Browse > Article
http://dx.doi.org/10.12989/eas.2015.8.2.305

Earthquake induced torsion in buildings: critical review and state of the art  

Anagnostopoulos, S.A. (Department of Civil Engineering University of Patras)
Kyrkos, M.T. (Attica Region)
Stathopoulos, K.G. (DOMI-Consulting Engineers)
Publication Information
Earthquakes and Structures / v.8, no.2, 2015 , pp. 305-377 More about this Journal
Abstract
The problem of earthquake induced torsion in buildings is quite old and although it has received a lot of attention in the past several decades, it is still open. This is evident not only from the variability of the pertinent provisions in various modern codes but also from conflicting results debated in the literature. Most of the conducted research on this problem has been based on very simplified, highly idealized models of eccentric one-story systems, with single or double eccentricity and with load bearing elements of the shear beam type, sized only for earthquake action. Initially, elastic models were used but were gradually replaced by inelastic models, since building response under design level earthquakes is expected to be inelastic. Code provisions till today have been based mostly on results from one-story inelastic models or on results from elastic multistory idealizations. In the past decade, however, more accurate multi story inelastic building response has been studied using the well-known and far more accurate plastic hinge model for flexural members. On the basis of such research some interesting conclusions have been drawn, revising older views about the inelastic response of buildings based on one-story simplified model results. The present paper traces these developments and presents new findings that can explain long lasting controversies in this area and at the same time may raise questions about the adequacy of code provisions based on results from questionable models. To organize this review better it was necessary to group the various publications into a number of subtopics and within each subtopic to separate them into smaller groups according to the basic assumptions and/or limitations used. Capacity assessment of irregular buildings and new technologies to control torsional motion have also been included.
Keywords
torsion; buildings; earthquake; review; eccentricity; codes; assessment; elastic; inelastic;
Citations & Related Records
Times Cited By KSCI : 10  (Citation Analysis)
연도 인용수 순위
1 Tsicnias, T.G. and Hutchinson, G.L. (1984), "Soil-structure interaction effects on the steady-state response of the torsionally coupled buildings", Earthq. Eng. Struct. Dyn., 12(2), 237-262.   DOI
2 Tso, W.K. (1975), "Induced torsional oscillations in symmetrical structures", Earthq. Eng. Struct. Dyn., 3(4), 337-346.   DOI
3 Tso, W.K. and Dempsey, K.M. (1980), "Seismic torsional provisions for dynamic eccentricity", Earthq. Eng. Struct. Dyn., 8(3), 275-289.   DOI
4 Wu, W.H., Wang, J.F., Lin, C.C. (2001), "Systematic assessment of irregular building-soil interaction using efficient modal analysis", Earthq. Eng. Struct. Dyn., 30(4), 573-594.   DOI
5 Adachi, F., Yoshitomi, S., Masaaki, T. and Takewaki, I. (2011), "Enhanced reduced model for elastic earthquake response analysis of a class of mono-symmetric shear building structures with constant eccentricity", Soil. Dyn. Earthq. Eng., 31, 1040-1050.   DOI
6 Anagnostopoulos, S.A. (1981), "Response spectrum techniques for three component earthquake design", Earthq. Eng. Struct. Dyn., 9(5), 459-476.   DOI
7 Athanatopoulou, A.M., Makarios, T. and Anastassiadis, K. (2006), "Earthquake analysis of isotropic asymmetric multistory buildings", Struct. Des. Tall Spec. Build., 15, 417-443.   DOI
8 Basu, D. and Jain, S.K. (2007), "Alternative methods to locate centre of rigidity in asymmetric buildings", Earthq. Eng. Struct. Dyn., 36(7), 965-973.   DOI
9 Bosco, M., Marino, E. and Rossi, P.P. (2004), "Limits of application of simplified design procedures to nonregularly asymmetric buildings", Proceedings of the 13th World Conference, Earthq. Eng.
10 De La Llera, J.C. and Chopra, A.K. (1996), "Inelastic behaviour of asymmetric multistory buildings", J. Struct. Eng., 122(6), 597-606.   DOI
11 Duan, X.N. and Chandler, A.M. (1993), "Inelastic seismic response of code-designed multi-storey frame buildings with regular asymmetry", Earthq. Eng. Struct. Dyn., 22(5), 431-445.   DOI
12 Duan, X.N. and Chandler, A.M. (1995), "Seismic torsional response and design procedures for a class of setback frame buildings", Earthq. Eng. Struct. Dyn., 24(5), 761-778.   DOI
13 Dutta, S.C. and Roy, R. (2012), "Seismic demand of low-rise multistory systems with general asymmetry", J. Eng. Mech., 138(1), 1-11.   DOI
14 Kosmopoulos, A.J. and Fardis, M.N. (2008), "Simple models for inelastic seismic analysis of asymmetric multistory RC buildings", J. Earthq. Eng., 12, 704-727.   DOI
15 Tso, W.K. and Moghadam, A.S. (1998), "Application of Eurocode 8 torsional provisions to multi-storey buildings", Proceedings of the 11th European Conference, Earthq. Eng.
16 Aldeka, A.B., Chan, A.H.C. and Dirar, S. (2014) "Response of non-structural components mounted on irregular RC buildings: comparison between FE and EC8 predictions", Earthq. Struct., 6(4), 351-373.   DOI
17 Anagnostopoulos, S.A., Alexopoulou, C. and Stathopoulos, K.G. (2008), "Are results for inelastic torsion in buildings based on simplified, one-storey, shear beam models, applicable to actual multistory buildings?", Invited paper, Proceedings of the 5th European Workshop on the Seismic behaviour of irregular and complex structures, Catania, Italy.
18 Tso, W.K. and Moghadam, A.S. (1997), "Seismic response of asymmetric buildings using pushover analysis", Seismic Design Methodologies for the Next Generation of Codes, Eds. Fajfar and Krawinkler.
19 Shakeri, K., Tarbali, K. and Mohhebi, M. (2012), "An adaptive modal pushover procedure for asymmetricplan buildings", Eng. Struct., 36, 160-172.   DOI
20 Tabatabaei, R. and Saffari, H. (2011), "Evaluation ot the torsional response of multistory buildings using equivalent static eccentricity", J. Struct. Eng., 137(8), 862-868.   DOI
21 Almazan, J.L. and De La Llera, J.C. (2003), "Accidental torsion due to overturning in nominally symmetric structures isolated with FPS", Earthq. Eng. Struct. Dyn., 32(6), 919-948.   DOI
22 De La Llera, J. and Almazan, J.L. (2003), "An experimental study of nominally symmetric and asymmetric structures isolated with the FPS", Earthq. Eng. Struct. Dyn., 32(6), 891-918.   DOI
23 Hwang J.S., Hsu T.Y. (2000), "Experimental study of isolated building under triaxial ground excitations", J. Struct. Eng., ASCE, 126, 879-886.   DOI
24 Jangid, R.S. and Kelly J.M. (2000), "Torsional displacements in base-isolated buildings", Earthq. Spectra, 16(2), 443-454.   DOI
25 Kilar, V. and Koren, D. (2008), "Usage of simplified N2 method for analysis of base isolated structures", Proceedings of the 14th World Conference, Earthq. Eng.
26 Kilar, V. and Koren, D. (2009), "Seismic behaviour of asymmetric base isolated structures with various distributions of isolators", Eng. Struct., 31, 910-921.   DOI   ScienceOn
27 Der Kiureghian, A. (1979), "On response of structures to stationary excitation", Earthq. Eng. Research Center, Univ., No. EERC 79-32, California, Berkeley.
28 Bustamante, J.I. and Rosenblueth, E. (1960), "Buildng code provisions on torsional oscillation", Proceedings of the 2nd World Conference, Earthq. Eng., Japan.
29 Cardona, R. and Esteva, L. (1977), "Static analysis of asymmetric multistory structures", Proceedings of the 6th World Conference, Earthq. Eng.
30 Cheung, V.W.T. and Tso, W.K. (1986), "Eccentricity in irregular multistorey buildings", Can. J. Civ. Eng., 13(1), 46-52.   DOI   ScienceOn
31 Georgoussis, G. (2009), "An alternative approach for assessing eccentricities in asymmetric multi-story buildings: 1. Elastic systems", Struct. Des. Tall Spec. Build., 18(2), 181-202.   DOI
32 Georgoussis, G. (2010), "Modal rigidity center: it's use for assessing elastic torsion in asymmetric buildings", Earthq. Struct., 1(2),163-175.   DOI
33 Georgoussis, G. (2014), "Modified seismic analysis of multistory asymmetric elastic buildings and suggestions for minimizing the rotational response", Earthq. Struct., 7(1), 39-55.   DOI
34 Gluck, J., Reinhorn, A. and Rutenberg, A. (1979), "Dynamic torsional coupling in tall building structures", Proc. Inst. Civil Eng., 67(2), 411-424.   DOI
35 Goel, R.K. and Chopra, A.K. (1993), "Seismic code analysis of buildings without locating centers of rigidity", J. Struct. Eng., 119(10), 3039-3055.   DOI
36 Harasimowicz, A.P. and Goel, R.K. (1998), "Seismic code analysis of multi-storey asymmetric buildings", Earthq. Eng. Struct. Dyn., 27(2), 173-185.   DOI
37 Cruz, E.F. and Cominetti, S. (1992), "Nonlinear response of buildings, a parametric study", Proceedings of the 10th World Conference, Earthq. Eng., 7, 3663-6.
38 Anagnostopoulos, S.A., Alexopoulou, C. and Stathopoulos, K.G. (2009), "An answer to a persisting controversy in earthquake resistant design of asymmetric buildings for torsion", Invited keynote paper, Proceedings of the COMPDYN 2009, Rhodos, Greece.
39 Anagnostopoulos, S.A., Alexopoulou, C. and Stathopoulos, K. (2010) "An answer to an important controversy and the need for caution when using simple models to predict inelastic earthquake response of buildings with torsion", Earthq. Eng. Struct. Dyn., 39, 521-540.
40 Boroschek, R.L. and Mahin, S.A. (1992), "Investigation of coupled lateral-torsional response in multistorey buildings", Proceedings of the 10th World Conference, Earthq. Eng.
41 Fernandez Davila, V.I. and Cruz, E.F. (2008), "Estimating inelastic bi-directional seismic response of multistory asymmetric buildings using a set of combination rules", Proceedings of the 14th World Conference, Earthq. Eng.
42 De Stefano, M., Faella, G. and Realfonzo, R. (1995), "Seismic response of 3D RC frames: Effects of plan irregularity", European Seismic Design Practice, Eds. Elnasai, Rottedam, Balkema, 219-226.
43 De Stefano, M., Marino, E.M. and Rossi, P.P. (2006), "Effect of overstrength on the seismic behaviour of multi-storey regularly asymmetric buildings", Bul. Earthq. Eng., 4, 23-42.   DOI
44 Erduran, E. and Ryan, K.L. (2011), "Effects of torsion on the behavior of peripheral steel-braced frame systems", Earthq. Eng. Struct. Dyn., 40(5), 491-507.   DOI
45 Nakamura, T., Suzuki, T., Okada, H. and Takeda. T. (1988), "Study on base isolation for torsional response reduction in asymmetric structures under earthquake motions", Proceedings of the 9th World Conference, Earthq. Eng.
