• Title/Summary/Keyword: $\rho$-power

Search Result 351, Processing Time 0.028 seconds

A development on remote monitoring technology of distribution transformer using CDMA wireless data communication (CDMA무선 데이터통신을 이용한 배전용변압기 원격감시 기술개발)

  • Park, Chang-Ho;Rho, Whang-Rae;Kim, Jun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.483-485
    • /
    • 2000
  • This paper presents the operation technology and the remote monitoring system of distribution pole transformer. Especially, this system uses CDMA wireless data communication network as media which is serviced on a national scale. It has four major components such as sensor for measuring the secondary voltage and currents of distribution transformer, CDMA wireless modem for data modulating/demodulating, communication media for sending/receiving of data, and PC server for monitoring the results of sensing or computing information. This paper also describes the configuration of each component's functions with its development process.

  • PDF

Three-Level ZVZCS DC/DC Converter using a Assistance Power Sources of the RailRoad Vehicles (철도차량 보조전원용 Three-Level ZVZCS DC/DC 컨버터)

  • Rho S.C.;Lim E.K.;Yang S.H.;Kim Y.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.880-885
    • /
    • 2003
  • Using a Assistance Power Sources of the Railroad Vehicles Three-Level ZVZCS DC/DC Converter is presented in this paper. The proposed three-Level DC/DC Converter Is to achieved zero voltage and zero current switching for the two Main switches. phase shift method is used a parastic capacitance by reverse recovery characteritics in a inner diode of the switching device. Also. using a diode second part of the Transformer by the simple auxiliary circuit for the achieved zero current switching of the Auxiliary switch. For the ZVZCS movement of the all switching devices is analyzed and verified under a 5kW, in the 100kHz switching frequency.

  • PDF

Development of Interconnection Algorithm for PV Systems in Distribution System (태양광발전의 배전계통 연계 알고리즘 개발에 관한 연구)

  • Park Jae-Ho;Rho Dae-Seok;Oh Yong-Taek;Hong Sangeun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2005.05a
    • /
    • pp.128-131
    • /
    • 2005
  • 본 논문에서는 정해진 형태의 정보를 입력하면 태양광, 풍력 등의 분산형전원의 도입 및 운용에 대한 각종 정보를 상세하고 전문적(설계나 감리, 운용자 등)인 측면에서 제공받을 수 있는 시스템의 알고리즘을 개발하고자 한다. 구체적으로는 분산형전원의 계통연계 시에 발생할 수 있는 정상, 비정상(사고), 전력품질에 대한 9개의 항목으로 전력용량, 전기방식, 역률, 뱅크 역조류, 상시전압변동, 순시전압변동, 플리커, 단락용량, 연계가능용량 등이며, 분산형전원의 배전계통에의 연계 적합 여부를 종합적으로 판단하는 시스템이다.

  • PDF

The Study on the Necessity for the Interconnection between Generation and Transmission Expansion Planning (발전설비계획과 계통계획의 연계에 대한 필요성 검토)

  • Shin, Y.G.;Rho, J.H.;H.Kim, Bal-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.44-47
    • /
    • 2001
  • In a competitive environment of electric power industy, the level of uncertainty increase due to generation investment decisions creating new challenge to transmission system planner. The use of a locational signal and the provision of a indicative plan to control the generation investment reasonably is very important in the viewpoint of a regulator. The main target of this stuty is to emphasize on the necessity for considering simultaneously both generation and transmission expansion plan. This paper demonstrate the many case studies to make certain of the necessity for the interconnection between generation and transmission planning. In addition to, the planning in Korea power industry is considerd.

  • PDF

The Study on Unified Power Quality Conditioner(UPQC) Aiming at the Integration of Series-active and Shunt-Active Filter (직렬형과 병렬형 능동필터를 조합한 통합형 전력품질 개선장치에 관한 연구)

  • Lee, Hyun-Ok;Rho, Dae-Seok;Oh, Sung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.305-307
    • /
    • 2001
  • This paper deals with single-phase unified power quality conditioner(UPQC), which aims at the integration of series-active and shunt-active filter. The series filter is used to compensate for the voltage distortions and the shunt filter is used to provide reactive power and counteract the harmonic current injected by the load. Also, the voltage of the DC link capacitor is controlled to a desired value by the shunt active filter. The performance of UPQC under load nonlinearities conditions is investigated using simulation as well as experimental results.

  • PDF

경량전철의 전원공급선에 의해 발생되는 자기장 차폐해석

  • Song MK;Oh YS;Kim DH;Joo MS;Rho SK;Lee SJ;Park JD;Chung SG;Jeong RG;Cho HS
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.547-551
    • /
    • 2003
  • This paper presents the magnetic fields shielding properties of the light rail transit which are produced by the ripple-shaped currents in the power lines. To analyze these properties, the equivalent circuit model of the DC power supply system at the light rail transit system was induced by MATLAB-SIMULINK, and with the calculated results of the ripple-shaped currents, the magnetic fields shielding properties of the light rail transit were analyzed. The results are as follows. First The frequency of the ripple-shaped currents is 200[Hz] and its magnitude is 1.5[A]. Second the magnetic fields produced by the ripple-shaped currents of the DC power supply systems are well shielded by the aluminum made body of the light rail transit.

