Clinical Implications of Ambulatory and Home Blood Pressure Monitoring  

Kim, Soon-Gil (Division of Cardiology, Guri Hospital, Hanyang University College of Medicine)
Publication Information
Korean Circulation Journal / v.40, no.9, 2010 , pp. 423-431 More about this Journal
Abstract
Because blood pressure (BP) is an ever changing hemodynamic phenomenon, a BP value, once measured at a physician's office (Office BP), is often unrepresentative of an individual's true BP status. Both ambulatory blood pressure monitoring (ABPM) and home blood pressure monitoring (HBPM) provide more accurate and reproducible estimate of BP, and produce stronger predictive ability for cardiovascular outcome than conventional office BP. Two BP measuring techniques, ABPM and HBPM have been widely in clinical use for the detection and management of hypertension. However, they have different advantages and limitations in practice. At present, it has become crucial to understand the characteristics and clinical implications of these BP measuring techniques for those responsible for the care of hypertensive patients.
Keywords
Hypertension; Blood pressure monitoring;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
Times Cited By SCOPUS : 0
연도 인용수 순위
1 Parati G, Stergiou GS, Asmar R, et al. European Society of Hypertension guidelines for blood pressure monitoring at home: a summary report of the Second International Consensus Conference on Home Blood Pressure Monitoring. J Hypertens 2008;26:1505-26.   DOI   ScienceOn
2 Staessen JA, Thijs L, Fagard R, et al. Predicting cardiovascular risk us-ing conventional vs ambulatory blood pressure in older patients with systolic hypertension. JAMA 1999;282:539-46.   DOI   ScienceOn
3 Vaur L, Duborca I, Dutrey-Dupagne C, et al. Superiority of home blood pressure measurements over office measurements for testing antihypertensive drugs. Blood Press Monit 1998;3:107-14.
4 Staessen JA, Den HE, Celis H, et al. Antihypertensive treatment based on blood pressure measurement at home or in the physician's office: a randomized controlled trial. JAMA 2004;291:955-64.   DOI   ScienceOn
5 Cappuccio FP, Kerry SM, Forbes L, Donald A. Blood pressure control by home monitoring: meta-analysis of randomized trials. BMJ 2004;329:145.   DOI   ScienceOn
6 Eguchi K, Ishikawa J, Hoshide S, Pickering TG, Shimada K, Kario K. Masked hypertension in diabetes mellitus: a potential risk. J Clin Hypertens (Greenwich) 2007;9:601-7.   DOI
7 Redon J, Liano Y, Lozano JV, Miralles A, Pascual JM, Cooper RS. Ambulatory blood pressure and microalbuminuria in essential hypertension: role of circadian variability. J Hypertens 1994;12:947-53.
8 Ohkubo T, Imai Y, Tsuji I, et al. Relation between nocturnal decline in blood pressure and mortality: the Ohasama study. Am J Hypertens 1997;10:1201-7.   DOI   ScienceOn
9 Bjorklund K, Lind L, Zethelius B, Berglund L, Lithell H. Prognostic significance of 24-h ambulatory blood pressure characteristics for cardiovascular morbidity in a population of elderly men. J Hypertens 2004;22:1691-7.   DOI   ScienceOn
10 Agarwal R, Andersen MJ. Blood pressure recordings within and outside the clinic and cardiovascular events in chronic kidney disease. Am J Nephrol 2006;26:503-10.   DOI   ScienceOn
11 Lee CK, Her GM, Park GE, et al. Interrelationship between left ventricular mass and diurnal variations of blood pressure in patients with essential hypertension. Korean Circ J 1997;27:13-9.   DOI
12 Verdecchia P, Schillaci G, Guerrieri M, et al. Circadian blood pressure changes and left ventricular hypertrophy in essential hypertension. Circulation 1990;81:528-36.   DOI   ScienceOn
13 Kim SJ, Kang HS, Hwang SJ, et al. The relation of circadian blood pre-ssure variation to left ventricular mass, diastolic function and dynamic QT dispersion. Korean Circ J 2005;35:382-8.   DOI
14 Lee JU, Kim KS, Kim SK, et al. Left ventricular geometric patterns of dippers and non-dippers in essential hypertension. Korean Circ J 1996; 26:44-51.   DOI
15 Kikuya M, Hansen TW, Thijs L, et al. Diagnostic thresholds for ambulatory blood pressure monitoring based on 10-year cardiovascular risk. Blood Press Monit 2007;12:393-5.   DOI   ScienceOn
16 Rave K, Bender R, Heise T, Sawicki PT. Value of blood pressure self-monitoring as a predictor of progression of diabetic nephropathy. J Hypertens 1999;17:597-601.   DOI   ScienceOn
17 Lurbe E, Invitti C, Torro I, et al. The impact of the degree of obesity on the discrepancies between office and ambulatory blood pressure values in youth. J Hypertens 2006;24:1557-64.   DOI   ScienceOn
18 Milne F, Redman C, Walker J, et al. The preeclampsia community guideline (PRECOG): how to screen for and detect onset of preeclampsia in the community. BMJ 2005;330:576-80.   DOI   ScienceOn
19 Shimada K, Kawamoto A, Matsubayashi K, et al. Diurnal blood pressure variations and silent cerebrovascular damage in elderly patients with hypertension. J Hypertens 1992;10:875-8.
