Browse > Article
http://dx.doi.org/10.12989/eas.2020.19.1.45

Evaluation of structural operativity of two strategic buildings through Seismic Model  

Foti, Dora (Dipartimento di Scienze dell'Ingegneria Civile e dell'Architettura)
Giannoccaro, Nicola Ivan (Dipartimento di Ingegneria dell'Innovazione, Universita del Salento)
Greco, Pierluigi (Dipartimento di Scienze dell'Ingegneria Civile e dell'Architettura)
Lerna, Michela (Dipartimento di Scienze dell'Ingegneria Civile e dell'Architettura)
Paolicelli, Raffaele (Dipartimento di Scienze dell'Ingegneria Civile e dell'Architettura)
Vacca, Vitantonio (Consiglio Nazionale delle Ricerche - Istituto di Geologia Ambientale e Geoingegneria)
Publication Information
Earthquakes and Structures / v.19, no.1, 2020 , pp. 45-57 More about this Journal
Abstract
This paper presents the experimental application of a new method for seismic vulnerability assessment of buildings recently introduced in literature, the SMAV (Seismic Model Ambient Vibration) methodology with reference to their operational limit state. The importance of this kind of evaluation arises from the civil protection necessity that some buildings, considered strategic for seismic emergency management, should retain their functionality also after a destructive earthquake. They do not suffer such damage as to compromise the operation within a framework of assessment of the overall capacity of the urban system. To this end, for the characterization of their operational vulnerability, a Structural Operational Index (IOPS) has been considered. In particular, the dynamic environmental vibrations of the two considered strategic buildings, the fire station and the town hall building of a small town in the South of Italy, have been monitored by positioning accelerometers in well-defined points. These measurements were processed through modern Operational Modal Analysis techniques (OMA) in order to identify natural frequencies and modal shapes. Once these parameters have been determined, the structural operational efficiency index of the buildings has been determined evaluating the seismic vulnerability of the strategic structures analyzed. his study aimed to develop a model to accurately predict the acceleration of structural systems during an earthquake.
Keywords
seismic vulnerability; operational modal analysis; equivalent linear model; structural operative index; nondestructive techniques; ambient vibrations; dynamic analysis;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Foti, D., Giannoccaro, N.I., Diaferio, M. and Ivorra, S. (2015), "Structural identification and numerical models for slender historical structures" in Handbook of Research on Seismic Assessment and Rehabilitation of Historic Structures, 674-703, IGI Global, Hershey, Pennsylvania, U.S.A.
2 Ivorra, S., Foti, D., Gallo, V., Vacca, V. and Bru, D. (2019a), "Bell 's dynamic interaction on a singular concrete bell tower: A case of Study", Eng. Struct., 183, 965-975. https://doi.org/10.1016/j.engstruct.2019.01.071.   DOI
3 Ivorra, S., Giannoccaro, N.I. and Foti, D. (2019b), "Simple model for predicting the vibration transmission of a squat masonry tower by base forced vibrations", Struct. Control Hlth. Monit., 26(6), 1-21. https://doi.org/10.1002/stc.2360.
4 Mazza, F. (2019a) "A plastic-damage hysteretic model to reproduce strength stiffness degradation." Bulletin of Earthquake Engineering, 17, 3517-3544.   DOI
5 Mazza, F. (2019b), "A simplified retrofitting method based on seismic damage of a SDOF system equivalent to a damped braced building", Eng. Struct., 200, 109712. https://doi.org/10.1016/j.engstruct.2019.109712.   DOI
6 Mazza, F. (2019c), "In-plane-out-of-plane non-linear model of masonry infills in the seismic analysis of r.c.-framed buildings", Earthq, Eng. Struct. Dyn. 48(4), 432-453. https://doi.org/10.1002/eqe.3143.
