Abstract
To study the effectiveness of sliding isolation in a CRLSS (concrete rectangular liquid-storage structure) and develop a reasonable limiting-device method, dynamic responses of non-isolation, sliding isolation with spring limiting-devices and sliding isolation with steel bar limiting-devices are comparatively studied by shaking table test. The seismic response reduction advantage of sliding isolation for concrete liquid-storage structures is discussed, and the effect of the limiting-device type on system dynamic responses is analyzed. The results show that the dynamic responses of sliding isolation CRLSS with steel bar-limiting devices are significantly smaller than that of sliding isolation CRLSS with spring-limiting devices. The structure acceleration and liquid sloshing wave height are greatly influenced by spring-limiting devices. The acceleration of the structure in this case is close to or greater than that of a non-isolated structure. Liquid sloshing shows stronger nonlinear characteristics. On the other hand, sliding isolation with steel bar-limiting devices has a good control effect on the structural dynamic response and the liquid sloshing height simultaneously. Thus, a limiting device is an important factor affecting the seismic response reduction effect of sliding isolation. To take full advantage of sliding isolation in a concrete liquid-storage structure, a reasonable design of the limiting device is particularly important.
Keywords
sliding isolation; concrete rectangular liquid-storage structure; limiting device; shaking table test; dynamic response;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Abali, E. and Uckan, E. (2010), "Parametric analysis of liquid storage tanks base isolated by curved surface sliding bearings", Soil Dyn. Earthq. Eng., 30, 21-31.   DOI
2 Angelis, M.D., Giannini, R. and Paolacci, F. (2010), "Experimental investigation on the seismic response of a steel liquid storage tank equipped with floating roof by shaking table tests", Earthq. Eng. Struct. Dyn., 39(4), 377-396.   DOI
3 Chakraborty, S., Roy, K. and Ray-Chaudhuri, S. (2016), "Design of re-centering spring for flat sliding base isolation system: Theory and a numerical study", Eng. Struct., 126, 66-77.   DOI
4 Chalhoub, M.S. and Kelly, J.M. (1990), "Shake table test of cylindrical water tanks in base-isolated structures", J. Eng. Mech., ASCE, 116(7), 1451-1472.   DOI
5 Cheng, X.S., Cao, L.L. and Zhu, H.Y. (2015), "Liquid-solid interaction seismic response of an isolated overground rectangular reinforced-concrete liquid-storage structure", J. Asian Arch. Build. Eng., 14, 175-180.   DOI
6 Cheng, X.S., Jing, W. and Gong, L.J. (2017), "Simplified model and energy dissipation characteristics of a rectangular liquid-storage structure controlled with sliding base isolation and displacement-limiting devices", J. Perform. Constr. Facil., ASCE, 31(5), 1-11.
7 Fan, J. and Tang, J.X. (2001), "Dynamic characteristics and earthquake response analysis of structures supported on slidelimited friction base isolation system", J. Build. Struct., 22(1), 20-25.
8 Gao, L., Guo, E.D., Wang, X.J. et al. (2012), "Earthquake damage analysis of pools in water supply system", J. Nat. Disast., 21(5), 120-126.
9 GB50011-2010 (2016), Code for Seismic Design of Buildings, China Architecture & Building Press, Beijing.
10 Jaiswal, O.R., Rai, D.C. and Jain, S.K. (2007), "Review of seismic codes on liquid-containing tanks", Earthq. Spectra, 23(1), 239-260.   DOI
11 Lu, L.Y., Lin, C.C. and Lin, G.L. (2013), "Experimental evaluation of supplemental viscous damping for a sliding isolation system under pulse-like base excitations", J. Sound Vib., 332(8), 1982-1999.   DOI
12 Jalali, A., Cardone, D. and Narjabadifam, P. (2011), "Smart restorable sliding base isolation system", Bull. Earthq. Eng., 9(2), 657-673.   DOI
13 Kim, N.S. and Lee, D.G. (1995), "Pseudo-dynamic test for evaluation of seismic performance of base isolated liquid storage tanks", Eng. Struct., 17(3), 198-208.   DOI
14 Li, J., Chen, H.M., Chen, J.B. et al. (2006), "An experimental study on prestressed egg-shape digesters", China Civil Eng. J., 39(5), 35-42
15 Li, X.Y. and Xue, S.D. (2011), "Model and design method of a sliding bearing combimed with springs for horizontal seismic isolation", J. Beijing Univ. Technol., 37(11), 1650-1654.
16 Li, Z.J. and Deng, Z.C. (2008), "Fuzzy sliding mode control of sliding-isolated buildings", J. Vib. Shock, 27(9), 111-115.
17 Madden, G.J., Symans, M.D. and Wongprasert, N. (2002), "Experimental verification of seismic response of building frame with adaptive sliding base-isolation system", J. Struct. Eng., 128(8), 1037-1045.   DOI
18 Malhotra, P.K. (1997), "New method for seismic isolation of liquid storage tanks", Earthq. Eng. Struct. Dyn., 26(8), 839-847.   DOI
19 Panchal, V.R. and Jangid, R.S. (2011), "Seismic response of liquid storage steel tanks with variable frequency pendulum isolator", KSCE J. Civil Eng., 15(6), 1041-1055.   DOI
20 Rai, D.C. (2002), "Seismic retrofitting of R/C shaft support of elevated tanks", Earthq. Spectra, 18(4), 745-760.   DOI
21 Zhang, R.F., Weng, D.G. and Ren, X.S. (2011), "Seismic analysis of a LNG storage tank isolated by a multiple friction pendulum system", Earthq. Eng. Eng. Vib., 10(2), 253-262.   DOI
22 Saha, S.K., Matsagar, V.A. and Jain, A.K. (2016), "Seismic fragility of base-isolated water storage tanks under non-stationary earthquakes", Bull. Earthq. Eng., 14(4), 1153-1175.   DOI
23 Saha, S.K., Sepahvand, K., Matsagar, V.A. et al. (2013), "Stochastic analysis of base-isolated liquid storage tanks with uncertain isolator parameters under random excitation", Eng. Struct., 57(4), 465-474.   DOI
24 Shekari, M.R. and Khaji, N. (2010), "Ahmadi M T. On the seismic behavior of cylindrical base-isolated liquid storage tanks excited by long-period ground motions", Soil Dyn. Earthq. Eng., 30(10), 968-980.   DOI
25 Yang, Y., Sun, J.G., Zou, D.L. et al. (2011), "Research on the foundation slipping-isolation of vertical storage tanks", Oil-Gasfield Surf. Eng., 30(2), 30-32.
26 Zhang, R.F., Weng, D.G. and Ge, Q.Z. (2014), "Shaking table experiment on a steel storage tank with multiple friction pendulum bearings", Struct. Eng. Mech., 52(5), 875-887.   DOI
27 Zou, S., Ikago, K., Inoue, N. et al. (2016), "Design optimization of friction damper with coupling mechanism for seismic response of base isolated structure", J. Vib. Eng., 29(2), 201-206.