Browse > Article
http://dx.doi.org/10.12989/eas.2021.20.5.495

Multiple performance criteria-based risk assessment for structures equipped with MR dampers  

Mohebbi, Mohtasham (Faculty of Engineering, University of Mohaghegh Ardabili)
Bakhshinezhad, Sina (Faculty of Engineering, University of Mohaghegh Ardabili)
Publication Information
Earthquakes and Structures / v.20, no.5, 2021 , pp. 495-512 More about this Journal
Abstract
In this paper, a procedure to seismic risk assessment of structures equipped with magnetorheological (MR) damper considering multiple performance criteria has been presented while accounting for uncertainties of the applied excitation, structure and damper properties, and damage state thresholds. The procedure employes the Latin hypercube sampling (LHS) method to generate 30 sample random MR-Structure systems and incremental dynamic analysis (IDA) has been conducted under 20 earthquakes to evaluate engineering demand parameters. Fragilities have been evaluated using the Monte Carlo simulation (MCS) method in each intensity measure and have been integrated with the hazard curve to determine the reliability during lifetime. For numerical analysis, an eight-story nonlinear shear building with bilinear hysteresis behavior has been adopted. The effectiveness of the introduced methodology is illustrated through a seismic risk assessment of the structure equipped with passive-off and passive-on MR dampers. Numerical results have shown the capability of MR dampers in significant mitigation of the seismic risk of the nonlinear structure. Moreover, it is observed that considering multiple performance criteria of the structural system, non-structural components, and MR damper stroke length and the interaction between them has led to increase the seismic risk. Also, the uncertainty of the applied excitation shows more remarkable influence with respect to the other sources of uncertainties.
Keywords
risk assessment; fragility curves; reliability during lifetime; multiple performance criteria; nonlinear structure; MR damper uncertainty; MR damper damage state;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Guo, A.X., Xu, Y.L. and Wu, B. (2002), "Seismic reliability analysis of hysteretic structure with viscoelastic dampers", Eng. Struct., 24(3), 373-83. https://doi.org/10.1016/S0141-0296(01)00103-1.   DOI
2 Hadidi, A., Azar, B.F. and Shirgir, S. (2019), "Reliability assessment of semi-active control of structures with MR damper", Earthq. Struct., 17(2), 131-141. https://doi.org/10.12989/eas.2019.17.2.131.   DOI
3 Hazus-MH. (2003), "Hazus-MH 2.1, Technical Manual, Multihazard Loss Estimation Methodology", FEMA.
4 Iervolino, I. and Cornell, C.A. (2005), "Record selection for nonlinear seismic analysis of structures", Earthq. Spec., 21(3), 685-713. https://doi.org/10.1193/1.1990199.   DOI
5 Izzuddin, B.A., Karayannis, C.G. and Elnashai, A.S. (1994) "Advanced nonlinear formulation for reinforced concrete beamcolumns", J. Struct. Eng., 120(10), 2913-2934. https://doi.org/10.1061/(ASCE)0733-9445(1994)120:10(2913).   DOI
6 Jalayer, F. and Cornell, C.A. (2009), "Alternative non-linear demand estimation methods for probability-based seismic assessments", Earthq. Eng. Struct. Dyn., 38(8), 951-972. https://doi.org/10.1002/eqe.876.   DOI
7 Kataria, N.P. and Jangid, R.S. (2014), "Optimum semi-active hybrid system for seismic control of the horizontally curved bridge with Magnetorheological damper", Bridge Struct., 10(4), 145-160. https://doi.org/10.3233/BRS-150083.   DOI
8 Mansouri, I., Soori, S., Amraie, H., Hu, J.W. and Shahbazi, S. (2018), "Performance based design optimum of CBFs using bee colony algorithm" Steel Compos. Struct., 27(5), 613-622. https://doi.org/10.12989/scs.2018.27.5.613.   DOI
9 McKay, M.D., Beckman, R.J. and Conover, W.J. (1979), "A Comparison of three methods for selecting values of input variables in the analysis of output from a computer code", Technometrics, 21(2), 239-245. https://doi.org/10.2307/1268522.   DOI
10 Mohammadi, R.K. and Sharghi, A.H. (2014), "On the optimum performance-based design of eccentrically braced frames" Steel Compos. Struct., 16(4), 357-374. https://doi.org/10.12989/scs.2014.16.4.357.   DOI
11 Nowak, A.S. and Collins, K.R. (2000), "Reliability of Structures", 2nd Edition, McGraw-Hill.
12 Ellingwood, B., Galambos, T.V., MacGregor, J.G. and Cornell, C.A. (1980), "Development of a probability-based load criterion for American national standard A58", National Bureau of Standards, Washington, DC.
