• 제목/요약/키워드: "drop in" Performance test

검색결과 271건 처리시간 0.031초

무기질계 영구거푸집의 성능평가를 위한 실험적 연구 (The Experimental Study for Inorganic Permanent Form's Performance Evaluation)

  • 김용성;강병훈;김우재;정병훈;정재영;정상진;김광수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2001년도 학술논문발표회
    • /
    • pp.1-7
    • /
    • 2001
  • To do performance evaluations about inorganic permanent form mixed in admixture(fly ash, silica fume) and after placed concrete, it is examined reinforcement materials in the permanent form from shear strength, bond strength and flexural strength tests. In this study, permanent form was inserted with reinforcement metal fitting is strength-tested in several method. The result of this study is belows. (1) In bond strength test, Most specimens are satisfied with criterion-6 kgf/$cm^2$. (2) Irrelative with the inserted metal fitting's shape, unevenness and aggregate, Permanent form and after placed concrete have good condition in the shear strength test. (3) In flexural test, there is no drop out of permanent form. Most cracks are located in nearby the strain point.

  • PDF

베어관을 이용한 30RT급 하이브리드 밀폐형 냉각탑의 성능특성에 관한 실험적 연구 (An Experimental Study on Performance Characteristic of 30RT Closed-Type Hybrid Cooling Tower using Bare Tube)

  • 전철호;이호생;문춘근;김재돌;윤정인
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.1096-1101
    • /
    • 2005
  • In this study, the experiment of thermal performance about closed-type hybrid cooling tower was conducted. A closed type cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The test section for this experiment has the process that the cooling water flows from top part of heat exchanger to bottom side in the inner side of tube, and spray water flows gravitational direction in the outer side of it. Air contacts of tube outer side are counterflow. The heat transfer pipe used in this experiment is a bare type tube having an outside diameter of 15.88mm. In this experiment, heat performances of the cooling tower are calculated such as overall heat transfer coefficient of between the process fluid and air, cooing capacity and pressure drop.

  • PDF

초고압 공간지를 이용한 포터블 인플레터블 카약 제작 (Manufacture of Portable Inflatable Kayak Using Ultra High Pressure Drop Stitch)

  • 박찬홍;박병호;박종대;성현경;임이영
    • 한국항해항만학회지
    • /
    • 제37권5호
    • /
    • pp.551-557
    • /
    • 2013
  • 본 논문에서는 초고압 특수 공간지를 활용한 다기능 포터블 카약을 제작하였다. 초고압 특수 공간지를 활용한 설계로 기존의 인플레터블 카약의 성능을 개선하여 하드쉘 카약의 성능에 근접하도록 제작하였다. 하드쉘 카약의 성능과 인플레터블 카약의 기능성 및 휴대성의 장점을 모두 가진 카약을 제작하였으며, 시제품 성능평가를 통해 기존 하드쉘 카약과의 성능을 비교하였다. 저항성능 검증결과는 목표속도 6knot에 대해 Hobie KONA kayak에 비해 Developed kayak이 12.33% 저항성능이 우수하였다. 경사시험결과는 동일배수량일 경우 Hobie KONA kayak 보다 Developed kayak의 무게중심이 선저를 기준으로 22.7% 낮게 분포하고 있으며, 이는 Hobie KONA kayak 보다 Developed kayak의 무게중심이 낮음으로 복원팔(GZ)에 대한 차이가 일정부분 감소된다. 선체 복원력에서는 Hobie KONA kayak이 약간 우수한 성능을 보여주었으나, 선회력과 저항계수면에서 Developed kayak이 더 우수한 결과를 보였다.