20 Hansen TW, Kikuya M, Thijs L, et al. Diagnostic thresholds for ambulatory blood pressure moving lower: a review based on a meta-analysis- clinical implications. J Clin Hypertens 2008;10:377-81.   DOI   ScienceOn
21 O'Brien E, Sheridan J, O'Malley K. Dipper and non-dippers. Lancet 1988;2:397.
22 Verdecchia P. Prognostic value of ambulatory blood pressure: current evidence and clinical implications. Hypertension 2000;35:844-51.   DOI   ScienceOn
23 Kikuya M, Hansen TW, Thijs L, et al. Diagnostic thresholds for ambulatory blood pressure monitoring based on 10-year cardiovascular risk. Circulation 2007;115:2145-52.   DOI   ScienceOn
24 Redon J, Oliver V, Zaragoza MD, Galindo MJ. Ambulatory blood pressure during diseases of the kidney. Blood Press Monit 1999;4:267-74.
25 Mengden T, Hemandez Medina RM, Beltran B, Alvarez E, Kraft K, Vetter H. Reliability of reporting self-measured blood pressure values by hypertensive patients. Am J Hypertens 1998;11:1413-7.   DOI   ScienceOn
26 Staessen JA, Gasowski J, Wang JG, et al. Risks of untreated and treated isolated systolic hypertension in the elderly: meta-analysis of outcome trials. Lancet 2000;355:865-72.   DOI   ScienceOn
27 Dolan E, Stanton A, Thijs L, et al. Superiority of ambulatory over clinical blood pressure measurement in predicting mortality: the Dublin outcome study. Hypertension 2005;46:156-61.   DOI   ScienceOn
28 Staessen JA, Fagard R, Thijs L, et al. Randomised double-blind comparison of placebo and active treatment for older patients with isolated systolic hypertension. Lancet 1997;350:757-64.   DOI
29 Bobrie G, Chatellier G, Genes N, et al. Cardiovascular prognosis of 'masked hypertension' detected by blood pressure self-measurement in elderly treated hypertensive patients. JAMA 2004;291:1342-9.   DOI   ScienceOn
30 Pickering TG, Hall JE, Appel LJ, et al. Recommendations for blood pressure measurement in humans and experimental animals: part I. blood pressure measurement in humans. A statement for professionals from the sub-committee of professional and public education of the American Heart Association council on high blood pressure research. Hypertension 2005;45:142-61.   DOI
31 Clement DL, Buyzere ML, De Bacquer DA, et al. Prognostic value of ambulatory blood pressure recordings in patients with treated hypertension. N Engl J Med 2003;348:2407-15.   DOI   ScienceOn
32 Bjorklund K, Lind L, Zethelius B, Andren B, Lithell H. Isolated ambulatory hypertension predicts cardiovascular morbidity in elderly men. Circulation 2003;107:1297-302.   DOI   ScienceOn
33 Pierdomenico SD, Lapenna D, Bucci A, et al. Cardiovascular and renal events in uncomplicated mild hypertensive patients with sustained and white coat hypertension. Am J Hypertens 2004;17:876-81.   DOI   ScienceOn
34 Hansen TW, Jeppesen J, Rasmussen S, Ibsen H, Torp-Pedersen C. Ambulatory blood pressure and mortality: a population-based study. Hypertension 2005;45:499-504.   DOI   ScienceOn
35 Ogedegbe G, Schoenthaler A. A systematic review of the effects of home blood pressure monitoring on medication adherence. J Clin Hypertens (Greenwich) 2006;8:174-80.   DOI   ScienceOn
36 Logan AG, Dunai A, McIssac WJ, Irvine MJ, Tisler A. Attitudes of primary care physicians and their patients about home blood pressure monitoring in Ontario. J Hypertens 2008;26:446-52.   DOI   ScienceOn
37 Ohkubo T, Asayama K, Kikuya M, et al. Prediction of ischaemic and heamorrhagic stroke by self-measured blood pressure at home: the Oh-asama study. Blood Press Monit 2004;9:315-20.   DOI   ScienceOn