13 Cimellaro, G.P. and Reinhorn, A.M. (2011), "Multidimensional performance limit state for hazard fragility functions", J. Eng. Mech., 137(1), 47-60. https://doi.org/10.1061/(ASCE)EM.1943-7889.0000201.   DOI
14 Dall'Asta, A., Scozzese, F., Ragni, L. and Tubaldi, E. (2017), "Effect of the damper property variability on the seismic reliability of linear systems equipped with viscous dampers", B. Earthq. Eng., 15(11), 5025-5053. https://doi.org/10.1007/s10518-017-0169-8.   DOI
15 Dolsek, M. (2009), "Incremental dynamic analysis with consideration of modeling uncertainties", Earthq. Eng. Struct. Dyn., 38(6), 805-825. https://doi.org/10.1002/eqe.869.   DOI
16 Wong, K.K.F. and Harris, J.L. (2012), "Seismic damage and fragility analysis of structures with tuned mass dampers based on plastic energy", Struct. Des. Tall Spec., 21(4), 296-310. https://doi.org/10.1002/tal.604.   DOI
17 Izzuddin, B.A. (1991) "Nonlinear Dynamic Analysis of Framed Structures", Ph.D. Dissertation, Department of Civil Engineering, Imperial College, University of London.
18 Ghaffari, A. and Mohammadi, R.K. (2019), "Comprehensive nonlinear seismic performance assessment of MR damper controlled system using virtual real-time hybrid simulation", Struct. Des. Tall Spec. Buildings, 28(8), e1606. https://doi.org/10.1002/tal.1606.   DOI
19 Vamvatsikos, D. and Cornell, CA. (2002), "Incremental Dynamic Analysis", Earthq. Eng. Struct. Dyn., 31(3), 491-514. https://doi.org/10.1002/eqe.141.   DOI
20 Yang, G.N., Long, F.X. and Wong D. (1988) "Optmial control of nonlinear flexible structures", Technical Report, NCEER.
21 Kaveh, A., Fahimi-Farzam, M. and Kalateh-Ahani, M. (2015), "Optimum design of steel frame structures considering construction cost and seismic damage" Smart Struct. Syst., 16(1), 1-26. https://doi.org/10.12989/sss.2015.16.1.001.   DOI
22 Cha, Y.J. and Bai, J.W. (2016), "Seismic fragility estimates of a moment-resisting frame building controlled by MR dampers using performance-based design", Eng. Struct., 116, 192-202. https://doi.org/10.1016/j.engstruct.2016.02.055.   DOI
23 Sues, R.K., Wen, Y.K. and Ang, A.H.S. (1985), "Stochastic evaluation of seismic structural performance", ASCE J. Struct. Eng., 111(6), 1204-1218. https://doi.org/10.1061/(ASCE)0733-9445(1985)111:6(1204).   DOI
24 Tubaldi, E., Barbato, M. and Dall'Asta, A. (2014), "Performancebased seismic risk assessment for buildings equipped with linear and nonlinear viscous dampers", Eng. Struct., 78, 90-99. https://doi.org/10.1016/j.engstruct.2014.04.052.   DOI
25 Jalayer, F., Ebrahimian, H., Miano, A., Manfredi, G. and Sezen, H. (2017), "Analytical fragility assessment using unscaled ground motion records", Earthq. Eng. Struct. Dyn., 46(15), 2639-2663. https://doi.org/10.1002/eqe.2922.   DOI
26 Shu, Z., Li, S., Sun, X. and He, M. (2019), "Performance-based seismic design of a pendulum tuned mass damper system", J. Earthq. Eng., 23(2), 334-355. https://doi.org/10.1080/13632469.2017.1323042.   DOI
27 Wilbee, A.K., Pena, F., Condori, J., Sun, Z. and Dyke, S.J. (2015), "Fragility analysis of structures incorporating control systems", 6th International Conference on Advances in Experimental Structural Engineering, University of Illinois, United States of America.
