• 제목/요약/키워드: $\rho$-power

검색결과 351건 처리시간 0.027초

Corrosion effects on tension stiffening behavior of reinforced concrete

  • Shayanfar, M.A.;Ghalehnovi, M.;Safiey, A.
    • Computers and Concrete
    • /
    • 제4권5호
    • /
    • pp.403-424
    • /
    • 2007
  • The investigation of corrosion effects on the tensile behavior of reinforced concrete (RC) members is very important in region prone to high corrosion conditions. In this article, an experimental study concerning corrosion effects on tensile behavior of RC members is presented. For this purpose, a comprehensive experimental program including 58 cylindrical reinforced concrete specimens under various levels of corrosion is conducted. Some of the specimens (44) are located in large tub containing water and salt (5% salt solution); an electrical supplier has been utilized for the accelerated corrosion program. Afterwards, the tensile behavior of the specimens was studied by means of the direct tension tests. For each specimen, the tension stiffening curve is plotted, and their behavior at various load levels is investigated. Average crack spacing, loss of cross-section area due to corrosion, the concrete contribution to the tensile response for different strain levels, and maximum bond stress developed at each corrosion level are studied, and their appropriate relationships are proposed. The main parameters considered in this investigation are: degree of corrosion ($C_w$), reinforcement diameter (d), reinforcement ratio (${\rho}$), clear concrete cover (c), ratio of clear concrete cover to rebar diameter (c/d), and ratio of rebar diameter to reinforcement percentage ($d/{\rho}$).

파라-치환 브롬화 벤질의 가용매 분해반응 메카니즘 (The Solvolytic Reaction Mechanism of p-Substituted Benzyl Bromides)

  • 이익춘;엄태섭;성대동;이종팔;박현석
    • 대한화학회지
    • /
    • 제34권1호
    • /
    • pp.10-18
    • /
    • 1990
  • 파라-치환 브롬화 벤질의 가용매 분해반응을 DMSO-$H_2O$과 DMF-$H_2O$ 혼합용매계에서 속도론적으로 연구 하였다. 이 두 혼합용매계의 이온화력(Y)와 친핵도($N_{BS}$)를 결정하기 위하여 같은 혼합용매속에서 1-adamantyl halides, t-butyl halides 그리고 methyl tosylate를 가용매 분해반응시켰다. 각 DMSO-$H_2O$ 혼합용매에 대한 분광용매화 파라미터는 측정된 νmax를 Taft의 관계식에 대입시켜 결정하였다. 파라-치환 브롬화 벤질의 가용매 분해반응은 m, l값과 ${\beta},{\rho}_s$값으로 보아 전이상태에서 결합형성이 약간 우세한 경계반응 메카니즘으로 진행함을 알았다.

  • PDF

광역 전력계통 주파수 감시망 적용을 위한 광역계통주파수의 전파속도에 관한 연구 (Study on the Propagation Speed of the wide-area power system frequency for the application of FNET)

  • 국경수;노대석
    • 한국산학기술학회논문지
    • /
    • 제10권8호
    • /
    • pp.1824-1831
    • /
    • 2009
  • 본 논문은 대규모 전력 송전망에서 발전기가 사고로 인해 순간적으로 전력공급을 중단하게 되었을 때 과도기간 동안 나타나는 전력계통 주파수의 급강하가 탈락된 발전기의 위치로부터 전력 송전망 전체로 파급되어 가는 전파속도를 분석한다. 이러한 전력계통 주파수 동요의 전파속도는 전력계통 고유의 특성에 따라 다르게 나타나기 때문에 광역적 측면에서 전력 수송망의 특성을 이해하는데 중요한 파라미터이며, 최근 미국의 전력 송전망을 대상으로 운영중인 광역 전력계통 주파수 감시스템(FNET)을 활용한 전력 IT 적용연구에서 중요한 파라미터로 활용되고 있다. 본 논문에서는 방대한 규모를 가진 미 동부의 전력송전 연계계통에 대해 최근의 동적모델을 사용하여 다양한 위치에서의 발전기 탈락을 모의한 후 이에 따른 전력계통주파수 동요의 전파 특성을 분석하고 그 전파속도를 제시한다.