46 Koren, D. and Kilar, V. (2011), "The applicability of the N2 method to the estimation of torsional effects in asymmetric base-isolated buildings", Earthq. Eng. Struct. Dyn., 40(8), 867-886.   DOI   ScienceOn
47 Lee, D.M. (1980), "Base isolation for torsion reduction in asymmetric structures under earthquake loading", Earthq. Eng. Struct. Dyn., 8(3), 349-59.   DOI
48 Nagarajaiah, S., Reinhorn, A.M. and Constantinou, M.C. (2003), "Torsion in base-isolated structures with elastomeric isolation systems", J. Struct. Eng., 119(10), 2932-2951.   DOI
49 Pan, T.C., Kelly, J.M. (1984), "Coupled lateral-torsional response of base-isolated structures", Proceedings of the 8th World Conference, Earthq. Eng.
50 Rutenberg, A. and Eisenberger, M. (1984), "Seismic response of base isolated asymmetric shear buildings", Proceedings of the 8th World Conference, Earthq. Eng.
51 Ryan, K.L. and Chopra, A.K. (2004), "Estimation of seismic demands on isolators in asymmetric buildings using non- linear analysis", Earthq. Eng. Struct. Dyn., 33(3), 395-418.   DOI
52 Ryan, K.L. and Chopra, A.K. (2006), "Estimating beaing response in symmetric and asymmetric-plan isolated buildings with rocking and torsion", Earthq. Eng. Struct. Dyn., 35(8), 1009-1036.   DOI
53 Seguin, C.E., De La Llera, J.C. and Almazan, J.L. (2008), "Base-structure interaction of linearly isolated structures with lateral-torsional coupling", Eng. Struct., 30, 110-125.   DOI
54 Hejal, R. and Chopra, A.K. (1989c), "Earthquake analysis of a class of torsionally coupled buildings", Earthq. Eng. Struct. Dyn., 18(3), 305-323.   DOI
55 Hart, G.C., Di Julio, R.M., Jr. and Lew, M. (1975), "Torsional response of high-rise buildings", J. Struct. Div., 101(ST2), 397-416.
56 Hejal, R. and Chopra, A.K. (1989a), "Earthquake response of torsionally coupled frame buildings", J. Struct. Eng., 115(4), 834-851.   DOI
57 Hejal, R. and Chopra, A.K. (1989b), "Lateral -tosional coupling in earthquake response of frame buildings", J. Struct. Eng., 115(4), 852-867.   DOI
58 Hejal, R. and Chopra, A.K. (1989d), "Response spectrum analysis of class of torsionally-coupled buildings", J. Eng. Mech., 115(8), 1761-1781.   DOI
59 Hidalgo, P.A., Arias, A. and Cruz, E.F (1992), "A comparison of analysis provisions in seismic codes", Proceedings of the 10th World Conference, Earthq. Eng., 10, 5741-5746.
60 Hutchinson, G.L., Chandler, A.M. and Rady, M.A. (1993), "Effect of vertical distribution of mass and translational stiffness on dynamic eccentricities for a special class of multi-storey buildings", Bul. New Zealand Nat. Soc. Earthq. Eng., 26(1), 42-48.
61 Jiang, W., Hutchinson, G.L. and Chandler, A.M. (1993), "Definitions of static eccentricity for design of asymmetric shear buildings", Eng. Struct., 15(3), 167-178.   DOI   ScienceOn
62 Kan, C.L. and Chopra, A.K. (1977a), "Elastic earthquake analysis of a class of torsionally coupled buildings", J. Struct. Div., 103(4), 821-838.
63 Kan, C.L. and Chopra, A.K. (1977b), "Elastic earthquake analysis of torsionally coupled multi-storey buildings", Earthq. Eng. Struct. Dyn., 5(4), 395-412.   DOI
64 Ghersi, A., Marino, E.M. and Rossi, P.P. (2007), "Static versus modal analysis: influence on inelastic response of multi- storey asymmetric buildings", Bul. Earthq. Eng., 5, 511-532.   DOI
65 Fajfar, P., Marusic, D. and Perus, I. (2004), "Influence of ground motion intensity on the inelastic torsional response of asymmetric buildings", Proceedings of the 13th World Conference, Earthq. Eng.
66 Garcia, O., Islas, A. and Ayala, A.G. (2004), "Effect of the in-plan distribution of strength on the non-linear seismic response of torsionally coupled buildings", Proceedings of the 13th World Conference, Earthq. Eng.
67 Ghersi, A., Marino, E. and Rossi, P.P. (2000), "Inelastic response of multi-storey asymmetric buildings", Proceedings of the 12th World Conference, Earthq. Eng.
68 Karimiyan, S. Moghadam, A.S. and Vetr, M.G. (2013), "Seismic progressive collapse assessment of 3-story RC moment resisting buildings with different levels of eccentricity in plan", Earthq. Struct., 5(3), 277-296.   DOI   ScienceOn
69 Karimiyan, S., Moghadam, A.S., Karimiyan, M. and Kashan, A.H. (2013), "Seismic collapse propagation in 6-story RC regular and irregular buildings", Earthq. Struct., 5(6), 753-779.   DOI
70 Karimiyan, S., Kashan, A.H. and Karimiyan, M. (2014), "Progressive collapse vulnerability in 6-Story RC symmetric and asymmetric buildings under earthquake loads", Earthq. Struct., 6(5), 473-494.   DOI
71 Kosmopoulos, A.J. and Fardis, M.N. (2007), "Estimation of inelastic seismic deformations in asymmetric multistorey RC buildings", Earthq. Eng. Struct. Dyn., 36(9), 1209-1234.   DOI
72 Kyrkos, M.T. and Anagnostopoulos, S.A. (2011a), "An assessment of code designed, torsionally stiff, asymmetric steel buildings under strong eathgquake excitations", Earthq. Struct., 2(2),109-126.   DOI
73 Shook, D.A., Roschke, P.N., Lin, P.Y. and Loh, C.H. (2009), "Semi-active control of a torsionallyresponsive structure", Eng. Struct., 31, 57-68.   DOI
74 Seguin, C.E., Almazan, J.L. and De La Llera, J.C (2013), "Torsional balance of seismically isolated asymmetric structures", Eng. Struct., 46, 703-717.   DOI
75 Shakib, H. and Fuladgar, A. (2003), "Effect of vertical component of earthquake on the response of purefriction base-isolated asymmetric buildings", Eng. Struct., 25, 1841-1850.   DOI
76 Shimazaki, K. (2012), "Evaluation of seismic torsional response of base isolated buildings", Proceedings of the 15th World Conference, Earthq. Eng.
77 Tena-Colunga, A. and Gomez-Soberon, L. (2002), "Torsional response of base-isolated structures due to asymmetries in the superstructure", Eng. Struct., 24, 1587-1599.   DOI
78 Tena-Colunga, A. and Zambrana-Rojas, C. (2004), "Torsional response of base-isolated structures due to stiffness asymmetries of the isolation system", Proceedings of the 13th World Conference, Earthq. Eng.
79 Tena-Colunga, A. and Zambrana-Rojas, C. (2006), "Dynamic torsional amplifications of base-isolated structures with an eccentric isolation system", Eng. Struct., 28, 72-83.   DOI   ScienceOn
80 Tena-Colunga, A. and Escamilla_Cruz, J.L. (2007), "Torsional amplifications in asymmetric base-isolated structures", Eng. Struct., 29, 237-247.   DOI
81 Tena-Colunga, A. and Escamilla-Cruz, J.L. (2008), "Dynamic amplifications of torsionally unbalanced baseisolated structures", Proceedings of the 14th World Conference, Earthq. Eng.
82 Lin, J.L. and Tsai, K.C. (2008a), "Seismic analysis of two-way asymmetric building systems under bidirectional seismic ground motions", Earthq. Eng. Struct. Dyn., 37(2), 305-328.   DOI
83 Kan, C.L. and Chopra, A.K. (1977c), "Earthquake response of a class of torsionally coupled buildings", 6th World Conference, Earthq. Eng., 1211-1216.
84 Lam, N.T.K., Wilson, J.L. and Hutchinson, G.L. (1997), "Review of the torsional coupling of asymmetrical wall-frame buildings", Eng. Struct., 19(3), 233-246.   DOI
85 Lin, J.L. and Tsai, K.C. (2007a), "Simplified seismic analysis of asymmetric building systems", Earthq. Eng. Struct. Dyn., 36(4), 459-479.   DOI
86 Lin, J.L. and Tsai, K.C. (2009), "Modal parameters for the analysis of inelastic asymmetric-plan structures", Earthq. Spectra, 25(4), 305-328.
87 Lin, J.L. and Tsai, K.C. (2011), "Estimation of the seismic energy demands of two-way asymmetric-plan buildings systems", Bul. Earthq. Eng., 9(2), 603-621.   DOI
88 Lin, J.L., Tsai, K.C. and Chuang, M.C. (2012), "Understanding the trends in torsional effects in asymmetric-plan buildings", Bul. Earthq. Eng., 10, 955-965.   DOI
89 Makarios, T. and Anastasiadis, K. (1998a), "Real and fictitious elastic axes of multi-storey buildings: theory", Struct. Des. Tall Build., 7(1), 33-55.   DOI
90 Makarios, T. and Anastasiadis, K. (1998b), "Real and fictitious elastic axes of multi-storey buildings: applications", Struct. Des. Tall Build., 7(1), 57-71.   DOI
91 Makarios, T. (2005), "Optimum torsion axis to multistorey buildings by using the continuous model of the structure", Struct. Des. Tall Build., 14, 69-90.   DOI
92 Kyrkos, M.T. and Anagnostopoulos, S.A. (2012b), "Assessment of earthquake resistant design of eccentric, braced frame, steel buildings and proposal for possible improvements", Proceedings of the 15th World Conference, Earthq. Eng.
93 Kyrkos, M.T. and Anagnostopoulos, S.A. (2011b), "Improved earthquake resistant design of torsionally stiff asymmetric steel buildings", Earthq. Struct., 2(2), 127-147.   DOI
94 Kyrkos, M.T. and Anagnostopoulos, S.A. (2011c) "Improved earthquake resistant design of irregular steel buildings", Proceedings of the 6th European Workshop on the seismic behavior of irregular and complex structures, Haifa, Israel.
95 Kyrkos, M.T. and Anagnostopoulos, S.A. (2012a) "Earthquake resistant design of eccentric, braced frame, steel buildings for improved inelastic response", Proceedings of the STESSA 2012 (Behavior of steel structures in seismic areas), Santiago, Chile.
96 Kyrkos, M.T. and Anagnostopoulos, S.A. (2013a), "Improved earthquake resistant design of eccentric steel buildings", Soil Dyn. Earthq. Eng., 47, 144-156.   DOI
97 Kyrkos, M.T. and Anagnostopoulos, S.A. (2013b) "Eccentric steel buildings designed for uniform ductility demands under earthquake actions", Proceedings of the COMPDYN-13, Kos Island, Greece.
98 Marusic, D. and Fajfar, P. (2005), "On the inelastic sesimic response of asymmetric buildings under bi-axial excitation", Earthq. Eng. Struct. Dyn., 34(8), 943-963.   DOI
99 Stathopoulos, K.G. and Anagnostopoulos, S.A. (2000), "Inelastic earthquake response of buildings subjected to torsion", Proceedings of the 12th World Conference, Earthq. Eng.
100 Toyama, J., Shinozaki, Y., Inoue, T., Maseki, R., Nagashima, I., Takagi, M. and Kitagawa, Y. (2004), "An advanced base-isolation system for irregular building design", Proceeedings of the 13th World Confernce, Earthq. Eng.
101 Aguirre, J.J., Almazan, J.L. and Paul, C.J. (2013), "Optimal control of linear and nonlinear asymmetric structures by means of passive energy dampers", Earthq. Eng. Struct. Dyn., 42(3), 377-395.   DOI
102 Ahlawat, A.S. and Ramaswamy, A. (2002), "Multiobjective optimal absorber system fot torsionally coupled seismically excited structures", Eng. Struct., 25, 941-950.