28 Yang, M.G., Cheng, Z.Q. and Hua, X.G. (2011), "An experimental study on using MR damper to mitigate longitudinal seismic response of a suspension bridge", Soil Dyn. Earthq. Eng., 31(8), 1171-1181. https://doi.org/10.1016/j.soildyn.2011.04.006.   DOI
29 Jung, H.J., Spencer, Jr.B.F. and Lee, I.W. (2003), "Control of seismically excited cable-stayed bridge employing magnetorheological fluid dampers", J Struct. Eng., 129(7), 873-883. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:7(873).   DOI
30 Karayannis, C.G., Izzuddin, B.A. and Elnashai, A.S. (1994) "Application of adaptive analysis to reinforced concrete frames", J. Struct. Eng., 120(10), 2935-2957. https://doi.org/10.1061/(ASCE)0733-9445(1994)120:10(2935).   DOI
31 Newmark, N.M. (1959), "A method of computing for structural dynamics", J. Eng. Mech., 85(3), 67-94.
32 Oliveira, F., Botto, M.A., Morais, P. and Suleman, A. (2018), "Semi-active structural vibration control of base-isolated buildings using magnetorheological dampers", J. Low Freq. Noise V. A., 37(3), 565-576. https://doi.org/10.1177/1461348417725959.   DOI
33 Porter, K.A., Beck, J.L. and Shaikhutdinov, R.V. (2002), "Investigation of sensitivity of building loss estimates to major uncertain variables for the Van Nuys testbed", PEER Report, University of California, Berkley.
34 Scozzese, F., Dall'Asta, A. and Tubaldi, E. (2019), "Seismic risk sensitivity of structures equipped with anti-seismic devices with uncertain properties", Struct. Saf., 77, 30-47. https://doi.org/10.1016/j.strusafe.2018.10.003.   DOI
35 Fu, W., Zhang, C., Li, M. and Duan, C. (2019), "Experimental investigation on semi-active control of base isolation system using magnetorheological dampers for concrete frame structure", Appl. Sci., 9(18), 3866. https://doi.org/10.3390/app9183866.   DOI
36 Favvata, M.J., Naoum, M.C. and Karayannis, C.G. (2013), "Limit states of RC structures with first floor irregularities", Struct. Eng. Mech., 47(6), 791-818. https://doi.org/10.12989/sem.2013.47.6.791.   DOI
37 FEMA-355. (2000), "State of the art report on systems performance of steel moment frames subjected to earthquake ground shaking", The SAC joint venture for the Federal Emergency Management Agency, Washington, DC.
38 Field, E.H., Jordan, T.H. and Cornell, C.A. (2003), "OpenSHA: a developing community-modeling environment for seismic hazard analysis", Seismol. Res. Lett., 74(4), 406-419. https://doi.org/10.1785/gssrl.74.4.406.   DOI
39 De Risi, R., Goda, K. and Tesfamariam, S. (2019), "Multidimensional damage measure for seismic reliability analysis", Struct. Saf., 78, 1-11. https://doi.org/10.1016/j.strusafe.2018.12.002.   DOI
40 ASCE/SEI 7-16. (2017), "Minimum design loads and associated criteria for buildings and other structures", https://doi.org/10.1061/9780784414248.