  • PDF

Grid Peak Power Limiting / Compensation Power Circuit for Power Unit under Dynamic Load Profile Conditions (Dynamic Load Profile 조건의 전원 장치에 있어서 계통 Peak Power 제한/보상 전력 회로)

  • Jeong, Hee-Seong;Park, Do-Il;Lee, Yong-Hwi;Lee, Chang-Hyeon;Rho, Chung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.376-383
    • /
    • 2022
  • The improved performance of computer parts, such as graphic card, CPU, and main board, has led to the need for power supplies with a high power output. The dynamic load profile rapidly changes the usage of power consumption depending on load operations, such as PC power and air conditioner. Under dynamic load profile conditions, power consumption can be classified into maximum, normal, and standby power. Several problems arise in the case of maximum power. Peak power is generated at the system power source in the maximum-power situation. Frequent generation of peak power can cause high-frequency problems and reduce the life of high-pressure parts (especially high-pressure capacitors). For example, when a plurality of PCs are used, system overload occurs due to peak power generation and causes problems, such as power failure and increase in electricity bills due to exceeded contract power. To solve this problem, a system peak power limit/compensation power circuit is proposed for a power supply under dynamic load profile conditions. The proposed circuit detects the system current to determine the power situation of the load. When the system current is higher than the set level, the circuit recognizes that the system current generates peak power and compensates for the load power through a converter using a super capacitor as the power source. Thus, the peak power of loads with a dynamic load profile is limited and compensated for, and problems, such as high-frequency issues, are solved. In addition, the life of high-pressure parts is increased.

A Study on the Countermeasure Algorithm for Power System Disturbances in Large Scale Fuel Cell Generation System (대용량 연료전지시스템의 계통외란 방지알고리즘에 관한 연구)

  • Choi, Sung-sik;Kim, Byung-ki;Park, Jae-beom;Rho, Dae-seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.711-717
    • /
    • 2016
  • Recently, fuel cell generation system with high energy efficiency and low CO2 emission is energetically interconnected with distribution power system. Especially, MCFC(molten carbonate fuel cell) operating at high temperature conditions is commercialized and installed as a form of large scale power generation system. However, it is reported that power system disturbances such as harmonic distortion, surge phenomenon, unbalance current, EMI(Electromagnetic Interference), EMC (Electromagnetic Compatibility) and so on, have caused several problems including malfunction of protection device and damage of control devices in the large scale FCGS(Fuel Cell Generation System). Under these circumstances, this paper proposes countermeasure algorithms to prevent power system disturbances based on the modelling of PSCAD/EMTDC and P-SIM software. From the simulation results, it is confirmed that proposed algorithms are useful method for the stable operation of a large scale FCGS.

Study on the Suitability of Composite Materials for Enhancement of Automotive Fuel Economy (자동차 연비향상을 위한 복합재료 적용 타당성에 관한 연구)

  • Ju, Yeon Jin;Kwon, Young-Chul;Choi, Heung Soap
    • Composites Research
    • /
    • v.32 no.5
    • /
    • pp.284-289
    • /
    • 2019
  • In the present paper, the dynamic force-moment equilibrium equations, driving power and energy equations are analyzed to formulate the equation for fuel economy(km/liter) equivalent to the driving distance (km) divided by the fuel volume (liter) of the vehicle, a selected model of gasoline powered KIA K3 (1.6v). In addition, the effects of the dynamic parameters such as speed of vehicle (V), vehicle total weight(M), rolling resistance ($C_r$) between tires and road surface, inclined angle of road (${\theta}$), as well as the aerodynamic parameters such as drag coefficient ($C_d$) of vehicle, air density(${\rho}$), cross-sectional area (A) of vehicle, wind speed ($V_w$) have been analyzed. And the possibility of alternative materials such as lightweight metal alloys, fiber reinforced plastic composite materials to replace the conventional steel and casting iron materials and to reduce the weight of the vehicle has been investigated by Ashby's material index method. Through studies, the following results were obtained. The most influencing parameters on the fuel economy at high speed zone (100 km/h) were V, the aerodynamic parameters such as $C_d$, A, ${\rho}$, and $C_r$ and M. While at low speed zone (60 km/h), they are, in magnitude order, dynamic parameters such as V, M, $C_r$ and aerodynamic ones such as $C_d$, A, and ${\rho}$, respectively.

A Study on the Small-Signal Stability Improvement Method Using Static Var Compensator (무효전력보상기를 이용한 미소신호안정도 개선방안에 관한 연구)

  • Lee, Su-Hyun;Rho, Kyu-Min;Kim, Deok-Young;Kwon, See-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1064-1066
    • /
    • 1997
  • This paper proposes an efficient algorithm of designing PSS and CSS. First, the stabilizer input variable is selected using the participation matrix. Secondly, the stabilizer constants are decided using first order eigenvalue sensitivity. The proposed method was validated to sample power system.

  • PDF