103 Almazan, J.L. and De La Llera, J.C. (2009), "Torsional balance as new design criterion for asymmetric structures with energy dissipation devices", Earthq. Eng. Struct. Dyn., 38(12), 1421-1440.   DOI
104 Almazan, J.L., Espinoza, G. and Aguirre, J.J. (2012), "Torsional balance of asymmetric structures by means of tuned mass dampers", Eng. Struct., 42, 308-328.   DOI
105 Casciati, F., Rodellar, J. and Yildirim, U. (2011), "Active and semi-active control of structures: A review of recent advances", Proceedings of the EURODIN 2011, Louvain, Belgium.
106 Constantinou, M. (1994) "Principles of friction, viscoelastic, yielding steel and fluid viscous dampers: Properties and design", Passive and active structural vibration control in civil engineering, Soong and Constantinou, Eds. Dept. of Civil Eng., SUNY, Buffalo, USA.
107 De La Llera, J.C., Almazan, J.L., Vial, I., Ceballos, V. and Garcia, M. (2004), "Analytical and experimantal response of asymmetric structures with friction and viscoelastic dampers", Proceedings of the 13th World Conference, Earthq. Eng.
108 Ozhendekci, N. and Polat, Z. (2008), "Torsional irregularity of buildings", Proceedings of the 14th World Conference, Earthq. Eng., Beijing.
109 Makarios, T. (2008), "Practical calculation of the torsional stiffness radius of multistorey buildings", Struct. Des. Tall Build., 17, 39-65.   DOI
110 Marino, E.M. and Rossi, P.P. (2004), "Exact evaluation of the location of the optimum torsion axis", Struct. Des. Tall Build., 13(4), 277-290.   DOI
111 Rosenblueth, E. and Elorduy, J. (1969), "Responses of linear systems to certain transient disturbances", Proceedings of the 4th World Conference, Earthq. Eng.
112 Rosenblueth, E. and Contreras, H. (1977), "Approximate design for multi-component earthquakes", J. Eng. Mech., 103, 881-893.
113 Rutenberg, A., Hsu, T.I. and Tso, W.K. (1978), "Response spectrum techniques for asymmetric buildings", Earthq. Eng. Struct. Dyn., 6(5), 427-435.   DOI
114 Shiga, T. (1965), "Torsional vibration of multi-storied buildings", Proceedings of the 3rd World Conference, Earthq. Eng., 2, 569-584.
115 Tso, W.K. (1990), "Static eccentricity concept for torsional moment estimations", J. Struct. Div., 116(5), 1199-1212.   DOI
116 Wang, J.F., Lin, C.C., Lin, G.L. and Yang, C.H. (2013), "Story damage identification of irregular buildings based on earthquake records", Earthq. Spectra, 29(3).
117 Wittrick, W.H. and Horsington, R.W. (1979), "On the coupled torsional and sway vibrations of a class of shear buildings", Earthq. Eng. Struct. Dyn., 7(5), 477-490.   DOI
118 Yoon, Y.S. and Smith, B.S. (1995), "Assessment of translational-torsional coupling in asymmetric uniform wall-frame structures", J. Struct. Eng., 121(10), 1488-1496.   DOI
119 Stathopoulos, K.G. and Anagnostopoulos, S.A. (2004), "Earthquake induced inelastic torsion in asymmetric multistory buildings", Proceedings of the 13th World Conference, Earthq. Eng., Vancouver.
120 Stathopoulos, K.G. and Anagnostopoulos, S.A. (2002), "Inelastic earthquake induced torsion in buildings: results and conclusions from realistic models", Proceedings of the 12th European Conference, Earthq. Eng., London.
121 Stathopoulos, K.G. and Anagnostopoulos, S.A. (2005a), "Inelastic torsion of multistorey buildings under earthquake excitations", Earthq. Eng. Struct. Dyn., 34(12), 1449-1465.   DOI
122 Stathopoulos, K.G. and Anagnostopoulos, S.A. (2005b), "Effects of accidental design eccentricity on the inelastic earthquake response of asymmetric buildings", Proceedings of the 4th European Workshop on the Seismic Behaviour of Irregular and Complex Sructures, Thessaloniki, Greece.
123 Stathopoulos, K.G. and Anagnostopoulos, S.A. (2006), "Importance of accidental design eccentricity for the inelastic earthquake response of buildings", Proceedings of the 13th European Conference, Earthq. Eng.
124 Stathopoulos, K.G. and Anagnostopoulos, S.A.(2007), "Inelastic seismic response of asymmetric one-story steel buildings", Proceedings of the Compdyn 2007, Eccomas Thematic Conference on Composition, Meth. Struct. Dyn. Earthq. Eng., Rethymno, Greece.
125 Stathopoulos, K.G. and Anagnostopoulos, S.A. (2010) "Accidental design eccentricity: Is it important for the inelastic response of buildings to strong earthquakes?", Soil Dyn. Earthq. Eng., 30, 782-797.   DOI   ScienceOn
126 Tremblay, R. and Poncet, L. (2006), "Seismic performance of concentrically braced steel frames in multistory buildings with mass irregularity", J. Struct. Eng., 131(9), 1363-1375.
127 Goel, R.K. (2000a), "Seismic behaviour of asymmetric buildings with supplemental damping", Earthq. Eng. Struct. Dyn., 29(4), 461-480.   DOI
128 De La Llera, J.C., Almazan, J.L. and Vial, I. (2005), "Torsional balance of plan-asymmetric structures with frictional dampers: analytical results", Earthq. Eng. Struct. Dyn., 34(9), 1089-1108.   DOI
129 Fujii, K. (2008), "Nonlinear static procedure for reinforced concrete asymmetric buildings with linear viscous dampers", Proceedings of the 14th World Confernce, Earthq. Eng.
130 Garcia, M., De La Llera, J.C., Almazan, J.L. (2007), "Torsional balance of plan asymmetric structures with viscoelastic dampers", Eng. Struct., 29, 914-932.   DOI
131 Goel, R.K. (2000b), "Passive control of earthquake-induced vibrations in asymmetric buildings", Proceedings of the 12th World Confernece, Earthq. Eng.
132 Goel, R.K. and Booker, C.A. (2001), "Effects of supplemental viscous damping on inelastic seismic response of asymmetric systems", Earthq. Eng. Struct. Dyn., 30(4), 411-430.   DOI
133 Goel, R.K. (2001), "Simplified analysis of asymmetric structures with supplemental damping", Earthq. Eng. Struct. Dyn., 30(9), 1399-1416.   DOI
134 Goel, R.K. (2004), "Seismic response control of irregular structures using nonlinear dampers", Proceedings of the 13th World Conference, Earthq. Eng.
135 Goel, R.K. (2005), "Seismic response of linear and non-linear asymmetric systems with non-linear fluid viscous dampers", Earthq. Eng. Struct. Dyn., 34(7), 825-846.   DOI
136 Huo, L.S. and Li, H.N. (2004), "Torsionally coupled response control of structures using circular tuned liquid columh dampers", Eng. Mech., 22(2), 124-131.
137 Bozorgnia, Y. and Tso, W.K. (1986), "Inelastic earthquake response of asymmetric structures", J. Struct. Div., 112(2), 383-400.   DOI
138 Zarate, G. and Ayala, A.G. (2004), "Validation of single storey models for the evaluation of the seismic performance of multi-storey asymmetric buildings", Proceedings of the 13th World Conference, Earthq. Eng.
139 Annigeri, S., Mittal, A.K. and Jain, A.K. (1996), "Uncoupled frequency ratio in asymmetric buildings", Earthq. Eng. Struct. Dyn., 25(8), 871-881.   DOI
140 Bensalah, M.D., Bensaibi, M. and Modaressi, A. (2012), "Assessment of the torsional effect in asymmetric buildings under seismic load", Proceedings of the 15th World Conference, Earthq. Eng.
141 Bruneau, M. and Mahin, S.A. (1988), "Prediction of the inelastic response of torsionally coupled systems subjected to earthquake excitation", Proceedings of the 9th World Conference, Earthq. Eng., Association for earthquake disaster prevention, Japan.
142 Bruneau, M. and Mahin, S.A. (1990), "Normalizing inelastic seismic response of structures having eccentricities in plan", J. Struct. Eng., 116(12), 3358-3379.   DOI
143 Bruneau, M. (1992), "A proposed simple model for the study of seismic inelastic torsional coupling", Proceedings of the 10th World Conference, Earthq. Eng., 7, 3875-80.
144 Bugeja, M.N., Thambiratnam, D.P. and Brameld, G.H. (1999), "The influence of stiffness and strength eccentricities on the inelastic earthquake response of asymmetric structures", Eng. Struct., 21, 856-863.   DOI
145 Chandler, A.M. and Duan, X.N. (1990), "Inelastic torsional behaviour of asymmetric buildings under severe earthquake shaking", Struct. Eng. Review, 2, 141-159.
146 Ghersi, A., Marino, E. and Rossi, P.P. (1999), "From one-story to multi-story systems: conceptual differences and problems", Proceedings of the 2nd European Workshop Seismic Behaviour of Asymmetric and Setback Structures, Instabul, Turkey.
147 Anagnostopoulos, S.A., Alexopoulou, C. and Stathopoulos, K.G. (2008), "Are results for inelastic torsion in buildings based on simplified, one-storey, shear beam models, applicable to actual multistory buildings?", Proceedings of the 5th European Workshop on the Seismic behaviour of irregular and complex structures, Catania, Italy.
148 Anagnostopoulos, S.A., Alexopoulou, C. and Stathopoulos, K.G. (2009), "An answer to a persisting controversy in earthquake resistant design of asymmetric buildings for torsion", Proceedings of the Compdyn 2009, Rhodos, Greece.
149 Anagnostopoulos, S.A., Alexopoulou, C. and Stathopoulos, K. (2010) "An answer to an important controversy and the need for caution when using simple models to predict inelastic earthquake response of buildings with torsion", Earthq. Eng. Struct. Dyn., 39, 521-540.
150 Muslimaj, B. and Tso, W.K. (2001), "A strength distribution criterion for minimizing torsonal response of asymmetric wall-type systems", Earthq. Eng. Struct. Dyn., 31(1), 99-120.   DOI
151 Tso, W.K. and Muslimaj, B. (2003), "A yield displacement distribution-based approach for strength assignment to lateral force resisting elements having strength dependent stiffness", Earthq. Eng. Struct. Dyn., 32(15), 2319-2351.   DOI
152 Aviles, J. and Suarez, M. (2006), "Natural and accidental torsion in one-storey structures on elastic foundation under non-vertically incident SH-waves", Earthq. Eng. Struct. Dyn., 35(7), 829-850.   DOI
153 Lavan, O. and Amir, O. (2014), "Simultaneous topology and sizing optimization of viscous dampers in seismic retrofitting of 3D irregular frame structures", Earthq. Eng. Struct. Dyn., 43(9), 1307-1324.   DOI
154 Kim, J. and Bang, S. (2002), "Optimum distribution of added viscoelastic dampers for mitigation of torsional responses of plan-wise asymmetric structures", Eng. Struct., 24, 1257-1269.   DOI   ScienceOn
155 Landi, L., Diotalleli, P.P. and Castellari, G. (2013), "On the design of viscous dampers for the rehabilitation of plan-asymmetric buildings", J. Earthq. Eng., 17(8).