태양광전원 계통연계시험장치에 의한 수용가 전력품질특성에 관한 연구 (Analysis of Customer Power Quality Characteristics Using PV Test Devices)

  • 김병목;김병기;박재범;노대석
    • 한국융합학회논문지
    • /
    • 제2권4호
    • /
    • pp.21-27
    • /
    • 2011
  • 현재 신 재생에너지 보급사업에 의해 설치되고 있는 태양광전원설비가 전력계통과 연계 운영될 경우 배전계통의 전력품질 요소에 어떠한 영향을 미치고 있는지를 모의시험을 통해 정확히 측정 분석하여 향후 분산형전원의 확대 보급에 따른 가이드라인의 구축과 기술적인 연계지침이 필요한 상황이다. 따라서 본 논문에서는 태양광이 연계되는 위치에 따른 선로임피던스($R{\pm}jX$)에 의하여 생기는 전압상승 및 하강에 의한 전력품질[Sag/Swell] 저하 현상에 대하여 태양광전원용 LabVIEW 프로그램을 통해 전력품질 시험을 수행하여 그 특성을 분석한다.

Effects of the Low Power He-Ne IR Laser Treatment on the Liver Damage Induced with $CCI_4$ in Rats

  • Rho Min-Hee;Kim Jai-Young
    • 대한의생명과학회지
    • /
    • 제10권3호
    • /
    • pp.231-235
    • /
    • 2004
  • This study was investigated the effects of the lower power He-Ne IR laser treatment on the changes of blood biochemical components in the rat liver damaged by the carbon tetrachloride (CCl₄). The twenty one Sprague-Dawley adult male rats weights (260±18.6 g) were designed to the three groups: one control group and two experimental groups, the experimental groups were divided into the CCl₄-treated groups and the laser therapy group (CCl₄+ Laser). The experimental groups were injected twice with CCl₄(1.0 ml/kg body weight) intraperitoneal for two days. Each group was sacrificed after two weeks irradiated with the lower power He-Ne IR laser for ten minutes per every day. The activity of alanine aminotransferase (ALT), lactic dehydrogenase (LDH), alkaline phosphatase (ALP) and the concentration of serum glucose treated with He-Ne IR laser groups was significantly decreased to the conrtol (treated with carbon CCl₄) group. The activity of aspartate aminotransferase (AST) was decreased in the laser group but not significantly, the concentration of the serum cholesterol in the laser group was significantly increased comparing with the control and case control groups. In conclusion, the effect of the lower power He-Ne IR laser treatment is believed to be a possible protective effects for CCl₄ induced acute hepatotoxicity in rats.

  • PDF

수평축 조류발전 터빈 설계 및 후류 특성 분석 (Design of Horizontal Axis Tidal Current Power Turbine with Wake Analysis)

  • 조철희;김도엽;이강희;노유호;김국현
    • 신재생에너지
    • /
    • 제7권3호
    • /
    • pp.92-100
    • /
    • 2011
  • With the increased demand of clean energy and global warming measures, the renewable energy development has been increased recently. The TCP (Tidal Current Power) is one of the ocean renewable energy sources. Having the high tidal energy source in Korea, there are many potential TCP sites with strong current speed. The rotor, which initially converts the energy, is a very important component because it affects the efficiency of the entire system. The rotor performance is determined by various design parameters including number of blades, shape, sectional size, diameters and etc. However, the interactions between devices also contribute significantly to the energy production. The rotor performance considering the interaction needs to be investigated to predict the exact power in the farm. This paper introduces the optimum design of TCP turbine and the performance of devices considering the interference between rotors.

배전계통에 있어서 분산전원 연계 판정 시뮬레이션 결과 분석에 관한 연구 (The Analysis of the interconnection Simulation Result for Dispersed Sources in Distribution Systems)