정상유동에서 유동형 단엽폴리머 인공판막의 수력학적 성능평가 (Hydrodynamic Investigation of a Floating-type Monoleaflet Polymer Valve under Steady Flow Condition)

  • 김준우;박복춘
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.49-60
    • /
    • 1996
  • An experimental investigation was performed under steady flow condition to assess hydrodynamic performance of floating-type monoleaflet polymer valves (MLPV) withdifferent leaflet thickness. The St. Jude Medical valve (SJMV) was also used for comparison test. Pressure drops of MLPVS are larger than those for other types of polymer valves and mechanical valves. Furthermore, the thicker is the leaflet thickness of the polymer valve, the larger are the corresponding pressure drop. The velocity profiles for MLPs reveal a large reversed flow region downward to the valve position. The maximum wall shear stresses of MLPVS at a flow rate of $30{\ell}$/min are in the range 50-130 dyn/$cm^2$, and the corresponding maximum Reynolds shear stresses are in the range of 100-500 dyn/$cm^2$, respectively, which are beyond the allowable limit clinically. In contrast, floating-type monoleaflet polymer valves show better hydrodynamic performance in leakage volume. From the designing point of view, it may be concluded that the optimum thickness of leaflet for better hydrodynamic performance is one of the Important parameters.

  • PDF

COMPARISON OF THE FIRE SUPPRESSION PERFORMANCE OF HALON REPLACEMENT AGENTS

  • Kim, Andrew K.;Joseph Z. Su
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.542-549
    • /
    • 1997
  • HFC-227ea and HCFC Blend A were evaluated using full-scale fire tests to obtain information on their fire suppression performance, drop-in capability, thermal decomposition products and physical behaviour of the agent such as its flow characteristics in the piping system. Also, full-scale tests were conducted with Halon 1301 to provide a basis for comparison. Halon 1301, at concentrations of 5% to 7.5%, showed effective total-flooding fire- extinguishing performance for all test scenarios. HFC-227ea, at a design concentration of 7.6% or higher, and HCFC Blend A, at a design concentration of 12%, extinguished all fires in the test facility, however, these agents produced higher concentrations of acid gases than Halon 1301. The quantity of the acid gases generated during fire suppression was dependent on agent concentration, agent discharge time, fire type and size as well as extinguishment time.

  • PDF

CFT와 합성보로 이루어진 CJS합성구조시스템의 내진성능 실험 연구 (Experimental Study of the Seismic Performance of CJS Hybrid Structural Systems Connected to the CFT Column)

  • 임창규;신지욱;문아해;김용남;이기학
    • 한국지진공학회논문집
    • /
    • 제26권2호
    • /
    • pp.83-93
    • /
    • 2022
  • In this study, to verify the structural performance of the Composite Joint System (CJS) hybrid structural model, a cyclic load test was performed and evaluated and verified through the test. To verify the structural performance of the CJS hybrid structural systems' joint and evaluate the seismic performance, four three-dimensional real-size specimens were developed with three internal beam-column specimens and one external beam-column specimen. The three interior column specimens were classified by different methods of joining the upper column and lower column, and the same bonding method as the primary specimen was used for the exterior column. The structural performances in terms of drift, strength, and energy dissipation capacity were analyzed and compared based on the experimental results. From the displacement-based loading experiment, all specimens showed a lateral drift of 4.0% without any significant strength drop and stable energy dissipation capacity.

환형 공명기가 설치된 소음기 설계 및 성능 시험 (Design and Performance Test of Silencers with Ring-shaped Resonators)

  • 김봉기;김상렬;이성현;이종화;이해성
    • 한국소음진동공학회논문집
    • /
    • 제21권4호
    • /
    • pp.357-364
    • /
    • 2011
  • In this study, ring-shaped acoustic resonators were proposed to be installed in a silencer to increase the acoustic performance of silencer in the low-frequency range. Evaluation of noise reduction performance of acoustic resonator arrays was carried out by measuring the random-incidence absorption coefficient. It was found that the absorption coefficient of resonator array was measured up to 1 at 125 Hz of 1/3-octave band center frequency. Insertion losses of silencers with ring-shaped acoustic resonator arrays were measured based on ISO 7235. The results were shown that the ring-shaped resonator could increase the insertion loss up to 13 dB without flow, whereas 7 dB when flow speed reached 15 m/s. As increasing the flow speed above 15 m/s, the effect of acoustic resonator decreased due to the effect of nonlinear air damping of the resonator. It was also found that the increment of pressure drop by the presence of resonator arrays was about 9 % at flow speed of 25 m/s.