156 Lavan, O. and Levy, R. (2006), "Optimal peripheral drift control of 3D irregular framed structures using supplemental viscous dampers", J. Earthq. Eng., 10(6), 903-923.   DOI
157 Li, C. and Qu W. (2005), "Optimum properties of multiple tuned mass dampers for reduction of translational and torsional response of structures subject to ground accelaration", Eng. Struct., 28, 472-494.
158 Lin, C.C., Ueng, J.M., Huang, T.C. (1999), "Seismic response reduction of irregular buildings using passive tuned mass dampers", Eng. Struct., 22, 513-524.
159 Lin, W.H. and Chopra, A.K. (2001), "Understanding and predicting effects of supplemental viscous damping on seismic response of asymmetric one-storey systems", Earthq. Eng. Struct. Dyn., 30(10), 1475-1494.   DOI   ScienceOn
160 Lin, W.H. and Chopra, A.K. (2003a), "Asymmetric one-storey elastic systems with non-linear viscous and viscoelastic dampers: Earthquake response", Earthq. Eng. Struct. Dyn., 32(4), 555-577.   DOI
161 Lin, W.H. and Chopra, A.K. (2003b), "Asymmetric one-storey elastic systems with non-linear viscous and viscoelastic dampers: Simplified analysis and supplemental damping system design", Earthq. Eng. Struct. Dyn., 32(4), 579-596.   DOI
162 Chandler, A.M., Correnza, J.C. and Hutchinson, G.L. (1995), "Influence of accidental eccentricity on inelastic seismic torsional effects in buildings", Eng. Struct., 17(3), 167-178.   DOI
163 Chandler, A.M. and Duan, X.N. (1991), "Evaluation of factors influencing the inelastic seismic performance of torsionally asymmetric buildings", Earthq. Eng. Struct. Dyn., 20, 87-95.   DOI
164 Chandler, A.M., Hutchinson, G.L. and Jiang, W. (1991), "Inelastic torsional response of buildings to the 1985 Mexican earthquake: a parametric study", Soil Dyn. Earthq. Eng., 10(8), 429-439.   DOI
165 Chandler, A.M., Correnza, J.C. and Hutchinson, G.L. (1994), "Period-dependent effects in seismic torsional response of code systems", J. Struct. Div., 120(12), 3418-3434.   DOI
166 Chandler, A.M., Correnza, J.C. and Hutchinson, G.L. (1996), "Seismic torsional provisions: Influence on element energy dissipation", J. Struct. Eng., 122(5), 494-500.   DOI
167 Chandler, A.M. and Duan, X.N. (1997), "Performance of asymmetric code-designed buildings for serviceability and ultimate limit states", Earthq. Eng. Struct. Dyn., 26(7), 717-735.   DOI
168 Correnza, J.C., Hutchinson, G.L. and Chandler, A.M. (1994), "Effect of transverse load-resisting elements on inelastic earthquake response of eccentric-plan buildings", Earthq. Eng. Struct. Dyn., 23(1), 75-90.   DOI
169 Correnza, J.C., Hutchinson, G.L. and Chandler, A.M. (1995), "Seismic response of flexible-edge elements in code-designed torsionally unbalanced structures", Eng. Struct., 17(3), 158-166.   DOI
170 De Stefano, M. and Rutenberg, A. (1996), "Seismic instability and the force reduction factor of yielding structures", Proceedings of the 11th World Conference, Earthq. Eng.
171 De La Colina, J. and Almeida, C. (2004), "Probabilistic study on accidental torsion of low-rise buildings", Earthq. Spectra, 20(1), 25-41.   DOI
172 Chandler, A.M., Correnza, J.C. and Hutchinson, G.L. (1995), "Influence of accidental eccentricity on inelastic seismic torsional effects in buildings", Eng. Struct., 17(3), 167-178.   DOI
173 Chopra, A.K. and De La Llera, J.C. (1996), "Accidental and natural torsion in earthquake response and design of buildings", Proceedings of the 11th World Conference, Earthq. Eng. Research Center, University of California.
174 DeBock, D.J., Liel, A.B., Haselton, C.B., Hooper, J.D. and Henige, R.A. (2014), "Importance of seismic design accidental torsion requirements for building collapse capacity", Earthq. Eng. Struct. Dyn., 43(6), 831-850.   DOI
175 De La Colina, J., Benitez, B. and Ruiz, S.E. (2011), "Accidental eccentricity of story shear for low-rise office buildings", J. Struct. Eng., 137(4), 513-520.   DOI
176 De La Llera, J.C. and Chopra, A.K. (1992), "Evaluation of code accidental torsion provisions using earthquake records from three nominally symmetric-plan buildings", EERC Report No. UCB/EERC-92/09, University of California, Berkeley, California, US.
177 De La Llera, J.C. and Chopra, A.K. (1994a), "Evaluation of code accidental-torsion provisions from building records", J. Struct. Eng., 120(2), 597-616.   DOI
178 De La Llera, J.C. and Chopra, A.K. (1994b), "Accidental torsion in buildings due to stiffness uncertainty", Earthq. Eng. Struct. Dyn., 23(2), 117-136.   DOI
179 De La Llera, J.C. and Chopra, A.K. (1994c), "Using accidental eccentricity in code-specified static and dynamic analyses of buildings", Earthq. Eng. Struct. Dyn., 23(9), 947-967.   DOI
180 Lin, J.L. and Tsai, K.C. (2007b), "Simplified seismic analysis of one-way asymmetric elastic systems with supplemental damping", Earthq. Eng. Struct. Dyn., 36(6), 783-800.   DOI
181 Lin, J.L. and Tsai, K.C. (2008b), "Seismic analysis of non proportionally damped two-way asymmetric elastic buildings under bi-directional seismic ground motions", J. Earthq. Eng., 12, 1139-1156.   DOI
182 Lin, J.L. and Tsai, K.C. (2008c), "Time-domain modal analysis of non-proportionally damped two-way asymmetric elastic buildings", Proceedings of the 14th World Conference, Earthq. Eng.
183 Lin, J.L., Tsai, K.C. and Yu, Y.J. (2010a), "Coupled tuned mass dampers for the seismic control of asymmetric-plan buildings", Earthq. Spectra, 26(3), 749-778.   DOI
184 Lin, C.C., Chang, C.C. and Wang, J.F. (2010b), "Active control of irregular buildings considering soilstructure interaction effects", Soil Dyn. Eathq. Eng., 30, 98-109.   DOI   ScienceOn
185 Lin, J.L., Tsai, K.C. and Yu, Y.J. (2011), "Bi-directional coupled tuned mass dampers for the seismic response control of two-way asymmetric-plan buildings", Earthq. Eng. Struct. Dyn., 40(6), 675-690.   DOI
186 Lin, J.L., Bui, M.T. and Tsai, K.C. (2014), "An energy-based approach to the generalized optimal locations of viscous dampers in two-way asymmetrical buildings", Earthq. Spectra, 30(2), 867-889.   DOI
187 Liu, S.C., Yang, J.N. and Samali, B. (1984), "Control of coupled lateral-torsional motion of buildings under earthquake excitations", Proceedings of the 8th World Confernce, Earthq. Eng.
188 Lumantarna, E., Lam, N. and Wilson, J. (2013), "Displacement-controlled behavior of asymmetrical singlestory building models", J. Earthq. Eng., 17(6), 902-917.   DOI
189 Escobar, J.A. (1996), "Seismic torsion in non-linear nominally symmetric structures due to random properties", 11st World Conference on Earthquake Engineering, Acapulco Gro., Mexico.
190 De Stefano, M. and Rutenberg, A. (1997), "A comparison of the present SEAOC/UBC torsional provisions with the old ones", Eng. Struct., 19(8), 655-664.   DOI
191 Escobar, J.A. and Ayala, A.G. (1998), "Yielding seismic response of code-designed single storey asymmentric structures", Earthq. Eng. Struct. Dyn., 27(6), 525-541.   DOI
192 Ghersi, A. and Rossi, P.P. (2000), "Formulation of design eccentricity to reduce ductility demand in asymmetric buildings", Eng. Struct., 22, 857-871.   DOI
193 Goel, R.K. and Chopra, A.K. (1990), "Inelastic seismic response of one-story, asymmetric-plan systems: effects of stiffness and strength distribution", Earthq. Eng. Struct. Dyn., 19(7), 949-970.   DOI
194 Irvine, H.M. and Kountouris, G.E. (1980), "Peak ductility demands in simple torsionally unbalanced buildings. Models subjected to earthquake excitation", Proceedings of the 7th World Conference, Earthq. Eng., Istanbul, Turkey.
195 Kan, C.L. and Chopra, A.K. (1981a), "Simple model for earthquake response studies of torsionally coupled buildings", J. Eng. Mech., 107(5), 935-951.
196 Kan, C.L. and Chopra, A.K. (1981b), "Torsional coupling and earthquake response of simple elastic and inelastic systems", J. Struct. Div., 107(8), 1569-1588.
197 Mittal, A.K. and Jain, A.K. (1995), "Effective strength eccentricity concept for inelastic analysis of asymmetric structures", Earthq. Eng. Struct. Dyn., 24, 69-84.   DOI
198 Lin, W.H., Chopra, A.K. and De La Llera, J.C. (2001), "Accidental torsion in buildings:Analysis versus earthquake motions", J. Struct. Eng., 127(5), 475-481.   DOI
199 De La Llera, J.C. and Chopra, A.K. (1995), "Estimation of accidental torsion effects for seismic design of building", J. Struct. Eng., 121(1), 102-114.   DOI
200 Dimova, S.L. and Alashki, I. (2003), "Seismic design of symmetric structures for accidental torsion", Bul. Earthq. Eng., 1, 303-320.   DOI
201 Pekau, O.A. and Guimond, R. (1988), "Accidental torsion in yielding symmetric structures", Proceedings of the 9th World Conference, Earthq. Eng.
202 Pekau, O.A. and Guimond, R. (1990), "Accidental torsion in yielding symmetric structures", Eng. Struct. 12(2), 98-105.   DOI
203 Ramadan, O.M.O., Mehanny, S.S.F. and Mostafa, A. (2008), "Revisiting the 5% accidental eccentricity provision in seismic design codes for multi-story buildings", Proceedings of the 14th World Conference, Earthq. Eng.
204 Shakib, H. and Tohidi, R.Z. (2002), "Evaluation of accidental eccentricity in buildings due to rotational component of earthquake", J. Earthq. Eng., 6(4), 431-445.   DOI
205 Stathopoulos, K.G. and Anagnostopoulos, S.A. (2005b), "Effects of accidental design eccentricity on the inelastic earthquake response of asymmetric buildings", Proceedings of the 4th European Workshop on the Seismic Behaviour of Irregular and Complex Sructures, Thessaloniki, Greece.
206 Stathopoulos, K.G. and Anagnostopoulos, S.A. (2006), "Importance of accidental design eccentricity for the inelastic earthquake response of buildings", Proceedings of the 13th European Conference, Earthq. Eng.
207 Palazzo, B., Petti, L. and De Iuliis, M. (2004), "Torsional seismic response control of asymmetric-plan systems by using viscous dampers", Eng. Struct., 30(11), 3377-3388.   DOI
208 Mansoori, M.R. and Moghagam, A.S. (2008), "Effects of damper distribution in controlling multiple torsional response parameters of asymmetric structures", Proceedings of the 14th World Confernce, Earthq. Eng.
