Browse > Article
http://dx.doi.org/10.4070/kcj.2011.41.3.164

Implantable Cardioverter-Defibrillator Lead Extraction by Conventional Traction and Counter-Traction Technique  

Park, Jong-Sung (Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University Health System)
Pak, Hui-Nam (Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University Health System)
Lee, Moon-Hyoung (Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University Health System)
Kim, Sung-Soon (Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University Health System)
Joung, Bo-Young (Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University Health System)
Publication Information
Korean Circulation Journal / v.41, no.3, 2011 , pp. 164-166 More about this Journal
Abstract
A 46-year-old man presented to our institution with inappropriate implantable cardioverter-defibrillator (ICD) shock delivery. The ICD (single chamber, dual shock coils) was implanted for sustained monomorphic ventricular tachycardia with unstable hemodynamics and underlying systolic left ventricular dysfunction. ICD interrogation revealed recurrent episodes of ICD shock due to noise sensing and increased impedance of right ventricular-lead. With the impression of lead fracture, ICD lead extraction was performed. The fractured ICD lead was completely removed by traction of locking stylet and counter-traction of polypropylene dilator sheath. A new lead was inserted and the patient was discharged without complications after 2 days. To our knowledge, this is the first report on ICD lead extraction by conventional traction and counter-traction technique in Korea.
Keywords
Implantable cardioverter defibrillators; Medical device failure; Device removal;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
Times Cited By SCOPUS : 0
연도 인용수 순위
1 Kim DH, Kim SY, Lee KH, et al. Follow-up of a group of patients with automatic implantable defibrillator. Korean Circ J 2005;35:69-83.   DOI
2 Kim YH, Kim JS. Clinical characteristics in patients with implantable cardioverter-defibrillator (ICD). Korean Circ J 2004;34:395-404.   DOI
3 Smith HJ, Fearnot NE, Byrd CL, Wilkoff BL, Love CJ, Sellers TD. Five-years experience with intravascular lead extraction. U.S. Lead Extraction Database. Pacing Clin Electrophysiol 1994;17:2016-20.   DOI   ScienceOn
4 Byrd CL, Wilkoff BL, Love CJ, et al. Intravascular extraction of pro-blematic or infected permanent pacemaker leads: 1994-1996. U.S. Extraction Database, MED Institute. Pacing Clin Electrophysiol 1999; 22:1348-57.   DOI   ScienceOn
5 Becker AE, Becker MJ, Claudon DG, Edwards JE. Surface thrombosis and fibrous encapsulation of intravenous pacemaker catheter electro-de. Circulation 1972;46:409-12.   DOI   ScienceOn
6 Hauser RG, Katsiyiannis WT, Gornick CC, Almquist AK, Kallinen LM. Deaths and cardiovascular injuries due to device-assisted implan-table cardioverter-defibrillator and pacemaker lead extraction. Euro-pace 2010;12:395-401.
7 Molina JE. Undertreatment and overtreatment of patients with infect-ed antiarrhythmic implantable devices. Ann Thorac Surg 1997;63: 504-9.   DOI   ScienceOn
8 Eckart RE, Hruczkowski TW, Landzberg MJ, Ames A, Epstein LM. Pulmonary arterial embolization of pacemaker lead electrode tip. Pacing Clin Electrophysiol 2006;29:784-7.   DOI   ScienceOn
9 Bohm A, Banyai F, Komaromy K, Pinter A, Preda I. Cerebral embolism due to a retained pacemaker lead: a case report. Pacing Clin Elec-trophysiol 1998;21:629-30.   DOI   ScienceOn
10 Rosenheck S, Weiss A, Leibowitz D, Sharon Z. Noninstrumental pacemaker and defibrillator lead removal: the importance of the rotation forces. Pacing Clin Electrophysiol 2002;25:1029-36.   DOI   ScienceOn
11 Neuzil P, Taborsky M, Rezek Z, et al. Pacemaker and ICD lead extraction with electrosurgical dissection sheaths and standard transvenous extraction systems: results of a randomized trial. Europace 2007;9:98-104.   DOI   ScienceOn
12 Alt E, Neuzner J, Binner L, et al. Three-year experience with a stylet for lead extraction: a multicenter study. Pacing Clin Electrophysiol 1996;19:18-25.   DOI   ScienceOn
13 Klug D, Jarwe M, Messaoudene SA, et al. Pacemaker lead extraction with the needle's eye snare for countertraction via a femoral approach. Pacing Clin Electrophysiol 2002;25:1023-8.   DOI   ScienceOn
14 Byrd CL, Wilkoff BL, Love CJ, Sellers TD, Reiser C. Clinical study of the laser sheath for lead extraction: the total experience in the United States. Pacing Clin Electrophysiol 2002;25:804-8.   DOI   ScienceOn