Abstract
The concept of the combined seismic and energy retrofitting of existing reinforced concrete (RC) buildings was examined in this paper through a number of case studies conducted on model buildings (simulating buildings of the '60s-'80s in southern Europe) constructed according to outdated design standards. Specifically, seismic and thermal analyses have been conducted prior to and after the application of selected retrofitting schemes, in order to quantify the positive effect that retrofitting could provide to RC buildings both in terms of their structural and energy performance. Advanced materials, namely the textile reinforced mortars (TRM), were used for providing seismic retrofitting by means of jacketing of masonry infills in RC frames. Moreover, following the application of the TRM jackets, thermal insulation materials were simultaneously provided to the RC building envelope, exploiting the fresh mortar used to bind the TRM jackets. In addition to the externally applied insulation material, all the fenestration elements (windows and doors) were replaced with new high energy efficiency ones. Afterwards, an economic measure, namely the expected annual loss (EAL) was used to evaluate the efficiency of each retrofitting method, but also to assess whether the combined seismic and energy retrofitting is economically feasible. From the results of this preliminary study, it was concluded that the selected seismic retrofitting technique can indeed enhance significantly the structural behaviour of an existing RC building and lower its EAL related to earthquake risks. Finally, it was found that the combined seismic and energy upgrading is economically more efficient than a sole energy or seismic retrofitting scenario for seismic areas of south Europe.
Keywords
advanced materials; building envelope; energy retrofitting; infill strengthening; textile reinforced mortar (TRM); thermal insulation;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Koutas, L.N., Triantafillou, T.C. and Bousias, S.N. (2015b), "Analytical modelling of masonry-infilled RC frames with textile-reinforced mortar", J. Compos. Constr., 19(5), 04014082.   DOI
2 Marini, A., Passoni, C., Belleri, A., Feroldi, F., Preti, M., Metelli, G., Riva, P., Giurani, E. and Plizzari, G. (2017), "Combining seismic retrofit with energy refurbishment for the sustainable renovation of RC buildings: a proof of concept", Eur. J. Environ. Civil Eng., DOI: 10.1080/19648189.2017.1363665.
3 Mastroberti, M., Bournas, D.A., Vona, M. and Palermo, V. (2018), "Combined seismic plus energy retrofitting for the existing RC buildings: Economic feasibility and environmental benefits", European Conference on Earthquake Engineering, Thessaloniki, Greece, June.
4 Mondal, G. and Jain, S.K. (2008), "Lateral stiffness of masonry infilled Reinforced Concrete (RC) frames with central opening", Earthq. Spectra, 24(3), 701-723.   DOI
5 OpenSees (1999), http://opensees.berkeley.edu/
6 Poljansek, M., Taucer, F., Chrysostomou, C., Kyriakides, N., Onoufriou, T., Roussis, P., Kotronis, P., Panagiotakos, T., Kosmopoulos, A. and Molina, J.R. (2014), "Seismic retrofitting of RC frames with RC infilling (SERFIN Project)", Research Report No. 227887, Joint Research Centre, Ispra, Italy.
