Browse > Article

Performance Test of PEMFC with Hollow Fiber Membrane  

Lee, Ho-Yeol (Grad. School of Chonnam National University)
Chon, Kwang-Wu (Grad. School of Chonnam National University)
Park, Chang-Kwon (Grad. School of Chonnam National University)
Oh, Byeong-Soo (Dept. of Mechanical System Engineering, Chonnam National University)
Publication Information
Transactions of the Korean hydrogen and new energy society / v.16, no.1, 2005 , pp. 82-91 More about this Journal
Abstract
Polymer membrane needs to maintain appropriate moisture. Insufficient moisture causes low conduction of hydrogen ion because of increased contact resistance between electrode and membrane by shrinking membrane, and abundant moisture decreases fuel cell performance as difficulty of diffusion reacting gas. Therefore, water controlling system is very consequential for the polymer membrane fuel cell. If hollow fiber membrane humidification is used between fuel and air lines, it is possible to supply heat to fuel and air by using thermal exchanger. It can supply appropriate humidity depending on operating temperature, and can recover heat from exhaust gas which contains water vapor and air. Because of simple structure of humidification system, this system can be easily applied in the PEMFC and cut down cost.
Keywords
PEMFC; MEA; UF Membrane; Hollow Fiber Membrane;
Citations & Related Records
연도 인용수 순위
  • Reference
1 박세규, 고분자 전해질 연료전지용 막가습기의 가습 특성에 관한 연구, 연세학교, 2002
2 안성진, 평행함침환원법에 의한 Pt-membrane이 자기가습형 PEMFC 성능에 미치는 영향, 연세대학교, 2000
3 현덕수, 고분자 전해질 연료전지의 가습조건에 대한 연구, 울산대학교, 2000
4 정귀성, PEMFC시스템의 성능 및 연료전지 하이브리드 자동차 구동에 관한 연구, 전남대학교, 2003