  • 강민관;박재호;노대석;오용택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.90-92
    • /
    • 2006
  • 국가차원의 신 재생에너지 활성화 방안에 따라 지자체 등의 분산전원 시실계획이 점차 증가하고 있으나, 아직 우리나라에서는 분산전원의 배전계통 연계에 대한 체계적인 기술지침이 초기 단계에 있거나 제정 중에 있어서, 계통 연계와 관련하여 발전사업자와 전력회사간의 이해가 상충되는 등 문제점이 발생되고 있다. 또한, 대규모 분산전원 단지의 도입이 이루어지고 있으나, 이에 대한 기술적인 평가방안이나 해석 방법이 구체적으로 제시되어 있지 않아, 설치자(시도 및 지자체)와 운용자(한전의 배전지사/지점)들은 많은 혼돈과 어려움을 겪고 있는 실정이다. 따라서 본 논문에서는 태양광, 풍력 등의 분산전원이 배전계통에 도입되는 경우, 연계에 대한 기술적인적합여부를 종합적으로 평가 할 수 있도록 분산전원 연계판정 시뮬레이션 시스템을 연구하였다. 즉, 구체적으로는 전력용량, 전기방식, 역률, 뱅크 역 조류, 상시전압변동, 순시전압변동, 플리커, 단락용량, 연계가능용량 등이며, 이들 항목을 계통연계 가이드라인과 평가 알고리즘에 의하여 연계 적합 여부를 판단해 주는 시스템이다.

  • PDF

CFD를 이용한 수평축 조류발전 로터 성능의 기초연구 (Fundamental Study on the HAT Tidal Current Power Rotor Performance by CFD)

  • 조철희;임진영;이강희;채광수;노유호;송승호
    • 신재생에너지
    • /
    • 제5권2호
    • /
    • pp.3-8
    • /
    • 2009
  • Tidal current power system is one of ocean renewable energies that can minimize the environmental impact with many advantages compared to other energy sources. Not like others, the produced energy can be precisely predicted without weather conditions and also the operation rate is very high. To convert the current into power, the first device encountered to the incoming flow is the rotor that can transform into rotational energy. The performance of rotor can be determined by various design parameters including numbers of blade, sectional shape, diameter, and etc. The stream lines near the rotating rotor is very complex and the interference effects around the system is also difficult to predict. The paper introduces the experiment of rotor performance and also the fundamental study on the characteristics of three different rotors and flow near the rotor by CFD.

  • PDF

근거리 무선통신(NFC) 기반의 대기전력 차단 클라이언트 설계 (Design of Standby Power Shut-off Client Based on Near Field Communication)

  • 전중창;노진송;최경선
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 춘계학술대회
    • /
    • pp.978-980
    • /
    • 2013
  • 본 연구에서는 멀티탭에 근거리 무선통신(NFC) 모듈을 접목한 대기전력 차단 클라이언트 시스템의 개념을 제안하고, 클라이언트 시스템의 기본적인 하드웨어 구성과 소프트웨어 제어 개념도를 제시하였다. 이 시스템은 가정, 중/대형 사무실, 학원, 공장, 아파트 단지, 하우스 등 근거리통신을 이용하여 통합제어가 필요한 장소에 적용가능하다. 대기전력 관리 및 전력사용량 관리를 통하여 사무/가전기기들의 대기전력을 제어하여서 소비되는 총 전력을 줄이고, 전력 에너지 및 비용을 절감하는 효과가 기대된다.

  • PDF

Micro-grid의 적정전압유지를 위한 자율분산 협조운용 제어알고리즘 (Autonomous Decentralized Coordination Control Algorithm for Keeping the voltage of Micro-grid within a Proper Level)

  • 김재언;신성수;노대석;윤기갑
    • 한국산학기술학회논문지
    • /
    • 제10권1호
    • /
    • pp.81-90
    • /
    • 2009
  • 전력산업의 구조개편과 더불어 분산전원의 배전계통연계운용 및 전력품질이 전력회사의 배전사업자, 구역전기사업자, 전기공급 신뢰도와 밀접한 관계에 있는 산업용 수용가들에게 많은 관심을 불러일으키고 있다. 이러한 주변정세는 차세대의 배전계통이 다수의 Micro-grid들로 구성될 것이라고 하는 예상을 전문가들로부터 제기되기에 이르렀다. 그러나, 제안된 Micro-grid는 몇몇의 분산전원과 전력품질을 보상하는 기기, 그리고 통신제어설비와 부하들로 구성된다는 기본적인 내용에 지나지 않는다 따라서, 본 논문에서는 수용가에 고신뢰 고품질의 전력공급을 가능하게 하는 차세대 전력공급네트워크인 Micro-grid의 적정전압유지를 위한 자율분산협조 운용제어 알고리즘을 제안한다.