41 Radu, A., Lazar, I.F. and Neild, S.A. (2019), "Performance-based seismic design of tuned inerter dampers", Struct. Control Health Monit., 26(5), e2346. https://doi.org/10.1002/stc.2346.   DOI
42 Shoaei, P., Orimi, H.T. and Zahrai, S.M. (2018), "Seismic reliability-based design of inelastic base-isolated structures with lead-rubber bearing systems", Soil Dyn. Earthq. Eng., 115, 589-605. https://doi.org/10.1016/j.soildyn.2018.09.033.   DOI
43 Kohrangi, M., Bazzurro, P. and Vamvatsikos, D. (2016), "Vector and scalar IMs in structural response estimation, part I: hazard analysis", Earthq. Spec., 32(3), 1507-1524. https://doi.org/10.1193/053115EQS080M.   DOI
44 Lu, Z., Li, K., Ouyang, Y. and Shan, J. (2018), "Performance-based optimal design of tuned impact damper for seismically excited nonlinear building", Eng. Struct., 160, 314-327. https://doi.org/10.1016/j.engstruct.2018.01.042.   DOI
45 Shan, J., Ouyang, Y., Yuan, H. and Shi, W. (2016), "Seismic datadriven identification of linear models for building structures using performance and stabilizing objectives", Comput-Aided Civ. Inf., 31(11), 846-870. https://doi.org/10.1111/mice.12227.   DOI
46 El-Khoury, O., Kim, C., Shafieezadeh, A., Hur, J.E., Heo, G.H. (2018), "Mitigation of the seismic response of multi-span bridges using MR dampers: Experimental study of a new SMCbased controller", J. Sound Vib., 24(1), 83-99. https://doi.org/10.1177/1077546316633540.   DOI
47 Kim, Y. and Bai, J.W. (2017), "Seismic fragility analysis of faulty smart structures", In book: Computational Methods in Earthquake Engineering. https://doi.org/10.1007/978-3-319-47798-5_11.
48 Kaveh, A., Kalateh-Ahani, M. and Fahimi-Farzam, M. (2014), "Life-cycle cost optimization of steel moment-frame structures: performance-based seismic design approach", Earthq. Struct., 7(3), 271-294. https://doi.org/10.12989/eas.2014.7.3.271.   DOI
49 Karayannis, C.G., Favvata, M.J. and Kakaletsis, D.J. (2011), "Seismic behaviour of infilled and pilotis RC frame structures with beam-column joint degradation effect" Eng. Struct., 33(10), 2821-2831. https://doi.org/10.1016/j.engstruct.2011.06.006.   DOI
50 ASCE/SEI 41-17. (2017), "Seismic evaluation and retrofit rehabilitation of existing buildings", https://doi.org/10.1061/9780784414859.
51 Kazantzi, A.K., Vamvatsikos, D. and Lignos D.G. (2014), "Seismic performance of a steel moment-resisting frame subjected to strength and ductility uncertainty", Eng. Struct., 78, 69-77. https://doi.org/10.1016/j.engstruct.2014.06.044.   DOI
52 Kim, Y., Bai, J.W. and Albano, L.D. (2013), "Fragility estimates of smart structures with sensor faults", Smart Mater. Struct., 22(12), 125012. https://doi.org/10.1088/0964-1726/22/12/125012.   DOI
53 Kiureghian, A.D. (2005), "Non-ergodicity and PEER's framework formula", Earthq. Eng. Struct. Dyn., 34(13), 1643-1652. https://doi.org/10.1002/eqe.504.   DOI
54 Sfahani, M.G., Guan, H. and Loo, Y.C. (2015), "Seismic reliability and risk assessment of structures based on fragility analysis - a review", Adv. Struct. Eng., 18(10), 1653-1669. https://doi.org/10.1260/1369-4332.18.10.1653.   DOI
55 Dyke, S.J., Spencer Jr, B.F., Sain, M.K. and Carlson, J.D. (1996), "Modeling and control of magnetorheological dampers for seismic response reduction", Smart Mater. Struct., 5(5), 565-575. https://doi.org/10.1088/0964-1726/5/5/006.   DOI
56 Li, S., Tian, J. and Liu, Y. (2017), "Performance-based seismic design of eccentrically braced steel frames using target drift and failure mode" Earthq. Struct., 13(5), 443-454. https://doi.org/10.12989/eas.2017.13.5.443.   DOI
57 Joghataie, A. and Mohebbi, M. (2012), "Optimal control of nonlinear frames by Newmark and distributed genetic algorithm", Struct. Des. Tall Spec. Buildings, 21(2), 77-95. https://doi.org/10.1002/tal.576.   DOI
58 Alqado, T.E. and Nikolakopoulos, G. (2016), "Posicast control of structures using MR dampers", Struct. Control Health Monit., 23(8), 1121-1134. https://doi.org/10.1002/stc.1832.   DOI
59 Altieri, D., Tubaldi, E., De Angelis, M., Patelli, E. and Dall'Asta, A. (2018), "Reliability-based optimal design of nonlinear viscous dampers for the seismic protection of structural systems", B. Earthq. Eng., 16(2), 963-982. https://doi.org/10.1007/s10518-017-0233-4.   DOI
60 ASCE/SEI 7-10. (2010), "Minimum design loads for buildings and other structures", https://doi.org/10.1061/9780784412916.