209 Mevada, S.V. and Jangid, R.S. (2012), "Seismic response for torsionally coupled system with semi-active variable dampers", J. Earthq. Eng., 16, 1043-1054.   DOI
210 Murnal, P. and Sinha, R. (2004), "Behaviot of torsionally coupled structures with variable frequency pendulum isolator", J. Struct. Eng., 130(7), 1041-1054.   DOI
211 Pekau, O.A. and Guimond, R. (1991), "Controlling seismic response of eccentric structures by friction dampers", Earthq. Eng. Struct. Dyn., 20(6), 505-522.   DOI
212 Pekau, O.A. and Mastrangelo, E. (1992), "Seismic performance of friction damped asymmetric structures", Proceedings of the 10th World Confernce, Earthq. Eng.
213 Pekau, O.A., Dasgupta, B. and Bedair, H. (2000), "Improved deployment of friction dampers in asymmetric multi-story buildings", Proceedings of the 12th World Confernce, Earthq. Eng., Auckland, New Zealand.
214 Petti, L. and De Iuliis, M. (2008), "Torsional seismic response control of asymmetric-plan systems by using viscous dampers", Eng. Struct., 30, 3377-3388.   DOI
215 Petti, L. and De Iuliis, M. (2009), "Robust design of a single tuned mass damper for controlling torsonal response of asymmetric-plan systems", J. Earthq. Eng., 13, 108-128.   DOI
216 Rutenberg, A., Eisenberger, M. and Shohet, G. (1992b), "Inelastic seismic response of code designed single storey asymmetric structures", Eng. Struct., 14(2), 91-102.   DOI
217 Moghadam, A.S. and Tso, W.K. (2000), "Extension of Eurocode 8 torsional provisions to multi-storey buildings", J. Earthq. Eng., 4(1), 25-41.   DOI
218 Muslimaj, B. and Tso, W.K. (2001), "A strength distribution criterion for minimizing torsonal response of asymmetric wall-type systems", Earthq. Eng. Struct. Dyn., 31(1), 99-120.   DOI
219 Rutenberg, A., Benbenishti, A. and Pekau, O. (1992a), "Nonlinear seismic behaviour of code-designed eccentric systems", Proceedings of the 10th World Conference, Earthq. Eng.
220 Tso, W.K. and Sadek, A.W. (1985), "Inelastic seismic response of simple eccentric strucrures", Earthq. Eng. Struct. Dyn., 13(2), 255-269.   DOI
221 Tso, W.K. and Ying, H. (1990), "Additional seismic inelastic deformation caused by structural asymmetry", Earthq. Eng. Struct. Dyn., 19(2), 243-258.   DOI
222 Tso, W.K. and Ying, H. (1992), "Lateral strength distribution specification to limit additional inelastic deformation of torsionally unbalanced structures", Eng. Struct., 14(4), 263-277.   DOI
223 Tso, W.K. and Bozorgnia, Y. (1986), "Effective eccentricity for inelastic seismic response of buildings", Earthq. Eng. Struct. Dyn., 14(3), 413-427.   DOI
224 Tso, W.K. and Zhu, T.J. (1992a), "Strength distribution for torsionally unbalanced structures", Proceedings of the 10th World Conference, Earthq. Eng., 7, 3865-3868.
225 Tso, W.K. and Zhu, T.J. (1992b), "Design of torsionally unbalanced structural systems based on code provisions I: Ductility demand", Earthq. Eng. Struct. Dyn., 21(7), 609-627.   DOI
226 Bahmani, P., Lindt, J.W. and Dao, T.N. (2014), "Displacement-based design of buildings with torsion: theory and verification", J. Struct. Eng., 140(6).
227 Stathopoulos, K.G. and Anagnostopoulos, S.A. (2010), "Accidental design eccentricity: Is it important for the inelastic response of buildings to strong earthquakes?", Soil Dyn. Earthq. Eng., 30, 782-797.   DOI   ScienceOn
228 Wong, C.M. and Tso, W.K. (1994), "Inelastic seismic response of torsionally unbalanced systems designed using elastic dynamic analysis", Earthq. Eng. Struct. Dyn., 23(7), 777-798.   DOI
229 Aziminejad, A., Moghadam, A.S. and Tso, W.K. (2008), "A new methodology for designing multi-story asymmetric buildings", Proceedings of the 14th World Conference, Earthq. Eng., Beijing, China.
230 Bertero, R.D. (1995), "Inelastic torsion for preliminary seismic design", J. Struct. Eng., 121(8), 1183-1189.   DOI
231 Chandler, A.M. and Duan, X.N. (1993), "A modified static procedure for the design of torsionally unbalanced multi- storey frame buildings", Earthq. Eng. Struct. Dyn., 22(5), 447-462.   DOI
232 Crisafulli, F., Reboredo, A. and Torrisi, G. (2004), "Consideration of torsional effects in the displacement control of ductile buildings", Proceedings of the 13th World Conference, Earthq. Eng.
233 De La Llera, J.C. (2000), "Some fundamental aspects of torsionally coupled structures", Proceedings of the 12th World Conference, Earthq. Eng., Auckland, New Zealand.
234 De Stefano, M., Faella, G. and Ramasco, R. (1993), "Inelastic response and design criteria of plan-wise asymmetric system", Earthq. Eng. Struct. Dyn., 22(3), 245-259.   DOI
235 Spencer, Jr. B.F. and Nagarajaiah, S. (2003), "State of the art of structural control", J. Struct. Eng., ASCE, 129, 845-856.   DOI
236 Shook, D.A., Roschke, P.N., Lin, P.Y. and Loh, C.H. (2009), "Semi-active control of a torsionallyresponsive structure", Eng. Struct., 31, 57-68.   DOI
237 Singh, M.P., Singh, S. and Moreschi, L.M. (2002), "Tuned mass dampers for response control of torsional buildings", Earthq. Eng. Struct. Dyn., 31(4), 749-769.   DOI
238 Soong, T.T. and Spencer, Jr. B.F. (2000) "Active, semi-active and hybrid control of structures", Proceedings of the 12 World Conference, Earthq. Eng.
239 Symans, M.D., Charney, F.A., Whittaker, A.S., Constantinou, M.C., Kircher, C.A., Johnson, M.W. and McNamara, R.J. (2008), "Energy dissipation systems for seismic applications: current practice and recent developments", J. Struct. Eng., 134(1), 3-21.   DOI
240 Vial, I.J., De La Llera, J.C., Almazan, J.L. and Ceballos, V. (2006), "Torsional balance of plan-asymmetric structures with frictional dampers: experimental results", Earthq. Eng. Struct. Dyn., 35(15), 1875-1898.   DOI   ScienceOn
241 Yoshida, O. and Dyke, S.J. (2005), "Response control of full scale irregular buildings using magnetorheological dampers", J. Struct. Eng., 131(5), 734-742.   DOI   ScienceOn
242 MOC-2008, Manual of Civil Structures, Mexico.
243 ASCE 7-05 (2005), Minimum design loads for buildings and other structures.
244 EN 1998-1 (2004), Eurocode 8: Design of structures for earthquake resistance. Part I : General rules, seismic actions and rules for buildings.
245 International Building Code (IBC) (2012), International Code Council Inst., USA.
246 National Building Code of Canada (NBCC) (2005), National Research Council of Canada.
247 N.Z.S. 1170.5 (2004), Stuctural design actions, Part 5: Earthquake actions, New Zealand.
248 Chandler, A.M., Duan, X.N. and Rutenberg, A. (1996), "Seismic torsional response: Assumptions, controversies and research progress", Europ. Earthq. Eng., 10(1), 37-51.
249 Correnza, J.C., Hutchinson, G.L. and Chandler, A.M. (1992), "A review of reference models for assessing inelastic seismic torsional effects in buildings", Soil Dyn. Earthq. Eng., 11(8), 465-484.   DOI
250 Cosenza, E., Manfredi, G. and Realfonzo, R. (2000), "Torsional effects and regularity conditions in RC buildings", Proceedings of the 12th World Conference on Earthquake Engineering, Auckland, New Zealand.
251 De Stefano, M. and Pintucchi, B. (2008), "A review of research on seismic behaviour of irregular building structures since 2002", Bul. Earthq. Eng., 6, 285-308.   DOI
252 Rutenberg, A. (1992), "Nonlinear response of asymmetric building structures and seismic codes: A state of the art", Europ.Earthq. Eng., 6(2), 3-19.
253 De Stefano, M., Faella, G. and Ramasco, R. (1992), "Inelastic spectra for eccentric systems", Proceedings of the 10th World Conference, Earthq. Eng.
254 Chandler, A.M. and Hutchinson, G.L. (1992), "Effect of structural period and ground motion parameters on the earthquake response of asymmetric buildings", Eng. Struct., 14(6), 354-360.   DOI
255 Chandler, A.M. and Duan, X.N. (1994), "On the performance of inelastically responding asymmetric structures designed by the modal response spectrum method of NZS 4203:1992", Bul. NZ. Natl. Soc. Earthq. Eng., 27(2), 96-106.
256 Chopra, A.K. and Goel, R.K. (1991), "Evaluation of torsional provisions in seismic codes", J. Struct. Div., 117(12), 3762-3782.   DOI
257 De Stefano, M., Faella, G. and Ramasco, R. (1993), "Inelastic response and design criteria of plan-wise asymmetric system", Earthq. Eng. Struct. Dyn., 22(3), 245-259.   DOI
258 Goel, R.K. and Chopra, A.K. (1990), "Inelastic seismic response of one-story, asymmetric-plan systems: Effects of stiffness and strength distribution", Earthq. Eng. Struct. Dyn., 19(7), 949-970.   DOI
259 Goel, R.K. and Chopra, A.K. (1991a), "Effects of plan asymmetry in the inelastic seismic response of onestory systems", J. Struct. Eng., 117(5), 1492-1513.   DOI
260 Goel, R.K. and Chopra, A.K. (1991b), "Inelastic seismic response of one-storey, asymmetric-plan systems: Effects of system parameters and yielding", Earthq. Eng. Struct. Dyn., 20(3), 201-222.   DOI
261 Goel, R.K. and Chopra, A.K. (1992), "Evaluation of seismic code provisions for asymmetric-plan systems", Proceedings of the 10th World Conference, Earthq. Eng., Madrid, Spain.
262 Goel, R.K. and Chopra, A.K. (1994), "Dual-level approach for seismic design of asymmetric-plan buildings", J. Struct. Eng., 120(1), 161-179.   DOI
263 Duan, X.N. and Chandler, A.M. (1997), "An optimized procedure for seismic design of torsionally unbalanced structures", Earthq. Eng. Struct. Dyn., 26, 737-757.   DOI
264 Ghersi, A. and Rossi, P.P. (1998), "Behavior of in plan irregular subjected to bi-directional ground motions", Proceedings of the 11th European Conference, Earthq. Eng.
265 Ghersi, A., Marino, E.M. and Rossi P.P. (2007), "Static versus modal analysis: influence on inelastic response of multi- storey asymmetric buildings", Bul. Earthq. Eng., 5(4), 511-532.   DOI
266 Kyrkos, M.T. and Anagnostopoulos, S.A. (2011), "Improved earthquake resistant design of torsionally stiff asymmetric steel buildings", Earthq. Struct., 2(2), 127-147.   DOI
267 Kyrkos, M.T. and Anagnostopoulos, S.A. (2013), "Improved earthquake resistant design of eccentric steel buildings", Soil Dyn. Earthq. Eng., 47, 144-156.   DOI
268 Mittal, A.K. and Jain, A.K. (1995), "Effective strength eccentricity concept for inelastic analysis of asymmetric structures", Earthq. Eng. Struct. Dyn., 24, 69-84.   DOI
269 Muslimaj, B. and Tso, W.K. (2005). "A Design- Oriented approach to strength distribution in single-strory asymmetric systems with elements having strength-dependent stiffeness", Earthq. Spectra, 21(1), 197-212.   DOI
270 Paulay, T. (1996), "Seismic design for torsional response of ductile buildings", Bul. NZ Natl. Soc. Earthq. Eng., 29(3), 178-198.