38 Fagard RH, Van den Broeke C, De Cort P. Prognostic significance of blood pressure measured in office, at home and during ambulatory mo-nitoring in older patients in general practice. J Hum Hypertens 2005; 19:801-7.   DOI   ScienceOn
39 Sega R, Facchetti R, Bombelli M, et al. Prognostic value of ambulatory and home blood pressures compared with office blood pressure in the general population: follow-up results from Pressioni Arteriose Mo-nitorate e Loro Associozioni (PAMELA) Study. Circulation 2005;111:1777-83.   DOI   ScienceOn
40 Kario K, Shimata K, Schwartz JE, Matsuo T, Hoshide S, Pickering TG. Silent and clinically overt stroke in older Japanese subjects with white-coat and sustained hypertension. J Am Coll Cardiol 2001;38:238-45.   DOI   ScienceOn
41 Verdecchia P, Porcellati C, Schillaci G, et al. Ambulatory blood pressure: an independent predictor of prognosis in essential hypertension. Hypertension 1994;24:793-801.   DOI   ScienceOn
42 Stergiou GS, Zourbaki AS, Skeba II, Mountokalakis TD. White coat effect detecting using self-monitoring of blood pressure at home: comparison with ambulatory blood pressure. Am J Hypertens 1998;11:820-7.   DOI   ScienceOn
43 Denolle T, Waeber B, Kjeldsen S, Parati G, Wilson M, Asmar R. Self-measurement of blood pressure in clinical trials and therapeutic applications. Blood Press Monit 2000;5:145-9.
44 Mancia G, Facchetti R, Bombelli M, Grassi G, Sega R. Long-term risk of mortality associated with selective and combined elevation in office, home, and ambulatory blood pressure. Hypertension 2006;47:846-53.   DOI   ScienceOn
45 Gustavsen PH, Hoegholm A, Bang LE, Kristensen KS. White coat hypertension is a cardiovascular risk facter: a 10-year follow-up study. J Hum Hypertens 2003;17:811-7.   DOI   ScienceOn
46 Perloff D, Sokolow M, Cowan R. The prognostic value of ambulatory blood pressure. JAMA 1983;249:2792-8.   DOI   ScienceOn
47 Redon J, Campos C, Narciso ML, Rodicio JL, Pascual JM, Ruilope LM. Prognostic value of ambulatory blood pressure monitoring in refractory hypertension: a prospective study. Hypertension 1998;31: 712-8.   DOI   ScienceOn
48 Ohkubo T, Imai Y, Tsuji I, et al. Home blood pressure measurement has a stronger predictive power for mortality than does screening blood pressure measurement: a population-based observation in Ohasama, Japan. J Hypertens 1998;16:971-5.   DOI   ScienceOn
49 Pickering T, Davidson K, Gerin W, Schwartz JE. Masked hypertension. Hypertension 2002;40:795-6.   DOI   ScienceOn
50 Ohkubo T, Imai Y, Tsuji I, et al. Prediction of mortality by ambulatory blood pressure monitoring versus screening blood pressure measurements: a pilot study in Ohasama. J Hypertens 1997;15:357-64.   DOI   ScienceOn
51 Khattar RS, Senior R, Lahiri A. Cardiovascular outcome in white-coat versus sustained mild hypertension: a 10 year follow-up study. Circulation 1998;98:1892-7.   DOI   ScienceOn
52 Ohkubo T, Kikuya M, Metoki H, et al. Prognosis of "masked" hypertension and "white-coat" hytertension detected by 24-h ambulatory blood pressure monitoring 10-year follow-up from the Ohasama study. J Am Coll Cardiol 2005;46:508-15.   DOI   ScienceOn
53 Pierdomenico SD, Lapenna D, Bucci A, et al. Cardiovascular outcome in treated hypertensive patients with responder, false resistant, and true resistant hypertension. Am J Hypertens 2005;18:1422-8.   DOI   ScienceOn
54 Verberk WJ, Kroon AA, Kessels AG, de Leeuw PW. Home blood pressure measurement: a systemic review. J Am Coll Cardiol 2005;46:743-51.   DOI   ScienceOn
55 Mengden T, Chamontin B, Phong CN, Luis Palma GJ, Chanudet X. User procedure for self-measurement of blood pressure. First International Consensus Conference on Self Blood Pressure Measurement. Blood Press Monit 2000;5:111-29.