61 Bakhshinezhad, S. and Mohebbi, M. (2020), "Multi-objective optimal design of semi-active fluid viscous dampers for nonlinear structures using NSGA-II", Struct., 24, 463-475. https://doi.org/10.1016/j.istruc.2020.02.004.   DOI
62 Barnawi, W.T. (2008), "Seismic fragility relationships for civil structures retrofitted with semi-active devices", Master's thesis, Washington University, Missouri, United States of America.
63 Barnawi, W.T. and Dyke, S.J. (2014), "Seismic fragility relationships of a cable-stayed bridge equipped with response modification systems", J. Bridge Eng., 19(8), A4013003. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000468.   DOI
64 Bakhshinezhad, S. and Mohebbi, M. (2019b), "Fragility curves for structures equipped with optimal SATMDs" Int. J. Optim. Civil. Eng., 9(3), 437-455.
65 Cardone, D., Perrone, G. and Piesco, V. (2019), "Developing collapse fragility curves for base-isolated buildings", Earthq. Eng. Struct. Dyn., 48(1), 78-102. https://doi.org/10.1002/eqe.3126.   DOI
66 Castaldo, P., Amendola, G. and Palazzo, B. (2017), "Seismic fragility and reliability of structures isolated by friction pendulum devices: seismic reliability-based design (SRBD)", Earthq. Eng. Struct. Dyn., 46(3), 425-446. https://doi.org/10.1002/eqe.2798.   DOI
67 Cha, Y.J., Zhang, J., Agrawal, A.K. and Dong, B. (2013), "Comparative studies of semiactive control strategies for MR dampers: pure simulation and real-time hybrid tests", J. Struct. Eng., 139(7): 1237-1248. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000639.   DOI
68 Han, X., Huang, D., Ji, J. and Lin, J. (2019), "Component deformation-based seismic design method for RC structure and engineering application" Earthq. Struct., 16(5), 575-588. https://doi.org/10.12989/eas.2019.16.5.575.   DOI
69 Bakhshinezhad, S. and Mohebbi, M. (2019a), "Multiple failure criteria-based fragility curves for structures equipped with SATMDs" Earthq. Struct., 17(5), 463-475. https://doi.org/10.12989/eas.2019.17.5.463.   DOI
70 Zemp, R., De La Llera, J.C., Saldias, H. and Weber, F (2016), "Development of a long-stroke MR damper for a building with tuned masses", Smart Mater. Struct., 25(10), 105006. https://doi.org/10.1088/0964-1726/25/10/105006.   DOI
71 Cornell, C.A., Jalayer, F., Hamburger, R.O. and Foutch, D.A. (2002), "Probabilistic basis for 2000 SAC federal emergency management agency steel moment frame guidelines", J. Struct. Eng., 128(4), 526-533. https://doi.org/10.1061/(ASCE)0733-9445(2002)128:4(526).   DOI
72 Ditlevsen, O. and Madsen, H.O. (1996), "Structural Reliability Methods", 1st Edition, John Wiley & Sons Ltd.
73 Eads, L., Miranda, E. and Lignos, D.G. (2015), "Average spectral acceleration as an intensity measure for collapse risk assessment", Earthq. Eng. Struct. Dyn., 44(12), 2057-2073. https://doi.org/10.1002/eqe.2575.   DOI
74 EN 15129. (2010), "Anti-seismic devices", European Committee for Standardization.
75 FEMA-356. (2000), "Prestandard and commentary for seismic rehabilitation of buildings", Washington DC: FEMA Publication 356.
76 Bakhshinezhad, S. and Mohebbi, M. (2021), "Multiple failure function based fragility curves for structures equipped with TMD", Earthq. Eng. Eng. Vib., 20, 471-482. https://doi.org/10.1007/s11803-021-2032-9.   DOI
77 Bathaei, A., Zahrai, S.M. and Ramezani, M. (2017), "Semi-active seismic control of an 11-DOF building model with TMD+MR damper using type-1 and -2 fuzzy algorithms", J. Vib. Control, 24(13), 2938-2953. https://doi.org/10.1177/1077546317696369.   DOI