7 Raoof, S. and Bournas, D.A. (2017a), "TRM versus FRP in flexural strengthening of RC beams: Behaviour at high temperatures", Constr. Build. Mater., 154, 424-437.   DOI
8 Raoof, S. and Bournas, D.A. (2017b), "Bond between TRM versus FRP composites and concrete at high temperatures", Compos. Part B, 127, 150-165.   DOI
9 Tasnimi, A.A. and Mohebkhah, A. (2011), "Investigation on the behavior of brick-infilled steel frames with openings, experimental and analytical approaches", Eng. Struct., 33(3), 968-980.   DOI
10 Tetta, Z.C. and Bournas, D.A. (2016), "TRM vs FRP jacketing in shear strengthening of concrete members subjected to high temperatures", Compos. Part B, 106, 190-205.   DOI
11 Triantafillou, T.C., Karlos, K., Kapsalis, P. and Georgiou, L. (2018), "Innovative structural and energy retrofitting system for masonry walls using textile reinforced mortars combined with thermal insulation: In-plane Mechanical behavior", J. Compos. Constr., 22(5), 04018029.   DOI
12 Triantafillou, T.C., Karlos, K., Kefalou, K. and Argyropoulou, E. (2017), "An innovative structural and energy retrofitting system for URM walls using textile reinforced mortars combined with thermal insulation: Mechanical and fire behavior", Constr. Build. Mater., 133, 1-13.   DOI
13 Tsonos, G.A. (2008), "Effectiveness of CFRP-jackets and RCjackets in post-earthquake and pre-earthquake retrofitting of beam-column subassemblages", Eng. Struct., 30(3), 777-793.   DOI
14 Tsonos, G.A. (2014), "An innovative solution for strengthening of old R/C structures and for improving the FRP strengthening method", Struct. Monit. Mainten., 1(3), 323-338.   DOI
15 Vamvatsikos, D. and Cornell, C.A. (2001), "Incremental dynamic analysis", Earthq. Eng. Struct. Dyn., 31(3), 491-514.   DOI
16 Belleri, A. and Marini, A. (2016), "Does seismic risk affect the environmental impact of existing buildings?", Energy Build., 110, 149-158.   DOI
17 Al-Chaar, G., Lamb, G.E. and Issa, M.A. (2003), "Effect of openings on structural performance of unreinforced masonry infilled frames", ACI, 211, 247-261.
18 Antonopoulos, C.P. and Triantafillou, T.C. (2003), "Experimental investigation of FRP-strengthened RC beam-column joints", J. Compos. Constr., ASCE, 7(1), 39-49.   DOI
19 Asteris, P.G., Giannopoulos, I.P. and Chrysostomou, C.Z. (2012), "Modeling of infilled frames with openings", Open Constr. Build. Tech. J., 6, 81-91.   DOI
20 Atanasiou, B., Despret, C., Economidou, M., Maio, J., Nolte, I. and Rapf, O. (2011), "Europe's buildings under the microscope: A country-by-country review of the energy performance of buildings", Research Report No. 9789491143014, Buildings Performance Institute Europe (BPIE).
21 Calvi, G.M. (2013), "Choices and criteria for seismic strengthening", J. Earthq. Eng., 17(6), 769-802.   DOI
22 Bournas, D.A. (2018a), "Concurrent seismic and energy retrofitting of RC and masonry building envelopes using inorganic textile-based composites with insulation materials: A new concept", Compos. Part B: Eng., 148, 166-179.   DOI
23 Bournas, D.A. (2018b), "Innovative materials for seismic and energy retrofitting of the existing EU buildings", Research Report, No. EUR 29184 EN, Joint Research Centre, Ispra, Italy.
24 Bournas, D.A., Triantafillou, T.C., Zygouris, K. and Stavropoulos, F. (2009), "Textile-Reinforced Mortar (TRM) versus FRP jacketing in seismic retrofitting of RC columns with continuous or lap-spliced deformed vars", J. Compos. Constr., ASCE, 13(5), 360-371.   DOI
25 Calvi, G.M., Sousa, L. and Ruggeri, C. (2016), "Energy efficiency and seismic resilience: A common approach", Multi-hazard Approaches to Civil Infrastructure Engineering, Springer International Publishing.
26 EnergyPlus (1997), https://energyplus.net/
27 Chalioris, C.E., Papadopoulos, C.P., Pourzitidis, C.N., Fotis, D. and Sideris, K.K. (2013), "Application of a reinforced selfcompacting concrete jacket in damaged reinforced concrete beams under monotonic and repeated loading", J. Eng., Article ID 912983, 12.