현장 실험을 통한 Sputter Coating 컬러 BIPV 모듈의 발전성능 평가 (Performance Assessment of Sputter-Coating-Colored BIPV Modules Through Field Test)

  • 이효문;윤종호;김현일;이건환
    • 한국태양에너지학회 논문집
    • /
    • 제40권5호
    • /
    • pp.1-12
    • /
    • 2020
  • To assess the performance and characteristics of colored building-integrated photovoltaic (BIPV) modules, a comparative assessment of empirical performance was conducted on colored BIPV modules (gray, blue, and orange) and general BIPV module. These modules were installed on the south-facing slope (30°) for comparative assessment through a field test. Monitoring data were collected every 10 min from December 20, 2019 to January 21, 2020 and used to performance and characteristics analysis. Performance ratio and module efficiency were utilized during performance indexing for comparative assessment. For general BIPV modules, the operational efficiency was analyzed at 16.63%, whereas for colored BIPV modules, 13.70% (gray), 15.12 % (blue), and 14.49% (orange) were analyzed. It was discovered that the efficiency reduction caused by transmission losses owing to the application of colored cover glasses were 17.74% (gray), 9.05% (blue), and 9.86 % (orange), under field testing conditions. These values turned on an additional 7% reduction in efficiency for gray BIPV modules, compared to the degradation resulting from transmission drop (gray: 10.87%, blue: 8.99%, and orange: 9.02%) calculated using the efficiency of each module in standard test conditions (STC). Performance ratio analysis resulted in the following values: 0.92 for general BIPV modules, and 0.85 (gray), 0.91 (blue), and 0.91 (orange) for colored BIPV modules. As demonstrated by the above results, modules with a colored cover glass may differ in their operational performance depending on their color, unlike general modules. Therefore, in addition to the performance evaluation under STC, additional factors of degradation require consideration through field test.

홴싱크의 입구 봉쇄에 따른 유동 및 냉각 특성에 관한 연구 (A Study on the Flow and Cooling Characteristics with the Inlet Blockage of a Fan-Sink)

  • 이경용;최영석;윤재호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.83-88
    • /
    • 2004
  • In this study, the flow and thermal performance of the heat sink and fan-sink were experimentally studied to predict the operating condition of the fan-sink. The experiments of the flow and thermal resistance of the heat sink with various inlet blockage, which were occurred by the shapes of the axial fans, were conducted for the proof of the effects of the inlet blockages. The greater the inlet blockage of the heat sink, the higher the pressure drop and lower the thermal resistance of the heat sink will be. The operating point of the fan-sink was predicted by the pressure drop curve with the inlet blockage, which was corresponded to the selected fan and the fan performance curve, and verified by the performance test of the fan-sink. The predicted operating point of the fan-sink had good agreement with the result of the performance test of the fan-sink within $0.7\%$ of the volume flow rates. Measured thermal resistance of the fan-sink was equivalent to that of the heat sink with the same inlet blockage of the fan-sink. It was shown that the heat transfer characteristics of the heat sink were influenced by the flow interaction between the selected fan and the heat sink. To improve the thermal resistance of the heat sink, it is necessary to consider appropriate flow patterns of the fan outlet entering into the heat sink.

  • PDF

웹사이트 메뉴 Depth를 줄이는 방식간의 비교 분석 (Analysis of the Methods to Decrease the Depth of Menu in Web Site)

  • 박희석;김유노
    • 대한인간공학회지
    • /
    • 제19권3호
    • /
    • pp.61-75
    • /
    • 2000
  • To enhance web site's usability, it has been suggested that the depth of tree structured menus should be minimized. In this research, experimental results are reported to quantitatively compare the methods currently used for reducing the depth of menus in web sites. 25 popular web sites were selected and their menu types were categorized into four types: top menu, drop-down menu, boolean menu, and table of contents. The four types of menu were then sub-categorized into 15 different types according to their sub-menu type, existence of menu colors, and the event occurring after mouse activation. Performance tests and subjective evaluation were carried out. The results showed that there were no significant differences in terms of response time among the 15 menu types, while table of contents and drop-down in which the first and second level of menus were visible induced the least number of errors. In the subjective test, the top-menu structure with colors and presentation of its sub-menu without clicking mouse were preferred.

  • PDF