고위 해안단구의 복잡한 노출역사를 반영하는 것으로 판단된다. 특히 한반도의 기후환경과 해안단구가 육화된 뒤 겪을 것으로 추정되는 복잡한 노출 환경을 고려할 경우 앞으로 $^{10}Be$ 연대측정기술의 성공적인 적용을 위해서는 적합한 연구지역의 발굴과 시료채취가 가장 중요한 요인이 될 것으로 판단된다.

Influence on Autonomic Function Before, During, and After Transcutaneous Electrical Nerve Stimulation in Senile Patients with Chronic Low Back Pain

  • Lee Mun-Hwan
    • The Journal of Korean Physical Therapy
    • /
    • 제14권3호
    • /
    • pp.174-202
    • /
    • 2002
  • Twenty five patients, 14 males and 11 females with an average age of 75years with chronic Low Back Pain were tested before, during, and after 10minutes transcutaneous electrical nerve stimulation. It is important to consider the effect of TENS on the autonomic function because the pain pathway and the ANS pathway are somehow correlated to each other. There is still controversy among researchers who have reported the effect of TENS on autonomic function. So the purpose of this study is to measure the effect of TENS on the ANS and to see the relation of the pain control mechanism and the change in the ANS. The results were as follows : 1) Systolic blood pressure between before and during the experiment was apt to be a little increased, but statistically there was no significant change(P>.05). 2) Systolic blood pressure between during and after 10 minutes the experiment was apt to be a little decreased, but statistically there was no significant change(P>.05). 3) Systolic blood pressure between before and after 10 minutes experiment was apt to be a little decreased, but statistically there was no significant change(P>.05). 4) Diastolic blood pressure between before and during experiment was apt to be a little increased, but statistically there was no significant change(P>.05). 5) Diastolic blood pressure between during and after 10 minutes experiment was significantly decreased(P<.05). 6) Diastolic blood pressure between before and after 10 minutes the experiment was apt to be a little decreased, but statistically there was no significant change(P>.05). 7) Heart rate between before and during the experiment was apt to be a little decreased, but statistically there was no significant change(P>.05). 8) Heart rate between during and after 10 minutes the experiment was significantly decreased(P<.05). 9) Heart rate between before and after 10 minutes the experiment was significantly decreased(P<.05). 10) Skin temperature between before and during the experiment was significantly increased(P<.05). 11) Skin temperature between during and after 10 minutes the experiment was apt to be a little increased, but statistically there was no significant change(P>.05). 12) Skin temperature between before and after 10 minutes the experiment was significantly increased(P>.05). 13) Respiratory rate between before and during the experiment was apt to be a little increased, but statistically there was no significant change(Pgt;.05). 14) Respiratory rate between during and after 10 minutes the experiment was apt to be a little decreased, but statistically there was no significant change(Pgt;.05). 15) Respiratory rate between before and after 10 minutes the experiment was apt to be a little decreased, but statistically there was no significant change(P>.05).

  • PDF

게임상의 Zombie Character 인지속성에 관한 연구 (Research for The cognitive Properties of Zombie Game Character)

  • 이금준;조동민
    • 한국멀티미디어학회논문지
    • /
    • 제24권5호
    • /
    • pp.717-726
    • /
    • 2021
  • The zombies in AVG games are not divided into different game occupations. To address this issue, this paper starts by selecting those popular zombie games as the research object. Then, a number of samples will be collected from the roles of zombie and these different roles of zombie will be classified by profession depending on the characteristics of these roles. On this basis, the roles will be given a new title to describe their profession. Then, semantic analysis will be conducted to search for the words that can be used to describe the roles of zombie. Besides, there will be 10 experts in design and 10 professional zombie game players invited to choose from the collected adjectives. The most selected words will be used in this study to conduct cognition assessment, before the making of questionnaire. Then, the questionnaire data will be collected and converted into a statistical model form for indicating the value of ability by group and profession.

표면처리별 S10T, 10.9HRC 고장력 볼트 세트의 체결 품질 연구 (The Joining Quality of High Strength Bolt, Nut and Washer Set (S10T & 10.9HRC) under the Surface Treatment Conditions)

  • 최윤오;석한길;홍현선
    • 한국표면공학회지
    • /
    • 제48권3호
    • /
    • pp.93-99
    • /
    • 2015
  • This test focuses on the correlations between joining axial force at non-room temperature and at room temperature according to the surface treatment (Geomet, Dacro, Green Kote, Armore Galv.). The quality characteristics of the fastening axial force required by the KSB 2819 and EN14399-10 standards were discussed. Surface treatment was implemented to S10T and 10.9HRC sets of bolts under the same environmental factors. Development for the stabilization of the fastening axial force required by each standard should continually be enforced, and the fastening and storage in the field should be maintained at room temperature. Managing stabilization of torque enumerated data is required after application of surface treatment. It is concluded that, by conducting the test of applying surface treatment to effectively manage, each lot-specific rate of axial force at room temperature conditions should be maintained below the maximum 4.47%. The decline rate of axial force should be maintained under 2.15% maximum, and the standard deviation of the room temperature condition should be maintained below 0.5.

열처리된 Be-Cu 합금 계면에서 전류-전압 특성 (Current-Voltage Characteristics at Annealed Be-Cu Alloy Interfaces)

  • 천장호;부종욱
    • 전자공학회논문지A
    • /
    • 제28A권12호
    • /
    • pp.31-38
    • /
    • 1991
  • The current-voltage characteristics at annealed Be-Cu alloy(1.8-2 wt% Be, 0.2 wt% Co+Ni) interfaces have been studied by means of the cyclic voltammetric method. The specimens were annealed in nitrogen gas($N_{2}$) furnace at 36$0^{\circ}C$ for 1.5 hours. After annealing, the vickers hardness(HV) was increased from 210 to 385. The used solutions were distilled water(H$_{2}$O), 10$^{-3}M\;CsNO_{2},10^{-2}M\;KCl,10^{-2}M\;KOH,10^{-4}M\;H_{2}SO_{4}$ aqueous electrolytes, and ethylalcohol ($C_{2}H_{5}OH$), etc. The cyclic voltammograms showed significant current-voltage characteristics between the annealed and unannealed specimens at the same conditions. The age hardening and the related surface potential barrer and dissolution effects have been observed during the whole experimental process. The dissolution process of annealed Be-Cu alloys was effectively retarded by the age hardening phenomenon. The age hardening effect also raised the surface potential barrier of Be-Cu alloys. The interfacial phenomena of Be-Cu alloys seem to be one of good models for understanding the activation process.

  • PDF