Browse > Article
http://dx.doi.org/10.12652/Ksce.2014.34.1.0087

Characteristics of Bond Behavior According to Confinement and Stiffness Ratios of External Confining Jackets  

Choi, Eunsoo (Hongik University)
Jung, Chunsung (Hongik University)
Publication Information
KSCE Journal of Civil and Environmental Engineering Research / v.34, no.1, 2014 , pp. 87-94 More about this Journal
Abstract
This study analyzes the characteristics of bond behavior of concrete, which is confined by external jackets such as shape memory alloy (SMA) and steel, according to confinement and stiffness ratios of the external jackets. For this purpose, SMA wires with 1.0 mm diameter and steel plates with 1.0 and 1.5 thickness are used to induce difference on confinement and stiffness ratios and, then, bond strength and behavior are analyzed considering the two factors. When external jakcets are used for the concrete cylinders, bond strengths of specimens increase and their bond failures are transferred from splitting failure to pull-out failure and, thus, the external jackets show confining effect. Bond strenght of concrete increase with increasing confinement and stiffness ratios of the external jackets. However, maximal circumferential strains decrease linearly with increasing the two values.
Keywords
Bond strength; Confinement ratio; Stiffness ratio; Bond failure; Circumferential strain;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Choi, E., Park, J. Nam, T. H. and Yoon, S. J. (2006). "A new steel jacketing method for RC columns." Magazine of Concrete Research, Vol. 61, pp. 787-796.
2 Lee, H., Choi, E., Cho, S. C. and Park, T. (2012). "Bond and splitting behavior of reinforced concrete confined by steel jackets without grouting." Magazine of Concrete Research, Vol. 64, No. 3, pp. 225-237.   DOI   ScienceOn
3 Lundgren, K. (2000). "Pull-out tests of steel-encased specimens subjected to reversed cyclic loading." Material and Structures, Vol. 33, pp. 450-456.   DOI
4 Pantelides, C. P., Alameddine, F., Sardo, T. and Imbsen, R. (2004). "Seismic retrofit of state stress bridge on Interstate 80." Journal of Bridge Engineering, ASCE, Vol. 9, No. 4, pp. 333-342.   DOI
5 Pantelides, C. P., Duffin, J. B. and Reaveley, L. D. (2007). "Seismic strengthening of reinforced concrete multicolumn bridge piers." Earthquake Engineering, Vol. 23, No. 3, pp. 635-664.
6 Park, J., Choi, E., Park, K. and Kim, H. T. (2011). "Comparison the cyclic behavor of concrete cylinders confined by shape memory alloy wire or steel jackets." Smart Materials and Structures, Vol. 20, 094008.   DOI   ScienceOn
7 Priestley, M. J. N., Seible, F. and Calvi, G. M. (1996). Seismic design and retrofit of bridges, Wiley, New York, NY, US.
8 ACI Committee 318. (2002). Building code requirements for structural concrete and commentary (ACI 318M-02), Michigan, American Concrete Institute.
9 Andrawes, B., Shin, M. and Wierschem, N. (2010). "Active confining of reinforced concrete bridge columns using shape memory alloys." Journal of Bridge Engineering, Vol. 15, No. 1, pp. 81-89.   DOI   ScienceOn
10 Choi, E., Chung, Y. S., Park, K. and Jeon, J. S. (2013). "Effect of steel wrapping jackets on the bond strength of concrete and the lateral performance of circular RC columns." Engineering Structures, Vol. 48, pp. 43-54.   DOI   ScienceOn
11 Choi, E., Chung, Y. S., Choi, D. H. and DesRoches, R. (2012). "Seismic protection of lap-spliced RC columns using SMA wire jackets." Magazine of Concrete Research, Vol. 64, No. 3, pp. 239-252.   DOI   ScienceOn
12 Choi, E., Chung, Y. S., Choi, J. H., Kim, H. T. and Lee, H. (2010). "The confining effectiveness of NiTiNb and NiTi SMA wire jackets for concrete." Smart Materials and Structures, Vol. 19, 035024.   DOI   ScienceOn
13 Choi, E., Chung, Y. S., Kim, Y. W. and Kim, J. W. (2011). "Monotonic and cyclic bond behavior of confined concrete using NiTiNb SMA wires." Smart Materials and Structures, Vol. 20, 075016.   DOI   ScienceOn