Analysis of Potential Cost-Savings After Introduction of Drug-Eluting Balloon Angioplasty for In-Stent Restenosis or Small Vessel Disease |
Park, Kyung-Il
(Cardiovascular Center, Department of Internal Medicine, Seoul National University College of Medicine)
Kim, Tae-Eun (Cardiovascular Center, Department of Internal Medicine, Seoul National University College of Medicine) Park, Kyung-Woo (Cardiovascular Center, Department of Internal Medicine, Seoul National University College of Medicine) Kang, Hyun-Jae (Cardiovascular Center, Department of Internal Medicine, Seoul National University College of Medicine) Koo, Bon-Kwon (Cardiovascular Center, Department of Internal Medicine, Seoul National University College of Medicine) Kim, Hyo-Soo (Cardiovascular Center, Department of Internal Medicine, Seoul National University College of Medicine) |
1 | Stone GW, Ellis SG, Cannon L, et al. Comparison of a polymer-based paclitaxel-eluting stent with a bare metal stent in patients with complex coronary artery disease: a randomized controlled trial. JAMA 2005;294:1215-23. DOI ScienceOn |
2 | Iofina E, Haager PK, Radke PW, et al. Sirolimus- and paclitaxel-eluting stents in comparison with balloon angioplasty for treatment of instent restenosis. Catheter Cardiovasc Interv 2005;64:28-34. DOI ScienceOn |
3 | Kastrati A, Mehilli J, von Beckerath N, et al. Sirolimus-eluting stent or paclitaxel-eluting stent vs balloon angioplasty for prevention of recurrences in patients with coronary in-stent restenosis: a randomized controlled trial. JAMA 2005;293:165-71. DOI ScienceOn |
4 | Virmani R, Guagliumi G, Farb A, et al. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious? Circulation 2004;109:701-5. DOI ScienceOn |
5 | Posa A, Hemetsberger R, Petnehazy O, et al. Attainment of local drug delivery with paclitaxel-eluting balloon in porcine coronary arteries. Coron Artery Dis 2008;19:243-7. DOI ScienceOn |
6 | Cremers B, Speck U, Kaufels N, et al. Drug-eluting balloon: very short-term exposure and overlapping. Thromb Haemost 2009;101:201-6. |
7 | Unverdorben M, Vallbracht C, Cremers B, et al. Paclitaxel-coated balloon catheter versus paclitaxel-coated stent for the treatment of coronary in-stent restenosis. Circulation 2009;119:2986-94. DOI ScienceOn |
8 | Hong SJ, Ahn TH, Kim MH, et al. Comparison of the predictors of cronary restenosis after drug-eluting stent implantation in diabetic and nondiabetic patients. Korean Circ J 2007;37:530-7. DOI ScienceOn |
9 | Elezi S, Kastrati A, Neumann FJ, Hadamitzky M, Dirschinger J, Schomig A. Vessel size and long-term outcome after coronary stent placement. Circulation 1998;98:1875-80. DOI ScienceOn |
10 | Unverdorben M, Kleber FX, Heuer H, et al. Treatment of small coronary arteries with a paclitaxel-coated balloon catheter. Clin Res Cardiol 2010;99:165-74. DOI ScienceOn |
11 | Scheller B, Hehrlein C, Bocksch W, et al. Two year follow-up after treatment of coronary in-stent restenosis with a paclitaxel-coated balloon catheter. Clin Res Cardiol 2008;97:773-81. DOI ScienceOn |
12 | Bauters C, Hubert E, Prat A, et al. Predictors of restenosis after coronary stent implantation. J Am Coll Cardiol 1998;31:1291-8. DOI ScienceOn |
13 | Novack V, Nguyen MC, Rooney M, et al. Effect of coronary target lesion revascularization on late cardiac events after insertion of sirolimus-eluting or bare metal stents. Am J Cardiol 2010;106:774-9. DOI ScienceOn |
14 | Lee CW, Park SJ. Predictive factors for restenosis after drug-eluting stent implantation. Korean Circ J 2007;37:97-102. DOI ScienceOn |
15 | Scheller B, Speck U, Abramjuk C, Bernhardt U, Bohm M, Nickenig G. Paclitaxel balloon coating, a novel method for prevention and therapy of restenosis. Circulation 2004;110:810-4. DOI ScienceOn |
16 | Scheller B, Speck U, Romeike B, et al. Contrast media as carriers for local drug delivery: successful inhibition of neointimal proliferation in the porcine coronary stent model. Eur Heart J 2003;24:1462-7. DOI ScienceOn |
17 | Scheller B, Hehrlein C, Bocksch W, et al. Treatment of coronary instent restenosis with a paclitaxel-coated balloon catheter. N Engl J Med 2006;355:2113-24. DOI ScienceOn |
18 | Kuntz RE, Safian RD, Carrozza JP, Fishman RF, Mansour M, Baim DS. The importance of acute luminal diameter in determining restenosis after coronary atherectomy or stenting. Circulation 1992;86:1827-35. DOI ScienceOn |
19 | Savage MP, Fischman DL, Rake R, et al. Efficacy of coronary stenting versus balloon angioplasty in small coronary arteries: Stent Restenosis Study (STRESS) Investigators. J Am Coll Cardiol 1998;31:307-11. DOI |
20 | Ardissino D, Cavallini C, Bramucci E, et al. Sirolimus-eluting vs uncoated stents for prevention of restenosis in small coronary arteries: a randomized trial. JAMA 2004;292:2727-34. DOI ScienceOn |
21 | Whang YJ, Kim HS, Kim KM, et al. The efficacy of drug eluting stents on restenosis reduction in small coronary arteries. Korean Circ J 2006;36:450-7. |
22 | Cortese B, Micheli A, Picchi A, Coppolaro A, et al. Paclitaxel-coated balloon versus drug-eluting stent during PCI of small coronary vessels, a prospective randomised clinical trial: the PICCOLETO Study. Heart 2010;96:1291-6. DOI ScienceOn |
![]() |