56 Verdecchia P, Angeli F, Mazzotta G, Gentile G, Reboldi G. Home blood pressure measurement will not replace 24-hour ambulatory blood pressure measurement. Hypertension 2009. [Epub ahead of print]
57 Parati G, Omboni S, Bilo G. Why is out-of-office blood pressure measurement needed?: home blood pressure measurements will increasingly replace ambulatory blood pressure monitoring in the diagnosis and management of hypertension. Hypertension 2009. [Epub ahead of print]
58 Verdecchia P, Reboldi GP, Angeli F, et al. Short- and long-term incidence of stroke in white-coat hypertension. Hypertension 2005;45:203-8.   DOI   ScienceOn
59 Ugajin T, Hozawa A, Ohkubo T, et al. White-coat hypertension as a risk factor for the development of home hypertension: the Ohasama study. Arch Intern Med 2005;165:1541-6.   DOI   ScienceOn
60 Park IS, Rho TH, Park JW, et al. Prevalence of urinary microalbuminuria in normal and hypertensive Koreans and its correlation with blood pressure measured by 24 hours ambulatory blood pressure monitoring. Korean Circ J 1994;24:834-40.   DOI
61 Jeon HC, Kim YK, Kim KY, et al. Determination of left ventricular mass in healthy adults: a study using echocardiography and 24 hour ambulatory blood pressure monitoring. Korean Circ J 1995;25:811-9.   DOI
62 Pickering TG, Shimbo D, Hass D. Ambulatory blood-pressure monitoring. N Engl J Med 2006;354:2368-74.
63 Rim SJ. Blood pressure variation and cardiovascular risks. Korean Circ J 2008;38:131-4.   DOI   ScienceOn
64 Kim HY, Kwack NJ, Park NK, et al. Influences of white-coat hypertension and white-coat effect on the left ventricular mass and diastolic function. Korean Circ J 1995;25:987-97.   DOI
65 Kim JH, Park JC. Variables and end-points in Korean Ambulatory Bl-ood Pressure (Kor-ABP) registry. J Korean Soc Hypertens 2009;15 (Suppl I):I74-80.
66 Metoki H, Ohkubo T, Kikuya M, et al. Prognostic significance for st-roke of a morning pressure surge and a nocturnal blood pressure decline: the Ohasama study. Hypertension 2006;47:149-54.   DOI
67 Ohkubo T, Metoki H, Imai Y. Prognostic significance of morning sur-ge in blood pressure: which definition, which outcome? Blood Press Monit 2008;13:161-2.   DOI   ScienceOn
68 Yoo WS, Park HJ, Lee EY, Choi SK. A representative value for 24-h ambulatory blood pressure monitoring. Korean Circ J 1985;15:209-14.   DOI
69 Boggia J, Li Y, Thijs L, et al. Prognositic accuracy of day versus night ambulatory blood pressure: a cohort study. Lancet 2007;370:1219-29.   DOI   ScienceOn
70 Kikuya M, Hozowa A, Ohkubo T, et al. Prognostic significance of blood pressure and heart rate variabilities: the Ohasama study. Hypertension 2000;36:901-6.   DOI   ScienceOn
71 Verdecchia P, Borgioni C, Ciucci A, et al. Prognostic significance of blood pressure variability in essential hypertension. Blood Press Monit 1996;1:3-11.
72 Kario K, Pickering TG, Umeda Y, et al. Morning surge in blood pressure as a predictor of silent and clinical cerebrovascular disease in elderly hypertensives: a prospective study. Circulation 2003;107:1401-6.   DOI   ScienceOn
73 O'Brien E, Asmar R, Beilin L, et al. European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurement. J Hypertens 2003;21:821-48.   DOI   ScienceOn