271 Paulay, T. (1997a), "A review of code provisions for torsional seismic effects in buildings", Bul. NZ Natl. Soc. Earthq. Eng., 30(3), 252-263.
272 Alexander, N.A. (2007), "The role of phase difference components of ground motions in the torsional response of asymmetric buildings", Earthq. Eng. Struct. Dyn., 36(10), 1385-1406.   DOI
273 Rutenberg, A. and De Stefano, M. (1997), "On the seismic performance of yielding asymmetric multistorey buildings: A review and a case study", Seismic Design Methodologies for the Next Generation of Codes, Eds. Fajfar and Krawinkler, ISBN 90.54.10.928.9.
274 Rutenberg, A. (1998), "EAEE Task Group (TG) 8: Behavior of irregular and complex structures-State of the art report: Seismic nonlinear response of code-designed asymmetric structures", Proceedings of the 11th European Conference on Earthquake Engineering.
275 Rutenberg, A. (1998), "EAEE task group (TG) 8: Behavior of irregular and complex structures - Asymmetric structures-Progress since 1998", Proceedings of 12th European Conference on Earthquake Engineering, Paper No. 832.
276 Castellani, A. and Boffi, G. (1986), "Rotational components of the surface ground motion during an earthquake", Earthq. Eng. Struct. Dyn., 14, 751-767.   DOI
277 De La Llera, J.C. and Chopra, A.K. (1994d), "Accidental torsion in buildings due to base rotational excitation", Earthq. Eng. Struct. Dyn., 23(9), 1003-1022.   DOI
278 Hahn, G.D. and Liu, X. (1994), "Torsional response of unisymmetric buildings to incoherent ground motions", J. Struct. Eng., 120(4), 1158-1181.   DOI
279 Hao, H. and Duan, X.N. (1995), "Seismic response of asymmetric structures to multiple ground motions", J. Struct. Eng., 121(11), 1557-1564.   DOI
280 Hao, H. and Duan, X. (1996), "Multiple excitation effects on response of symmetric buildings", Eng. Struct., 18(9), 732-740.   DOI
281 Humar, J. and Kumar, P. (2004), "Review of code provisions to account for earthquake induced torsion", Proceedings of the 13th World Conference, Earthquake Engineering.
282 Goel, R.K. and Chopra, A.K. (1994), "Dual-level approach for seismic design of asymmetric-plan buildings", J. Struct. Div., 120(1), 161-179.   DOI
283 Humar, J.M. and Fazileh, F. (2010), "Discussion of "Seismic behavior of single-story asymmetric-plan buildings under uniaxial excitation", (Eds.) A. Lucchini, G. Monti and S. Kunnath", Earthq. Eng. Struct. Dyn., 39, 705-708.
284 Humar, J. and Kumar, P. (2000), "A new Look at the Torsion Design Provisions in Seismic Building Codes", Proceedings of the 12th World Conference on Earthquake Engineering.
285 Jiang, W., Hutchinson, G.L. and Wilson, J.L. (1996), "Inelastic torsional coupling of building models", Eng. Struct, 18(4), 228-300.
286 Lin, J.L. and Tsai, K.C. (2009), "Modal parameters for the analysis of inelastic asymmetric-plan structures", Earthq. Spectra, 25(4), 821-849.   DOI
287 Lucchini, A., Monti, G. and Kunnath, S. (2009), "Seismic behavior of single-story asymmetric-plan buildings under uniaxial excitation", Earthq. Eng. Struct. Dyn., 38, 1053-1070.   DOI
288 Lucchini, A., Monti, G. and Kunnath, S. (2010), Authors' reply-Discussion by Humar and Fazileh of "Seismic behavior of single-story asymmetric-plan buildings under uniaxial excitation", Earthq. Eng. Struct. Dyn., 39, 941-944-1070.
289 Muslimaj, B. and Tso, W.K. (2004), "Desirable strength distribution for asymmetric structures with strength-stiffeness dependent elements", J. Earthq. Eng., 8(2), 231-248.   DOI
290 Pekau, O.A. and Syamal, P.K. (1985), "Torsional instability in hysteretic structures", J. Eng. Mech., 111(4), 512-528.   DOI
291 Paulay, T. (2000), "A simple displacement compatibility-based seismic design strategy for reinforced concrete buildings", Proceedings of the 12th World Conference, Earthq. Eng.
292 Paulay, T. (1997b), "Displacement-based design approach to earthquake-induced torsion in ductile buildings", Eng. Struct., 19(9), 699-707.   DOI
293 Paulay, T. (1997c), "Are Existing Seismic Torsion Provisions Achieving the Design Aims?", Earthq. Spectra, 13(2), 259-279.   DOI
294 Paulay, T. (1998), "Torsional mechanisms in ductile building systems", Earthq. Eng. Struct. Dyn., 27(10), 1101-1121.   DOI
295 Paulay, T. (2001), "Some design principles relevant to torsional phenomena in ductile buildings", J. Earthq. Eng., 5(3), 273-308.   DOI
296 Sommer, A. and Bachmann, H. (2005), "Seismic behavior of asymmetric RC wall buildings: principles and new deformation-based design method", Earthq. Eng. Struct. Dyn., 34(2), 101-124.   DOI
297 Tso, W.K. and Muslimaj, B. (2003), "A yield displacement distribution-based approach for strength assignment to lateral force resisting elements having strength dependent stiffness", Earthq. Eng. Struct. Dyn., 32(15), 2319-2351.   DOI
298 Bousias, S.N., Fardis, M.N., Spathis, A.L. and Kosmopoulos, A.J. (2007), "Pseudodynamic response of torsionally unbalanced two-story test testure", Earthq. Eng. Struct. Dyn., 36(8), 1065-1087.   DOI
299 De-la_Colina, J., Acuna, Q., Hernandez, A. and Valdes, J. (2007), "Laboratory tests of steel simple torsionally unbalanced models", Earthq. Eng. Struct. Dyn., 36(7), 887-907.   DOI
300 Hao, H. (1996), "Characteristics of torsional ground motions", Earthq. Eng. Struct. Dyn., 25(6), 599-610.   DOI
301 Hao, H. (1997), "Torsional response of building structures to spatial random ground excitations", Eng. Struct., 19(2), 105-112.   DOI
302 Hao, H. (1998), "Response of two-way eccentric building to nonuniform base excitations", Eng. Struct., 20(8), 677-684.   DOI
303 Heredia-Zanovi, E. and Leyva, A. (2003), "Torsional response of symmetric buildings to incoherent and phase-delayed earthquake groung motions", Earthq. Eng. Struct. Dyn., 32(7), 1021-1038.   DOI
304 Inoue, Y. and Shima, H. (1988), "Earthquake response of torsionally excited soil-structure systems", Proceedings of the 9th World Conference, Earthq. Eng.
305 Juarez, M. and Aviles, J. (2008), "Effective eccentricity due to the effects of structural asymmetry and wave passage", Eng. Struct., 30, 831-844.   DOI
306 Lee, V.W. and Trifunac, M.D. (1985), "Torsional accelerograms", Soil. Dyn. Earthq. Eng. 4(3), 132-139.
307 Luco, J.E. (1976), "Torsional response of structures to obliquely incident seismic SH waves", Earthq. Eng. Struct. Dyn., 4(3), 207-219.   DOI
308 Nathan, N.D. and McKenzie, J.R. (1975), "Rotational components of earthquake motion". Canadian J. Civ. Eng., 2(4), 430-436.   DOI
309 Newmark, N.M. (1969), "Torsion in symmetrical buildings", Proceedings of the 4th World Conference, Earthq. Eng. ASCE.
310 Rigato, A.B. and Medina, R.A. (2007), "Influence of angle incidence on seismic demands for inelastic single-storey structures subjected to bi-directional ground motions", Eng. Struct., 29, 2593-2601.   DOI
311 Syamal, P.K. and Pekau, O.A. (1985), "Dynamic response of bilinear asymmetric structures", Earthq. Eng. Struct. Dyn., 13(4), 527-541.   DOI
312 Pettinga, J.D., Priestley, M.J.N., Pampanin, S. and Christopoulos, C. (2007), "The role of inelastic torsion in the determination of residual deformations", J. Earthq. Eng., 11, 133-157.
313 Rossi, P.P. (2000). "Ductility and energy dissipation demands of asymmetric buildings", Proceedings of the 12th World Conference, Earthq. Eng.
314 Sadek, A.W., Sobaih, M.E. and Esmail, H.S. (1992), "Approximate seismic analysis of inelastic asymmetric structures", Eng. Struct., 14(1), 49-63.   DOI
315 Zhu, T.J. and Tso, W.K. (1992), "Design of torsionally unbalanced structural systems based on code provisions II: Strength distribution", Earthq. Eng. Struct. Dyn., 21, 629-644.   DOI
316 Bosco, M., Ghersi, A. and Marino, E.M. (2012), "Corrective eccentricities for assessment by the nonlinear static method of 3D structures subjected to bidirectional ground motions", Earthq. Eng. Struct. Dyn., 41(13), 1751-1773.   DOI
317 Correnza, J.C., Hutchinson, G.L. and Chandler, A.M. (1994), "Effect of transverse load-resisting elements on inelastic earthquake response of eccentric-plan buildings", Earthq. Eng. Struct. Dyn., 23(1), 75-90.   DOI
318 De La Colina, J. (1999), "Effects of torsion factors on simple non-linear systems using fully-bidirectional analyses", Earthq. Eng. Struct. Dyn., 28, 691-706.   DOI
319 De La Llera, J.C. and Chopra, A.K. (1995), "Understanding the inelastic seismic behaviour of asymmetricplan buildings", Earthq. Eng. Struct. Dyn., 24(4), 549-572.   DOI
320 Fardis, M.N., Bousias, S.N., Franchioni, G. and Panagiotakos, T.B. (1999), "Seismic response and design of RC structures with plan-eccentric masonry infills", Earthq. Eng. Struct. Dyn., 28(2), 173-191.   DOI
321 Kohyama, M., Shimazu, T., Araki, H. and Ishii, S. (1988), "Fundamental study on dynamic torsional responses of R/C space structures", Proceedings of the 9th World Conference, Earthq. Eng., IV, 687-692.
322 Maheri, M.R., Chandler, A.M. and Bassett, R.H. (1991), "Coupled lateral-torsional behaviour of frame structures under earthquake loading", Earthq. Eng. Struct. Dyn., 20(1), 61-85.   DOI
323 McCrum, D.P. and Broderick, B.M. (2013), "An experimental and numerical investigation into the seiusmic performance of a multi-storey concentrically braced plan irregular structure", Bul. Earthq. Eng., 11(6), 2363-2385.   DOI
324 Mola, E., Negro, P. and Pinto, A., (2004), "Evaluation of current approaches for the analysis and design of multi-story torsionallt unbalanced frames", Proceedings of the 13th World Conference, Earthq. Eng.
325 Seki, M. and Okada, T. (1984), "Nonlinear earthquake response test of torsionally coupled reinforced concrete building frames", Proceedings of the 8th World Conference, Earthq. Eng., 6, 315-322.
326 Shahrooz, B.M. and Moehle, J.P. (1990), "Seismic response and design of setback buildings", J. Struct. Eng. 116(5), 1423-1439.   DOI
327 Sfura, J., Hayes, J. and Foutch, D., (2004), "Investigation of torsional response in a shaketable model", Proceedings of the 13th World Conference, Earthq. Eng.
