Abstract
This study analyzed a monitoring data, based on the initial limit values of monitoring in subway, of concrete lining stress and reinforcement stress. The data is obtained from 7 sections of the Seoul metropolitan subway line No 6, 7, and 9 in about 5 years. Also, a research is performed to set up the limit values of management monitoring, which will be applied to management monitoring in tunnel, through comparing the limit values of overseas management monitoring data and that of domestic management monitoring data. And the result obtained from comparison shows that the safety phase is 60% of allowable stress, the attention phase is 80% of allowable stress and the precision analysis phase is 100% of allowable stress. Also, we presented a method of management monitoring by the absolute value which can be easily applied in practical affairs.
Keywords
Management monitoring in tunnel; Stress limit values; Concrete lining stress; Concrete lining reinforcement stress;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Woo, J.T., Lee, R.C. (2008b), "Construction monitoring engineering", Goomi Publishing Co.,
2 Woo, J.T. (2009), "A study on comparison of a ground water influx quantity in Seoul subway tunnel", Journal of Korean Tunnelling and Underground Space Association, Vol. 11, No. 4, pp. 353-359.
3 Woo, J.T., Lee, K.I. (2012), "A study on establishment of measurement and analysis frequency of maintenance monitoring in tunnel", Journal of Korean Tunnelling and Underground Space Association, Vol. 14, No. 2, pp. 117-129.   DOI
4 Woo, J.T. (2013), "A study on estimation of the total loss and damage ratio of maintenance monitoring sensor of subway tunnel", Journal of Korean Tunnelling and Underground Space Association, Vol. 15, No. 1, pp. 25-31.   DOI
5 Woo, J.T. (2014), "A study on the estimation of the optimal number of monitoring points in singletrack tunnel lining with the inverse analysis program", Journal of Korean Tunnelling and Underground Space Association, Vol. 16, No. 1, pp. 1-11.   DOI
6 Curtis, D.J., Spaul, J.A. (1996), "Monitoring of the UK tunnel lining, engineering geology of the channel tunnel", pp. 277-286.
7 Eurotunnel, Transmanche-Link. (1991), "Monitoring of tunnel lining second annual report", Gage technique limited.
8 Lee, D.H., Han, I.Y., Kim, G.S., Jin, S.W. (2000), "Case studies on applications of convergence measurement system at the stages of tunnel construction and maintenance", Journal of Korean Tunnelling and Underground Space Association, Vol. 2, No. 3, pp. 59-69.
9 Lee, S., Woo, J.T. (2003), "Design and construction of retaining earth structure", Yeamoonsa, pp. 292-295.
10 Moore. D.R., Crease, A. (1996), "Tunnel Instrumentation, Engineering Geology of the Channel Tunnel", pp. 287-294.
11 Shim, J.S. (2012), "Reinforced concrete structural design", Goomi Publishing Co., pp. 29-32.
12 Woo, J.T., Lee, S. (2002), "A stress of tunnel lining for maintenance monitoring", Journal of Korean Concrete Association, Vol. 14, No. 3, pp. 341-348.
13 Woo, J.T., Lee, R.C. (2008a), "Construction monitoring engineering", Goomi Publishing Co., pp. 760-763.