7 Michel, C., Zapico, B., Lestuzzi, P., Molina, F.J. and Weber, F. (2011), "Quantification of fundamental frequency drop for unreinforced masonry buildings from dynamic tests", Earthq. Eng. Struct. Dyn., 40(11), 1283-1296. https://doi.org/10.1002/eqe.1088.   DOI
8 Mori, F. and Spina, D. (2015), "Vulnerability assessment of buildings based on ambient vibrations measurements", Struct. Monit. Maintenance, 2(2), 115-132. https://doi.org10.12989/smm.2015.2.2.115   DOI
9 Norme Tecniche per le Costruzioni (NTC-2018), "D.M. 17 Gennaio 2018, Gazzetta Ufficiale 20 Febbraio 2018, Rome, Italy.
10 Peeters B. and De Roeck, G. (2001), "Stochastic system identifcation for operatinal modal analysis: a review", J. Dyn Syst. Meas. Control, 123, 659-667. https://doi.org/10.1115/1.1410370.   DOI
11 Ranieri, C. and Fabbrocino, G. (2014), "Operational modal analysis of civil engineering structures: an introduction and guide for applications", Springer, Berlin, Germany.
12 Reynders, E. (2012), "System identification methods for (operational) modal analysis: review and comparison", Archives Comput. Meth. Eng., 19, 51-124. https://doi.org/10.1007/s11831-012-9069-x.   DOI
13 Spina, D., Acunzo, G., Fiorini, N. and Dolce, M. (2019), "A probabilistic simplified seismic model of masonry buildings based on ambient vibrations", Bull. Earthq. Eng., 17(2), 985-1007. https://doi.org/10.1007/s10518-018-0481-y.   DOI
14 Tekeli H., Dilmac H., Demir, F., Gencoglu, M. and Guler, K. (2017), "Shear stress indicator to predict seismic performance of residential RC buildings", Comput. Concrete, 19(3), 283-291. https://doi.org/10.12989/cac.2017.19.3.283.   DOI
15 Acunzo, G., Fiorini, N., Mori, F. and Spina, D. (2015), "VaSCOsmav: il software sviluppato per l'applicazione della metodologia SMAV", The Proceedings of the XVI Conference ANIDIS, September.
16 Acunzo, G., Fiorini N., Mori F. and Spina, D. (2018), "Modal mass estimation from ambient vibrations measurement: A method for civil buildings", Mech. Syst. Signal Processing, 98, 580-593. https://doi.org/10.1016/j.ymssp.2017.05.014.   DOI
17 ARTeMIS (2019), "Ambient Response Testing and Modal Identification Software ARTeMIS Extractor Pro 5.3. Structural Vibration Solution A/S Aalborg East", Denmark. www.svibs.com
18 Bramerini, F. and Castenetto, S. (2014) "Manuale per l'analisi della Condizione Limite per l'Emergenza (CLE) dell'insediamento urbano, Versione 2.0", Betmultimedia, Roma, Italy.
19 Diaferio, M., Foti, D., Ivorra, S., Giannoccaro, N.I., Notarangelo, G. and Vitti, M. (2019), "Monitoring and structural identification of a "Star-shaped" reinforced concrete bell tower", The 8th IOMAC - International Operational Modal Analysis Conference, Proceedings, 47-54.
20 Bru, D., Ivorra, S., Baeza, F.J., Reynau, R. and Foti, D. (2015), "OMA Dynamic Identification of a Masonry Chimney with Severe Cracking Condition", The 6th International Operational Modal Analysis Conference, Proceedings.
21 Dunand, F. (2005), "Relevance of seismic noise for dynamic characterization using seismic and diagnosis of civil engineering structures", Ph. D Dissertation, University Joseph Fourier, Grenoble.
22 Foti, D., Diaferio, M., Giannoccaro N.I. and Mongelli M. (2012), "Ambient vibration testing, dynamic identification and model updating of a historic tower" NDT. E. Int., 47, 88-95. https://doi.org/10.1016/j.ndteint.2011.11.009.   DOI