328 Basu, D. and Jain, S. (2004), "Seismic analysis of asymmetric buildings with flexible floor diaphragms", J. Struct. Eng., 130(8), 1169-1176.   DOI   ScienceOn
329 Shakib, H. and Datta, T.K. (1993), "Inelastic response of torsionally coupled system to an ensemble of nonstationary random ground motion", Eng. Struct., 15(1), 13-20.   DOI
330 Rutenberg, A. and Heidebrecht, A.C. (1985), "Response spectra for torsion, rocking and rigid foundation", Earthq. Eng. Struct. Dyn., 13(4), 543-557.   DOI
331 Shakib, H. and Tohidi, R.Z. (2002), "Evaluation of accidental eccentricity in buildings due to rotational component of earthquake", J. Earthq. Eng., 6(4), 431-445.   DOI
332 Smerzini, C., Paolucci, R. and Stupazzini, M. (2009), "Experimental and numerical results on earthquakeinduced rotational ground motions", J. Earthq. Eng., 13(S1), 66-82.   DOI
333 Tso, W.K. and Hsu, T.I. (1978), "Torsional spectrum for earthquake motions", Earthq. Eng. Struct. Dyn., 6(4), 375-382.   DOI
334 Vasquez, J. and Riddell, R. (1988), "An equivalent torsional component of ground motion for earthquake design of buildings", Proceedings of the 9th World Conference, Earthq. Eng., Japan Association for Earthquake Disaster Prevention.
335 Wu, S.T. and Leyendecker, E.V. (1984), "Dynamic eccentricity of structures subjected to S-H waves", Earthq. Eng. Struct. Dyn., 12, 619-628.   DOI
336 Yeh, C.S., Loh, C.H. and Su, G.W. (1992), "Results of observation of torsional ground motions and response analysis", Proceeding of the 10th World Conference, Earthq. Eng.
337 Anastasiadis, K., Athanatopoulou, A. and Makarios, T. (1998), "Equivalent static eccentricities in the simplified methods of seismic analysis of buildings", Earthq. Spectra, 14(1), 1-34.   DOI
338 Antonelli, R.G., Meyer, K.J. and Oppenheim, I.J. (1981), "Torsional instability in structures", Earthq. Eng. Struct. Dyn., 9(3), 221-237.   DOI
339 De Stefano, M., Faella, G. and Ramasco, R. (1998), "Inelastic seismic response of one-way plan-asymmetric systems under bi-directional ground motions", Earthq. Eng. Struct. Dyn., 27(4), 363-376.   DOI
340 De Stefano, M. and Rutenberg, A. (1999), "Seismic stability and the force reduction factor of code-designed one-storey asymmetric structures", Earthq. Eng. Struct. Dyn., 28, 785-803.   DOI
341 De Stefano, M. and Pintucchi, B. (2004), "Seismic analysis of eccentric building structures by meansof a refined one storey model", Proceedings of the 13th World Conference, Earthq. Eng., Vancouver, Canada.
342 De Stefano, M. and Pintucchi, B. (2010), "Predicting torsion-induced lateral displacements for pushover analysis: Influence of torsional system characteristics", Earthq. Eng. Struct. Dyn., 39(12), 1369-1394.   DOI
343 Dusicka, P., Davidson, B.J. and Ventura, C.E. (2000), "Investigation into the significance of strength characteristics in inelastic torsional seismic response", Proceedings of the 12th World Conference, Earthq. Eng.
344 Dutta, S.C. and Das, P.K. (2002), "Inelastic seismic response of code-designed reinforced concrete asymmetric buildings with strength degradation", Eng. Struct., 24, 1295-1314.   DOI
345 Dutta, S.C., Das, P.K. and Roy, R. (2005), "Seismic behavior of code-designed bidirectionally eccentric systems", J. Struct. Eng., 131(10), 1497-1514.   DOI
346 Ghersi, A. and Rossi, P.P. (2001), "Influence of bi-directional ground motions on the inelastic response of one-story in-plan irregular systems", Eng. Struct., 23, 579-591.   DOI
347 Goel, R. (1997), "Seismic response of asymmetric systems: Energy-based approach", J. Struct. Eng., 123(11), 1444-1453.   DOI
348 Snyder, M.D., Bazan-Zurita, E. and Vaidya, N.R. (1996), "Impact of accidental eccentricity in the seismic design of industrial facilities", Proceedings of the 11th World Conference, Earthq. Eng.
349 De La Colina, J. (2000), "Effect of flexible horizontal diaphragms on the seismic torsional resistance of systems with ductile walls", Proceedings of the 12th World Conference, Earthq. Eng.
350 Murakami, M., Moss, P.J., Carr, A.J. and Inayama, M. (2000), "The effect of floor in plane flexibility on the response of torsionally unbalanced systems", Proceedings of the 12th World Conference, Earthq. Eng.
351 Baros, D.K. and Anagnostopoulos, S.A. (2008), "An overview of pushover procedures for the analysis of buildings susceptible to torsional behavior", Proceedings of the 14th World Conference, Earthq. Eng.
352 Bento, R., Bhatt C. and Pinho R. (2010), "Using nonlinear static procedures for seismic assessment of the 3D irregular SPEAR building", Earthq. Struct., 1(2), 177-195.   DOI   ScienceOn
353 Bhatt, C. and Bento, R. (2012), "Comparison of nonlinear static methods for the seismic assessmnet of plan irregular frame buildings with non seismic details", J. Earthq. Eng., 16, 15-39.   DOI
354 Bhatt, C. and Bento, R. (2014), "The extended adaptive capacity spectrum method for the seismic assessment of plan-asymmetric buildings", Earthq. Spectra, 30(2).
355 Bosco, M., Ghersi, A. and Marino, E.M. (2012a), "Corrective eccentricities for assessment by the nonlinear static method of 3D structures subjected to bidirectional ground motions", Earthq. Eng. Struct. Dyn., 41(13), 1751-1773.   DOI
356 Chandler, A.M. and Hutchinson, G.L. (1986), "Torsional coupling effects in the earthquake response of asymmetric buildings", Eng. Struct., 8(4), 222-237.   DOI
357 Ayre, R.S. (1938), "Interconnection of translational and torsional vibration in structures", Bul. Seism. Soc. Am., 28, 89-130.
358 Banerji, P. and Barve, M. (2008), "Effect of uncertainties in structural parameters on earthquake response of torsionally-coupled buildings", Proceedings of the 14th World Conference, Earthq. Eng.
359 Bustamante, J.I. and Rosenblueth, E. (1960), "Buildng code provisions on torsional oscillation", Proceedings of the 2nd World Conference, Earthq. Eng.
360 Chandler, A.M. and Hutchinson, G.L. (1987a), "Evaluation of code torsional provisions by a time history approach", Earthq. Eng. Struct. Dyn., 15(4), 491-516.   DOI
361 Chandler, A.M. and Hutchinson, G.L. (1987b), "Code design provisions for torsionally coupled buildings on elastic foundation", Earthq. Eng. Struct. Dyn., 15(4), 517-536.   DOI
362 Chandler, A.M. and Hutchinson, G.L. (1987c), "Parametric earthquake response of torsionally coupled buildings with foundation interaction", Soil Dyn. Earthq. Eng., 6(3), 138-148.   DOI
363 Chandler, A.M. and Hutchinson, G.L. (1988), "A modified approach to earthquake resistant design of torsionally coupled buildings", Bul. NZ. Natl. Soc. Earthq. Eng., 21(2), 140-153.
364 Chandler, A.M. and Hutchinson, G.L. (1992), "Effect of structural period and ground motion parameters on the earthquake response of asymmetric buildings", Eng. Struct., 14(6), 354-360.   DOI
365 Sadek, A.W. and Tso, W.K. (1989), "Strength eccentricity concept for inelastic analysis of asymmetrical structures", Eng. Struct., 11, 189-194.   DOI
366 Humar, J.L. and Kumar, P. (1999), "Effect of orthogonal inplane structural elements on inelastic torsional response", Earthq. Eng. Struct. Dyn., 28, 1071-1097.   DOI
367 Riddell, R. and Santa-Maria, H. (1999), "Inelastic response of one-story asymmetric-plan systems subjected to bi-directional earthquake motions", Earthq. Eng. Struct. Dyn., 28, 273-285.   DOI
368 Sadek, A.W. and Tso, W.K. (1988), "Strength eccentricity concept for inelastic analysis of asymmetric structures", Proceedings of the 9th World Conference, Earthq. Eng.
369 Stathopoulos, K.G. and Anagnostopoulos, S.A. (1998), "Elastic and inelastic torsion in buildings", Proceedings of the 11th European Conference, Earthq. Eng.
370 Tso, W.K. and Sadek, A.W. (1984), "Inelastic response of eccentric buildings subjected to bi-directional ground motions", Proceedings of the 8th World Conference, Earthq. Eng.
371 Tso, W.K. and Wong, C.M. (1993), "An evaluation of the New Zealand code torsional provision", Bul. NZ Natl. Soc. Earthq. Eng., 26(2), 194-207.
372 Tso, W.K. and Wong, C.M. (1995a), "Eurocode 8 seismic torsional provisions evaluation", Europ. Earthq. Eng., IX(1), 23-33.
373 Tso, W.K. and Wong, C.M. (1995b), "Seismic displacements of torsionally unbalanced buildings", Earthq. Eng. Struct. Dyn., 24, 1371-1387.   DOI
374 Tso, W.K. and Smith, R.S. (1999), "Re-evaluation of seismic torsional provisions", Earthq. Eng. Struct. Dyn., 28, 899- 917.   DOI
375 Chopra, A.K. and Goel, R.K. (2004), "A modal pushover analysis procedure for estimating seismic demands to estimate seismic demands for unsymmetric-plan buildings", Earthq. Eng. Struct. Dyn., 33, 903-927.   DOI
376 Bosco, M., Ferrara, G., Ghersi, A., Marino, E.M. and Rossi, P.P. (2012b), "Predicting displacement demand of multi-storey asymmetric buildings by nonlinear static analysis and corrective eccentricities", Proceedings of the 15th World Conference, Earthq. Eng.
377 Bosco, M., Ghersi, A. and Marino, E.M. (2013), "Comparison of non-linear static methods for the assessment of asymmetric buildings", Bull. Earthq. Eng., 11(6), 2287-2308.   DOI
378 Chopra, A.K. and Goel, R.K. (2002), "A modal pushover analysis procedure for estimating seismic demands for buildings", Earthq. Eng. Struct. Dyn., 31(3), 561-582.   DOI
379 Cimellaro, G.P., Giovine, T. and Lopez-Garcia, D. (2014), "Bidirectional pushover analysis of irregular structures", J. Struct. Eng., 140(9).
380 D' Ambrisi, A., De Stefano, M. and Tanganelli, M. (2009), "Use of pushover analysis for predicting seismic response of irregular buildings: A case study", J. Earthq. Eng., 13, 1089-1100.   DOI
381 De Stefano, M. and Rutenberg, A. (1998), "Predicting the dynamic response of asymmetric multistory wallframe structures by pushover analysis: Two case studies", Proceedings of the 11th Europe Conference, Earthq. Eng.
382 Dolsek, M. and Fajfar, P. (2007), "Simplified probabilistic seismic performance assessment of planasymmetric buildings", Earthq. Eng. Struct. Dyn., 36(13), 2021-2041.   DOI
383 Erduran, E. (2008), "Assessment of current nonlinear static procedures on the estimation of torsional effects in low-rise frame buildings", Eng. Struct., 30, 2548-2558.   DOI
384 Gasparini, G., Silvestri, S. and Trombetti, T. (2008), "A simlpe code-like formula for estimating the torsional effects on structures subjected to earthquake ground motion excitation", Proceedings of the 14th World Conference, Earthq. Eng.
