Browse > Article
http://dx.doi.org/10.12989/eas.2015.9.6.1291

Seismic performance evaluation of moment frames with slit-friction hybrid dampers  

Lee, Joonho (Department of Civil and Architectural Engineering, Sungkyunkwan University)
Kim, Jinkoo (Department of Civil and Architectural Engineering, Sungkyunkwan University)
Publication Information
Earthquakes and Structures / v.9, no.6, 2015 , pp. 1291-1311 More about this Journal
Abstract
This study investigates the seismic energy dissipation capacity of a hybrid passive damper composed of a friction and a hysteretic slit damper. The capacity of the hybrid device required to satisfy a given target performance of a reinforced concrete moment resisting frame designed with reduced design base shear is determined based on the ASCE/SEI 7-10 process, and the seismic performances of the structures designed without and with the hybrid dampers are verified by nonlinear dynamic analyses. Fragility analysis is carried out to investigate the probability of a specified limit state to be reached. The analysis results show that in the structure with hybrid dampers the residual displacements are generally reduced and the dissipated inelastic energy is mostly concentrated on the dampers. At the Moderate to Extensive damage states the fragility turned out to be smallest in the structure with the hybrid dampers.
Keywords
hybrid dampers; slit dampers; friction dampers; seismic performance; fragility analysis;
Citations & Related Records
Times Cited By KSCI : 7  (Citation Analysis)
연도 인용수 순위
1 ACI Committee 318 (2011), Building Code Requirements for Structural Concrete and Commentary.
2 American Society of Civil Engineers (2010), Minimum Design Loads for Buildings and Other Structures (ASCE/SEI 7-10): Reston.
3 Aydin, E., Boduroglub, M.H. and Guney, D. (2007), "Optimal damper distribution for seismic rehabilitation of planar building structures", Eng. Struct., 29(2), 176-185.   DOI
4 Bergman, D.M. and Goel, S.C. (1987), Evaluation of cyclic testing of steel plate devices for added damping and stiffness, Report no. UMCE87-10. The University of Michigan.
5 Blau, P. (2001), Compositions, functions, and testing of friction brake materials and their additives, Technical Report ORNL/TM-2001/64, Oak Ridge National Laboratory.
6 Chan, R.W.K. and Albermani, F. (2008), "Experimental study of slit damper for passive energy dissipation", Eng. Struct., 30(4), 1058-1066.   DOI
7 Celik, O.C. and Ellingwood, B.R. (2009), "Seismic risk assessment of gravity load designed reinforced concrete frames subjected to Mid-America ground motions", J. Struct. Eng., 135(4), 414-424.   DOI
8 Chen, C.-S., Chen, K.-C., Pong, W.S. and Tsai, C.S. (2002), "Parametric study for buildings with combined displacement-dependent and velocity-dependent energy dissipation devices", Struct. Eng. Mech., 14(1), 85-98.   DOI
9 Choi, H. and Kim, J. (2006), "Energy-based seismic design of buckling-restrained braced frames using hysteretic energy spectrum", Eng. Struct., 28(2), 304-311.   DOI
10 Choi, K.S. and Kim, H.J. (2014), "Strength demand of hysteretic energy dissipating devices alternative to coupling beams in high-rise buildings", Int. J. High-Rise Build., 3(2), 107-120
11 Damptech (2014), Friction Dampers-Capacities and Dimensions. http://www.damptech.com/download.html
12 Kim, J., Park, J. and Kim, S.D. (2009), "Seismic behavior factors of buckling-restrained braced frames", Struct. Eng. Mech., 33(3), 261-284.   DOI
13 Murakami, Y., Noshi, K., Fujita, K., Tsuji, M. and Takewaki, I. (2013), "Simultaneous optimal damper placement using oil, hysteretic and inertial mass dampers", Earthq. Struct., 5(3), 261-276.   DOI
14 Kim, J., Choi, H. and Min, K. (2011), "Use of rotational friction dampers to enhance seismic and progressive collapse resisting capacity of structures", Struct. Des. Tall Spec. Build., 20(4), 515-537.   DOI
15 Lee, S.K., Park, J.H., Moon, B.W., Min, K.W., Lee, S.H. and Kim, J. (2008), "Design of a bracing-friction damper system for seismic retrofitting", Smart Struct. Syst., 4(5), 685-696.   DOI
16 Marshall, J.D. and Charney, F.A. (2012), "Seismic response of steel frame structures with hybrid passive control systems", Earthq. Eng. Struct. Dyn., 41(4), 715-733.   DOI
17 Oh, S.H., Kim, Y.J. and Ryu, H.S. "Seismic performance of steel structures with slit dampers", Eng. Struct., 31(9), 1997-2008.   DOI
18 Patel, C.C. and Jangid, R.S. (2011), "Dynamic response of adjacent structures connected by friction dampers", Earthq. Struct., 2(2), 149-169.   DOI
19 Perform 3D (2006), Computer and Structures, Inc. PERFORM User Guide ver 4.
20 Suresh, G. and Andy, R. (1991), "Planar sliding with dry friction Part 2. Dynamics of motion", Wear, 20(2), 331-352.
21 Tsai, C.S., Chen, K.-C. and Chen, C.-S. (1998), "Seismic resistibility of high-rise buildings with combined velocity-dependent and velocity-independent devices", ASME Pressure Vessels and Piping Conference, San Diego, CA.
22 Tremblay, R., Chen, L. and Tirca, L. (2014), "Enhancing the seismic performance of multi-storey buildings with a modular tied braced frame system with added energy dissipating devices", Int. J. High-Rise Build., 3(1), 21-33.
23 Uetani, K., Tsuji, M. and Takewaki, I. (2003), "Application of optimum design method to practical building frames with viscous dampers and hysteretic dampers", Eng. Struct., 25(5), 579-592.   DOI