28 Chalioris, C.E., Thermou, G.E. and Pantazopoulou, S.J. (2014), "Behaviour of rehabilitated RC beams with self-compacting concrete jacketing-Analytical model and test results", Constr. Build. Mater., 55, 257-273.   DOI
29 Chen, X. and Liu, Y. (2015), "Numerical study of in-plane behavior and strength of concrete masonry infills with openings", Eng. Struct., 82, 226-235.   DOI
30 Daskalaki, E.G., Droutsa, K., Balaras, K.A. and Kontogiannidis, S. (2016), "Typology of Greek residency buildings", Research Report, Institute of Environmental Research, Sustainable Development and National Observatory of Athens, Athens. (in Greek)
31 Eurocode (2004), Eurocode 8: Design of Structures for Earthquake Resistance-Part 1: General Rules, Seismic Actions and Rules for Buildings, European Committee for Standardization, Brussels, Belgium.
32 Eurocode (2005), Eurocode 8: Design of Structures for Earthquake Resistance-Part 3: Assessment and Retrofitting of Buildings, European Committee for Standardization, Brussels, Belgium.
33 Eurostat (2018), https://ec.europa.eu/eurostat/
34 Fardis, M.N. and Panagiotakos, T.B. (1997), "Seismic design and response of bare and masonry-infilled reinforced concrete buildings. Part II: Infilled structures", J. Earthq. Eng., 1(3), 475-503.   DOI
35 Favvata, M., Naoum, M. and Karayannis, C. (2013), "Limit states of RC structures with first floor irregularities", Struct. Eng. Mech., 47(6), 791-818.   DOI
36 Julio, E.S., Branco, F. and Silva, V.D. (2003), "Structural rehabilitation of columns with reinforced concrete jacketing", Prog. Struct. Eng Mater., 5, 29-37.   DOI
37 Grondzik, W.T., Kwok, A.G., Stein, B. and Reynolds, J.S. (2010), Mechanical and Electrical Equipment for Buildings, 11th Edition, John Wiley & Sons, Inc.
38 HAZUS99 (1999), Technical and User's Manual, Washington DC.
39 Immobiliare (2018), https://www.immobiliare.it/
40 Interactive Seismic Hazard Maps (2007), http://esse1-gis.mi.ingv.it/
41 Kakaletsis, D.J. and Karayannis, C.G. (2008), "Influence of masonry strength and openings on infilled R/C frames under cycling loading", J. Earthq. Eng., 12(2), 197-221.   DOI
42 Kalogeropoulos, G.I., Tsonos, G.A., Konstandinidis, D. and Tsetines, S. (2016), "Pre-earthquake and post-earthquake retrofitting of poorly detailed exterior RC beam-to-column joints", Eng. Struct., 109, 1-15.   DOI
43 Karlos, K. and Triantafillou, T.C. (2018), "Innovative integrated structural and energy retrofitting system for masonry walls using textile reinforced mortars combined with thermal insulation", European Conference on Earthquake Engineering, Thessaloniki, Greece, June.
44 FEMA-306 (1999), Evaluation of Earthquake Damaged Concrete and Masonry Wall Buildings.Basic Procedures Manual, Chapter 8, Infilled Frames, ATC, CA.
45 Koutas, L., Tetta, Z., Bournas, D.A. and Triantafillou, T.C. (2019), "A strengthening of concrete structures with Textile Reinforced Mortars (TRM): State-of-the-art review", Doctoral Dissertation, American Society of Civil Engineers.
46 Koutas, L.N. and Bournas, D.A. (2019), "Out-of-plane strengthening of masonry-infilled RC frames with textilereinforced mortar jackets", J. Compos. Constr., 23(1), 04018079.   DOI
47 Koutas, L.N., Bousias, S.N. and Triantafillou, T.C. (2015a), "Seismic strengthening of masonry-infilled RC frames retrofitted with textile-reinforced mortar", J. Compos. Constr., 19(2), 04014048.   DOI