385 Dempsey, K.M. and Irvine, H.M. (1979), "Envelopes of maximum seismic response for a partially symmetric single storey building model", Earthq. Eng. Struct. Dyn., 7(2), 161-180.   DOI
386 Dempsey, K.M. and Tso, W.K. (1982), "An alternative path to seismic torsional provisions", Soil Dyn. Earthq. Eng., 1(1), 3-10.
387 Gasparini, G., Silvestri, S. and Trombetti, T. (2004), "A simplified approach to the analysis of torsional effects in eccentric systems: the alpha method", Proceedings of the 13th World Conference, Earthq. Eng.
388 Hernandez, J.J. and Lopez, O.A. (2000), "Influence of bidirectional seismic motion on the response of asymmetric buildings", Proceedings of the 12th World Conference, Earthq. Eng.
389 Housner, G.W. and Outinen, H. (1958), "The effect of torsional oscillations on earthquake stresses", Bul. Seism. Soc. Amer., 48, 221-229.
390 Kan, C.L. and Chopra, A.K. (1977), "Effects of torsional coupling on earthquake forces in buildings", J. Struct. Div., 103(4), 805-819.
391 Kung, S.Y. and Pecknold, D.A. (1984), "Seismic response of torsionally coupled single-storey structures", Proceeding of the 8th World Conference, Earthq. Eng.
392 Rady, M.A. and Hutchinson, G.L. (1988), "Evaluation of dynamic eccentricities obtained using a probabilistic approach, response spectrum methods and modern building codes", Earthq. Eng. Struct. Dyn., 16(2), 275-291.   DOI
393 Aziminejad, A. and Moghadam, A.S. (2012), "Performance of two directional asymmetric buildings in farfield and nearfield earthquakes", Proceedings of the 15th World Conference, Earthq. Eng.
394 Wong, C.M. and Tso, W.K. (1994), "Inelastic seismic response of torsionally unbalanced systems designed using elastic dynamic analysis", Earthq. Eng. Struct. Dyn., 23(7), 777-798.   DOI
395 Wong, C.M. and Tso, W.K. (1995), "Evaluation of seismic torsional provisions in uniform building code", J. Struct. Eng., 121(10), 1436-1442.   DOI
396 Ayala, A.G., Garcia, O. and Escobar, J.A. (1992), "Evaluation of seismic design criteria for asymmetric buildings", Proceedings of the 10th World Conference, Earthq. Eng.
397 Dutta, S.C., Das, P.K. and Roy, R. (2005), "Seismic behavior of code-designed bidirectionally eccentric systems", J. Struct. Eng., 131(10), 1497-1514.   DOI
398 Ghersi, A. and Rossi, P.P. (2006), "Influence of design procedures on the seismic response of bi-eccentric plan-asymmetric systems", Struct. Des. Tall Build., 15, 467-480.   DOI
399 Goel, R. (1997), "Seismic response of asymmetric systems: Energy-based approach", J. Struct. Eng., 123(11), 1444-1453.   DOI
400 Lucchini, A., Monti, G. and Kunnath, S. (2011), "Nonlinear response of two-way asymmetric single-strory building under biaxial excitation", J. Struct. Eng., 137(1), 34-40.   DOI
401 Perus, I. and Fajfar, P. (2005), "On the inelastic torsional response of single-storey structures under bi-axial excitation", Earthq. Eng. Struct. Dyn., 34(8), 931-941.   DOI
402 Prasad, B.K. and Jagadish, K.S. (1989), "Inelastic torsional response of a single-story framed structure", J. Eng. Mech., 115(8), 1782-1797.   DOI
403 Fujii, K. (2011), "Nonlinear static procedure for multi-story asymmetric frame buildings considering bidirectional excitation", J. Earthq. Eng., 15, 245-273.   DOI
404 Faella, G. and Kilar, V. (1998), "Asymmetric multistorey R/C frame structures: push-over versus nonlinear dynamic analysis", Proceedings of the 11th Europe Conference, Earthq. Eng.
405 Fajfar, P., Marusic, D. and Perus, I. (2005), "Torsional effects in the pushover-based seismic analysis of buildings", J. Earthq. Eng., 9(6), 831-854.   DOI
406 Fujii, K., Nakano, Y. and Sanada, Y. (2004), "Simplified nonlinear analysis procedure for asymmetric buildings", Proceedings of the 13th World Conference, Earthq. Eng.
407 Goel, R.K. (2004), "Evaluation of nonlinear static procedures using building strong motion records", Proceedings of the 13th World Conference, Earthq. Eng.
408 Kilar, V. and Fajfar, P. (1996), "Simplified push-over analysis of building structures", Proceedings of the 11th World Conference, Earthq. Eng.
409 Kilar, V. and Fajfar, P. (1997), "Simple push-over analysis of asymmetric buildings", Earthq. Eng. Struct. Dyn., 26(2), 233-249.   DOI
410 Kreslin, M. and Fajfar, P. (2012), "The extended N2 method considering higher mode effects in both plan and elevation", Bul. Earthq. Eng., 10, 695-715.   DOI
411 Lucchini, A., Monti, G. and Kunnath, S. (2008), "A simplified pushover method for evaluating the seismic demand in asymmetric-plan multi-story buildings", Proceedings of the 14th World Conference, Earthq. Eng.
412 Magliulo, G., Maddaloni, G. and Cosenza, E. (2008), "Extension of N2 method to plan irregular buildings considering accidental eccentricity", Proceedings of the 14th World Conference, Earthq. Eng.
413 Sikaroudi, H. and Chandler, A.M. (1992), "Structure-foundation interaction in the earthquake response of torsionally asymmetric buildings", Soil Dyn. Earthq. Eng., 11(1), 1-16.   DOI
414 Rutenberg, A. and Pekau, O.A. (1987), "Seismic code provisions for asymmetric structures: A reevaluation", Eng. Struct., 9(4), 255-264.   DOI
415 Rutenberg, A. and Pekau, O.A. (1989), "Seismic code provisions for asymmetric structures: Low period systems", Eng. Struct., 11(2), 92-96.   DOI
416 Shakib, H. (2004), "Evaluation of dynamic eccentricity by considering soil-structure interaction: a proposal for seismic design codes", Soil Dyn. Earthq. Eng., 24, 369-378.   DOI
417 Stathopoulos K.G. and Anagnostopoulos S.A. (1998), "Elastic and Inelastic Torsion in Buildings", Proceedings of the 11th European Conference, Earthq. Eng.
418 Trombetti, T., Silvestri, S., Gasparini, G., Pintucchi, B. and De Stefano, M. (2008), "Numerical verification of the effectiveness of the "Alpha" method for the estimation of the maximum rotational elastic response of eccentric systems", J. Earthq. Eng., 12, 249-280.   DOI
419 Trombetti, T., Palermo, M., Silvestri, S. and Gasparini, G. (2012), "Period shifting effect on the corner displacement magnification of one-storey asymmetric systems", Proceedings of the 15th World Conference, Earthq. Eng.
420 Tsicnias, T.G. and Hutchinson, G.L. (1981), "Evaluation of code requirements for the earthquake resistant design of torsionally coupled buildings", Proceedings of the Inst. Civ. Eng., 71(2), 821-843.   DOI
421 Tsicnias, T.G. and Hutchinson, G.L. (1982), "Evaluation of code torsional provisions for earthquake resistant design of single storey buildings with two eccentricity components", Proceedings of the Inst. Civ. Eng., 73(2), 455-464.   DOI
422 Anagnostopoulos, S.A. (1972), "Non-linear dynamic respom nse and ductility requirements of building structures subjected to earthquakes", Rep. No. R72-54, Massachusetts Inst. Tech., Civ. Eng. Dept.
423 Stathopoulos, K.G. and Anagnostopoulos, S.A. (2000), "Inelastic earthquake response of buildings subjected to torsion", Proceedings of the 12th World Conference, Earthq. Eng.
424 Stathopoulos, K.G. and Anagnostopoulos, S.A. (2003), "Inelastic earthquake response of single-story asymmetric buildings: an assessment of simplified shear-beam models", Earthq. Eng. Struct. Dyn., 32, 1813-1831.   DOI
425 Stathopoulos, K.G. and Anagnostopoulos, S.A. (2007), "Inelastic seismic response of asymmetric one-story steel buildings", ECCOMAS Thematic Conference Composition Methods Struct. Dyn. Earthq. Eng., Rethymno, Crete. Greece
426 Anagnostopoulos, S.A., Roesset, J.M. and Biggs, J.M. (1973), "Non-linear dynamic analysis of buildings with torsional effects", Proceedings of the 5th World Conference, Earthq. Eng.
427 Anagnostopoulos, S.A. and Roesset, J.M. (1973), "Ductility requirements for some nonlinear systems subjected to earthquakes", Proceedings of the 5th World Conference, Earthq. Eng.
428 Chandler, A.M. and Duan, X.N. (1993), "A modified static procedure for the design of torsionally unbalanced multi- storey frame buildings", Earthq. Eng. Struct. Dyn., 22(5), 447-462.   DOI
429 De La Colina, J. (2003), "Assessment of design recommedations for torsionally unbalanced multistory buildings", Earthq. Spectra, 19(1), 47-66.   DOI
430 De La Llera, J.C. and Chopra, A.K. (1995), "A simplified model for analysis and design of asymmetric-plan buildings", Earthq. Eng. Struct. Dyn., 24(4), 573-594.   DOI
431 Moghadam, A.S. and Tso, W.K. (2000), "Pushover analysis for asymmetric and set-back multi-story buildings", Proceedings of the 12th World Conference, Earthq. Eng.
432 Magliulo, G., Maddaloni, G. and Cosenza, E. (2012), "Extension of N2 method to plan irregular buildings considering accidental eccentricity", Soil Dyn. Earthq. Eng., 43, 69-84.   DOI
433 Manoukas, G., Athanatopoulou, A. and Avramidis, I. (2012), "Multimode pushover analysis for asymmetric buildings under biaxial seismic excitation based on a new concept of the equivalent single degree of freedom system", Soil Dyn. Earthq. Eng., 38, 88-96.   DOI
434 Moghadam, A.S. and Tso, W.K. (1996), "Damage assessment of eccentric multistory buildings using 3-D pushover analysis", Proceedings of the 11th World Conference. Earthq. Eng.
435 Poursha, M., Khoshnoudian, f. and Moghadam, A.S. (2011), "A consecutive modal pushover procedure for nonlinear static analysis of one-way unsymmetric-plan tall building structures", Eng. Struct., 33, 2417-2434.   DOI
436 Poursha, M., Khoshnoudian, F. and Moghadam, A.S. (2014), "The extended consecutive modal pushover procedure for estimating the seismic demands of two-way unsymmetric-plan tall buildings under influence of two horizontal components of ground motions", Soil Dyn. Earthq. Eng., 63, 162-173.   DOI
437 Reyes, J.C. and Chopra, A.K. (2011a), "Three-dimensional modal pushover analysis of buildings subjected to two components of ground motion, including its evaluation for tall buildings", Earthq. Eng. Struct. Dyn., 40, 789-806.   DOI
438 Reyes, J.C. and Chopra, A.K. (2011b), "Evaluation of three-dimensional modal pushover analysis for unsymmetric-plan buildings subjected to two components of ground motion", Earthq. Eng. Struct. Dyn., 40, 1475-1494.   DOI